MAURY USCG vessel records Sign in
← All vessels

POSIDON

POSIDON is a 1997 freight ship. The Coast Guard has recorded 24 inspections since 1997, most recently in September 2011, along with 9 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 1997 to 2011. Most recent: operational control imposed, 19 September 2011.

Built
1997
Last inspected
18 September 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9134804 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
462211
Flag
LIBERIA
—
Maury page id
psix-462211

Inspections, by type

…with no type recorded12
Years with a record 11 calendar years (1997–2011)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it6486 - Convention (Subpart B), Net Ton
13781 - Convention (Subpart B), Gross Ton
20375 - Dead Weight, Ton
26775 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

18 September 2011 Deficiency Check · In-Service Inspection · ISM Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4148239
18 September 2011 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4149288
14 September 2011 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4145032
12 September 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4143340
1 October 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3067293
18 September 2007 NPV Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3060324
11 October 2006 Ballast Water Examination · MARPOL Annex V Examination · NPV Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2797889
6 October 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2795362
17 January 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2567835
17 March 2005 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2312961
11 November 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2239315
10 November 2004 MARPOL Annex I Examination · MARPOL Annex V Examination · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2239026
8 June 2004 MTSA/ISPS Verification · Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2093223
3 June 2004 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2088359
29 March 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2033532
3 July 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1834784
29 April 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1782862
26 February 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1488315
9 December 2001 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 296187
24 January 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 286584
24 January 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 287596
28 January 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 274259
19 March 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 426558
24 November 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 410117

Deficiency record · 9

Engineering › Fuel Oil Service System › Piping
Issued 20 September 2011 Resolved
The main source of electrical power shall consist of at least two generating sets. The number 1 and number 2 generators do not function as designed. Vessel will supply report that generators operate at rated load of 435 KW. Specific Cite: SOLAS 74 (2009 Cons.) II-1/41.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2011
Resolution: Vessel was attended by class and found to be satisfactory. A class report has been, received attesting to the repairs.
Engineering › Generator (propulsion/auxiliary-electric) › Bus
Issued 18 September 2011 No resolution recorded
VSL has 02 disel generators rated at 435kW each. Both Generators could not achieve 435kW. Deficiency was issued for both Generators to function as designed with an achievable maximum load of 435kW per generator prior to return to the United States after sailing foreign.
Action required: 15 - Rectify deficiencies by next port
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 October 2006 Resolved
THE VESSEL WAS GRANTED A DEVIATION TO ENTER THE PORT FOR A INOPERATIVE STANDARD X BAND RADAR AND AT THE TIME OF THE INSPECTION THE RADAR WAS STILL INOPERATIVE. PROVIDE TECHNICIAN'S REPORT ATTESTING TO THE PROPER OPERATION OF THE RADAR.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2006
Resolution: Received report from Radio Holland: All control are functioning normal. Reset the TX time to zero for new magnetron. The radar is fully operational.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 26 February 2002 Resolved
Insufficient food rations in lifeboat. Vacuum seal had been broken on most/all food rations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2002
Resolution: Vessel ordered more food rations and provided receipt to MSO San Francisco.
Accommodation/Occupational Safety
Issued 24 January 2001 Resolved
MAKE PROPER REPAIRS TO SELF CLOSING DOOR MECHANISMS (3 TOTAL) PRIOR TO RETURN FROM SAILING FOREIGN. SOLAS CH. II-2, REG. 47
Condition: Unknown
Due 10 December 2001
Resolved 10 December 2001
Navigation
Issued 19 March 1999 Resolved
Provide a copy of the U.S. Inland Nav Rules on board vessel.
Condition: Unknown
Due 22 March 1999
Resolved 23 March 1999
Navigation
Issued 19 March 1999 Resolved
Provide a copy of the current tide tables for the U.S.
Condition: Unknown
Due 18 April 1999
Resolved 23 March 1999
Lifesaving
Issued 19 March 1999 Resolved
Provide a hydrostatic release for all life rafts on board. All expired in Jan of 99.
Condition: Unknown
Due 22 March 1999
Resolved 23 March 1999
Accommodation/Occupational Safety
Issued 19 March 1999 Resolved
Provide electrical matting on the deck infront of electrical pannel in the emergency generator room.
Condition: Unknown
Due 22 March 1999
Resolved 23 March 1999

Ownership record