EASTERN STAR is a 1969 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1985, most recently in April 2025, along with 487 deficiencies — 2 with no resolution recorded —, 2 operational controls, 1 with no removal date recorded and 3 casualty investigations between 2004 and 2009.

Records from 1985 to 2025. Most recent: inspection, 22 April 2025.

Built
1969
Last inspected
22 April 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDH2000
Flag
UNITED STATES
366823950, 367553620, 367593370 (licence lapsed)
Maury page id
psix-46223

Inspections, by type

…with no type recorded13
Years with a record 36 calendar years (1985–2025)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)73.4 ft × 23.3 ft × 8.8 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)73.4 ft × 23.3 ft × 8.8 ft
ITC tonnagegross 135 / net 40
BuilderA. W. COVACEVICH SHIPYARD · BILOXI, MS, UNITED STATES · built 1969
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
135 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
40 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH2000MMSI 367593370 · expired · compulsorily equipped · granted 25 October 2013, cancelled 30 December 2023
WDG6111MMSI 367553620 · expired · compulsorily equipped · granted 15 November 2012, cancelled 21 January 2023
WDA5797MMSI 366823950 · expired · compulsorily equipped · granted 24 August 2001, cancelled 29 October 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 87

22 April 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8116700
7 January 2025 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8059633
9 July 2024 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7954175
6 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7705055
18 January 2023 Deficiency Check · Examination of Repairs · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7623654
17 August 2022 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7536800
18 May 2021 Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7199458
2 June 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7084992
8 November 2019 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6862374
27 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6587466
1 November 2018 Deficiency Check · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6573136
2 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6299505
27 October 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339645
6 December 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6054400
1 August 2016 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5959166
1 December 2015 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6155270
10 October 2014 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5015180
26 July 2011 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4094613
28 October 2010 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3893081
25 October 2010 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3876881
4 February 2009 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3412220
25 November 2008 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3369050
25 November 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3370026
9 October 2008 Drydock Exam · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3347876
23 September 2008 In-Service Inspection · Excursion Permit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3331798
28 March 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2897907
25 July 2006 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2727915
27 April 2006 Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2635141
18 April 2006 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2627138
30 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2610419
25 July 2005 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2438923
19 May 2005 Internal Structural Exam · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2362371
10 December 2004 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2261074
11 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2246180
5 October 2004 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2214082
3 October 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2211944
2 August 2004 MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2130865
4 December 2003 Deficiency Check · In-Service Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1958647
19 August 2003 MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1880838
5 May 2003 Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1786688
14 January 2003 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1730056
28 October 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1698535
21 October 2002 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1688447
20 October 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1694411
15 July 2002 Inclining Experiment · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1647661
3 June 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1625547
29 May 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1622984
15 August 2001 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1069718
27 July 2001 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1387082
24 July 2001 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1067285
8 June 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1076316
7 May 2001 Type not recorded
No type recorded · Station Elizabeth City · USCG East District (CGD-E) · Activity 1520245
28 July 1998 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1130433
5 November 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 783833
5 November 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1119979
10 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192455
13 July 1995 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 870673
13 July 1995 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 881647
26 May 1995 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1360174
26 May 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869146
26 May 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869299
15 September 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1150644
21 May 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1145956
28 April 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827114
16 December 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 837780
29 May 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 947885
24 May 1991 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941415
18 January 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907503
7 May 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 917533
13 April 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1215352
28 July 1989 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1208375
25 July 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 896746
25 July 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1208495
20 July 1989 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346965
26 April 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039332
26 April 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1201951
24 April 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1347812
11 July 1988 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033146
20 April 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034249
11 April 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339521
6 April 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1324982
6 April 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329443
6 June 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301168
21 January 1986 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1303064
19 September 1985 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 990173
8 May 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1291735
29 January 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 975234

Deficiency record · 487

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 July 2024 No resolution recorded
Each vessel inspected and certificated under the provisions of subchapter T must, when passengers are onboard during the tenure of the certificate, be in full compliance with the terms of the certficate. Vessel is taking on water, electric bilge pump set up in 2nd Void is pumping approximately 1 gal/min. 1)Provide repair plan to address water ingress 2)Conduct an inspection by USCG demonstrating vessel is in compliance with COI.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. While conducting operational test, MI discovered a steady leak coming from a fitting on the port engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2023
Resolution: Vessel replaced the loose fitting found on the port engine. During operational test, engine did not leak.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 18 January 2023 Resolved
FWD passenger cabin port side Clean rot on hull in fwd cabin port of keel from garbor plank to 6th plank. Make available for re-inspection
Action required: 705 - Other - as specified
Resolved 6 June 2023
Resolution: repaired to satisfaction of attending MI
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 18 January 2023 Resolved
STBD Side Engine Room - Re-fasten 2nd futtocks from fwd bulkhead
Action required: 705 - Other - as specified
Resolved 6 June 2023
Resolution: repaired to satisfaction of attending MI
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 18 January 2023 Resolved
STBD Sidem Engine Room - Provide repair plan for overhead deck in way of galley (rot)
Action required: 705 - Other - as specified
Resolved 6 June 2023
Resolution: repaired to satisfaction of attending MI
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 January 2023 Resolved
top deck - Stbd railing is loose - re-secure stanchions and bulkwork as needed
Action required: 705 - Other - as specified
Resolved 7 April 2023
Resolution: repaired to satisfaction of attending MI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 August 2022 Resolved
All hatches exposed to the weather must be watertight. A hatch cover must have securing devices and be attached to the hatch frame or coamings by hinges, captive chains, or other devices of substantial strength to prevent its loss. MI discovered that a hatch did not have a securing device attached.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2022
Resolved 19 September 2022
Resolution: Chains added.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 August 2022 Resolved
Each fire hose/nozzle must have fittings of brass or other suitable corrosion-resistant material that comply with NFPA 1963. MI discovered that the vessel’s fire hose nozzle was constructed of plastic material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2022
Resolved 19 September 2022
Resolution: Replaced w/ brass fittings
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 May 2021 Resolved
Provide servicing documentation for fixed firefighting system CO2 bottle and hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2021 Resolved
Repair exhaust leak in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2021 Resolved
Replace forward firehose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 May 2021 Resolved
Properly blank 02 seacocks in engineroom without hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2021 Resolved
Provide copies of valid and current Drug and Alcohol Program documentation for the vessel and crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2021 Resolved
Purchase 03 hand orange distress signals approved in accordance with 46 CFR 160.037.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 18 May 2021 Resolved
Refasten plank on transom above generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021 Resolved
Replace 03 ring light buoys approved in accordance with 46 CFR 160.050.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 18 May 2021 Resolved
Repair loose handrails on bow ladder leading to upper deck, upper deck port and starboard outboard of pilothouse, port aft upper deck handrail adjacent to the transom, upper deck transom, upper deck aft ladder leading to lower deck, and upper deck starboard under canopy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 May 2021 Resolved
Engineroom aft bulkhead had gap between starboard sideshell, make watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 May 2021 Resolved
Install handrail or harness system on rescue platform for crew to secure to vessel during man overboard recovery operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 May 2021 Resolved
Acquire updated navigation charts for areas the vessel will operate in as well as update required publications.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 May 2021 Resolved
Post copy of COI in passenger accommodation space - all pages must be visible. Post copy of stability letter in pilothouse - all pages must be visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2021 Resolved
Post lifejacket donning instructions on upper deck. Install lifejacket stowage labels for main deck forward stowage space inside the skin of the ship, and aft main deck lifejacket stowage space. Correct lifejacket stowage count labels on upper deck port and starboard side where 11 lifejackets are stowed. Correct child lifejacket stowage count label on bow to reflect 09 stowed in space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 18 May 2021 Resolved
Install missing portlight deadcover on port side main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021 Resolved
Install outlet cover on upper deck port electrical outlet. Rectify dead end cables in pilothouse, main deck port side concession area, and port side main deck overhead in space opposite the galley entrance.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 November 2019 Resolved
Provide updated DAPI enrollment letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2019
Resolution: Enrollment letter has been updated.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 November 2019 Resolved
C02 service report indicated one of the two bottles had 25lbs of CO2, recharge the bottle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2019
Resolution: A new CO2 bottle has been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2019 Resolved
2nd and 3rd void remove dead end wires and corroded AC chill water pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2019
Resolution: dead wires and corroded AC chill water pumps were removed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 8 November 2019 Resolved
Repair rotted deck and 2nd void aft watertight bulkhead stbd side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2019
Resolution: Rotted wood has been replaced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 November 2019 Resolved
Replace the gas detector for the galley.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2019
Resolution: The gas detector has been replaced in-kind with an new sensor and alarm panel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 8 November 2019 Resolved
Refasten port side shell frames in the laz.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2019
Resolution: Frames were refastened.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 November 2018 No resolution recorded
Vsl is broadcasting Draft > than Beam
Condition: Invalid
Action required: 705 - Other - as specified
Fire Fighting › Fire Main › Condition
Issued 1 August 2016 Resolved
The piping on the discharge side of the pump is damaged, replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2016
Resolution: Received photos of the repaired pipe from the master.
Fire Fighting › Fire Main › Material
Issued 1 August 2016 Resolved
The cross over valve between the bilge pump is frozen closed. Replace / Repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2016
Resolution: The valve was replaced.
Construction/Loadline › Hull › Hull Plating
Issued 1 August 2016 Resolved
The deck forward of the house is becoming soft. Replace
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: The deck was replace forward of the house.
Electrical › Electric Supply System (service) › Cable
Issued 10 October 2014 Resolved
Secure wires with metal hangers throughout the vessel (E/R, Laz, crew quarters).
Due 7 November 2014
Resolved 17 November 2014
Resolution: Received photos from the Captain of metal hangers on the wire runs.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 October 2014 Resolved
Install face plates on all outlets.
Due 24 October 2014
Resolved 24 October 2014
Resolution: Attended vessel, verified outlets had face plates installed.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 10 October 2014 Resolved
Install a CO detector in way of the wood stove.
Due 24 October 2014
Resolved 24 October 2014
Resolution: Attended vessel, CO detector was installed IWO the wood stove.
Engineering › Steering Gear System › Hydraulic Hose
Issued 10 October 2014 Resolved
Support the hydraulic hoses for the steering system in the laz.
Due 24 October 2014
Resolved 24 October 2014
Resolution: Attended vessel, hydraulic hoses are supported.
Communications › Audible Communications › Horn/Whistle
Issued 10 October 2014 Resolved
Replace the air compressor in the forward compartment.
Due 24 October 2014
Resolved 24 October 2014
Resolution: Attended vessel, the air compressor for the horn was replaced.
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 July 2011 Resolved
Conduct fire and man overboard drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: Conducted satsifactory fire and man overboard drills.
Engineering › Bilge Water Management System › Not Operational
Issued 26 July 2011 Resolved
Prove operation of bilge dewatering system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: Verified proper operation of bilge dewatering system.
Engineering › Fuel Oil Service System › Filter
Issued 26 July 2011 Resolved
Remove fuel from battery casing, starboard battery under fuel filters.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: All fuel verified removed from battery casings.
Engineering › Bilge Water Management System › Not Operational
Issued 26 July 2011 Resolved
Clean all fuel and oil from bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: All fuel and oil verified cleaned from bilges.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 26 July 2011 Resolved
Make temporary repair to exhaust leak on port exhaust pipe. Permanent repairs must be made prior to credit drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: Verified temporary repair to exhaust leak on port exhaust pipe.
Fire Fighting › Fire Main › Valves
Issued 26 July 2011 Resolved
Repair leak in aft fire main valve on port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: Aft fire main valve verified replaced with new valve.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 July 2011 Resolved
Secure hand rail near starboard forward cabin as discussed.
Due 2 August 2011
Resolved 28 July 2011
Resolution: Hand rail near starboard forward cabin verified properly secured.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 26 July 2011 Resolved
Properly secure fire extinguisher on upper deck on starboard side of bar.
Due 2 August 2011
Resolved 28 July 2011
Resolution: Portable fire extinguisher on upper deck verified properly secured.
Engineering › Bilge Water Management System › Piping
Issued 26 July 2011 Resolved
Double clamp flexible hoses on bilge system in engine room as discussed.
Due 2 August 2011
Resolved 28 July 2011
Resolution: Verified flexible hoses on bilge system in engine room properly double clamped.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 July 2011 Resolved
Provide eye-wash for first aid kit.
Due 2 August 2011
Resolved 28 July 2011
Resolution: Eye-wash for first aid kid provided.
Navigation › Piloting/Steering › Marine Charts
Issued 26 July 2011 Resolved
Provide most current notice to mariners and update charts.
Due 2 August 2011
Resolved 28 July 2011
Resolution: Most current notice to mariners provided.
Fire Fighting › Means of Escape › Blocked
Issued 26 July 2011 Resolved
Unblock all emergency escapes.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: All emergency escapes unblocked.
Construction/Loadline › Hull › Side Shell
Issued 26 July 2011 Resolved
Make repairs to wood around hausepipe, forward port side, prior to credit drydock.
Action required: 705 - Other - as specified
Due 31 October 2011
Resolved 18 November 2011
Resolution: Repairs were confirmed at credit drydock 2011.
Construction/Loadline › Structures › Machinery Space Opening
Issued 26 July 2011 Resolved
Remove all foam blocks in lazarette to make space available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: All foam blocks in lazarette removed, inspection conducted during deficiency check on 28July2011.
Construction/Loadline › Hull › Side Shell
Issued 28 October 2010 Resolved
Prior to credit dry dock, vessel must conduct underway examination with USCG Marine Inspectors. 12NOV10: Underway exam could not be completed due to excessive water in the Lazerette space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2010
Resolution: Conducted underway examination. Inspected all bilges and planking below the main deck for leaks. Structure at the time of this inspection appeared to be sound.
Construction/Loadline › Hull › Side Shell
Issued 28 October 2010 Resolved
There is a 1/8 - 1/4 inch hole (from a drill bit...the owner claimed he used this method to locate the frame from the outside) next to a re-newed frame in the engine room side shell on the portside below the waterline right above the chine, as identified. Vessel must submit a temporary repair and a permanent repair proposal to the Coast Guard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2010
Resolution: Vessel installed a tampered dowel w/ 5200 sealant and mahogany butt plate as a temporary patch. Vessel is required to make a permanent repair no later than 31OCT2011.
Engineering › Bilge Water Management System › Not Operational
Issued 25 October 2010 Resolved
The vessel's bilge dewatering system is not working when tested. The probable cause is a bad union connection located in the crew space. Vessel must repair dewatering line and demonstrate proper operation to a Coast Guard Marine Inspector. 46CFR176.804(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2010
Resolution: Vessel replaced bad impeller and demonstrated proper operation of the bilge dewatering system.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 25 October 2010 Resolved
There are numerous loose railings on the main & upper deck. These railings in this condition will not support passengers or crew. Vessel must tighten up and secure all railings. 46CFR177.900
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2010
Resolution: All railings on both the lower and upper deck were properly secured.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 October 2010 Resolved
Vessel was unable to conduct an underway man overboard drill due to not having an additional deck hand as required by the COI manning. Vessel must conduct a man overboard drill with a Coast Guard Marine Inspector. 46CFR176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2010
Resolution: Conducted a satisfactory man overboard drill.
Engineering › Bilge Water Management System › Not Operational
Issued 25 October 2010 Resolved
Vessel's engine room bilge forward of the main engines is filled with debris and oily water. This debris will hinder the proper operation of the bilge dewatering system and the oily water is a pollution hazard. Vessel must clean all bilges of debris and oily water. 46CFR176.830(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2010
Resolution: Bilges were cleaned of oily water and debris.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2010 Resolved
The engine rooms air conditioning pump's power cord is spliced into an electrical supply wire with "wire nuts". The use of screw or twist on type connectors is not authorized. Vessel must properly wire and secure this power cord. 46CFR183.340(i)(2)
Action required: 705 - Other - as specified
Due 1 November 2010
Resolved 12 November 2010
Resolution: Vessel properly wired and secured the power cord with butt end connectors.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 October 2010 Resolved
The high level water alarm in the Lazarette is not working. Vessel must repair or replace this high level alarm. 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2010
Resolution: Vessel replaced and demonstrated proper operation of high level alarm.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 October 2010 Resolved
The battery bank forward of the starboard main engine is open and un-protected. In this condition, the batteries are not properly secured or protected from any kind of liquid spray. Vessel must properly encase the batteries and all wires must be neatly secured. 46CFR183.350
Action required: 705 - Other - as specified
Due 8 November 2010
Resolved 12 November 2010
Resolution: Vessel properly secured and covered forward engine room battery bank.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 October 2010 Resolved
Vessel has three ring buoys. One ring buoy has a 30' line that is the incorrect type and sinks in the water. Vessel must replace life line with an approved 60' line IAW 46CFR180.70(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2010
Resolution: Vessel replaced life line with proper type and length.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 25 October 2010 Resolved
Vessel has flammable liquids and compressed 8oz butane fuel stowed below the main deck in an un-protected space. This space contains no fixed fire fighting and material is not properly stowed in an approved flammable locker. Vessel must remove all flammable liquids and compressed gases. 46CFR177.405(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2010
Resolution: Vessel removed all flammable liquids from the vessel.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 October 2010 Resolved
Vessel has three ring buoys. One ring buoy has an inoperable water light. Vessel must repair or replace water light. 46CFR180.70(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2010
Resolution: Vessel replaced batteries in water light and demonstrated proper operation.
Engineering › Bilge Water Management System › Valve
Issued 25 October 2010 Resolved
The positive action shut off valve for the electric submersible line in the fore peak space does not operate. This valve is stuck in the open position and will not close if needed in an emergency. Vessel must repair or replace this valve prior to credit dry dock this week. 46CFR182.520(e)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2010
Resolution: Vessel replaced valve with new and demonstrated proper operation.
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 25 November 2008 Resolved
Provide report from qualified technician detailing cause of loss of main propulsion.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2008
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 25 November 2008 Resolved
Make repairs to port and starboard main propulsion engines and conduct satisfactory sea trials of the same in the presence of a marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2008
Engineering › Steering Gear System › Ram Seal
Issued 24 October 2008 Resolved
Adjust port and stbd shaft packing.
Action required: 705 - Other - as specified
Due 24 November 2008
Resolved 19 December 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 October 2008 Resolved
Remove all oil and water from vessel bilges and provide proof of disposal of the same. **PTCP**
Action required: 705 - Other - as specified
Resolved 25 October 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 October 2008 Resolved
Secure exhaust cooling water leak port main exhaust.
Action required: 705 - Other - as specified
Due 24 November 2008
Resolved 19 December 2008
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 October 2008 Resolved
Determine cause of excess vibration in lazarette and conduct underway examination in presence of a marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 October 2008 Resolved
Secure electrical cable in way of sewage pump in lazarette (every 24").
Action required: 705 - Other - as specified
Due 24 November 2008
Resolved 19 December 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 October 2008 Resolved
Make permanent repairs to deck-railings on all sides of vessel.
Action required: 705 - Other - as specified
Due 30 October 2008
Resolved 24 October 2008
Construction/Loadline › Structures › Door
Issued 23 October 2008 Resolved
Address to USCG the coaming height requirements for French Doors.
Action required: 705 - Other - as specified
Due 30 October 2008
Resolved 30 October 2008
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 23 October 2008 Resolved
Make vessel ready for underway with a Marine Inspector.
Action required: 705 - Other - as specified
Due 30 October 2008
Resolved 24 October 2008
Documentation › Certificates/Documents › FCC SSL
Issued 9 October 2008 Resolved
Provide valid FCC Safety Radio Cert.
Action required: 705 - Other - as specified
Due 9 November 2008
Resolved 27 October 2008
Documentation › Certificates/Documents › FCC SSL
Issued 9 October 2008 Resolved
Provide Bridge to Bridge Radio Cert.
Action required: 705 - Other - as specified
Due 9 November 2008
Resolved 27 October 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 October 2008 Resolved
Provide Cg Light List (or excerpt) onboard vsl.
Action required: 705 - Other - as specified
Due 9 November 2008
Resolved 23 October 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 October 2008 Resolved
Remove or re-connect dead end wires in engine room, forepeak, and lazzerette.
Action required: 705 - Other - as specified
Due 9 November 2008
Resolved 23 October 2008
Engineering › Bilge Water Management System › Pump
Issued 9 October 2008 Resolved
Provide portable hand bilge pump onboard vsl.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2008
Resolved 23 October 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 9 October 2008 Resolved
Provide emergency exit sign from crew members accommodations.
Action required: 705 - Other - as specified
Due 9 November 2008
Resolved 23 October 2008
Engineering › Steering Gear System › Rudder
Issued 28 March 2007 Resolved
Make repairs to excessive pitting in starboard rudder at rudder/stock interface. (Grind, v-notch, re-weld)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: Pitting removed/repaired.
Engineering › Steering Gear System › Rudder Stock
Issued 28 March 2007 Resolved
Replace port rudder and rudder stock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: New rudder installed.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 28 March 2007 Resolved
Replace screen in way of generator cooling water intake, starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: Screens replaced on both port and stbd intakes.
Construction/Loadline › Hull › Transverse Frame
Issued 28 March 2007 Resolved
Replace 2nd frame fwd of collision bulkhead, port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: Satisfactory installation of scarfed frame.
Engineering › Sea-water System (primary cooling) › Valve
Issued 28 March 2007 Resolved
Repair/replace frozen ball valve in way of port main engine cooling water intake.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: Tested ball valve, operation satisfactory.
Fire Fighting › Fire Pumps › Suction Valve
Issued 28 March 2007 Resolved
Remove sea water intake valve in way of port fire pump and make ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: Valve replaced with new ball valve, operation satisfactory.
Electrical › Electric Generation Source (service) › Generator
Issued 28 March 2007 Resolved
Replace cracked flexible hose in way of port generator exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: Hose replaced and double clamped w/ approved material.
Electrical › Electric Generation Source (service) › Generator
Issued 28 March 2007 Resolved
Double clamp port and starboard generator exhaust hose in lazerette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: Hose clamps provided.
Construction/Loadline › Hull › Transverse Frame
Issued 28 March 2007 Resolved
Remove rotted frame 1st from stern, port side and make planks directly behind available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: 1st frame sister removed. Transom frame and adjacent planks are in sound condition. Instructed vsl rep to remove more of sister to good wood and install new piece accordingly.
Construction/Loadline › Hull › Transverse Frame
Issued 28 March 2007 Resolved
Replace through bolts in frame port and starboard side, located in crew quarters directly below head doors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: New bolts sat.
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 28 March 2007 Resolved
Repair cracked PVC piping in way of grey water system, in crew quarters.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: New PVC installed.
Construction/Loadline › Hull › Transverse Frame
Issued 28 March 2007 Resolved
Replace through bolts in Cabin C, port side, 1st and 2nd frame, aft of bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: New through bolts sat.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 28 March 2007 Resolved
Double clamp wet exhaust hose on starboard main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: Clamps installed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 March 2007 Resolved
Scrape back to good wood and treat longitudinal frame beneath starboard generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: Frame and adjacent stringer treated and are in sound condition.
Electrical › Electric Generation Source (service) › Generator
Issued 28 March 2007 Resolved
Replace and double clamp cracked wet exhaust hose in way of starboard generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: Hose replaced and double clamped w/ approved material.
Construction/Loadline › Hull › Transverse Frame
Issued 28 March 2007 Resolved
Replace through bolt, 2nd frame inboard from starboard side in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: New throughs bolt sat.
Construction/Loadline › Hull › Transverse Frame
Issued 28 March 2007 Resolved
Replace decayed futtock, 2nd frame from transom, starboard side, lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Resolution: New futtock installed.
Documentation › Logs/Records › Logbook (official)
Issued 25 July 2006 Resolved
Ensure proper documentation/log training and drills.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 18 September 2006
Resolution: Drills and training recorded in log book.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 25 July 2006 Resolved
Provide life jacket donning instructions for both style life jackets.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Donning instructions posted.
Stability › Incline Test › General
Issued 25 July 2006 Resolved
Provide documentation that canopy on upper deck was included in stability test (stability letter dated 02 DEC 2003), or remove canopy, or conduct stability test, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2006
Resolution: Canopy has been removed from vessel. Special note added to ensure canopy is not installed again without a new stability test.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 25 July 2006 Resolved
Post CO2 instructions for fixed extinguishing system aft at operating station.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Instructions posted.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 25 July 2006 Resolved
Permanently affix propane sensor to fixed location.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2006
Resolution: Sensor permanently mounted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2006 Resolved
Place splice in wiring for propane sensor in enclosure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2006
Resolution: Splice placed in junction box.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 July 2006 Resolved
Re-attach rails and lines, port and starboard side, main deck.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 27 July 2006
Resolution: Rails/lines re-attached.
Engineering › Bilge Water Management System › Pump
Issued 25 July 2006 Resolved
Prove proper operation of fixed bilge pumping system in the presence of a USCG Marine Inspector, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2006
Resolution: Witnessed satisfactory operation of bilge pump.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 July 2006 Resolved
Double clamp flex hose on wet exhaust, starboard side, aft.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Double clamps installed.
Stability › Watertight Integrity › General
Issued 25 July 2006 Resolved
Make engine room bulkhead penetrations watertight, starboard side, forward bulkhead.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 30 August 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 25 July 2006 Resolved
Double clamp flex hose on wet exhaust, port generator (also re-clamp on top side).
Due 9 August 2006
Resolved 9 August 2006
Resolution: Double clamps installed.
Stability › Watertight Integrity › General
Issued 25 July 2006 Resolved
Make engine room bulkhead penetrations watertight, port side, aft bulkhead.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Bulkhead penetrations sealed.
Engineering › Fuel Oil Service System › Hose
Issued 25 July 2006 Resolved
Replace cracked fuel return hose on starboard engine with approved hose IAW J-1942.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Hose replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2006 Resolved
Make wiring on sewage pump a secure/permanent connection.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: New pump installed, wiring sat.
Engineering › Fuel Oil Service System › Piping
Issued 25 July 2006 Resolved
Mount fuel oil supply pipe on starboard generator to prevent movement.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Supply pipe securely mounted.
Engineering › Fuel Oil Service System › Hose
Issued 25 July 2006 Resolved
Replace worn fuel oil supply line on starboard generator.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Supply line replaced.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 25 July 2006 Resolved
Tighten shaft seal on starboard shaft, water is continuously leaking into bilge.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Shaft seal secured from excessive leaking.
Engineering › Fuel Oil Service System › Valve
Issued 25 July 2006 Resolved
Ensure fuel oil shut-off valves shut completely closed.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 30 August 2006
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 25 July 2006 Resolved
Replace starboard main engine water supply line, prior to carrying passengers. Hose is worn/cut.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2006
Resolution: Hose replaced.
Engineering › Fuel Oil Service System › Piping
Issued 25 July 2006 Resolved
Replace fuel oil supply and return lines on port side.
Action required: 705 - Other - as specified
Due 27 August 2006
Resolved 30 August 2006
Resolution: Fuel oil lines replaced.
Stability › Watertight Integrity › General
Issued 25 July 2006 Resolved
Make bulkhead penetrations in forepeak watertight; above air compressor at deck and below air compressor.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 18 September 2006
Resolution: Forepeak penetrations made watertight.
Stability › Watertight Integrity › General
Issued 25 July 2006 Resolved
Secure hatch for forepeak with lanyard and attaching device.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 27 July 2006
Resolution: Hatch secured.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 25 July 2006 Resolved
Make propane supply line running along deck secured to prevent movement and damage by walking on deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2006
Resolution: Supply line secured.
Stability › Watertight Integrity › General
Issued 25 July 2006 Resolved
Make vessel available for underway inspection in the presence of a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 27 July 2006
Resolution: Underway inspection conducted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 July 2006 Resolved
Properly affix aft end of top rail, main deck, on port and starboard sides, to vessel.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Rails securely fastened.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2006 Resolved
Permanently attach power source to lifesaving apparatus.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Electrical connections permanently secured.
Engineering › Bilge Water Management System › Strainer
Issued 25 July 2006 Resolved
Remove debris in way of bilge strainer in forepeak.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Forepeak bilge cleaned.
Engineering › Bilge Water Management System › Hose
Issued 25 July 2006 Resolved
Double clamp overboard discharge from electric bilge pump in forepeak.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Double clamps installed.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 25 July 2006 Resolved
Install supporting bracket for starboard side engine sea water cooling line.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Support bracket installed.
Accommodation/Occupational Safety › Potable Water System › General
Issued 25 July 2006 Resolved
Permanently secure/mount fresh water tanks in engine room.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 30 August 2006
Resolution: Tanks permanently secured.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 25 July 2006 Resolved
Tighten shaft seal on port shaft, engine room.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Shaft seal tightened.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2006 Resolved
Replace plastic wire ties with metallic (approved) mounting for wires throughout engine room.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Metallic wire mounts installed
Accommodation/Occupational Safety › Potable Water System › General
Issued 25 July 2006 Resolved
Remove overboard discharge line from kitchen area that leads to overboard valve, port side aft, engine room, and properly connect to MSD system.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Deficiency removed, not required.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 25 July 2006 Resolved
Double clamp discharge lines from both toilet pumps to MSD system.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 30 August 2006
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 25 July 2006 Resolved
Properly mark emergency egress, and routes to them, with cabins C and E, prior to carrying passengers overnight.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 30 August 2006
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 25 July 2006 Resolved
Properly mark vessel with markings required by 46 CFR 185.602 at next drydock.
Due 30 May 2007
Resolved 4 September 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 July 2006 Resolved
Properly attach cover plate to electric outlet, bar area, main deck.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 9 August 2006
Resolution: Cover plate installed.
Construction/Loadline › Hull › Bottom Plating
Issued 25 July 2006 Resolved
Remove doubler plates, port and starboard sides, forepeak, at next drydock.
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 4 September 2007
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 25 July 2006 Resolved
Properly re-connect shower piping in crew quarters; 2nd compartment, to MSD system piping.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 18 September 2006
Resolution: Piping reconnected.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 July 2006 Resolved
Replace port side gate with one capable of supporting 200 lbs., prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2006
Resolution: Gate replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 July 2006 Resolved
Properly mount CO2 extinguisher in engine room, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2006
Resolution: CO2 extinguisher permanently mounted.
Stability › Watertight Integrity › General
Issued 25 July 2006 Resolved
Properly repair hatch gasket for forepeak hatch.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 18 September 2006
Resolution: Owner installed new hatch.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 25 July 2006 Resolved
Properly mount LPG tank locker on aft main deck, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2006
Resolution: LPG tank locker permanently mounted.
Engineering › Bilge Water Management System › Pump
Issued 25 July 2005 Resolved
Prove proper operation of fixed bilge system- suction from crew cabin space.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Resolution: System sat operation.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 25 July 2005 Resolved
Provide valid proof of drug and alcohol program
Condition: Unknown
Due 15 August 2005
Resolved 10 August 2005
Resolution: Received fax of confirmation of enrollment.
Documentation › Logs/Records › Logbook (official)
Issued 25 July 2005 Resolved
Provide valid bridge/training log
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Log provided.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 July 2005 Resolved
Properly stow gear adrift in crew cabin
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Gear stowed.
Engineering › Bilge Water Management System › Hose
Issued 25 July 2005 Resolved
Remove bucket from fwd crew cabin bilge space and cap off/close 03 drain lines
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Removed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 July 2005 Resolved
Conduct underway sea trials- wooden vessel
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Sea trials conducted, sat.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 25 July 2005 Resolved
Prove proper operation of propane gas detector located in galley- secure stove.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 3 August 2005
Resolution: Gas detector repaired.
Fire Fighting › Means of Escape › Blocked
Issued 25 July 2005 Resolved
Re-postition furniture in main passenger cabin space not to interfere with emergency exits.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Resolution: Emergency exits clear.
Documentation › Certificates/Documents › COW System Evidence of Installation
Issued 25 July 2005 Resolved
Provide copy of fixed fire fighting servicing certificate for USCG
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Received fax.
Lifesaving › Launching Appliances › Davit
Issued 25 July 2005 Resolved
Do not use Zodiak davit launch system until all mounting hardware is in place.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 3 August 2005
Resolution: Def moved to special note category.
Fire Fighting › Fire Pumps › Capacity
Issued 25 July 2005 Resolved
Repair leak in firefighting pump plumbing at seam as discussed with owner
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Leak repaired.
Fire Fighting › Fire Pumps › Arrangement
Issued 25 July 2005 Resolved
Properly mount/secure overboard discharge link for firefighting pump
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Properly repaired.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 July 2005 Resolved
Remove oily mixture from engine room bilge
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Removed.
Fire Fighting › Fire Hydrants › Condition
Issued 25 July 2005 Resolved
Repair leak at fwd firefighting station
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Leak repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2005 Resolved
Properly wire (12 volt) pumps in engine room for (02) airconditioning pumps
Condition: Unknown
Due 3 August 2005
Resolved 3 October 2016
Resolution: Wire properly re-installed.
Engineering › Fuel Oil Service System › Gauge
Issued 25 July 2005 Resolved
Repair MDE oil pressure gauge for S/S MDE
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Gauge repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2005 Resolved
Remove (homemade) electric lube oil servicing pump from engine room
Condition: Placed in Improper Service
Due 3 August 2005
Resolved 3 August 2005
Resolution: Removed.
Engineering › Steering Gear System › Linkage
Issued 25 July 2005 Resolved
Steering gear system not operating smoothly due to foam stored in lazarette. Properly re-stow/ align foam flotation located in lazarette void space as per stability letter stowage plan.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Resolution: Restowed foam, secured in plastic netting.
Electrical › Electric Supply System (service) › Cable
Issued 19 May 2005 Resolved
hardwire a/c units licated under beds, existing units are plugged into an outlet. (two remaining)
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 30 March 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 19 May 2005 Resolved
crew shower/sink drains into a five gallon bucket. remove bucket/secure shower or install an approved holding tank
Action required: 705 - Other - as specified
Due 6 September 2005
Resolved 30 August 2005
Resolution: Cleared by Sec NY
Stability › Incline Test › General
Issued 10 December 2004 Resolved
Required foam in lazzarette not properly IAW stability letter or 46 CFR 178.240. Make permanent and proper repairs at next dry dock but no latter than 30APR05
Condition: Placed in Improper Service
Due 30 May 2005
Resolved 25 July 2005
Resolution: Properly affixed & secured same IAW stability letter.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 10 December 2004 Resolved
Through hull fitting in lazarette fitted with check valve between hull and positive control valve. Re-locate positive closing valve as close as possible to the through hull fitting.
Condition: Placed in Improper Service
Due 30 April 2005
Resolved 25 July 2005
Resolution: Relocated same.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 December 2004 Resolved
Prove crew proficiency during man overboard drill utillizing rescue boat. Rescue platform not visible from operating station.
Condition: Improper/Lack of Maintenance
Due 10 December 2004
Resolved 10 December 2004
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 10 December 2004 Resolved
Prove proper operation of port MDE lube oil pressure gauge.
Condition: Improper/Lack of Maintenance
Due 10 December 2004
Resolved 10 December 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 December 2004 Resolved
Seperate adult and children life jackets in forward locker.
Condition: Placed in Improper Service
Due 10 December 2004
Resolved 10 December 2004
Fire Fighting › Fire Pumps › Pressure
Issued 10 December 2004 Resolved
Prove proper operation of fire pump. Operating at reduced pressure.
Condition: Placed in Improper Service
Due 10 December 2004
Resolved 10 December 2004
Fire Fighting › Fire Main › Condition
Issued 10 December 2004 Resolved
Make permanent repaire to leaks in firemain. Firemain is lead soldered and requires to be changed out to meet the standards of non ferrious piping. Fire main piping iregularities to be corrected at next dry dock.
Condition: Placed in Improper Service
Due 30 April 2005
Resolved 25 July 2005
Resolution: Permanent repairs made to same.
Fire Fighting › Fire Hydrants › Condition
Issued 10 December 2004 Resolved
Make permanent repairs to forward fire hydrant leaks.
Condition: Improper/Lack of Maintenance
Due 10 December 2004
Resolved 10 December 2004
Lifesaving › Lifebuoys › Serviceable
Issued 10 December 2004 Resolved
Replace grab lines on life rings.
Condition: Improper/Lack of Maintenance
Due 10 December 2004
Resolved 10 December 2004
Construction/Loadline › Structures › Deck Plating
Issued 10 December 2004 Resolved
Forepeak compartment overhead ond fore deck rotted and no longer safe for passengers. Make permanent repairs to deck at next dry dock but NLT 30APR05. Post signs closing deck forward of the accomadation space to all passengers.
Condition: Improper/Lack of Maintenance
Due 30 April 2005
Resolved 25 July 2005
Resolution: Permanent repairs made to same.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 December 2004 Resolved
Properly mount gauges located at power panel outside galley.
Condition: Improper/Lack of Maintenance
Due 10 January 2005
Resolved 25 July 2005
Resolution: Properly relocated same.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 10 December 2004 Resolved
Properly secure leads to stbd reduction gear RPM solinoid
Condition: Placed in Improper Service
Due 10 January 2005
Resolved 25 July 2005
Resolution: Properly secured same.
Lifesaving › Launching Appliances › Winch
Issued 10 December 2004 Resolved
Winch not rated for overhead lifting or hoisting personnel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 25 July 2005
Resolution: Transferred def to Special Notes.
Construction/Loadline › Hull › Hull Plating
Issued 2 August 2004 Resolved
Make proper repairs to damage on port side.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004
Resolved 5 August 2004
Resolution: Completed proper repairs IAW attending MI.
Stability › Watertight Integrity › General
Issued 2 August 2004 Resolved
Make proper repairs to collision bulkhead to prevent water from leaking into crew space.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2004
Resolved 16 September 2004
Engineering › Bilge Water Management System › Not Operational
Issued 2 August 2004 Resolved
Prove proper operation of installed bilge suction system in forpeak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004
Resolved 5 August 2004
Resolution: Completed proper repairs IAW attending MI.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 August 2004 Resolved
Prove proper operation of bilge high level alarm in lazzerett.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004
Resolved 5 August 2004
Resolution: Completed proper repairs IAW attending MI.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 August 2004 Resolved
Properly hang/secure all electrical wires throughout vessel.
Due 13 August 2004
Resolved 11 August 2004
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 2 August 2004 Resolved
Properly repair storm rail on stove and hook on oven door.
Due 13 August 2004
Resolved 5 August 2004
Resolution: Completed proper repairs IAW attending MI.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 2 August 2004 Resolved
Properly lable breakers in distribution panel in engine room.
Due 13 August 2004
Resolved 16 September 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 August 2004 Resolved
Properly repair leak in exhaust for Stbd. MDE.
Due 13 August 2004
Resolved 16 September 2004
Engineering › Lubricating Oil Service System › Hose
Issued 2 August 2004 Resolved
Locate and repair oil leak in Stbd. MDE
Due 13 August 2004
Resolved 11 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 August 2004 Resolved
Remove patch and properly repair elbow on Port MDE.
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 11 August 2004
Engineering › Freshwater Generation System › Piping
Issued 2 August 2004 Resolved
Properly repair leak in fresh water piping near fresh water pump.
Due 13 August 2004
Resolved 5 August 2004
Resolution: Completed proper repairs IAW attending MI.
Stability › Watertight Integrity › General
Issued 2 August 2004 Resolved
Make forpeak watertight around Samson post.
Due 6 August 2004
Resolved 11 August 2004
Stability › Watertight Integrity › General
Issued 2 August 2004 Resolved
Make collision bulkhead watertight in upper Stbd. corner
Due 6 August 2004
Resolved 5 August 2004
Resolution: Completed proper repairs IAW attending MI.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 August 2004 Resolved
Properly secure counter top in galley on the left side of the stove.
Due 13 August 2004
Resolved 5 August 2004
Resolution: Completed proper repairs IAW attending MI.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 August 2004 Resolved
Place covers on electrical boxes behind access cover behind Stbd rack in crew accomodations.
Due 13 August 2004
Resolved 16 September 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 August 2004 Resolved
Remove or have serviced all portable fire extinguishers in crew accomodations.
Due 13 August 2004
Resolved 5 August 2004
Resolution: Removed same IAW attending MI.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 2 August 2004 Resolved
Properly secure escape ladder in aft passenger cabin.
Action required: 705 - Other - as specified
Resolved 29 October 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 2 August 2004 Resolved
Properly secure portable fire extinguisher bracket in bar area on upper deck.
Due 6 August 2004
Resolved 16 September 2004
Fire Fighting › Fire Hydrants › Material
Issued 2 August 2004 Resolved
Provide spanner wrenches for fire stations.
Due 6 August 2004
Resolved 5 August 2004
Resolution: Completed proper repairs IAW attending MI.
Fire Fighting › Fire Hydrants › Condition
Issued 2 August 2004 Resolved
Properly repair fire station on stern.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004
Resolved 5 August 2004
Resolution: Completed proper repairs IAW attending MI.
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 2 August 2004 Resolved
Failed to notify the OCMI when the vessel was drydocked.
Due 2 August 2004
Resolved 26 October 2009
Resolution: Should not be an open def.
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 2 August 2004 Resolved
Failed to notify the OCMI of alterations made to the vessel's hull.
Due 2 August 2004
Resolved 26 October 2009
Resolution: Should not be an open def.
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 2 August 2004 Resolved
Failed to notify the nearest CG office of a marine casualty.
Due 2 August 2004
Resolved 26 October 2009
Resolution: Should not be an open def.
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 2 August 2004 Resolved
Operated in a negligent manner that endangered the life, limb or property of the persons onboard.
Due 26 October 2009
Resolved 26 October 2009
Resolution: Should not be an open def.
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 2 August 2004 Resolved
Failed to maintain vessel in compliance of its COI.
Due 2 August 2004
Resolved 26 October 2009
Resolution: Should not be an open def.
Fire Fighting › Fire Pumps
Issued 4 December 2003 Resolved
Fire pump is not rated for required pressure or capacity LEGACY COMPONENT DESC: Capacity
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2003
Resolution: New pump installed meeting required specifications.
Fire Fighting › Fire Main
Issued 4 December 2003 Resolved
Firemain system leaking at pipe connection from pump LEGACY COMPONENT DESC: Condition
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2003
Personnel › Training › Familiarization Training
Issued 4 December 2003 Resolved
Crew members unfamiliar with fire & bilge emergency system and procedures, additional training required
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2003
Resolved 5 December 2003
Lifesaving › Hand Flares › Condition
Issued 4 December 2003 Resolved
Flares have exceeded expiration date
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2003
Operations/Management › Equipment Service/Testing
Issued 4 December 2003 Resolved
Provide current service report for Fixed CO2 system LEGACY COMPONENT DESC: Fixed firefighting system
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2003
Resolved 5 December 2003
Electrical › Electric Generation Source (service) › Generator
Issued 4 December 2003 Resolved
Provide generator with 50 deg Centigrade rating or demonstrate E/R does not exceed 40 deg Centigrade or derate to 80% of rated capacity LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 2 March 2004
Resolved 29 October 2004
Resolution: Cleared as directed.
Engineering › Fuel Oil Storage/Transfer System
Issued 4 December 2003 Resolved
Demonstrate adequate integrity of F/O cock on bottom of starboard F/O service tank or replace in-kind LEGACY COMPONENT DESC: Tank
Due 15 January 2004
Resolved 15 January 2004
Resolution: valve and nipple were replaced.
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 4 December 2003 Resolved
Provide insulation for wood burning vertical stack in vicinity of accommodation stairway prior to using heating appliance LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Resolved 29 October 2004
Resolution: Cleared as directed
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 December 2003 Resolved
FWD bilge high level not functioning, demonstrate all high level alarms work satisfactory
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 December 2003 Resolved
Provide working J/W gauge for port MDE
Due 9 December 2003
Resolved 9 December 2003
Engineering › Freshwater System (cylinder head cooling)
Issued 4 December 2003 Resolved
Port MDE R/W supply hose is dry-rotted and requires replacement LEGACY COMPONENT DESC: Hose
Due 31 December 2003
Resolved 26 January 2004
Fire Fighting › Fire Hoses
Issued 4 December 2003 Resolved
Fire hose on aft deck is not satisfactorily stowed and requires a more adequate stowage bracket. LEGACY COMPONENT DESC: Location
Due 15 January 2004
Resolved 15 January 2004
Stability › Incline Test
Issued 4 December 2003 Resolved
Provide more adequate securing system for foam installation in steering compartment LEGACY COMPONENT DESC: Foam installation
Due 22 December 2003
Resolved 26 January 2004
Stability › Watertight Integrity › General
Issued 4 December 2003 Resolved
Non metallic pipe penetrations thru MTWB in engine room, provide penetrations I.A.W 46 CFR 182.40 (OLD T) LEGACY COMPONENT DESC: Bulkhead penetrations
Due 22 March 2004
Resolved 29 October 2004
Resolution: Cleared as directed
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 4 December 2003 Resolved
Provide flame failure switch, labeling and ensure cooking appliance and system comply with applicable ABYC standards prior to use of LPG cooking system. LEGACY COMPONENT DESC: LPG System Requirements
Action required: 705 - Other - as specified
Due 5 August 2004
Resolved 5 August 2004
Resolution: Completed proper repairs IAW attending MI.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 4 December 2003 Resolved
Provide adequate escape hatches prior allowing passengers below main deck
Action required: 705 - Other - as specified
Resolved 31 January 2004
Electrical › Lighting (emergency)
Issued 4 December 2003 Resolved
Provide adequate emergency lighting prior to allowing passengers below the main deck
Action required: 705 - Other - as specified
Resolved 31 January 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 4 December 2003 Resolved
Provide service report for fixed fire fighting system, servicing date is overdue.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2003
Documentation › Logs/Records
Issued 4 December 2003 Resolved
Ensure all safety position assigned crew members are included on company drug consortium LEGACY COMPONENT DESC: Drug Test Records
Due 5 January 2004
Resolved 15 February 2004
Stability › Incline Test
Issued 31 October 2003 Resolved
Calculations from July 2002 incline test revealed that vessel did not meet subdivision requirements. Vessel is restricted from commercial operations until subdivision requirements can be met and approved by the MSC. LEGACY COMPONENT DESC: Subdivision
Action required: 705 - Other - as specified
Due 19 December 2003
Resolved 20 December 2003
Resolution: Foam & lead ballast installed as required by MSC letter H1-0307106
Construction/Loadline › Structures
Issued 14 August 2003 Resolved
Make collision bulkhead water tight. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 21 August 2003
Resolved 30 September 2003
Engineering › Bilge Water Management System
Issued 14 August 2003 Resolved
Properly clamp electrical bilge pump in forpeak. LEGACY COMPONENT DESC: Pump
Due 21 August 2003
Resolved 30 September 2003
Electrical › Electrical Distribution System (service)
Issued 14 August 2003 Resolved
Properly wire electrical bilge pump in forpeak. LEGACY COMPONENT DESC: Wiring
Due 21 August 2003
Resolved 30 September 2003
Electrical › Electrical Distribution System (service)
Issued 14 August 2003 Resolved
Properly install electrical tape on wires for electrical bilge pump in the forpeak. LEGACY COMPONENT DESC: Wiring
Due 21 August 2003
Resolved 30 September 2003
Fire Fighting › Fire Main
Issued 14 August 2003 Resolved
Make permanent repairs to fire main piping in crew berthing. LEGACY COMPONENT DESC: Material
Due 21 August 2003
Resolved 30 September 2003
Engineering › Bilge Water Management System
Issued 14 August 2003 Resolved
Place proper handle on bilge shut off valve in crew berthing. LEGACY COMPONENT DESC: Valve
Due 21 August 2003
Resolved 30 September 2003
Electrical › Lighting (service)
Issued 14 August 2003 Resolved
Install light switch cover on light switch in crew berthing. LEGACY COMPONENT DESC: Switch
Due 21 August 2003
Resolved 30 September 2003
Engineering › Bilge Water Management System
Issued 14 August 2003 Resolved
Double clamp hoses for bilge system in crew hallway.
Due 21 August 2003
Resolved 30 September 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 14 August 2003 Resolved
Tighting packing on port shaft.
Due 21 August 2003
Resolved 30 October 2003
Engineering › Bilge Water Management System
Issued 14 August 2003 Resolved
Properly install electrical bilge pump in E/R
Due 21 August 2003
Resolved 30 September 2003
Electrical › Electrical Distribution System (service)
Issued 14 August 2003 Resolved
Properly label breakers on E/R distribution panel. LEGACY COMPONENT DESC: Distribution Panel Bus
Due 21 August 2003
Resolved 30 September 2003
Engineering
Issued 14 August 2003 Resolved
Make permanent repairs to hot water heater overflow hose.
Due 21 August 2003
Resolved 30 October 2003
Accommodation/Occupational Safety › Potable Water System
Issued 14 August 2003 Resolved
Secure potable water access covers.
Due 21 August 2003
Resolved 30 September 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 14 August 2003 Resolved
Make permanent repairs to fuel piping in E/R. LEGACY COMPONENT DESC: Piping
Due 21 August 2003
Resolved 30 September 2003
Fire Fighting › Fire Main
Issued 14 August 2003 Resolved
Make permanent repairs to fire main piping in Lazerett.
Due 21 August 2003
Resolved 30 September 2003
Fire Fighting › Fire Pumps
Issued 14 August 2003 Resolved
Make permanent repairs to electrical fire pump in E/R.
Due 21 August 2003
Resolved 30 September 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 14 August 2003 Resolved
Tighten clamp on port generator through hull fitting.
Due 21 August 2003
Resolved 30 October 2003
Communications › Alarms/Indicators
Issued 14 August 2003 Resolved
Install high level bilge alarm in E/R and prove proper operation. LEGACY COMPONENT DESC: Bilge Alarm
Due 15 August 2003
Resolved 30 September 2003
Pollution Prevention/Response › Prevention Equipment
Issued 14 August 2003 Resolved
Tighten clamps on sewage system in lazerett. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 21 August 2003
Resolved 30 September 2003
Electrical › Electrical Distribution System (service)
Issued 14 August 2003 Resolved
Properly secure cable in lazerett. LEGACY COMPONENT DESC: Wiring
Due 21 August 2003
Resolved 30 September 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 14 August 2003 Resolved
Properly install grounding strap on stbd fuel tank. LEGACY COMPONENT DESC: Tank
Due 21 August 2003
Resolved 30 September 2003
Engineering › Bilge Water Management System
Issued 14 August 2003 Resolved
Make permanent repairs to electrical bilge pump in the fwd passenger cabin. LEGACY COMPONENT DESC: Pump
Due 15 August 2003
Resolved 30 September 2003
Documentation › Certificates/Documents
Issued 14 August 2003 Resolved
Properly post COI LEGACY COMPONENT DESC: Certificate of Inspection
Due 21 August 2003
Resolved 30 September 2003
Documentation › Certificates/Documents
Issued 14 August 2003 Resolved
Properly post stability ltr. LEGACY COMPONENT DESC: Stability Letter
Due 21 August 2003
Resolved 30 October 2003
Operations/Management › Drug and Alcohol Testing
Issued 14 August 2003 Resolved
Provide proof of annual D&A program for all crew members.
Due 15 August 2003
Resolved 30 September 2003
Operations/Management › Drug and Alcohol Testing
Issued 14 August 2003 Resolved
Properly post D&A hotline numbers.
Due 21 August 2003
Resolved 30 September 2003
Operations/Management › Drug and Alcohol Testing
Issued 14 August 2003 Resolved
Provide a D&A contract to CG inspectors.
Due 21 August 2003
Resolved 30 October 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 14 August 2003 Resolved
Provide proof of annual servicing for fixed fire fighting system.
Due 30 November 2003
Resolved 30 October 2003
Resolution: 835 issued in error since fixed system is good until NOV 03. Cleared 10-30-03.
Operations/Management › Drills/Instruction
Issued 14 August 2003 Resolved
Provide current log book including fire and MOB drills.
Due 21 August 2003
Resolved 30 September 2003
Operations/Management › Passenger Operations
Issued 14 August 2003 Resolved
Develop a passenger count system.
Due 21 August 2003
Resolved 30 October 2003
Operations/Management › Drills/Instruction
Issued 14 August 2003 Resolved
Post emergency instructions.
Due 21 August 2003
Resolved 30 September 2003
Navigation › Collision/Grounding Avoidance
Issued 14 August 2003 Resolved
Provide updated charts and light list.
Due 21 August 2003
Resolved 30 October 2003
Navigation › Collision/Grounding Avoidance
Issued 14 August 2003 Resolved
Install proper navigation lights (UL 1104) LEGACY COMPONENT DESC: Navigation Lights
Due 21 August 2003
Resolved 30 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 14 August 2003 Resolved
Prove the deck rails can withstand the required weight of 200lbs. Damage to port handrail due to wake damage. Vessel owner has replacement wood prepared to install when vessel departs mooring. LEGACY COMPONENT DESC: Deck Rail
Due 28 August 2003
Resolved 4 December 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 14 August 2003 Resolved
Instal grab rail on galley stove. LEGACY COMPONENT DESC: Hand Grab
Due 28 August 2003
Resolved 30 September 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 14 August 2003 Resolved
Re-install sea rail on galley stove.
Due 21 August 2003
Resolved 30 September 2003
Construction/Loadline › Markings
Issued 14 August 2003 Resolved
Based on Stability letter, post the number of passenger allowed on upperdeck.
Due 21 August 2003
Resolved 30 October 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 14 August 2003 Resolved
Upon approval of overnight accomodation spaces, provide additional fire extinguishers as per Sub. part T.
Due 21 August 2003
Resolved 30 October 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 August 2003 Resolved
Provide CG approved or simular.
Due 21 August 2003
Resolved 30 October 2003
Lifesaving › Lifejacket/PFD (General)
Issued 14 August 2003 Resolved
Provide 01 additional life jacket.
Due 21 August 2003
Resolved 30 September 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 14 August 2003 Resolved
Provide proof of annual servicing of portable fire extinguishers. LEGACY COMPONENT DESC: Service
Due 15 August 2003
Resolved 30 October 2003
Fire Fighting › Fire Pumps
Issued 14 August 2003 Resolved
Install pressure gauge for fire pump. LEGACY COMPONENT DESC: Pressure
Due 21 August 2003
Resolved 30 October 2003
Communications › Alarms/Indicators
Issued 14 August 2003 Resolved
Label high level alarms on bridge. LEGACY COMPONENT DESC: Bilge Alarm
Due 21 August 2003
Resolved 30 September 2003
Fire Fighting › Ventilation Systems
Issued 14 August 2003 Resolved
Make E/R vent covers readily available to vent outlets. LEGACY COMPONENT DESC: Duct Hatches
Due 21 August 2003
Resolved 30 October 2003
Electrical › Electrical Distribution System (service)
Issued 21 October 2002 Resolved
Replace electircal cover in lazarette IWO Fixed CO2 Bottles LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 31 October 2002
Resolved 13 November 2002
Electrical › Electrical Distribution System (service)
Issued 21 October 2002 Resolved
Install cover to fuse fwd of Port Generator LEGACY COMPONENT DESC: Fuse
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 13 November 2002
Electrical › Electrical Distribution System (service)
Issued 21 October 2002 Resolved
Install covers to light switches and electrical recepticals in crew cabin. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 24 November 2002
Resolved 12 June 2003
Electrical › Electrical Distribution System (service)
Issued 21 October 2002 Resolved
Properly secure wire to house wtr pump in E/R LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 31 October 2002
Resolved 13 November 2002
Electrical › Electrical Distribution System (service)
Issued 21 October 2002 Resolved
Install cover to electrical receptical above potable wtr tank in E/R LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 31 October 2002
Resolved 13 November 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 21 October 2002 Resolved
Conspicuously mark location of fire extinguishers in crew cabin. LEGACY COMPONENT DESC: Marking
Condition: Design Flaw
Due 24 November 2002
Resolved 30 October 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 21 October 2002 Resolved
Mount portable fire extinguisher with proper bracket in way of crew cabin or passageway LEGACY COMPONENT DESC: Mounting Bracket
Condition: Design Flaw
Due 24 November 2002
Resolved 13 May 2003
Engineering › Bilge Water Management System
Issued 21 October 2002 Resolved
Install stop closure valve for submersible electircal bilge pump - stbd side lazarette LEGACY COMPONENT DESC: Valve
Condition: Design Flaw
Due 31 October 2002
Resolved 13 November 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 21 October 2002 Resolved
Permanently repair oil pan to Port Engine
Condition: Improper/Lack of Maintenance
Due 24 November 2002
Resolved 5 May 2003
Engineering › Bilge Water Management System
Issued 21 October 2002 Resolved
Post sign indicating location of Forepeak Bilge System shut off valve in Port Fwd State Room (Crew Cabin) LEGACY COMPONENT DESC: Valve
Condition: Design Flaw
Due 24 November 2002
Resolved 12 June 2003
Operations/Management › Drug and Alcohol Testing
Issued 21 October 2002 Resolved
Prove vessel meets requirements of chemical and alcohol found in 46CFR16 - Vsl is restricted from operation until requirement is met.
Due 24 November 2002
Resolved 30 October 2003
Lifesaving › Lifejacket/PFD (General)
Issued 21 October 2002 Resolved
Properly mark name of vsl on 12 adult lifejackets LEGACY COMPONENT DESC: Marking
Due 31 October 2002
Resolved 13 November 2002
Lifesaving › Lifebuoys
Issued 21 October 2002 Resolved
Prove proper operation of water light to ring life bouy - Vsl restricted to day light operation only until requirement is completed. LEGACY COMPONENT DESC: Self-igniting Lights
Due 31 October 2002
Resolved 13 November 2002
Lifesaving › Lifejacket/PFD (General)
Issued 21 October 2002 Resolved
Mark lifejacket storage container with number of lifejackets IWO bar on upper deck. LEGACY COMPONENT DESC: Storage
Due 24 November 2002
Resolved 12 June 2003
Lifesaving › Lifejacket/PFD (General)
Issued 21 October 2002 Resolved
Properly segregate adult/child lifejackets. LEGACY COMPONENT DESC: Storage
Due 24 November 2002
Resolved 12 June 2003
Fire Fighting
Issued 21 October 2002 Resolved
Provide servicing report for portable and fixed firefighting ext.
Due 31 October 2002
Resolved 13 November 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 21 October 2002 Resolved
Install searails to top of stovetop.
Due 24 November 2002
Resolved 5 May 2003
Engineering › Bilge Water Management System
Issued 21 October 2002 Resolved
Install high water float switch in forepeak and prove proper operation.
Due 24 November 2002
Resolved 30 September 2003
Engineering › Bilge Water Management System
Issued 21 October 2002 Resolved
Permanently mount electric submersible bilge pumps throughout vsl. LEGACY COMPONENT DESC: Pump
Due 24 November 2002
Resolved 13 May 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 21 October 2002 Resolved
Permanently mount portable fire extinguisher in Wheelhouse. LEGACY COMPONENT DESC: Mounting Bracket
Due 31 October 2002
Resolved 13 November 2002
Communications › Audible Communications
Issued 21 October 2002 Resolved
Install 300 mm ships bell. LEGACY COMPONENT DESC: Bell
Condition: Design Flaw
Due 24 November 2002
Resolved 30 October 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 15 July 2002 Resolved
Demonstrate to attending Marine Inspector that galley stove meets appropriate sections of 46 CFR 184 and 147. LEGACY COMPONENT DESC: LPG System Requirements
Due 26 October 2002
Resolved 24 October 2003
Lifesaving › Buoyant Apparatus
Issued 3 June 2002 Resolved
Provide non-corrosive clip for ring buoy waterlight. LEGACY COMPONENT DESC: Ring Buoy
Condition: Unknown
Due 17 June 2002
Resolved 15 July 2002
Resolution: Witnessed installation of corrosion resistant clip.
Construction/Loadline › Penetrations
Issued 3 June 2002 Resolved
Connect captive devices to exterior deck hatches. LEGACY COMPONENT DESC: Hatches
Condition: Unknown
Due 17 June 2002
Resolved 15 July 2002
Resolution: Witnessed installation of captive devices on hatches.
Engineering › Bilge Water Management System
Issued 3 June 2002 Resolved
Label bilge manifold in engine room. LEGACY COMPONENT DESC: Manifold
Condition: Unknown
Due 17 June 2002
Resolved 15 July 2002
Resolution: Witnessed labeling of bilge manifold.
Construction/Loadline
Issued 15 August 2001 Resolved
PROVIDE ADDITIONAL FASTENERS (LAG BOLTS) TO SECURE THE LOWER PORTSIDE LONGITUDNAL STIFFENERS IN THE FWD COMPARTMENT.
Condition: Unknown
Due 26 September 2001
Resolved 3 June 2002
Resolution: Fasteners installed as required.
Lifesaving
Issued 15 August 2001 Resolved
PROVIDE OPERATIONAL WATERLIGHT FOR RING BUOY.
Condition: Unknown
Due 26 September 2001
Resolved 3 June 2002
Resolution: Test sat.
Accommodation/Occupational Safety
Issued 15 August 2001 Resolved
PROVIDE VESSEL SPECIFIC EMERGENCY INSTRUCTIONS IAW 46 CFR 185.510/520
Condition: Unknown
Due 26 September 2001
Resolved 3 June 2002
Resolution: Emergency procedures posted for crew.
Accommodation/Occupational Safety
Issued 15 August 2001 Resolved
INSTALL PUBLIC ADRESS SYSTEM SPEAKERS FOR BELOW DECK ACCOMODATION SPACES.
Condition: Unknown
Due 26 September 2001
Resolved 3 June 2002
Resolution: Speakers installed; test sat.
Engineering
Issued 27 July 2001 Resolved
Repair/Replace leaking wet muffler for genset
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Lifesaving
Issued 27 July 2001 Resolved
Replace air tank with ASME "U" or "UM" stamped tank.
Condition: Unknown
Due 1 January 2002
Resolved 12 June 2003
Fire Fighting
Issued 27 July 2001 Resolved
Provide metal coaming around wood stove on main deck bar area to keep embers off carpet. Prior to burning anything in stove.
Condition: Unknown
Due 1 January 2002
Resolved 3 June 2002
Resolution: Safety glass border installed.
Lifesaving
Issued 27 July 2001 Resolved
Provide 36 Adult lifejackets. Vessel is restricted to no more than 23 totaladults onboard until additional lifejackets are obtained.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Prove proper operation of watertight deck hatches to satisfaction of attending Marine Inspector. Vessel is restricted to less than 1000 feet from shore until this requirement is cleared.
Condition: Unknown
Due 2 August 2001
Resolved 3 June 2002
Resolution: Watertight hatches installed.
Lifesaving
Issued 27 July 2001 Resolved
Provide a general alarm system prior to carrying more than 6 overnight passengers.
Condition: Unknown
Due 1 March 2002
Resolved 3 June 2002
Resolution: Alarm installed and tested sat.
Lifesaving
Issued 27 July 2001 Resolved
Provide 6 child sized life jackets. Vessel may not carry children until thechild sized life jackets are obtained.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Lifesaving
Issued 27 July 2001 Resolved
Provide lifejacket donning placards.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Fire Fighting
Issued 27 July 2001 Resolved
Install engine room fire detection system. Check engine room for fire and smoke every 15 minutes while underway until this requirement is cleared.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Lifesaving
Issued 27 July 2001 Resolved
Provide wire splint for First Aid Kit.
Condition: Unknown
Due 1 January 2002
Resolved 3 June 2002
Resolution: Splint provided.
Fire Fighting
Issued 27 July 2001 Resolved
Install approved fire alarms in each state room prior to carrying more than6 overnight passengers.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Fire Fighting
Issued 27 July 2001 Resolved
Provide manual means of closing engine room ventilation openings. Prior to carrying passengers.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Electrical
Issued 27 July 2001 Resolved
Provide emergency lighting below main deck in passenger and crew state rooms and heads prior to carrying more than 6 overnight passengers.
Condition: Unknown
Due 1 March 2002
Resolved 30 October 2003
Resolution: This was cleared by installing a rope at the entrance to the cabins with a sign stating no person below the main deck.
Engineering
Issued 27 July 2001 Resolved
Provide 30x30 mesh flame screens for fuel tank vent openings.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Engineering
Issued 27 July 2001 Resolved
Label emergency fuel cut-offs.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Provide collision bulkhead bilge pipe shut off valve. Remotely operated, or accessible from crew compartment.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Engineering
Issued 27 July 2001 Resolved
Repair leaking starboard MDE sea strainer prior to carrying passengers.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Provide second power bilge pump. Vessel may not carry more than 49 passengers until this requirement is cleared.
Condition: Unknown
Due 1 March 2002
Resolved 3 June 2002
Resolution: Existing fire pump plumbed into fixed bilge system as secondary pump.
Accommodation/Occupational Safety
Issued 27 July 2001 Resolved
Provide fixed public address system. Deckhands must carry portable radios until this requirement is cleared.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Navigation
Issued 27 July 2001 Resolved
Provide compass light. Vessel may not operate at night until this requirement is cleared.
Condition: Unknown
Due 2 August 2001
Resolved 15 July 2002
Resolution: Witnessed illumination of compass light.
Construction/Loadline
Issued 27 July 2001 Resolved
Provide wrenches for fore and aft main deck watertight deck hatches. Vesselis restricted to less than 1000 feet from shore until this requirement is cleared.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Make all main deck weather tight door coamings 6 inches high. Vessel is limited to operation on a Rivers Route until this requirement is cleared.
Condition: Unknown
Due 16 November 2001
Resolved 3 June 2002
Resolution: All door coamings installed.
Construction/Loadline
Issued 27 July 2001 Resolved
Provide draft marks or loading marks.
Condition: Unknown
Due 1 January 2002
Resolved 12 June 2003
Fire Fighting
Issued 27 July 2001 Resolved
MAKE VSL AVAILABLE FOR "AS-BUILT" VERIFICATION OF APPROVED FIXED CO2 FIRE FIGHTING SYSTEM. PLANS APPROVED BY NYCMI.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Forepeak: Restore port side longitudinal supports/frames as original, or provide calculations for adequacy of sideshell without these members.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Lifesaving
Issued 27 July 2001 Resolved
Provide CPR & First Aid training for half of the crew.
Condition: Unknown
Due 1 January 2002
Resolved 26 September 2002
Resolution: Not a CFR requirement -- recommended by NVIC. MBZ
Lifesaving
Issued 27 July 2001 Resolved
Increase Freeing Port size in aft corners from 2"x6" to 10"x 6"
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Engineering
Issued 27 July 2001 Resolved
Provide fuel tank vents.
Condition: Unknown
Due 13 August 2001
Resolved 30 July 2001
Accommodation/Occupational Safety
Issued 27 July 2001 Resolved
Provide 2nd means of escape from crew quarters and address passageway size.May not engage in trips of over 12 hours w/ alternate crew onboard until this requirement is cleared.
Condition: Unknown
Due 1 March 2002
Resolved 30 October 2003
Resolution: This was cleared by installing a rope at the entrance to the cabins with a sign stating no person below the main deck.
Documentation
Issued 27 July 2001 Resolved
Conduct CG approved & witnessed inclining experiment. After 1 March, 2002, vessel may not engage in commercial passenger operations until this requirement is completed.
Condition: Unknown
Due 28 June 2002
Resolved 15 July 2002
Resolution: Witnessed approved inclining experiment.
Construction/Loadline
Issued 27 July 2001 Resolved
Provide calculations to show that the steel keel is of adequate strength toreplace the original wooden keel.
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Stuff Port/Stbd cable ways in way of fwd bulkhead (engine room).
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Provide adequate through hull valves for bilge overboard in #2 compartment and shower sump overboard in #4 compartment (stbd side).
Condition: Unknown
Due 13 August 2001
Resolved 30 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Repair cleat on main deck stbd side in way of passenger gate.
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Documentation
Issued 27 July 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 August 2001
Resolved 5 November 2001
Fire Fighting
Issued 27 July 2001 Resolved
Repair leaking Fire Main in ER. Piping is leaking at brazed fitting
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Renew two (2) rotted planks stbd bow sheer strake.
Condition: Unknown
Due 1 January 2002
Resolved 3 June 2002
Resolution: Rotted planking replaced.
Accommodation/Occupational Safety
Issued 27 July 2001 Resolved
Bolt hand rail to bulwark in way of stbd passenger gate.
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Engineering
Issued 27 July 2001 Resolved
Cap openings on top of fuel tanks.
Condition: Unknown
Due 13 August 2001
Resolved 30 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Hard pipe installed bilge pump and show proper operation
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Properly mount bilge pump float switch in fwd E/R.
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Documentation
Issued 27 July 2001 Resolved
Submit plans and obtain Coast Guard approval for all alterations made to vessel since last certified for passenger service, including accommodation spaces,and new galley equipment.
Condition: Unknown
Due 1 January 2002
Resolved 26 September 2002
Resolution: Cleared this requirement & issued new one to demonstrate that galley stove meets appropriate sections of 46 CFR 184 and 147.
Electrical
Issued 27 July 2001 Resolved
Install anti-chafing material to wire support at centerline (engine room).
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Install double hose clamps at port power driven bilge pump (engine room).
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Install approved bilge hose for Rule bilge pumps and shower sumps throughout vessel.
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Cabin B - Prove proper operation of bilge overboard valve._x001C_ Cabin E - Provide overboard discharge valve for A/C discharge._x001C_ Cabine E - Prove proper operation of bilge overboard valve._x001C_ (all port side)
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Engineering
Issued 27 July 2001 Resolved
Provide flame impingement bowls for Racor filters in E/R.
Condition: Unknown
Due 13 August 2001
Resolved 30 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Demonstrate that other overboard fittings are more than 6" above the load waterline.
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Bore out worm holes in centerline plank in way of transom and properly fillin. Provide photos of repair if not inspected prior to floating.
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Electrical
Issued 27 July 2001 Resolved
Provide covers suitable for battery boxes.
Condition: Unknown
Due 13 August 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Provide gasket for forepeak deck hatch.
Condition: Unknown
Due 13 August 2001
Resolved 30 July 2001
Accommodation/Occupational Safety
Issued 27 July 2001 Resolved
No passengers allowed below main deck until a 2nd means of escape is provided from the passenger accoms spaces, and the size of the passageway is increased to 32 inches.
Condition: Unknown
Due 1 March 2002
Resolved 30 October 2003
Resolution: This issue was resolved by placing a rope at the entrance to the cabins with a sign stating no persons below the main deck.
Construction/Loadline
Issued 5 November 1997 Resolved
CROP AND RENEW SAMSON POST.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Construction/Loadline
Issued 5 November 1997 Resolved
SNUG DOWN ALL FASTENERS THROUGHOUT VESSEL.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Construction/Loadline
Issued 5 November 1997 Resolved
SUBMIT REPAIR PROPOSAL FOR LONGITUDINAL DECK SUPPORT BEAMS WHICH ARE CRACKED AND/OR WARPED IN VARIOUS PLACES IN #2 COMPT. NO PASENGERS FOR HIREUNTIL CLEARED.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Construction/Loadline
Issued 5 November 1997 Resolved
SCRAPE OFF ALL ROT/PAINT/ETC. OFF OF EVERYTHING WOOD THROUGHOUT INTERIOR OFVESSEL TO FACILITATE THOROUGH INSPECTION OF ROTTEN WOOD UNDER PAINT.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Construction/Loadline
Issued 5 November 1997 Resolved
CROP AND RENEW #1 TRANSVERSE DECK CROSSMEMBER IN E/R. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Construction/Loadline
Issued 5 November 1997 Resolved
CROP AND RENEW BOW SPRIT.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Construction/Loadline
Issued 5 November 1997 Resolved
SUBMIT REPAIR PROPOSAL FOR REPAIR OF ROTTED 4X6 LONGITUDINALS IN E/R AND LAZZARETTE. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Construction/Loadline
Issued 5 November 1997 Resolved
RENEW FASTENERS IN CRASH COMPT. STBD SIDE THRU 2X8 LONGITUDINAL STIFFENERS.NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Construction/Loadline
Issued 13 July 1995 Resolved
Make all below deck spaces watertight to the main deck.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Construction/Loadline
Issued 13 July 1995 Resolved
Remove entire length of skeg to access entire length keel for further examination.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Electrical
Issued 13 July 1995 Resolved
Provide blanks for all openings in engine room electrical panel.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Engineering
Issued 13 July 1995 Resolved
Weld port reach rod emergency fuel shutoff to port fuel tank supply valve.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Construction/Loadline
Issued 13 July 1995 Resolved
Make fwd main deck hatch cover watertight.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Construction/Loadline
Issued 13 July 1995 Resolved
Crop and renew main deck decking in way of fwd sampson post, to good wood.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, STARBOARD SIDE, FOURTH OUTBOARD OF KEEL AND SECOND FORWARD OF TRANSOM
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, STARBOARD SIDE, TENTH OUTBOARD OF KEEL AND IN WAY OF TRANSOM
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, STARBOARD SIDE, TWELTH OUTBOARD OF KEEL AND IN WAY OF TRANSOM
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Engineering
Issued 26 May 1995 Resolved
FIT UP BOTH PROPELLERS TO SHAFTS AND HAVE AVAILABLE FOR EXAM BY ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW GARBOARD PLANK, STARBOARD SIDE, FOURTH FORWARD OF TRANSOM
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
MAKE VESSEL AVAILABLE FOR DRY-DOCK.
Condition: Unknown
Due 13 June 1995
Resolved 13 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, STARBOARD SIDE, FIFTH OUTBOARD OF KEEL AND SECOND FORWARD OF TRANSOM
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REFASTEN PLANK, STARBOARD SIDE, FOURTH OUTBOARD OF KEEL AND THIRD FORWARD OF TRANSOM
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW BUTT BLOCK, STARBOARD SIDE, FIRST BUTT-BLOCK AFT OF STEM UNDER CHINE
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, STARBOARD SIDE, FOURTH OUTBOARD OF KEEL AND ADJACENT TO TRANSDUCER
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, STARBOARD SIDE, FOURTH OUTBOARD OF KEEL
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Unknown
Issued 26 May 1995 Resolved
PROVIDE LIST DESCRIBING MATERIALS USED IN WAY OF LENGTH, WIDTH AND THICKNESS FOR ALL PLANKS RENEWED
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
CROP AND RENEW ROOTED SECTIONS OF WEATHER DECK COVERING FOREPEAK.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
PLUG PENETRATION BETWEEN ENGINE ROOM AND LAZZARETTE ON PORT SIDE.
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
OPEN STARBOARD MSD TANK DISCHARGE VALVE FOR INTERNAL INSPECTION
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW ALL FRAME TO KEEL FASTENERS
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW ALL FASTENERS IN FRAMES IN WAY OF CHINE
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE ROTTED PLYWOOD "SISTERED" TO ENGINE ROOM FRAME (3) PORT
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Engineering
Issued 26 May 1995 Resolved
REPLACE LAGGING ON PORT MDE EXHAUST PIPING
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE CHINE AND KNEE BOLTS IN ENGINE ROOM FRAME (10) PORT
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE ALL WASTED FRAME AND CHINE BOLTS IN LAZZARETTE
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW ROTTED FRAME (11) STARBOARD IN ENGINE ROOM
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Electrical
Issued 26 May 1995 Resolved
RE-ATTACH CEILING LIGHTS IN COMPARTMENT NUMBER THREE
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Electrical
Issued 26 May 1995 Resolved
PROPERLY WIRE CEILING LIGHTS IN COMPARTMENT NUMBER THREE
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
PROVE PROPER OPERATION OF DECK DRAINAGE SYSTEM.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Engineering
Issued 26 May 1995 Resolved
REPLACE LAGGING ON PORT MDE EXHAUST SYSTEM.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Electrical
Issued 26 May 1995 Resolved
PROPERLY WIRE ELECTRICAL JUNCTION BOX AFT OF STARBOARD MDE
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE ALL ROTTED PLYWOOD SISTERED TO FRAMES (P7),(P8),(P9),(S8) AND (S9) P=PORT AND S=STARBOARD
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
INSTALL FASTENERS NEXT TO ALL EXISTING FASTENERS WHERE THE VERTICAL TRANSOMFRAMES MEET THE 6X6 INCH MEMBER AT THE JOINT OF TRANSOM AND HULL IN LAZZARETTE.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE ALL FRAME BOLTS ON VERTICAL FRAMES ON BOTH PORT AND STARBOARD SIDESOF LAZZARETTE UP TO THE EIGHTH PLANK ABOVE CHINE
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE ALL KNEE BOLTS ON PORT AND STARBOARD SIDES IN LAZZARETTE
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE ALL HORIZONTAL FRAME BOLTS IN LAZZARETTE INCLUDING THOSE LOCATED UNDER FUEL TANKS
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE HORIZONTAL KNEE BOLTS ON TRANSOM KNEES
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE DROP PINS ON BOTH PORT AND STARBOARD LONGITUDINALS (1) OUTBOARD OF CENTERLINE LONGITUDINAL
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE KNEE BOLTS ON FRAMES (10) AND (11) ON PORT SIDE OF ENGINE ROOM
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
INSTALL DOUBLED HOSE CLAMPS ON HOSE GOING THROUGH AFT BULKHEAD IN ENGINE ROOM.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Accommodation/Occupational Safety
Issued 26 May 1995 Resolved
PROVIDE PROOF OF PROPER VENTILATION OF MSD TANKS.
Condition: Unknown
Due 13 June 1995
Resolved 11 July 1995
Accommodation/Occupational Safety
Issued 26 May 1995 Resolved
REPLACE DECK AROUND SAMSON POST
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, STARBOARD SIDE, THIRD OUTBOARD OF KEEL WITH A PLANK OF THE PROPER SIZE (MIN= EIGHT FEET OR SIX FRAME SPACES)
Condition: Unknown
Due 3 July 1995
Resolved 13 July 1995
Accommodation/Occupational Safety
Issued 26 May 1995 Resolved
RENEW ALL FLEXIBLE COUPLINGS ON MSD TANKS.
Condition: Unknown
Due 13 June 1995
Resolved 11 July 1995
Fire Fighting
Issued 26 May 1995 Resolved
PROPERLY MOUNT AND WIRE FIRE PUMP.
Condition: Unknown
Due 3 July 1995
Resolved 11 July 1995
Engineering
Issued 26 May 1995 Resolved
REPAIR WATER LEAKS IN MDE EXHAUST SYSTEM IN ENGINE ROOM AND LAZARETTE.
Condition: Unknown
Due 3 July 1995
Resolved 11 July 1995
Engineering
Issued 26 May 1995 Resolved
REPLACE FLEXIBLE NON-METALLIC PIPING IN MDE FUEL SUPPLY AND RETURN LINES ATBOTH PORT AND STARBOARD FUEL TANKS.
Condition: Unknown
Due 13 June 1995
Resolved 11 July 1995
Engineering
Issued 26 May 1995 Resolved
INSTALL APPROVED TYPE FLEXIBLE COUPLINGS ON FUEL TANK FILL AND VENT LINES ON BOTH PORT AND STARBOARD FUEL TANKS.
Condition: Unknown
Due 13 June 1995
Resolved 11 July 1995
Accommodation/Occupational Safety
Issued 26 May 1995 Resolved
PROPERLY MOUNT AND WIRE SANITARY WATER PUMP.
Condition: Unknown
Due 3 July 1995
Resolved 11 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW GASKETS ON FORWARD AND AFT DECK HATCHES
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Fire Fighting
Issued 26 May 1995 Resolved
PROPERLY SECURE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Navigation
Issued 26 May 1995 Resolved
PROVIDE UP TO DATE CHARTS FOR AREA OF OPERATION.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Electrical
Issued 26 May 1995 Resolved
PROPERLY REINSTALL UNINSULATED STARTING SYSTEM WIRING ON BOTH MDE.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Lifesaving
Issued 26 May 1995 Resolved
PROPERLY MARK ALL PFDs WITH VESSEL NAME
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPAIR PENETRATION THROUGH HULL IN MAIN ENGINE ROOM, PORT SIDE UNDER DECK SEAL.
Condition: Unknown
Due 3 July 1995
Resolved 11 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPAIR LOOSE HULL FITTINGS AND SEIZED THRU-HULL VALVES IN MAIN ENGINE ROOM.
Condition: Unknown
Due 3 July 1995
Resolved 11 July 1995
Electrical
Issued 26 May 1995 Resolved
PROPERLY LABEL DISTRIBUTION PANEL IN MAIN ENGINE ROOM.
Condition: Unknown
Due 13 June 1995
Resolved 11 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
INSTALL PROPER PLUG IN UNUSED 3" SPOOL PIECE LOCATED ON PORT SIDE OF ENGINEROOM (AFT)
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Engineering
Issued 26 May 1995 Resolved
DOUBLE CLAMP ALL FLEXIBLE CONNECTIONS IN MDE (PORT AND STARBOARD) EXHAUST SYSTEM
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
SCARF OUT A MINIMUM OF (20) FEET OF KEEL COMMENCING AT FIRST SCARF JOINT AFT OF STEM PIECE.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
PROPERLY LABEL BILGE SYSTEM MANIFOLD
Condition: Unknown
Due 13 June 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
DROP SKEG AND MAKE AFT SECTION OF KEEL AVAILABLE FOR EXAM BY ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Navigation
Issued 26 May 1995 Resolved
RENEW PORT RUDDER POST BUSHING
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, PORT SIDE, NINTH OUTBOARD OF KEEL AND ADJACENT TO TRANSDUCER
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, PORT SIDE, SECOND OUTBOARD OF KEEL AND IN WAY OF KEEL COOLER
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, PORT SIDE, SEVENTH OUTBOARD OF KEEL AND ADJACENT TO TRANSDUCER
Condition: Unknown
Due 12 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, PORT SIDE, NINTH OUTBOARD OF KEEL AND AFT OF PLANK ADJACENT TOTRANSDUCER.
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE PLANK, PORT SIDE, NINTH OUTBOARD OF KEEL WITH A FULL WIDTH PLANK OFTHE PROPER LENGTH
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, PORT SIDE, THIRD OUTBOARD OF KEEL AND IN WAY OF TRANSOM.
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANK, PORT SIDE, SECOND OUTBOARD OF KEEL AND IN WAY OF TRANSOM
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
REPLACE PLANK, PORT SIDE, FOURTH OUTBOARD OF KEEL WITH A PLANK OF THE PROPER LENGTH
Condition: Unknown
Due 3 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 May 1995 Resolved
RENEW PLANKS (2), STARBOARD SIDE, FIFTH AND SIXTH OUTBOARD OF KEEL AND IN WAY OF TRANSOM
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Engineering
Issued 26 May 1995 Resolved
REPLACE STARBOARD STRUT BEARING AND BOTH PORT AND STARBOARD INNER BEARINGS
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Lifesaving
Issued 26 May 1994 Resolved
PROPERLY MARK ALL LIFERINGS WITH RETRO REFLECTIVE TAPE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Construction/Loadline
Issued 26 May 1994 Resolved
REFASTEN LONGITUDINAL SUPPORTS FOR RUDDER ASSEMBLY, AND PROVE PROPER REPAIRS WITH AN UNDERWAY CHECK.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Lifesaving
Issued 26 May 1994 Resolved
REPLACE FLOAT-FREE LINK FOR SINGLE 15 PERSON LIFEFLOAT WITH PROPER SIZE LINK.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Engineering
Issued 26 May 1994 Resolved
RENEW DECAYED SUPPORTS FOR ENGINE ROOM VENTILATION SHAFTS, PRIOR TO NEXT INSPECTION FOR CERTIFICATION.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Construction/Loadline
Issued 26 May 1994 Resolved
TREAT EARLY STAGE OF ROT IN FOREPEAK, AND IMPROVE VENTILATION TO SPACE.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Construction/Loadline
Issued 26 May 1994 Resolved
RENEW STBD DECK LONGITUDINAL IN MACHINERY SPACE IN WAY OF TRANSVERSE FRAMES2-6.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Construction/Loadline
Issued 28 April 1993 Resolved
MARK STERN OF VESSEL WITH VESSEL'S NAME AND HOMEPORT.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Accommodation/Occupational Safety
Issued 28 April 1993 Resolved
PROVIDE APPROVED USCG PLANS AND INSTALL ACCEPTABLE FRESHWATER SYSTEM INCLUDING TANK WITH ASSOCIATED PIPING AND PUMP (IF NECESSARY) TO WASH BASINS IN EACH HEAD.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Navigation
Issued 28 April 1993 Resolved
PROVIDE CURRENT COPY OF COAST PILOT.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Lifesaving
Issued 28 April 1993 Resolved
PROVIDE 2 RING BUOYS. COAST GUARD APPROVED.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Lifesaving
Issued 28 April 1993 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Accommodation/Occupational Safety
Issued 28 April 1993 Resolved
SEPARATE TOILETS FOR MEN AND WOMEN.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Lifesaving
Issued 28 April 1993 Resolved
PROVIDE LIFEJACKET DOWNING INSTRUCTIONS FOR EACH TYPE OF LIFEJACKET ON BOARD.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Lifesaving
Issued 28 April 1993 Resolved
PROVIDE WATERTIGHT CONTAINER FOR DISTRESS SIGNALS.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Construction/Loadline
Issued 28 April 1993 Resolved
REPAIR STEERING COMPARTMENT HATCH GASKET.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Construction/Loadline
Issued 28 April 1993 Resolved
PROPERLY REPAIR 3" WATER SEEPAGE STBD SIDE OF FOREPEAK IN WAY OFF COLLISIONBULKHEAD.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Navigation
Issued 28 April 1993 Resolved
PROVIDE UP TO DATE CHARTS FOR VESSEL'S OPERATING AREA.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Lifesaving
Issued 28 April 1993 Resolved
RE-STENCIL ALL LIFE PRESERVERS WITH VESSELS NAME AND BLACKOUT ALL OTHER NAMES.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Accommodation/Occupational Safety
Issued 28 April 1993 Resolved
PROVE PROPER OPERATION OF STBD TOILET FLUSHING DEVICE.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Construction/Loadline
Issued 29 May 1992 Resolved
INSTALL PROPER SCREENS IN THE FWD ACCOMODATION SPACE AND LAZARETTE BILGE SUCTIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Engineering
Issued 29 May 1992 Resolved
PROVIDE MISSING RAYCOR FUEL FILTER SHIELD ON STBD SIDE AFT BULKHEAD IN THE ENGINEROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Engineering
Issued 29 May 1992 Resolved
REPAIR LEAKS IN WATER COOLED EXHAUST PIPING FOR MDE. (SLIGHT DRIPPING)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Electrical
Issued 29 May 1992 Resolved
REMOVE ALL DEAD-END WIRES IN THE ENGINEROOM AND SECURE ALL LOOSE CABLE._x001C_
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Documentation
Issued 29 May 1992 Resolved
PROVIDE CURRENT COPY OF RULES OF ROAD BOOK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Fire Fighting
Issued 29 May 1992 Resolved
PROVIDE PRESSURE GAUGE FOR ELECTRIC FIRE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Accommodation/Occupational Safety
Issued 29 May 1992 Resolved
DEMONSTRATE PROPER OPERATION OF RUNNING WATER FOR SINKS.
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Construction/Loadline
Issued 29 May 1992 Resolved
REPAIR DELAMINATED DECK AREA STBD SIDE AFT MAIN DECK FOR WATERTIGHTNESS.
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Construction/Loadline
Issued 24 May 1991 Resolved
REFASTEN ENTIRE FIRST TRANSVERSE FRAME FORWARD OF TRANSOM IN LAZARETTE. (FRAME FASTENERS)
Condition: Unknown
Due 24 May 1991
Resolved 24 May 1991
Fire Fighting
Issued 24 May 1991 Resolved
PROVIDE GAGE FOR FIRE PUMP AND DEMONSTRATE THAT PUMP PROVIDES NOT LESS THAN60 PSI IN ACCORDANCE WITH 46 CFR 181.10-1(C).
Condition: Unknown
Due 24 May 1991
Resolved 24 May 1991
Construction/Loadline
Issued 24 May 1991 Resolved
CROP AND RENEW APPROX 2 X 5 FEET SECTION OF DECK WHERE ROTTED IN WAY OF MANHOLE TO LAZARETTE. REPAIRS SHOULD EXTEND TO DECK EDGE AND NEAREST SEAM INBOARD.
Condition: Unknown
Due 24 May 1991
Resolved 24 May 1991
Documentation
Issued 7 May 1990 Resolved
PROVIDE COPY OF CURRENT RADIO STATION LICENSE.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Accommodation/Occupational Safety
Issued 7 May 1990 Resolved
MAKE REPAIRS TO PROVIDE RUNNING WATER TO WASH BASINS IN BOTH HEADS.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Electrical
Issued 26 April 1989 Resolved
PROPERLY LABEL ELEC. PANEL IN E/R.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Construction/Loadline
Issued 26 April 1989 Resolved
PROVIDE WATERTIGHT SEAL OF WIRING PENETRATIONS IN COLLSION BULKHEAD.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Lifesaving
Issued 26 April 1989 Resolved
PROVIDE 5 ADDITIONAL APPROVED LIFE PRESERVERS. TOTAL PERSONS ALLOWED ON BOARD LIMITED TO 85 UNTIL REQUIREMENTS IS COMPLIED WITH.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Electrical
Issued 26 April 1989 Resolved
PROVIDE PROPER GLOBES FOR LIGHT FIXTURES IN E/R, BOTH SLEEPING COMPARTMENTSACCOMMODATION SPACE, WEATHER DECKS.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Lifesaving
Issued 26 April 1989 Resolved
PROVIDE PROPER PAINTER, FLOAT FREE LINK AND ATTACH WATER LIGHTS TO LIFE FLOATS.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Electrical
Issued 26 April 1989 Resolved
PROVIDE BLANKS FOR ELEC. PANELS IN E/R AND FOREWARD DECKHOUSE BULKHEAD.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Electrical
Issued 26 April 1989 Resolved
PROVIDE WATERTIGHT JUNCTION BOX FOR ELEC. CONNECTION OF SUBMERSIBLE BILGE PUMP IN FOREPEAK.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Lifesaving
Issued 26 April 1989 Resolved
PROPERLY MOUNT ONE RING LIFEBUOY AND WATERLIGHT ACCESSIBLE TO PILOTHOUSE.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Fire Fighting
Issued 26 April 1989 Resolved
PROPERLY MOUNT FIRE AXE IN PILOT HOUSE.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Construction/Loadline
Issued 26 April 1989 Resolved
CONDUCT U/W EXAM IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Documentation
Issued 11 July 1988 Resolved
PROVIDE AN INCLINING OR A DEAD WEIGHT SURVEY PROPOSAL TO ADDRESS THE PILOT HOUSE ADDITIONS MADE.
Condition: Unknown
Due 11 July 1988
Resolved 11 July 1988
Lifesaving
Issued 20 April 1988 Resolved
LOCK THE PADDLES IN THE LIFE FLOATS.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Navigation
Issued 20 April 1988 Resolved
POSITION MASTHEAD LIGHT FORWARD OF SIDELIGHTS TO CONFORM TO COLREGS.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Navigation
Issued 20 April 1988 Resolved
PROVE PROPER OPERATION OF SINGLE SIDE BAND RADIO. THE VESSEL MAY NOT OPERATE MORE THAN 20 MILES FROM SHORE UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Documentation
Issued 20 April 1988 Resolved
PROVIDE A POLLUTION PREVENTION PLACARD.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Navigation
Issued 20 April 1988 Resolved
REPACK THE PORT RUDDER POST.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Electrical
Issued 20 April 1988 Resolved
PROVIDE GLOBES & GUARDS FOR LIGHTS WHERE MISSING IN ENGINE ROOM.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Engineering
Issued 20 April 1988 Resolved
PROPERLY LABEL BILGE PIPING SYSTEM AT THE MANIFOLD IN THE ENGINE ROOM.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Construction/Loadline
Issued 6 April 1987 Resolved
FORWARD BUNK ROOM STARBORD SIDE - INSTALL A NON-RETURN CHECK VALVE FOR BILGE OVERBOARD (SECONDARY SYSTEM).
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Construction/Loadline
Issued 6 April 1987 Resolved
INSTALL RESTRAINING CHAINS ON THE HATCH COVERS FOR THE FORE AND AFT PEAK COMPARTMENTS.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Navigation
Issued 6 April 1987 Resolved
PROVE PROPER OPERATION OF PORT NAVIGATION LIGHT.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Engineering
Issued 6 April 1987 Resolved
INSTALL FLAME SHIELDS ON RACOR FUEL FILTERS (BOTH MAIN ENGINES AND GENERATOR).
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Fire Fighting
Issued 6 April 1987 Resolved
PROVIDE PROPER FIRE HOSE FOR STARBOARD SIDE FIRE STATION.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Accommodation/Occupational Safety
Issued 6 April 1987 Resolved
INSTALL VENT IN AFT PART OF THE ENGINE ROOM TO JUST ABOVE THE BILGE. A MINIMUM OF 20 SQUARE INCHES.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Electrical
Issued 6 April 1987 Resolved
INSTALL BLANK IN ELECTRICAL PANEL IN ENGINEROOM.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Documentation
Issued 6 June 1986 Resolved
OBTAIN A VALID STABILITY LETTER THAT ADDRESSES THE NEW WHEELHOUSE INSTALLA-TION.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Construction/Loadline
Issued 8 May 1985 Resolved
D/D VESSEL AND EFFECT PERMANENT REPAIRS IN WAY OF THE PLANKING OVER THE PORT AND STARBOARD PROPELLERS.
Condition: Unknown
Due 8 May 1985
Resolved 8 May 1985

Casualty record · 3

11 November 2004Routine · role: Involved in a Marine Casualty · activity 2246180
25 November 2008Routine · role: Involved in a Marine Casualty · activity 3370026
19 September 2009Routine · role: Involved in a Marine Casualty · activity 3601312
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.