FAVORS is a 1963 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 1999, most recently in July 2022, along with 31 deficiencies.

Records from 1999 to 2022. Most recent: inspection, 17 July 2022.

Built
1963
Last inspected
17 July 2022
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY9190
462216
Flag
UNITED STATES
367386760 (licence lapsed)
Maury page id
psix-462216

Inspections, by type

…with no type recorded1
Years with a record 14 calendar years (1999–2022)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.0 ft × 11.9 ft × 6.3 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHRIS-CHRAFT CORP · HOLLAND MI · built 1963
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHOLLAND, NY
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 26 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY9190MMSI 367386760 · expired · compulsorily equipped · granted 4 December 2008, cancelled 4 May 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 17

17 July 2022 Type not recorded
No type recorded · Station Buffalo · USCG Great Lakes District (CGD-GL) · Activity 7509209
11 July 2016 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5936835
5 August 2014 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4944832
8 December 2011 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4204282
6 July 2011 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4071701
1 April 2008 DAPI Audit · Drydock Exam · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3175108
19 June 2007 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2966955
21 May 2007 COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2934048
6 June 2006 Annual Inspection · Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2673882
8 June 2005 Periodic Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2434182
28 May 2004 Re-Inspection · Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2080861
19 June 2003 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1820570
3 June 2002 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1625488
30 July 2001 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1069790
18 July 2001 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1370295
29 June 2000 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1369754
8 June 1999 Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1467615

Deficiency record · 31

Lifesaving › Lifefloat › Retroreflective Material
Issued 5 August 2014 Resolved
Renew retro tape on life float.
Action required: 705 - Other - as specified
Due 13 August 2014
Resolved 15 August 2014
Resolution: Witnessed satisfactory installation.
Lifesaving › Lifefloat › Paddle
Issued 5 August 2014 Resolved
Provide suitable paddles marked and secured within float.
Action required: 705 - Other - as specified
Due 13 August 2014
Resolved 15 August 2014
Resolution: Witnessed satisfactory installation.
Lifesaving › Lifefloat › Serviceable
Issued 5 August 2014 Resolved
Make repairs to life float IAW manufactures procedures with suitable material.
Action required: 705 - Other - as specified
Due 13 August 2014
Resolved 15 August 2014
Resolution: Witnessed satisfactory repairs. Due to numerous repairs suggested owner consider new installation in near future.
Lifesaving › Lifefloat › Serviceable
Issued 6 July 2011 Resolved
Make proper repairs to cracking on Lifefloat.
Action required: 705 - Other - as specified
Due 20 July 2011
Resolved 20 July 2011
Lifesaving › Lifefloat › Retroreflective Material
Issued 6 July 2011 Resolved
Renew retro tape on Lifefloat.
Action required: 705 - Other - as specified
Due 20 July 2011
Resolved 20 July 2011
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 July 2011 Resolved
Replace waterlight lanyard (18') with UV resistant polyprop. line.
Action required: 705 - Other - as specified
Due 20 July 2011
Resolved 20 July 2011
Lifesaving › Lifefloat › Paddle
Issued 6 July 2011 Resolved
Re-lash paddles to facilitate quick release.
Action required: 705 - Other - as specified
Due 20 July 2011
Resolved 20 July 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 July 2011 Resolved
Tighten fittings on generator strainer housing.
Action required: 705 - Other - as specified
Due 20 July 2011
Resolved 20 July 2011
Construction/Loadline › Hull › Bracket
Issued 6 July 2011 Resolved
Weld bracker on port rudder packing gland support.
Action required: 705 - Other - as specified
Due 20 July 2011
Resolved 20 July 2011
Construction/Loadline › Hull › Bottom Plating
Issued 1 April 2008 Resolved
C/R both the port and starboard side of bottom plating IWO keel, from 5 foot aft of the turn of bow aft to good metal. Inserted plates must rise a minimum of 12 inches from keel and be provided to good metal proven by gauge readings.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2008
Resolved 7 May 2008
Resolution: New plating inserted from 5 foot from turn of bow to 12 foot rising on both sides 12 inches with gauge reading taken prior to insert fit-up inspection. Completed satisfactory soapy water test on all welds.
Engineering › Bilge Water Management System › Valve
Issued 1 April 2008 Resolved
Install positive shut off valves for all bilge discharge lines and two additional lines installed less than 3 inches from water line.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2008
Resolved 7 May 2008
Resolution: Ball valves installed for all required lines.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 April 2008 Resolved
Correct wiring for fff system which runs aft along center line, wire rest on light fixture and unsupported for the entire length.
Action required: 705 - Other - as specified
Due 24 June 2008
Resolved 24 June 2008
Resolution: Wire re-routed away from light and properly supported. Corrected prior to my departure.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 April 2008 Resolved
The installed engine room light fixture must be installed IAW 46 CFR 183.410. Remove screw supported porcelain fixtures and install approved assemblies.
Action required: 705 - Other - as specified
Due 24 July 2008
Resolved 2 June 2009
Resolution: Lights removed from within space.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 May 2007 Resolved
attach lifeline to ring buoy vice grab line of ring buoy within 30 days
Due 21 May 2007
Resolved 21 May 2007
Resolution: corrected prior to the completion of the inspection
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2007 Resolved
replace required first aid kit items within 30 days
Due 21 June 2007
Resolved 20 June 2007
Resolution: First aid items replaced appropriately in first-aid kit.
Engineering › Bilge Water Management System › Pump
Issued 6 June 2006 Resolved
Properly secure bilge pumps in forward compartment and in engine room.
Action required: 705 - Other - as specified
Due 6 June 2006
Resolved 6 June 2006
Resolution: Pumps properly mounted within bilge.
Lifesaving › Lifeboat Equipment
Issued 28 May 2004 Resolved
Replace expired battery in EPIRB.
Due 7 June 2004
Resolved 8 June 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 28 May 2004 Resolved
Conduct Hydro test on two B-II extinguishers. LEGACY COMPONENT DESC: Service
Due 7 June 2004
Resolved 8 June 2004
Electrical › Lighting (service)
Issued 28 May 2004 Resolved
Remove/replace solid core electrical wire for engine room lights.
Due 28 June 2004
Resolved 8 June 2004
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 19 June 2003 Resolved
Replace newly installed "Global" flexible fuel lines with flexible fuel lines that meet SAE standard J-1942.
Due 19 July 2003
Resolved 2 July 2003
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 3 June 2002 Resolved
Obtain current inland navigation rules.
Condition: Unknown
Due 30 June 2002
Resolved 5 June 2002
Lifesaving › Hand Flares › Quantity
Issued 3 June 2002 Resolved
Provide 3 orange day smoke flares.
Condition: Unknown
Due 30 June 2002
Resolved 5 June 2002
Engineering › Bilge Water Management System › Strainer
Issued 3 June 2002 Resolved
Clean forward bilge strainer.
Condition: Improper/Lack of Maintenance
Due 30 June 2002
Resolved 5 June 2002
Navigation
Issued 3 June 2002 Resolved
Replace bow mooring lines. LEGACY COMPONENT DESC: Mooring lines
Condition: Unknown
Due 30 June 2002
Resolved 12 June 2002
Construction/Loadline › Structures › Superstructure
Issued 3 June 2002 Resolved
Replace bridge window starboard side using safety glass as required.
Condition: Unknown
Due 30 June 2002
Resolved 5 June 2002
Construction/Loadline › Hull
Issued 3 June 2002 Resolved
Repair glass in starboard port light.
Condition: Unknown
Due 30 June 2002
Resolved 5 June 2002
Documentation › Markings/Placards › Oil Discharge Placard
Issued 3 June 2002 Resolved
Provide oil pollution placard.
Condition: Unknown
Due 30 June 2002
Resolved 5 June 2002
Construction/Loadline › Hull
Issued 3 June 2002 Resolved
Prior to next operating season install a hinged dead light cover on Port Light in accordance with 46 CFR 179.350(b).
Condition: Unknown
Due 1 October 2002
Resolved 19 June 2003
Accommodation/Occupational Safety
Issued 29 June 2000 Resolved
DISABLE OVERBOARD DISCHARGE CAPABILITY OF MARINE SANITATION DEVICE
Condition: Unknown
Due 29 June 2000
Resolved 29 June 2000
Electrical
Issued 29 June 2000 Resolved
INSTALL COVERS ON BATTERIES IN ENGINE ROOM
Condition: Unknown
Due 29 June 2000
Resolved 29 June 2000
Electrical
Issued 29 June 2000 Resolved
repair 2 broken light fixtures (110 volt AC) in engine room
Condition: Unknown
Due 29 June 2000
Resolved 29 June 2000

Ownership record