TORNADO

TORNADO is a 1969 passenger vessel (inspected). The Coast Guard has recorded 89 inspections since 1984, most recently in March 2026, along with 112 deficiencies and 1 casualty investigation in 2008.

Records from 1984 to 2026. Most recent: inspection, 30 March 2026.

Built
1969
Last inspected
30 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4954
Flag
UNITED STATES
303353000
Maury page id
psix-46235

Inspections, by type

…with no type recorded11
Years with a record 39 calendar years (1984–2026)
The 89 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.3 ft × 18.3 ft × 5.0 ft
Registered tonnagegross 37 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHERMODYNE INC · MARYSVILLE, WA, UNITED STATES · built 1969
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWESTPORT, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 26 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4954MMSI 303353000 · active · compulsorily equipped · granted 14 April 2017, expires 14 April 2027
WDC5959MMSI 303353000 · expired · compulsorily equipped · granted 11 June 2005, cancelled 15 August 2015
WTU4164MMSI not assigned · expired · compulsorily equipped · granted 11 July 1996, cancelled 2 December 2006
WCW5688MMSI not assigned · expired · voluntarily equipped · granted 9 May 1996, cancelled 15 July 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 89

30 March 2026 DAPI Audit · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8334549
3 December 2025 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8276865
27 March 2025 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8100973
9 April 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7892789
5 December 2023 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7831443
20 September 2023 In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7796051
17 January 2023 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7687011
9 January 2023 COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7617907
9 March 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7407521
18 November 2021 Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7351394
14 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7178785
28 May 2020 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6979323
29 October 2019 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6842231
25 September 2019 In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6813417
4 June 2019 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6716653
1 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6654313
9 January 2018 COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6331573
8 November 2017 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6302477
29 March 2017 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6111313
7 April 2016 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5848735
17 November 2015 Deficiency Check · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5764365
14 February 2012 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4246459
6 October 2010 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3870753
3 March 2010 Simplified Stability Test
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3686499
2 February 2010 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3666790
20 October 2008 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3352391
24 September 2008 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3326234
17 July 2008 Examination of Repairs · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3269689
13 July 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3289780
16 June 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3238843
5 February 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3142175
2 October 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3067364
1 March 2007 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2881940
7 February 2007 Deficiency Check · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2868364
5 October 2006 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2790191
1 July 2005 Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2377232
2 February 2005 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2284824
7 January 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2277322
5 January 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2224728
17 February 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2010007
6 January 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1980980
26 May 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1799321
11 March 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1755961
26 February 2003 Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1741060
7 February 2003 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1741492
9 January 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1725125
10 January 2002 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1476778
22 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076033
3 April 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1060019
1 February 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384674
18 January 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1463631
1 August 2000 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 821088
19 January 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1376033
5 January 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1369462
27 April 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1125896
26 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1124974
3 March 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806914
26 January 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1369009
12 January 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 809743
24 October 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 105488
21 January 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 777971
4 April 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1427357
8 January 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1096301
8 January 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1096302
13 December 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 658352
28 September 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 179231
28 September 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 212054
16 January 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1186512
26 April 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1172103
20 March 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 836989
26 January 1995 Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1143621
13 January 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 851058
19 February 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1146782
28 January 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1139450
19 January 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1139785
25 February 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 958082
23 December 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957596
13 March 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 916265
21 February 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 923622
7 February 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1234391
18 September 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1210327
26 January 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 899055
10 February 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1021438
13 January 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1324327
10 February 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1320812
2 September 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1029454
21 May 1986 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1297017
7 March 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 977771
30 October 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1283054

Deficiency record · 112

Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 17 November 2015 Resolved
The starboard side exhaust flange was found fractured and needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 17 November 2015
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 November 2015 Resolved
The 02 ball valves from the starboard side freshwater intake and the bait tank were found wasted and needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 17 November 2015
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 November 2015 Resolved
The starboard side exhaust lagging was found wasted away and needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 17 November 2015
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 24 September 2008 Resolved
Discovered 26 of 57 lifejackets had malfunctioning lights. Owner must replace 26 lifejacket lights. Passenger count reduced to 30 Adult and 1 Child until corrected. 46 CFR 180.75
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 October 2008
Resolved 20 October 2008
Engineering › Bilge Water Management System › Interface Detector
Issued 24 September 2008 Resolved
FWD bilge high level alarm switch is inoperable. Prove proper operation of high level alarm prior to carrying passengers. 46 CFR 182.530
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2008
Resolution: Renewed float switch.
Navigation › Piloting/Steering › Marine Charts
Issued 2 October 2007 Resolved
Provide current navigation chart 18003, prior to the carriage of passengers.
Due 2 November 2007
Resolved 9 October 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 October 2007 Resolved
Provide proof of current documentation, prior to the carriage of passengers.
Due 2 November 2007
Resolved 9 October 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 October 2007 Resolved
Renew starboard side ring buoy, or renew hand lines, prior to the carriage of passengers.
Due 2 November 2007
Resolved 9 October 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 October 2007 Resolved
Renew 5 adult lifejackets, passenger count is reduced to 46 until corrected.
Due 2 November 2007
Resolved 9 October 2007
Construction/Loadline › Hull › Hull Plating
Issued 7 February 2007 Resolved
Provide plans & complete repairs to FRP keel damged area approx 4 ft fwd of aft end of keel, prior to the carriage of passengers.
Due 7 March 2007
Resolved 1 March 2007
Resolution: Rcvd email confirm and digital photos of repairs.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 7 February 2007 Resolved
Renew stbd cutlass bearings due to excessive play and wear on the lower bearing surface, prior to the carriage of passengers. Port aft bearing is marginal and owner plans to renew both sides.
Due 7 March 2007
Resolved 1 March 2007
Resolution: Rcvd digphotos and report, both shafts pulled & trued, bearings renewed and props balanced.
Engineering › Steering Gear System › Rudder
Issued 7 February 2007 Resolved
Seal rudder post bolts as needed, prior to the carriage of passengers.
Due 7 March 2007
Resolved 1 March 2007
Resolution: Rcvd dig photos and report.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 5 October 2006 Resolved
Nine of the 51 required adult size and one of the 6 child size life jackets failed inspection due to large holes in Kapok bags and or failed retro tape. Total passenger count limited to not more than 41adults and 5 children until life jackets are renewed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2007
Resolved 7 February 2007
Resolution: renewed
Engineering › Bilge Water Management System › Hose
Issued 1 July 2005 Resolved
Prove compliance or renew both engine driven bilge pump discharge hoses with USCG approved. (Hoses are in good condition unable to determine if USCG approved).
Due 1 August 2005
Resolved 5 July 2005
Resolution: Renewed.
Stability › Unintentional Flooding › General
Issued 1 July 2005 Resolved
Blank off two 4 inch dia. vents on aft lazarette or install to proper height (only 8 inches). Vents are inserted thru deck and not mechanically sealed or fastened. This is a well deck vessel with 32 inch gunwhales, these vents wound contribute to flooding the aft laz with water on deck.
Due 1 August 2005
Resolved 5 July 2005
Resolution: Removed and deck has been sealed/glassed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 July 2005 Resolved
Post proper life jacket donning placard prior to the carriage of passengers. Current placard is not adequate.
Due 1 August 2005
Resolved 5 July 2005
Resolution: Posted.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 2 February 2005 Resolved
Renew both aft prop shaft bearings. Digital photos may be accepted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2005
Resolution: Witnessed installation of new cutlass bearings.
Engineering › Freshwater Generation System › Piping
Issued 2 February 2005 Resolved
Renew wasted connection in PVC bait tank overboard piping, stbd side.
Due 2 February 2005
Resolved 2 February 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 January 2005 Resolved
Prove operation of engine shut downs associated with engine room fixed fire extingushing system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2005
Resolved 7 January 2005
Resolution: New control box installed as original. System tested satisfactory.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 January 2005 Resolved
Provide onboard up to date Coast Pilot and Light List.
Due 5 February 2005
Resolved 2 February 2005
Resolution: Downloaded from the internet.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2005 Resolved
Properly splice wiring to sanitary water supply pump in way of screw type wire connectors.
Due 5 February 2005
Resolved 5 January 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2005 Resolved
Properly dead end exposed wiring in sewage tank compt centerline aft in overhead.
Due 5 February 2005
Resolved 2 February 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 5 January 2005 Resolved
Replace missing light bulb for fixture in sewage tank compt or disconnect fixture as discussed.
Due 5 February 2005
Resolved 2 February 2005
Resolution: Disconnected fixture.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 January 2005 Resolved
Make forward engine room blkhead watertight in way of penetration on centerline.
Due 5 February 2005
Resolved 2 February 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 January 2005 Resolved
Make aft engine room blkhead watertight in way of eight old bolt holes.
Due 5 February 2005
Resolved 2 February 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2005 Resolved
Properly splice wiring to fire/wash down pump in way of screw type connectors.
Due 5 February 2005
Resolved 2 February 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 January 2005 Resolved
Clean or renew lens on port running light.
Due 5 February 2005
Resolved 2 February 2005
Resolution: Installed a brand new light fixture and lens.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 January 2005 Resolved
Renew retro reflective material on one childs life jacket.
Due 5 February 2005
Resolved 2 February 2005
Resolution: Removed deficient lifejacket, there are extra children''s lifejackets on the vessel.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 5 January 2005 Resolved
Renew waterlight on one adult life jacket.
Due 5 January 2005
Resolved 5 January 2005
Resolution: Corrected on spot.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 January 2005 Resolved
Renew retro reflective material and labeling on ring buoy.
Due 5 January 2005
Resolved 5 January 2005
Resolution: Corrected on spot.
Engineering › Bilge Water Management System › Not Operational
Issued 5 January 2005 Resolved
Prove operation on engine room bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 January 2005
Resolved 5 January 2005
Resolution: Faulty wiring to float swith was repaired.
Lifesaving › Buoyant Apparatus › Painter
Issued 5 January 2005 Resolved
Properly attach life float arrangement in tandem.
Due 5 January 2005
Resolved 5 January 2005
Resolution: Corrected on spot.
Navigation › Piloting/Steering
Issued 6 January 2004 Resolved
Provided updated/current Coast Pilot. LEGACY COMPONENT DESC: US Coast Pilot
Due 6 February 2004
Resolved 17 February 2004
Resolution: Provided.
Lifesaving › Hand Flares
Issued 6 January 2004 Resolved
Provide proper stowage for flares in accordance with 46CFR185.614. LEGACY COMPONENT DESC: Storage
Due 6 February 2004
Resolved 17 February 2004
Resolution: Provided.
Engineering › Bilge Water Management System
Issued 6 January 2004 Resolved
Provide hose for "hand portable bilge pump" that will reach over the side of the vessel from all bilges. LEGACY COMPONENT DESC: Hose
Due 6 February 2004
Resolved 17 February 2004
Resolution: Provided.
Lifesaving › Buoyant Apparatus
Issued 6 January 2004 Resolved
Put name of vessel and number of persons capacity on the two aft lifefloats.
Due 6 February 2004
Resolved 17 February 2004
Resolution: Name and number of persons stenciled.
Lifesaving › Liferaft Equipment
Issued 6 January 2004 Resolved
Put name of vessel on all oars. LEGACY COMPONENT DESC: Paddle
Due 6 February 2004
Resolved 17 February 2004
Resolution: Name affixed.
Lifesaving
Issued 6 January 2004 Resolved
Secure the two oars being used as spacers for the aft lifefloats to its associated lifefloat.
Due 6 February 2004
Resolved 17 February 2004
Resolution: Secured.
Lifesaving › Lifebuoys
Issued 6 January 2004 Resolved
Replace all waterlight batteries annually. LEGACY COMPONENT DESC: Self-igniting Lights
Due 6 February 2004
Resolved 17 February 2004
Resolution: Replaced with new batteries.
Navigation › Piloting/Steering
Issued 6 January 2004 Resolved
Provide updated/current charts for navigated area. LEGACY COMPONENT DESC: Marine Charts
Due 6 February 2004
Resolved 17 February 2004
Resolution: Provided.
Lifesaving
Issued 6 January 2004 Resolved
Renew eyewash and burn spray for 1st aid kit.
Due 6 February 2004
Resolved 17 February 2004
Resolution: Renewed.
Engineering › Fuel Oil Service System
Issued 26 February 2003 Resolved
Repair as new, leak in stbd side fuel supply line, in way of fuel tank space. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 10 March 2003
Resolution: Replaced with new fuel supply line.
Engineering › Fuel Oil Service System
Issued 26 February 2003 Resolved
Reconnect fuel supply line ground strap, on port fuel tank line, in way of fuel tank space. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 10 March 2003
Resolution: Ground reconnected.
Personnel › Certificates/Documents/Licenses
Issued 9 January 2003 Resolved
Vessel may not be mastered by Domenic Davi until a new license is obtained/renewed. Domenic Davi may act as senior deckhand on the vessel until a new license is obtained. LEGACY COMPONENT DESC: License, Master
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 26 February 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 9 January 2003 Resolved
Show proof that 50% of crew has a valid CPR card. LEGACY COMPONENT DESC: CPR Cards
Due 28 February 2003
Resolved 26 February 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 9 January 2003 Resolved
Provide clamps on both ends of flexible fill pipe section of fuel tanks and provide conductor joining metallic sections of fill pipe IAW 46 CFR 182.445(g). LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 26 February 2003
Engineering › Bilge Water Management System
Issued 9 January 2003 Resolved
Provide applicable shutoff for lazarette bilge overboard thru hull fitting IAW 46 CFR 179.350(c). LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 26 February 2003
Stability › Watertight Integrity
Issued 9 January 2003 Resolved
Make all watertight bulkheads watertight in way of holes in subdivision bulkheads. LEGACY COMPONENT DESC: Subdivision bulkheads
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 26 February 2003
Stability › Watertight Integrity
Issued 9 January 2003 Resolved
Provide metallic shutoff valves for bilge piping piercing required watertight bulkheads IAW 46 CFR 182.720(d).
Action required: 705 - Other - as specified
Due 26 May 2003
Resolved 26 May 2003
Resolution: Metallic shutoff valves provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 January 2003 Resolved
Replace two condemned vessel lifejackets.
Due 9 January 2003
Resolved 9 January 2003
Lifesaving › Buoyant Apparatus
Issued 9 January 2003 Resolved
Provide separators for lifefloats that are stacked on top of each other. LEGACY COMPONENT DESC: separators
Due 9 January 2003
Resolved 9 January 2003
Lifesaving › Buoyant Apparatus
Issued 9 January 2003 Resolved
Put vessel name on all paddles for lifefloats. LEGACY COMPONENT DESC: Paddles
Due 9 January 2003
Resolved 9 January 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 January 2003 Resolved
Provide a 3-6 foot line with a corrosion resistant clip and attach it to lifebuoy.
Due 9 January 2003
Resolved 9 January 2003
Construction/Loadline › Structures
Issued 10 January 2002 Resolved
Replace broken/cracked windows on bridge and in passenger space (port/fwd). LEGACY COMPONENT DESC: Windows
Due 10 February 2002
Resolved 12 February 2002
Resolution: Owner provided pictures that the windows on the vessel had been replaced.
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 January 2002 Resolved
Replace one Type I PFD. PFD was badly damaged by black paint used to label vessels name. LEGACY COMPONENT DESC: Condition
Condition: Damaged By Earlier Event
Due 10 January 2002
Resolved 10 January 2002
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 10 January 2002 Resolved
Repair/replace six lights.
Condition: Improper/Lack of Maintenance
Due 10 January 2002
Resolved 10 January 2002
Resolution: Corrected on the spot.
Engineering
Issued 5 January 2000 Resolved
INSTALL GUARDS ON ROTATING MACHINERY I.W.O. MAIN ENGINES IN ACCORDANCE WITH46 CFR 177.35-15.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Navigation
Issued 5 January 2000 Resolved
PROVIDE CURRENT NAVIGATIONAL CHARTS APPROPRIATE FOR ROUTE I.A.W. 46 CFR 182.20-35.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Construction/Loadline
Issued 5 January 2000 Resolved
PROVE PROPER OPERATION OF BILGE PUMPING SYSTEM, PUMPING FROM FWD OF COLLISION BULKHEAD.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Construction/Loadline
Issued 5 January 2000 Resolved
INSTALL SCREW DOWN VALVE IN BILGE PIPE THAT TAKES SUCTION FROM BILGE FORWARD OF COLLISION BULKHEAD I.A.W. 46 CFR 182.25-5(d0.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Lifesaving
Issued 5 January 2000 Resolved
PROVIDE WATER TIGHT CONTAINER FOR PYROTECHNICS I.A.W. 46 CFR 180.35-10(b).
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Electrical
Issued 5 January 2000 Resolved
REMOVE DEAD ENDED/UNUSED ELECTRICAL WIRING FROM SPACE BELOW PILOT HOUSE ANDSPACE BELOW PASSENGER CABIN.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Electrical
Issued 5 January 2000 Resolved
PEOVIDE METAL SUPPORTS FOR LOOSE WIRING IN SPACE BELOW PASSENGER CABIN.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Navigation
Issued 5 January 2000 Resolved
REPAIR AND REINSTALL SINGLE SIDE BAND RADIO AND PROVE PROPER OPERATION OF SAME.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Construction/Loadline
Issued 26 January 1999 Resolved
Make aft engineroom bulkhead watertight.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Construction/Loadline
Issued 26 January 1999 Resolved
Install check valves in all bilge system branch lines.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Construction/Loadline
Issued 26 January 1999 Resolved
Replace missing piping to forepeak bilge suction.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Navigation
Issued 12 January 1999 Resolved
PROVIDE DOUBLE NUT BOLT ON STEERING GEAR ATTACHMENT TO FRAME.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Lifesaving
Issued 12 January 1999 Resolved
REPLACE EPIRB BATTERY PRIOR TO SAILING HIGH SEAS.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Documentation
Issued 21 January 1998 Resolved
PROVIDE UP TO DATE COPY OF RADIOTELEPHONY CERTIFICATE
Condition: Unknown
Due 21 January 1998
Resolved 21 January 1998
Accommodation/Occupational Safety
Issued 4 April 1997 Resolved
REPAIR RAILING IN SEVERAL SUPPORT AREAS (ON ALUMINUM SECTION).
Condition: Unknown
Due 4 May 1997
Resolved 7 May 1997
Construction/Loadline
Issued 4 April 1997 Resolved
MAKE PERMANENT MODIFICATIONS TO ENSURE WATERTIGHT ENGINEROOM HATCH.
Condition: Unknown
Due 4 May 1997
Resolved 7 May 1997
Accommodation/Occupational Safety
Issued 16 January 1996 Resolved
PLACE SCREEN OVER POTABLE WATER TANK VENT.
Condition: Unknown
Due 15 February 1996
Resolved 13 March 1996
Navigation
Issued 16 January 1996 Resolved
PROVE PROPER OPERATION OF SINGLE SIDE BAND RADIO. VESSEL IS RESTRICTED TO NOT MORE THAN 20 NAUTICAL MILES FROM A HARBOR OF SAFE REFUGE UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 15 February 1996
Resolved 13 March 1996
Lifesaving
Issued 16 January 1996 Resolved
PROVIDE SIX WATER LIGHTS FOR ADULT LIFE PRESERVERS. VESSEL IS RESTRICTED TO CARRYING 45 PERSONS ON LIMITED COASTWISE VOYAGES UNTIL REQUIREMENT IS MET.
Condition: Unknown
Due 15 February 1996
Resolved 13 March 1996
Accommodation/Occupational Safety
Issued 20 March 1995 Resolved
PROVIDE LOCK FOR BOTH MSD DISCHARGE VALVES.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Construction/Loadline
Issued 20 March 1995 Resolved
SEAL ACCESS COVER ON OVERHEAD OF FUEL TANK SPACE, STBD SIDE (SOFT PATCH).
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Navigation
Issued 20 March 1995 Resolved
PROVE PROPER OPERATION OF ANCHOR LIGHT. NO NIGHT TIME OR LOW VIS ANCHORING UNTIL REPAIRED.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Lifesaving
Issued 20 March 1995 Resolved
PROCURE JIM BUOY REPAIR KIT & PATCH 15 PERSON LIFE FLOAT.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Lifesaving
Issued 20 March 1995 Resolved
PROVIDE 4 ADULT AND ONE CHILD PFD LIGHTS.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Accommodation/Occupational Safety
Issued 20 March 1995 Resolved
DIESEL STOVE HAS BEEN REMOVED FROM VESSEL. SEAL OLD STOVE PIPE IN CABIN TOP.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Accommodation/Occupational Safety
Issued 20 March 1995 Resolved
PROVIDE SCOOPS FOR HEAD VENTS, PORT & STBD ON CABIN TOP. DUE TO BAD WX, RAIN WATER WAS ENTERING. SCOOPS MAY MAKE MORE WEATHER TIGHT.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Construction/Loadline
Issued 20 March 1995 Resolved
TREAT FURRING IN ENGINE ROOM OVERHEAD.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Accommodation/Occupational Safety
Issued 20 March 1995 Resolved
REPAIR WINDOW ON DOOR OF PILOT HOUSE, STBD SIDE. REPLACE WINDOWS PORT & STBD ON AFTER DECK OVERHANG.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Lifesaving
Issued 20 March 1995 Resolved
CONDUCT UNDERWAY TEST PLUS MAN OVERBOARD DRILL. ALL ELECTRONICS TESTED SAT.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Construction/Loadline
Issued 20 March 1995 Resolved
DEMONSTRATE PROPER OPERATION OF BILGE PUMP SYSTEM.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Engineering
Issued 26 January 1995 Resolved
SECURE FUEL (TANK) TUBING W/HANGERS AND CHAFING MATERIAL.
Condition: Unknown
Due 9 February 1995
Resolved 23 February 1995
Electrical
Issued 26 January 1995 Resolved
REPLACE WIRE NUTS W/PERMANENT CONNECTIONS (STEREO ON BRIDGE, PUMP AFT BULKHEAD IN MSD PIPING COMPT, AND ON LIGHT STBD SIDE, AFT OF FOREPEAK).
Condition: Unknown
Due 9 February 1995
Resolved 23 February 1995
Construction/Loadline
Issued 26 January 1995 Resolved
REPAIR WOOD DAMAGE AROUND PORT TRANSDUCER (DAMAGE DOES NOT AFFECT HULL AT THIS TIME). TO BE COMPLETED PRIOR TO CREDIT FOR DDX.
Condition: Unknown
Due 26 January 1995
Resolved 6 February 1995
Electrical
Issued 26 January 1995 Resolved
PROPERLY SUPPORT WIRING IN MIDBODY (MSD PIPING COMPT).
Condition: Unknown
Due 9 February 1995
Resolved 23 February 1995
Accommodation/Occupational Safety
Issued 26 January 1995 Resolved
REPAIR GRAY WATER INLET PIPE TO MSD STBD SIDE WHERE TAPE IS WRAPPED (AT ELBOW).
Condition: Unknown
Due 9 February 1995
Resolved 23 February 1995
Accommodation/Occupational Safety
Issued 26 January 1995 Resolved
REPLACE RUBBER HOSE ON PORT/STBD TOILET PIPING TO MSD HOLDING TANKS. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1995
Resolved 23 February 1995
Accommodation/Occupational Safety
Issued 26 January 1995 Resolved
PROVIDE ALLEN SCREWS AND SECURE THE BACKING BLOCKS FOR RAILING PORT SIDE AND AFT.
Condition: Unknown
Due 9 February 1995
Resolved 23 February 1995
Fire Fighting
Issued 26 January 1995 Resolved
SERVICE OR REMOVE FROM VESSEL ALL OUT-OF-DATE EXTINGUISHERS. PROVIDE COPY OF SERVICE REPORT VIA FAX. THIS ITEM TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 30 January 1995
Resolved 23 February 1995
Documentation
Issued 13 January 1994 Resolved
PROVIDE STABILITY LETTER FOR THE VESSEL. MOUNT ON BRIDGE UNDER GLASS OR OTHER SUITABLE COVER.
Condition: Unknown
Due 27 January 1994
Resolved 14 February 1994
Documentation
Issued 13 January 1994 Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 27 January 1994
Resolved 4 February 1994
Electrical
Issued 13 January 1994 Resolved
PROVIDE BLANKS FOR OPEN SPACES IN WHEEL HOUSE BREAKER PANEL.
Condition: Unknown
Due 27 January 1994
Resolved 4 February 1994
Lifesaving
Issued 28 January 1993 Resolved
REPAIR LOOSE HAND RAIL ON PORT MAIN DECK, AMID SHIPS
Condition: Unknown
Due 23 February 1993
Resolved 23 February 1993
Electrical
Issued 28 January 1993 Resolved
PROVIDE LIGHTS WITH PROPER LIGHT FIXTURES IN COMPARTMENT FORWARD OF ENGINE ROOM.
Condition: Unknown
Due 23 February 1993
Resolved 23 February 1993
Construction/Loadline
Issued 19 January 1993 Resolved
2"X1" HOLE IN ROUNDED TRANVERSE FRP MEMBER SUPPORTING BASE OF TRANSOM. REMAINS AS A RESULT OF REMOVAL OF OLD TRIM TAB ACTUATOR BRACKET.
Condition: Unknown
Due 5 March 1993
Resolved 29 January 1993
Navigation
Issued 23 December 1991 Resolved
SECURE LEAKING HYDRAULIC LINES UNDER BRIDGE CONSOLE.
Condition: Unknown
Due 23 December 1991
Resolved 23 December 1991
Electrical
Issued 23 December 1991 Resolved
PROVIDE BLANKS FOR ELECTRICAL OUTLETS ON BRIDGE CIRCUIT BREAKER PANEL.
Condition: Unknown
Due 23 December 1991
Resolved 23 December 1991
Construction/Loadline
Issued 21 February 1991 Resolved
INSTALL A LOCKING DEVICE FOR ENGINE ROOM HATCH COVERS.
Condition: Unknown
Due 21 February 1991
Resolved 21 February 1991
Fire Fighting
Issued 21 February 1991 Resolved
REPACK HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 21 February 1991
Resolved 21 February 1991
Electrical
Issued 21 February 1991 Resolved
REPLACE DEAD COVERS ON WHEELHOUSE FUSE BOX.
Condition: Unknown
Due 21 February 1991
Resolved 21 February 1991
Engineering
Issued 7 February 1990 Resolved
ENCLOSE REMOTE FUEL SHUT-OFF HANDLES SO AS TO BE OPERABLE FROM OUTSIDE THE SPACE.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Engineering
Issued 7 February 1990 Resolved
MOUNT WRENCH NEAR REMOTE FUEL SHUT-OFF ACCESS COVERS.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Engineering
Issued 7 February 1990 Resolved
PROVIDE GUARD FOR STARBOARD ENGINE ALTERNATOR DRIVE BELT.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Engineering
Issued 7 February 1990 Resolved
REPLACE STARBOARD FUEL TANK FLAME SCREEN.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Fire Fighting
Issued 7 February 1990 Resolved
PROVIDE SUCTION HOSE FOR HAND FIRE PUMP.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Unknown
Issued 21 May 1986 Resolved
CONDUCT U/W OPERATIONAL TEST OF ENGINES,STEERING GEAR,AND BRIDGE ELECTRONIC EQUIPMENT.
Condition: Unknown
Due 21 May 1986
Resolved 21 May 1986
Accommodation/Occupational Safety
Issued 21 May 1986 Resolved
PROVIDE MEANS OF LOCKING CLOSED MSD OVBD DSCH VALVES.
Condition: Unknown
Due 21 May 1986
Resolved 21 May 1986

Casualty record · 1

13 July 2008Routine · role: Involved in a Marine Casualty · activity 3289780
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.