MAURY USCG vessel records
← All vessels

EAST BAY

EAST BAY is a 1997 freight ship. The Coast Guard has recorded 11 inspections since 2016, most recently in May 2018, along with 8 deficiencies and 2 operational controls.

Records from 2016 to 2018. Most recent: inspection, 10 May 2018.

Built
1997
Last inspected
10 May 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 May 2018
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9149653
462060
Flag
LIBERIA
Maury page id
psix-462060

Documentation record

Tonnage as PSIX records it37543 - Displacement, Metric Ton
29517 - Dead Weight, Metric Ton
19354 - Convention (Subpart B), Gross Ton
9614 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

10 May 2018 COE-Dockside · PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6404637
27 March 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6379909
19 October 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6290830
26 May 2017 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6155932
24 April 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6122915
17 January 2017 ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6068658
29 July 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5956924
26 July 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5953651
23 April 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5860615
21 April 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5859249
17 March 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5835079

Deficiency record · 8

Engineering › Steering Gear System › Rudder Stock
Issued 10 May 2018 Resolved
0936- Steering Gear- All the steering gear components and the other ruder stock shall be of sound and reliable construction... provided with lubrication fittings. PSCO observed heavy hydraulic fluid leak from the main steering gear during operation. Vessel must provide class report stating that repairs ave been made. SOLAS 74 (04) Cons. II-1/29.2.1.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 May 2018
Resolution: Received class report from surveyor S. Smyk of NKK stating all outstanding deficiencies have been rectified. The class report stated: Crew disassembled the rotorhousing again and inserted additional thin rubber gasket in order to stop the leak.
Engineering › Steering Gear System › Hydraulic Hose
Issued 10 May 2018 Resolved
Hydraulic power operated steering gear shall be provided with the following: a fixed storage tank having sufficient capacity. PSCO observer the hydraulic oil storage tank had a low amount of fluid due to periodically refilling the hydraulic service reservoirs due to a leaking steering system.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 10 May 2018
Resolution: Ship's crew refilled the storage tank to the satisfaction of the PSCO.
Lifesaving › Inflatable Liferafts › Float Free
Issued 10 May 2018 Resolved
Each liferaft or group of liferafts shall be stowed with a free float arrangement complying with the requirements of REG 38.6. PSCO observed hydrostatic release was not properly stowed not allowing for free floating of the liferaft.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 10 May 2018
Resolution: PSCO witnessed proper free float arrangement of free floating liferafts.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 26 May 2017 Resolved
Angular position of the rudder shall be indicated on the navigation bridge and be recognizable in the steering gear compartment. All rudder angle indicating repeaters vary by more than five degrees in both directions while in all modes of steering. 74SOLAS(04)II-1/29.11
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 May 2017
Resolution: Deficiency rectified to satisfaction of attending class inspector.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 May 2017 Resolved
The oily water separator is not capable of processing bilge water to less than 15ppm. While running OWS the sample line to the oil content meter was secured falsely indicating 3ppm. When the sample line was opened to the OCM the Reading would immediately exceed 30ppm and closed three way valve. Crew could not produce maintenance records for the system. MARPOL(2011)Annex I Reg 14.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2017
Resolution: Deficiency rectified to satisfaction of attending class inspector.
Documentation › Logs/Records › Oil Record Book
Issued 26 May 2017 Resolved
The Oil Record Book Part I shall be kept in such a place to be readily available for inspection at all reasonable times and be kept on board ship. It shall be preserved for a period of three years. Vessel is missing ORB Part I for 10MAR16 to 12DEC16.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2017
Resolution: Deficiency rectified to satisfaction of attending class inspector.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 May 2017 Resolved
Nonconductive mats or grating shall be provided at the front of the main switchboard. In ECR nonconductive matting was wasted. 74SOLAS(04)II-1/45.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2017
Resolution: Deficiency rectified to satisfaction of attending class inspector.
Fire Fighting › Firemans Outfit › Gloves
Issued 26 May 2017 Resolved
A fireman's outfit shall protect the skin from heat. Fireman's outfit gloves were wasted. 74SOLAS(97)II-2/17.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2017
Resolution: Deficiency rectified to satisfaction of attending class inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.