ADMIRAL I is a 1969 passenger vessel (uninspected). The Coast Guard has recorded 28 inspections since 1985, most recently in February 2006, along with 25 deficiencies.

Records from 1985 to 2006. Most recent: inspection, 22 February 2006.

Built
1969
Last inspected
22 February 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTD6784
Flag
UNITED STATES
—
Maury page id
psix-46231

Inspections, by type

…with no type recorded5
Years with a record 12 calendar years (1985–2006)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 28

22 February 2006 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2590104
26 January 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1116452
5 December 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1184656
18 January 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1176473
9 January 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 861448
8 March 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1164804
14 February 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 854079
1 November 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1138349
21 May 1993 Drydock Extension
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 836231
21 April 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146581
1 April 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1147819
5 March 1993 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1148274
21 January 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 943273
10 January 1992 COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1264032
21 October 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 939996
18 December 1989 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 944138
18 January 1989 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1208451
11 January 1989 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1206708
8 November 1988 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 896627
11 August 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1345558
20 April 1988 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1032540
21 January 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1024118
12 November 1987 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1331871
21 May 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1314766
21 May 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1314767
2 March 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1314763
5 November 1986 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1012041
8 November 1985 Credit Drydock · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1293321

Deficiency record · 25

Accommodation/Occupational Safety
Issued 9 January 1995 Resolved
Steam or otherwise clean the engines and engineroom to allow further examination for oil and exhaust leaks. (Engineroom covered in soot)
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Lifesaving
Issued 9 January 1995 Resolved
Post lifejacket placard.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Lifesaving
Issued 9 January 1995 Resolved
Replace hand lines on lifefloats also replace seapainter.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Fire Fighting
Issued 14 February 1994 Resolved
Repair or replace hand fire/bilge pump.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Documentation
Issued 14 February 1994 Resolved
Provide evidence of a drug testing program meeting the requirements of 46 CFR part 16.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Fire Fighting
Issued 5 March 1993 Resolved
PROVIDE APPROVED FIRE EXT. BRACKETS TWO LOCATIONS.
Condition: Unknown
Due 5 March 1993
Resolved 5 March 1993
Lifesaving
Issued 5 March 1993 Resolved
15 PFDs FOUND SERVICEABLE, ALL OTHERS TO BE REMOVED FROM VESSEL, UNTIL MADESERVICEABLE AND INSPECTED. TEMP COI IS FOR 15 PERSONS TOTAL.
Condition: Unknown
Due 5 March 1993
Resolved 5 March 1993
Engineering
Issued 5 March 1993 Resolved
P/S MAIN ENGINE MUFFLERS WASTED, LEAKING AND TO BE REPLACED _x001C_
Condition: Unknown
Due 5 March 1993
Resolved 5 March 1993
Engineering
Issued 5 March 1993 Resolved
RAW WATER HOSE TO PORT ENGINE AFTER SEA VALVE DETERIORATED REPLACE AS ORIGINAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 March 1993
Resolved 5 March 1993
Engineering
Issued 5 March 1993 Resolved
STBD KEEL COOLER ABANDED INPLACE BY OWNER TO BE PROPERLY BLANKED.
Condition: Unknown
Due 5 March 1993
Resolved 5 March 1993
Engineering
Issued 5 March 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 March 1993
Resolved 5 March 1993
Construction/Loadline
Issued 10 January 1992 Resolved
MAKE PERMENANT REPAIRS IN WAY OF SUBDIVISION BULKHEAD LOCATED BELOW MAIN DECK, DIVIDING MACH SPACES FROM CABIN. BULKHEAD WASTED THRU. OWNER EFFECTED TEMP REPAIRS.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Accommodation/Occupational Safety
Issued 8 November 1988 Resolved
REPAIR OR REPLACE THE FLUSHING SYSTEMS ON BOTH HEADS
Condition: Unknown
Due 8 November 1988
Resolved 8 November 1988
Accommodation/Occupational Safety
Issued 8 November 1988 Resolved
INCREASE RAIL HEIGHTS THROUGHOUT VESSEL TO 42 INCHES.
Condition: Unknown
Due 8 November 1988
Resolved 8 November 1988
Electrical
Issued 8 November 1988 Resolved
REPLACE STARBOARD SIDE TUPPERWARE JUNCTION BOX WITH A BOX THAT PROVIDES FORMECHANICAL AS WELL AS MOISTURE PROTECTION.
Condition: Unknown
Due 8 November 1988
Resolved 8 November 1988
Engineering
Issued 21 January 1988 Resolved
REPAIR OR REMOVE THE STBD MAIN ENGINE TACHOMETER.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Engineering
Issued 21 January 1988 Resolved
REMOVE THE EXCESSIVE ENGINE OIL FROM THE BILGES OF THE ENGINE ROOM.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Engineering
Issued 21 January 1988 Resolved
REMOVE OIL SOAKED INSULATION FROM THE STBD ENGINE EXHAUST RISERS, REPAIR THE EXHAUST LEAK AND REINSULATE THE RISERS.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Engineering
Issued 21 January 1988 Resolved
REPLACE THE JURY RIGGED CONNECTING ROD ON THE STBD MAIN ENGINE EMERGENCY SHUT OFF MECHANISM. DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Electrical
Issued 21 January 1988 Resolved
REMOVE THE IMPROPER WIRING TO THE 2 ENGINE ROOM ELECTRIC BILGE PUMPS AND PROPERLY REINSTALL. IF THIS WIRING IS FOR SOME OTHER PURPOSE PROPERLY SECURE IT OUT OF THE BILGES.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Engineering
Issued 21 January 1988 Resolved
REMOVE THE IMPROPERLY INSTALLED OIL SUMP PUMP AND ASSOCIATED WIRING AND HOSES. IF THIS UNIT IS DESIRED SUBMIT A PROPOSAL FOR PROPER INSTALLATION.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Construction/Loadline
Issued 21 January 1988 Resolved
REPLACE THE BROKEN / MISSING WINDOWS IN THE AFT DECKHOUSE. INSURE THAT THE WATERTIGHT INTEGRATY OF THE DECKHOUSE IS MAINTAINED.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Construction/Loadline
Issued 21 January 1988 Resolved
REINSTALL THE REMOVED CAPTIVE LANYARDS AND SECURING DEVICES FOR ALL OF THE MAIN DECK HATCHES.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Electrical
Issued 12 November 1987 Resolved
REPAIR THE AC GENERATOR AND DEMONSTRATE THE GENERATOR AND AC SYSTEM MEETS THE REQUIREMENTS OF 46 CFR 183.10
Condition: Unknown
Due 12 November 1987
Resolved 12 November 1987
Lifesaving
Issued 12 November 1987 Resolved
PLACE 4 ADDITIONAL ADULT TYPE I PFDS ONBOARD PRIOR TO CARRYING OVER 80 PERSONS.
Condition: Unknown
Due 12 November 1987
Resolved 12 November 1987

Ownership record