Records from 1997 to 2008. Most recent: operational control imposed, 26 June 2008.
Inspection history · 13
26 June 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3248335
14 June 2008
MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3236609
13 May 2002
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1616506
25 August 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 471706
30 July 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 292458
27 July 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 292327
11 April 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 289042
24 March 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 288290
26 January 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 286323
2 June 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 278602
11 June 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 429575
11 June 1999
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1079681
9 August 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 406659
Lifesaving › Lifeboat › Markings
Issued 26 June 2008
Resolved
The Vessel's Free-fall Lifeboat does not have any of the required lifeboat markings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2008
Resolution: Rcvd satisfactory class report attesting to the proper marking and water replacement on vessel''s freefall lifeboat.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 26 June 2008
Resolved
The Vessel's Free-fall lifeboat does not have adequate water to accommodate the total number of persons the lifeboat is designed to carry.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2008
Resolution: Rcvd satisfactory class report attesting to the proper marking and water replacement on vessel''s freefall lifeboat.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 14 June 2008
Resolved
Vessel does not have updated CFRs with current applicable US regulations, vessel has only 1996 version. Obtain updated versions of 33 and 49 CFR prior to next US port.
Action required: 705 - Other - as specified
Resolved 19 June 2008
Resolution: Received receipt of invoice for CFR purchase. Updated CFRs on board, deficiency cleared.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 June 2008
No resolution recorded
Vessel does not have nor has proof that a non-tanker vessel response plan has been submitted for review to G-PCV-1. Vessel is to submit plan as per USCG guidelines to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Fire Fighting › Fire Hoses › Condition
Issued 14 June 2008
Resolved
Fire hose used for operational test of fire pumps was holed. Hose replaced while on board and functioned properly.
Action required: 705 - Other - as specified
Due 16 June 2008
Resolved 16 June 2008
Resolution: Cleared while on-board.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 14 June 2008
Resolved
CO2 cylinders were stowed directly on deck in CO2 room. Class is to verify and/or approve current arrangement prior to next US port.
Action required: 705 - Other - as specified
Resolved 19 June 2008
Resolution: Received class report approving current stowage arrangement of C02 cylinders.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 June 2008
Resolved
Ship found in non-compliance with approved Safety Management system. Master could not produce records of Fire/Abandon ship drills and maintenance of equipment. SHIP DETAINED
Action required: 705 - Other - as specified
Resolved 19 June 2008
Resolution: Audit carried out June 18th and 19th. Vessel received indepth training from owner''''s representatives while vessel in port. Bureau Veritas attended vessel and confirmed training and familiarity with SMS requirements.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 14 June 2008
Resolved
Vessel does not have current Safety Management Certificates or International Ship Security Certificates issued under new name "ONEGO TRACER". VSL to obtain interim SMC and ISSC prior to departure from the port.
Action required: 705 - Other - as specified
Resolved 19 June 2008
Resolution: Received report from Bureau Veritas verifying issuance of new ISSC and SMC reflecting name change.
Navigation
Issued 27 July 2001
Resolved
Echo depth sounding device inoperative. Failure to report prior to entry into the port of Fernandina. Issued a letter of warning to owner and vessel. Repair/Renew prior to 27AUG01 and provide class report to USCG.
Condition: Unknown
Due 27 August 2001
Resolved 31 July 2001
Navigation
Issued 27 July 2001
Resolved
Maneuvering fact sheet missing warning statement required by 33CFR164.35(g)7.
Condition: Unknown
Due 1 August 2001
Resolved 1 August 2001
Electrical
Issued 24 March 2001
Resolved
Number one generator went down during transit into the port of Fernandina. Repair number one generator and get a class report prior to 13 APR. 01.
Condition: Unknown
Due 13 April 2001
Resolved 11 April 2001
Engineering
Issued 26 January 2001
Resolved
No standard discharge connection on board. Fabricate or provide a standarddischarge connection prior to 25 Feb 01.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Fire Fighting
Issued 26 January 2001
Resolved
Emergency escape door in engine room does not automatically shut. Make escape door self closing prior to 25FEB.01.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 2 June 2000
Resolved
Prior to bunkering in the U.S. conduct bunker piping tests as required by 33 CFR 156.170.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Deck/Cargo
Issued 11 June 1999
Resolved
PROVIDE HOSE AND PIPE TEST RECORDS
Condition: Unknown
Due 8 July 2000
Resolved 8 July 2000
Engineering
Issued 9 August 1997
Resolved
Provide Hose & Pipe test records.
Condition: Unknown
Due 8 July 2000
Resolved 8 July 2000
Navigation
Issued 9 August 1997
Resolved
Provide handle for Emergency steering operation.
Condition: Unknown
Due 11 August 1999
Resolved 11 August 1999
Lifesaving
Issued 9 August 1997
Resolved
Provide monthly lifeboat inspection with required checklist._x001C_ SOLAS 74 III/19.7
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Lifesaving
Issued 9 August 1997
Resolved
Provide operating instructions for lauching lifeboat._x001C_ SOLAS 74 III/9
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Navigation
Issued 9 August 1997
Resolved
Provide U.S. Inland Navigation Rules._x001C_
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997