Records from 1985 to 2001. Most recent: inspection, 6 March 2001.
Documentation record
Registered dimensions (L × B × D)60.1 ft × 21.0 ft × 6.2 ft
Registered tonnagegross 52 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · TARPON SPRINGS FLORIDA, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing porttampa, FL
Trade endorsementsRecreational
DocumentationExpired · issued 5 January 2004 · expires 31 January 2005
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Simplified, Gross Ton
41 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
6 March 2001
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1432460
15 March 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1433611
10 November 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1375926
17 March 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 807758
8 March 1999
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1461111
24 March 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 787641
19 September 1997
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1388337
13 March 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1092826
7 March 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099145
8 March 1996
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 884554
13 February 1996
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1187883
10 January 1996
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1190920
21 March 1995
Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1132983
24 March 1994
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1326853
31 January 1994
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1162535
4 March 1993
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1152373
14 April 1992
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1266506
5 March 1992
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1254947
9 January 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1252893
7 March 1991
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1237807
3 August 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1221809
21 March 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 931493
8 March 1990
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1231710
18 April 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1235936
10 March 1989
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1196820
17 January 1989
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1034258
24 May 1988
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1350569
10 March 1987
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1310309
18 August 1986
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1312478
26 September 1985
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 991749
26 September 1985
Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 991750
Fire Fighting
Issued 8 March 1999
Resolved
REPAIR INSTALLED FIRE PUMP. VESSELS PASSENGER COUNT REDUCED TO 49 UNTIL CORRECTED AND INSPECTED BY A CG INSPECTOR.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Lifesaving
Issued 7 March 1997
Resolved
PROVIDE AN ALARM ON THE CONSOLE TO INDICATE THAT THE FORWARD WATERTIGHT DOOR IN THE ENGINEROOM IS OPEN.
Condition: Unknown
Due 14 March 1997
Resolved 16 March 1997
Engineering
Issued 21 March 1995
Resolved
Prove proper operation of fuel oil shut off valves.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Engineering
Issued 21 March 1995
Resolved
Label fuel oil shut off valves above bench seats port & stbd side.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Lifesaving
Issued 24 March 1994
Resolved
INSTALL STANCHONS TO KEEP 22 MAN LIFEFLOAT IN PLACE IN A FLOAT FREE CONDITION.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Construction/Loadline
Issued 24 March 1994
Resolved
REPAIR 4 HOLD DOWN BOLTS ON AFT DECK WATERTIGHT HATCH.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Engineering
Issued 24 March 1994
Resolved
LAG OR PLACE PROPER THERMAL PROTECTION ON PORT ENGINE EXHAUST.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Engineering
Issued 31 January 1994
Resolved
SMALL FUEL OIL LEAK AT PRE-FILTER LOCATED IN ENGINE ROOM, PORT SIDE AFT BULKHEAD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Electrical
Issued 5 March 1992
Resolved
5: FROM ENGINE COMPARTMENT, REMOVE ALL 12V/32V ELECTRICAL WIRE DEAD ENDS.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Accommodation/Occupational Safety
Issued 5 March 1992
Resolved
3: FASTEN WOOD LADDERS TO BOTH THE FORWARD AND SEWAGE COMPARTMENTS.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Construction/Loadline
Issued 5 March 1992
Resolved
4: REMOVE OIL FROM THE ENGINE COMPARTMENT BILGES.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Electrical
Issued 5 March 1992
Resolved
7: PROVIDE A GLOBE FOR THE ENGINE COMPARTMENT PORT SIDE OVERHEAD LIGHTING _x001C_FIXTURE.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Construction/Loadline
Issued 5 March 1992
Resolved
9: PROVIDE A SWR METER FOR THE VESSELS VHF-FM RADIO SYSTEM.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Lifesaving
Issued 5 March 1992
Resolved
1: PROVIDE 04 ADULT LIFE PRESERVERS (TYPE I)
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Lifesaving
Issued 5 March 1992
Resolved
2: PROVIDE A COAST GUARD APPROVED RING BUOY.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Construction/Loadline
Issued 5 March 1992
Resolved
6: REMOVE ALL LOOSE ENGINE COMPARTMENT INSULATION.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Lifesaving
Issued 8 March 1990
Resolved
REPLACE 3 ADULT PFD'S
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Navigation
Issued 10 March 1989
Resolved
FIX MASTHEAD LIGHT
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Lifesaving
Issued 10 March 1989
Resolved
PROPERLY LABEL ALL PFDS.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Lifesaving
Issued 10 March 1989
Resolved
REPLACE 3 ADULT & 1 CHILD PFD
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989