MAURY USCG vessel records Sign in
← All vessels

VIKING STARLITE

VIKING STARLITE is a 1969 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 1985, most recently in October 1994, along with 60 deficiencies.

Records from 1985 to 1994. Most recent: inspection, 26 October 1994.

Built
1969
Last inspected
26 October 1994
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WY6302
Flag
UNITED STATES
—
Maury page id
psix-46214

Inspections, by type

…with no type recorded4
Years with a record 10 calendar years (1985–1994)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 20

26 October 1994 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181872
1 December 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1158624
1 June 1993 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159115
22 May 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253110
31 March 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 958451
22 May 1991 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943800
5 February 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 924566
15 June 1990 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919433
23 June 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 897244
13 June 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1204104
2 June 1989 Hull Examination · Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1033805
17 June 1988 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 889805
15 June 1988 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1208632
31 July 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1012540
2 June 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334993
12 June 1986 Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1305066
4 June 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994217
6 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 982197
22 April 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 982699
17 April 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1289585

Deficiency record · 60

Accommodation/Occupational Safety
Issued 1 June 1993 Resolved
REPAIR OR REPLACE LADDER LEADING TO TOP OF WHEEL HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Electrical
Issued 1 June 1993 Resolved
REFASTEN AC VOLTAGE PANEL COVER IN WHEELHOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Electrical
Issued 1 June 1993 Resolved
REMARK BREAKER PANEL ON AFT BHD OF STBD SIDE OF ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Construction/Loadline
Issued 22 May 1991 Resolved
REPAIR WATER TIGHT DOOR LIGHT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Lifesaving
Issued 22 May 1991 Resolved
REPAINT RING BUOYS.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Construction/Loadline
Issued 22 May 1991 Resolved
MAKE PERMANENT REPAIRS IN WAY OF TEMP REPAIR TO AFT DECK.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Construction/Loadline
Issued 22 May 1991 Resolved
CLOSE DRILL HOLES IN A) AFT BHD STBD SIDE. B) FWD ENG RM BHD PORT AND STARBOARD PRIOR TO SAILING WITH PASSENGERS.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Engineering
Issued 22 May 1991 Resolved
INSTALL A RELIEF VALVE ON THE AIR RECEIVER. SET VALVES FOR 110' PSI.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Lifesaving
Issued 22 May 1991 Resolved
REPAINT LIFE FLOATS AND RENEW SUN ROTTED LINES.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Navigation
Issued 15 June 1990 Resolved
REPLACE DBROKEN BOLT ON STARBOARD RUDDER POST.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Documentation
Issued 15 June 1990 Resolved
REPOSTED EMERGENCY CHECK-OFF PROCEDURE AND PFD INSTRUCTIONS.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Construction/Loadline
Issued 15 June 1990 Resolved
WORKING LIGHT FOR OPEN DOOR INSTALLED.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Lifesaving
Issued 15 June 1990 Resolved
REPLACED RING BUOY.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Fire Fighting
Issued 15 June 1990 Resolved
MOUNTED BII IN GALLEY SPACE.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Fire Fighting
Issued 15 June 1990 Resolved
RECHARGED BII FOR PASSENGER ACCOMODATION.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Lifesaving
Issued 15 June 1990 Resolved
REPLACED FLOAT FREE LINK.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Electrical
Issued 15 June 1990 Resolved
LABELED BREATHERS IN DISTRIBUTION PANEL.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Engineering
Issued 13 June 1989 Resolved
PROVIDE THE PROPER GUARDS FOR THE PORT AND STARBOARD MAIN DIESEL ENGINE FLYWHEELS.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Electrical
Issued 13 June 1989 Resolved
REMOVE PLASTIC WIRE TIES AND PROPERLY SECURE IN ENGINE ROOM.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Navigation
Issued 13 June 1989 Resolved
PROVE PROPER OPERATION OF LIGHT FOR MAGNETIC COMPASS.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Navigation
Issued 13 June 1989 Resolved
PROVE PROPER OPERATION OF STERN AND ANCHOR LIGHT.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Engineering
Issued 13 June 1989 Resolved
TIGHTEN STBD SHAFT SEAL.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Electrical
Issued 13 June 1989 Resolved
REMOVE PORTABLE LIGHTS AND CABLE FROM ENGINEROOM.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Documentation
Issued 13 June 1989 Resolved
PROVIDE AND PROPERLY POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Electrical
Issued 13 June 1989 Resolved
REMOVE PORTABLE CABLE FOR FISH FREEZER AND REPLACE WITH PERMANENT INSTALLATION.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Construction/Loadline
Issued 17 June 1988 Resolved
VEE AND WELD FRACTURES IN BOTTOM LONG. IN #2 COMP. FAIR AND REWELD DISTROTED FLOOR.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Construction/Loadline
Issued 17 June 1988 Resolved
CAP OFF OR SEAL ALL UNUSED THROUGH HULL FITTINGS.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Lifesaving
Issued 17 June 1988 Resolved
PROVIDE 1 ADDITIONAL WATER LIGHT FOR LIFE FLOATS.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Engineering
Issued 17 June 1988 Resolved
BOLT ELECTRIC BILGE PUMP MOTOR TO MOUNTS.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Navigation
Issued 17 June 1988 Resolved
INSTALL BRACKETS TO SECURE THE HYDRAULIC PIPING ON THE OVERHEAD AT THE FWD END OF THE ENGINE ROOM.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Accommodation/Occupational Safety
Issued 17 June 1988 Resolved
REPLACE BROKEN WINDOWS IN MAIN DECK HOUSE AND PILOT HOUSE DOOR.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Accommodation/Occupational Safety
Issued 17 June 1988 Resolved
INSTALL VENT COWLS ON VENT PIPES LEADING TO BELOW DECK SPACES.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Accommodation/Occupational Safety
Issued 17 June 1988 Resolved
CAP OPEN PIPE FROM MSD HOLDING TANK STBD SIDE OF ENGINE ROOM.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Engineering
Issued 17 June 1988 Resolved
RELAG EXHAUST MANIFOLD STBD MDE NEAR SS GEN.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Engineering
Issued 17 June 1988 Resolved
REPLACE WASTED SECTIONS OF EXHAUST STACKS.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Navigation
Issued 17 June 1988 Resolved
PERMANENTLY MOUNT HYDRAULIC LINE FROM SUPPLY TANK TO PUMP.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Electrical
Issued 17 June 1988 Resolved
INSTALL A GUARD AROUND THE BELT DRIVE ON SS GEN.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Electrical
Issued 17 June 1988 Resolved
REPAIR WIRING ON STBD BATTERY BANK.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Electrical
Issued 17 June 1988 Resolved
PROPERLY TAPE SPLICE JOINTS IN WIRING.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Electrical
Issued 17 June 1988 Resolved
REPLACE DAMAGED LIGHT FIXTURES IN MAIN CABIN.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Electrical
Issued 17 June 1988 Resolved
REPLACE BATTERY FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Construction/Loadline
Issued 17 June 1988 Resolved
RPAIR TRICK WHEEL AND DOGS FOR MAIN DECK HATCHES FWD OF HOUSE AND AFT OF HOUSE.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Construction/Loadline
Issued 2 June 1987 Resolved
MAKE BULKHEAD BETWEEN ENGINEROOM AND ACCOMMOATION SPACE WATERTIGHT WHERE WIRES PASS THROUGH BULKHEAD.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Electrical
Issued 2 June 1987 Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP ON GENERATOR.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Electrical
Issued 2 June 1987 Resolved
REMOVE WIRES DIRECTLY CONNECTED TO BATTERIES AND PROVIDE MAIN DISCONNECT AND OVERCURRENT PROTECTION FOR THE CIRCUITS.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Engineering
Issued 2 June 1987 Resolved
PROVIDE LAGGING FOR EXHAUST STACKS.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Construction/Loadline
Issued 2 June 1987 Resolved
MARK WATERTIGHT DOOR BETWEEN ACCOMMODATIONS SPACES THAT IT MUST REMAIN CLOSED WHILE UNDERWAY.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Electrical
Issued 2 June 1987 Resolved
REMOVE ALL WIRE NUTS FROM ENGINEROOM.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Electrical
Issued 2 June 1987 Resolved
REPAIR EMERGENCY LIGHTING.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Construction/Loadline
Issued 2 June 1987 Resolved
PROVIDE HOLD BACK DEVICE FOR AFTER STEERING COMPARTMENT.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Engineering
Issued 2 June 1987 Resolved
PROVIDE FLAME SCREEN FOR FUEL VENT.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Engineering
Issued 6 June 1985 Resolved
TEST TO 200 PSI THE AIR HORN PRESSURE VESSEL, OR PROVIDE TESTING, OR REMOVEPRESSURE VESSEL FROM VESSEL.
Condition: Unknown
Due 6 June 1985
Resolved 6 June 1985
Engineering
Issued 6 June 1985 Resolved
PROVIDE FACTORY (DAHL) APPROVED FIRE SHIELDS FOR 2 DAHL M.D.E. FUEL FILTERS.
Condition: Unknown
Due 6 June 1985
Resolved 6 June 1985
Engineering
Issued 17 April 1985 Resolved
PROVIDE SUCTION STRAINER ON FORWARD BUNK ROOM BILGE SUCTION.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Construction/Loadline
Issued 17 April 1985 Resolved
WELD BULKHEAD PENETRATIONS WHERE HYDRAULIC LINES PASS BETWEEN ENGINE ROOM AND FISHTANK.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Construction/Loadline
Issued 17 April 1985 Resolved
STRAIGHTEN AND REWELD UPPER TO LOWER SECTIONS OF NO.1 STARBOARD TRANSVERSE FRAME IN FOREPEAK.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Construction/Loadline
Issued 17 April 1985 Resolved
WELD NO.3 TRANSVERSE DEEP FRAME, STARBOARD SIDE OF FOREPEAK, TO SIDE LONGITUDINAL AT TOP.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Construction/Loadline
Issued 17 April 1985 Resolved
REWELD NO.5 TRANSVERSE DEEP FRAME, PORT SIDE OF FOREPEAK, TOP AND BOTTOM, TO SIDE LONGITUDINAL.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Construction/Loadline
Issued 17 April 1985 Resolved
REPLACE 2 MISSING DOGS ON WATERTIGHT HATCH TO FORWARD BUNK ROOM.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Engineering
Issued 17 April 1985 Resolved
MARK LOCATION OF FOREPEAK SUCTION VALVE IN FORWARD BUNK ROOM.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.