Records from 1985 to 2025. Most recent: inspection, 11 December 2025.
Inspection history · 77
11 December 2025
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8282055
10 December 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8261173
6 May 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8096289
30 April 2025
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8124231
30 January 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7811368
19 December 2023
Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7811360
25 January 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7617520
21 December 2022
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7618767
25 March 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7418546
25 March 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7418717
23 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7402313
10 February 2022
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7411593
13 January 2022
Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7380221
10 February 2021
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7133364
11 February 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6906940
6 January 2020
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6875600
18 April 2019
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6632973
30 March 2018
Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6380530
24 January 2018
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6324415
24 February 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6073770
3 June 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5896629
1 June 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5896655
17 February 2016
DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5812336
4 January 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5790587
28 May 2014
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4872537
12 May 2014
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4841417
3 May 2012
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4289868
24 February 2012
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4239828
4 July 2011
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4068888
11 February 2011
Administrative Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3938461
8 March 2010
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3691864
28 January 2010
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3664614
6 March 2009
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3428468
22 December 2008
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3383861
17 December 2008
Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3381397
17 December 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3386674
12 March 2008
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3158429
4 March 2008
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3158451
21 December 2007
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3117174
24 April 2007
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2914720
24 January 2007
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2840293
5 December 2005
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2546257
3 March 2005
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2302814
6 February 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001691
16 December 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1965594
21 August 2003
In-Service Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1883089
3 December 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1713984
19 December 2001
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1485988
4 December 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366690
5 April 2001
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1062232
5 January 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1427763
30 December 1999
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1429291
25 March 1999
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 780470
19 January 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 163115
16 December 1998
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1415097
9 December 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368954
9 December 1997
COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1445291
13 December 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 664129
12 December 1996
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1413088
26 December 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1398376
19 December 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1448719
15 December 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 850842
3 February 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 854471
4 January 1994
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1160619
21 December 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 849292
27 September 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 227560
17 December 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 830916
17 December 1991
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1247544
6 February 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 919810
8 May 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1342200
17 November 1988
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 893308
24 August 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1039852
14 July 1988
Drydock Extension · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1035023
18 May 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1331737
24 April 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1004847
15 August 1985
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1293314
3 June 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 984382
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 11 December 2025
Resolved
During the examination all accessible parts of the vessel's underwater body shall be available for examination. MI observed cracked welds on structural members beneath the main engine on both port and starboard sides. Submit plans for repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 December 2025
Resolved 16 December 2025
Resolution: MI received proof of repairs. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2025
Resolved
All portable fire extinguishers installed on vessels shall be of an approved type. Extinguisher bracket in pilothouse were not the correct bracket.
Old T- 46CFR181.30-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Portable fire extinguisher in pilot house mounted to approved bracket.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 May 2025
Resolved
Penetrations and openings in watertight bulkheads must: Have means to make them watertight. MI found open penetrations in watertight bulkhead aft of fuel tank below saloon deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Penetrations in watertight bulkhead aft of the fuel tank below saloon deck sealed to make watertight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2025
Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. MI observed missing cover on battery installation in pilot house.
46 CFR 183.05-20(a)(Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Penetrations in watertight bulkhead aft of the fuel tank below saloon deck sealed to make watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. MI observed deterioration of lifelines on port and starboard life ring buoys.
(46 CFR 180.70(c)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Lifelines on port and starboard ring life buoys replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: The pump is permanently mounted. MI observed the electrical submersible pump in lazarette not properly secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Electrical submersible pump in lazarette secured with permanent mount.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to; Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed cut and exposed electrical cable in bilge space beneath saloon.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Electrical cable in bilge space beneath salon covered with plastic tubing to keep it from being exposed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 April 2025
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. MI observed no port and starboard guards near shafts in the engine-room that could pose hazards to crew while vessel is underway.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 13 May 2025
Resolution: Owner/operator installed guards over the port and starboard shafts.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2025
Resolved
Distribution panels and switchboards that are accessible from the rear must be constructed to prevent a person from accidentally contacting energized parts. MI observed the panel from the batteries to main engine switches exposed on the rear that could potentially harm crew in the engine-room while machinery is running.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 13 May 2025
Resolution: Owner/operator put a cover on the backside of the electrical panel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 April 2025
Resolved
A keel cooler installation used for engine cooling must be designed to prevent flooding. MI observed the inlet and outlet to the keel coolers that are no longer in-use improperly capped with plastic on ends of double clamped rubber hoses.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 13 May 2025
Resolution: Owner/operator recapped the keel cooler inlets and outlets with metal caps clamped to rubber hosing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2024
Resolved
All portable fire extinguishers installed on vessels shall be of an approved type. Extinguisher bracket on mess deck and engine room were not the coorect type.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 9 February 2024
Resolution: Vessel rep provided proof of required extinguisher bracket.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 January 2023
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following spaces: A machinery space bilge. Vessel's engine room bilge alarm did not produce visual indication.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 4 February 2023
Resolution: Received photo from operator of bilge alarm light functioning.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2022
Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway.
Vessel suffered LOP outside LA Harbor, due to clogged Port and Stbd fuel filters (with port changed a second time). 835 issued to document LOP and clogged fuel system to maintain USCG awareness if a trend continues onboard this vessel.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 March 2022
Resolved 25 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 March 2022
Resolved
A hatch exposed to the weather must be watertight. Replace lazarette and engine room deck hatch gasket's.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 24 March 2022
Resolution: MI witnessed repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hill in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Repair fuel leak found on starboard main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2022
Resolved 24 March 2022
Resolution: MI witnessed repair.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 February 2022
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter, Vessel did not have IBA stowed with in a way to float free.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2022
Resolved 10 February 2022
Resolution: Vessel properly installed hydrostatic release. Cleared 01 deficiency
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 February 2020
Resolved
Provisions shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected.
Engine room ventilation openings do not have effective closures. Ensure closures properly fit ventilation openings for starboard aft and port forward vent openings.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 February 2020
Resolution: Operator made proper repairs to engineroom ventilation covers. Test SAT.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 11 February 2020
Resolved
Each ship transporting more than six passengers for hire equipped with a radio telephone station must carry a FCC marine radio operator permit.
Master to obtain an FCC Marine Operators Permit.
47CFR80.159(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 7 October 2020
Resolution: Operator provided proof of valid FCC Operators Permit.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 February 2020
Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
The forward peak hatch was not attached to its chain. Secure chain to hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 February 2020
Resolution: Master replaced pin to secure the chain to the hatch.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 April 2019
Resolved
Vessel required to have EPIRB. Repalce EPIRB battery found to have expired on 02/19. Vesse; restricted to operation within three nautical miles from shore.
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2019
Resolved
Vessel name and hailing port are not visible from stern. Provide visible name and hailing port on the stern of the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 8 May 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2019
Resolved
Penetrations in a watertight bulkhead must be watertight. Make bulkhead between salon bilge space and engine room bilge space watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 8 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 April 2019
Resolved
A hatch exposed to weather must be watertight. Make both port and stbd engine compartment hatches watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 15 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 April 2019
Resolved
COI must be posted under transparent material, in a conspicuous location on the vessel. Post COI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 8 May 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2019
Resolved
Positive shutoff valve required at hull penetration. Replace wasted valve in lazarrette.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 8 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 April 2019
Resolved
Stability letter must be posted at the operating station. Post stability letter.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 8 May 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2019
Resolved
Distribution panel must be totally enclosed. Relocate distribution panel cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 15 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2019
Resolved
Replace fire extinguisher in salon that has been discharged.
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 April 2019
Resolved
Provide Inflatable liferaft with the hydrostatic release correctly installed. Painter was found to be incorrectly attached to hydrostatic release.
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2019
Resolved
Replace retroreflective material on all three ring life buoys. All retroreflective material was found to be wasted and uneffective.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 April 2019
Resolved
MIS report from drug consortium not onboard the vessel. Provide MIS report for 2018.
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 30 March 2018
Resolved
IBA painter line was tied incorrectly, IBA would not deploy if vessel sank. Vessel corrected prior to departure.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 30 March 2018
Resolution: Vessel corrected prior to end of inspection.
Construction/Loadline › Penetrations › Gasket
Issued 30 March 2018
Resolved
Engine room doors were missing gasket material, vessel corrected prior to end of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 30 March 2018
Resolution: Vessel corrected prior to end of inspection.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 February 2017
Resolved
Replace/repair retroreflective material on 11 (eleven) adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Retroreflective material was replaced on the spot.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 24 February 2017
Resolved
Replace hose clamp on aft salon bulkhead watertight fitting.
Condition: Improper/Lack of Maintenance
Due 24 February 2017
Resolved 24 February 2017
Resolution: Hose clamp replaced with new on the spot.
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 February 2017
Resolved
Ensure aft emergency fuel shut off valve functions properly.
Condition: Improper Installation
Due 10 March 2017
Resolved 12 April 2017
Resolution: Crew reconfigured reach rod assembly to ensure smooth operation of the aft emergency fuel shut off valve.
Engineering › Lubricating Oil Service System › Cooler
Issued 1 June 2016
Resolved
Vessel is restricted to using Port side engine only until the source of the oil in the exhaust from the Starboard engine can be found and repaired.
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 6 June 2016
Resolution: Operator replace gear cooler oil box.
Stability › Watertight Integrity › General
Issued 17 February 2016
Resolved
Each hatch exposed to the weather must be water tight. Make hatches on weather deck water tight and replace gaskets through out vessel.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 15 March 2016
Resolution: Hatches were tested and found to be water tight.
Engineering › Bilge Water Management System › Valve
Issued 17 February 2016
Resolved
Each bilge pipeline shall be fitted with a stop valve at the control point or manifold. Install stop/check valves in bilge system
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Check valves were installed at all suction points.
Engineering › Steering Gear System › Linkage
Issued 17 February 2016
Resolved
Repair jockey bar ball joint on steering gear
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Ball joint was renewed.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 17 February 2016
Resolved
Provide proper mounting brackets for all portable fire extinguishers on board vessel.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 15 March 2016
Resolution: Proper mounting brackets were installed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 February 2016
Resolved
Securely connect fuel shut off valve to handle at weatherdeck access.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 15 March 2016
Resolution: Handles were connected.
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 February 2016
Resolved
Indicate direction of operation on weatherdeck accessible fuel shut off.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 15 March 2016
Resolution: Direction of operation was marked.
Engineering › Diesel Engine (auxiliary) › Silencer (exhaust)
Issued 17 February 2016
Resolved
Provide proper lagging insulation on generator exhaust
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 15 March 2016
Resolution: Generator was properly lagged.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 May 2014
Resolved
Provide 4 additional life jackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2014
Resolved 12 May 2014
Resolution: 4 new life jackets were placed onboard, fixed on the spot.
Stability › Weathertight Integrity › General
Issued 12 May 2014
Resolved
Repair or replace gasket on lazzarette hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2014
Resolved 28 May 2014
Resolution: Replaced gasket.
Engineering › Bilge Water Management System › Interface Detector
Issued 12 May 2014
Resolved
Provide indicator for automatic bilge pump in lazzarette or make pump non-automatic.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2014
Resolved 28 May 2014
Resolution: Indicator provided.
Engineering › Sea-water System (primary cooling) › Valve
Issued 12 May 2014
Resolved
Repair or replace leaking valve in seachest overboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2014
Resolved 28 May 2014
Resolution: Valve replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 May 2014
Resolved
Remove dead end wiring from starboard head.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2014
Resolved 12 May 2014
Resolution: Fixed on the spot.
Engineering › Bilge Water Management System › Piping
Issued 3 May 2012
Resolved
Prove proper operation of the bilge suction from the forepeak space and replace checkvalve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2012
Resolved 4 May 2012
Resolution: Bilge piping system and checkvalve forward of the collision bulkhead operationally tested.
Lifesaving › Lifefloat › Lifeline
Issued 3 May 2012
Resolved
25 man lifefloat mounted on house of vessel found to be unserviceable due to frayed and worn lifelines. Lifelines appear to have succumbed to excessive UV damage, neglect and preventative maintenance. Passenger capacity to be reduced by 25 passenger until an equivalent lifefloat can be provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2012
Resolved 14 May 2012
Resolution: Replacement 22 man lifefloat verified as being properly installed, marked and stowed. The replacement lifefloat is now 22 person (3 less than the original unservicable 25 man lifefloat).
Fire Fighting › Semiportable CO2 Fire Extinguishers › Discharge Hose
Issued 3 May 2012
Resolved
The supply hose leading from the nitrogen supply tank to the storage charge tank was found cracked and unserviceable under emergency conditions. The unit had been previously serviced by Paines Wessex in January 2012. The B-V is not required by the COI unless the vessel is carrying hazardous materials.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2012
Resolved 14 May 2012
Resolution: New supply hose verified as being properly installed by vessel operator. Operator has chosen to keep the B-V stored on the dock for use by other vessels. The COI does not state the B-V has to be on-board unless underway with hazardous materials.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2012
Resolved
Aspirin in the first aid kit found expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2012
Resolved 3 May 2012
Resolution: Aspirin with valid expiration date provided by ship crew.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 May 2012
Resolved
Lifering with self igniting light stowed on the bow found without any vessel name stenciled.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 May 2012
Resolved 3 May 2012
Resolution: Proper marking sighted on the bow mounted lifebuoy.
Electrical › Lighting (service) › Lighting Fixture
Issued 3 May 2012
Resolved
The globe and lighting fixture over the power management panel were both found missing exposing an open socket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2012
Resolved 3 May 2012
Resolution: Crew provided a replacement lighting fixture and globe.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 3 May 2012
Resolved
Port engineshaft shaft seal packing leaking water. To be tightened and operationally tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2012
Resolved 4 May 2012
Resolution: Operational tests conducted on shaft seal and verified proper operation without excessive leaking.
Engineering › Steering Gear System › Rudder Bearing
Issued 3 May 2012
Resolved
Starboard rudder post packing collar securing bolts found loose and also one found broken which resulted in excessive vertical motion underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2012
Resolved 4 May 2012
Resolution: Starboard rudder post packing and operational testing confirmed that satisfactory repairs completed.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 15 February 2011
Resolved
Submit for approval plans regarding re-power/engine replacement installation IAW 46 CFR 176.700
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 14 March 2011
Construction/Loadline › Hull › Bottom Plating
Issued 11 February 2011
Resolved
Clean & treat excessive pitting in way of lazarette
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Stability › Watertight Integrity › General
Issued 11 February 2011
Resolved
Make all watertight bulkheads watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 March 2011
Resolved 14 March 2011
Stability › Watertight Integrity › General
Issued 11 February 2011
Resolved
Address missing welds on watertight bulkheads with temporary corrective measures
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2011
Resolved 14 March 2011
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 11 February 2011
Resolved
Install lagging on both main engine exhausts IAW 46 CFR 177.970
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 11 February 2011
Resolved
Install machinery guards over rotating machinery in way of engine room IAW 46 CFR 58.01-20.
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 February 2011
Resolved
Label and install retroreflective tape on all lifering buoys
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Engineering › Fuel Oil Service System › Piping
Issued 11 February 2011
Resolved
Reinstall fuel feed pipe mounting bracket in way of lazarette IAW 46 CFR 182.455(b)(3)
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Stability › Watertight Integrity › General
Issued 11 February 2011
Resolved
Seal all watertight bulkhead penetrations
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Electrical › Electrical Distribution System (service) › Cable
Issued 11 February 2011
Resolved
Mount electrical wiring in way of lazarette IAW 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Stability › Watertight Integrity › General
Issued 11 February 2011
Resolved
Cap or remove old throttle cable piping in way of engine room fwd watertight bulkhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Electrical › Electric Generation Source (service) › Generator Cable
Issued 11 February 2011
Resolved
Remove excessive wiring in way of generator
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Engineering › Fuel Oil Service System › Hose
Issued 11 February 2011
Resolved
Install generator flexible fuel hose IAW 46 CFR 182.730(e)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 February 2011
Resolved
Secure loose battery cells in way of engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Engineering › Bilge Water Management System › Manifold
Issued 11 February 2011
Resolved
Label bilge manifold in way of engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 11 February 2011
Resolved
Install blank in way of hole in breaker panel located in the engine room
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Engineering › Fuel Oil Service System › Filter
Issued 11 February 2011
Resolved
Mount both low pressure fuel filters properly in way of engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2011
Resolved 14 March 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 February 2011
Resolved
Complete a satisfactory Inspection for Certification by a USCG Marine Inspector and obtain a valid Certificate of Inspection prior to carrying cargo or passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2011
Resolved 14 March 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 March 2009
Resolved
Vessel overdue for annual inspection. Complete satisfactory annual inspection IAW 46 CFR 176.500(b) prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2009
Resolved 6 March 2009
Resolution: Annual COI exam complete.
Engineering › Fuel Oil Service System › Piping
Issued 6 March 2009
Resolved
Make repairs to LO & FO leaks in the engine room & salon bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 11 March 2009
Resolution: Checked fuel and lube oil fitting and found it dry. No leaks.
Construction/Loadline › Structures › Ventilators
Issued 6 March 2009
Resolved
Replace the vent to the head or provide a suitable material to make the house watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 11 March 2009
Resolution: Aluminum cover has been bolted down with sealer. Water tight.
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
Company policy insufficient as required by 46 CFR 16.401.
Due 11 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
Company currently does not receive result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210.
Due 11 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
Documentation not kept for entire employment period as required by 46 CFR 16.210.
Due 11 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Due 11 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Due 11 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 11 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
Employee Assistance Program (EAP) policy/statement not in place as required by 46 CFR 16.401.
Due 11 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
Company does not have a Substance Abuse Professional (SAP) as required by 46 CFR 16.401.
Due 11 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
MIS form not submitted by March 15 as required by 46 CFR 16.500.
Due 11 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
Copy of latest MIS form not available for review as required by 46 CFR 16.500.
Due 11 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008
Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Due 11 January 2009
Resolved 9 January 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 17 December 2008
Resolved
Demonstrate proper operation of the port main engine. Replace any/all fire damaged systems or equipment. Provide technicians report to determine the root cause to the fire in the port main engine turbo/exhaust.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2009
Resolved 31 December 2008
Resolution: Satisfactorily tested the port main engine and received tech report.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 March 2008
Resolved
You must undergo a satisfactory annual inspection prior to carrying passengers and to the satisfaction of an attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2008
Resolved 12 March 2008
Resolution: Annual inspection conducted on 3/12/08. COI endorsed.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 24 April 2007
Resolved
It has been determined that your vessel's arrangement is such that an unconscious person cannot be recovered from the water without additional equipment. Provide rescue boat or platform or other suitable arrangement IAW 46 CFR 180.210 to the satisfaction of an attending CG marine inspector. To be completed by 24 May 07.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 16 July 2007
Resolution: Company personnel fabricated a ladder and davit that could successfully be used to rescue a helpless person.
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 January 2007
Resolved
Provide proper labelling for remote shutoff IAW 46CFR185.608
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 24 January 2007
Resolution: Labelling corrected.
Stability › Watertight Integrity › General
Issued 24 January 2007
Resolved
Make watertight bulkhead stbd side of engine room IAW 46CFR179.320 (c).
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 24 January 2007
Resolution: Bulkhead watertight.
Lifesaving › Lifefloat › Markings
Issued 3 March 2005
Resolved
Properly label lifefloat and provide maintenance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 23 March 2005
Resolution: Corrected
Communications › Radio Communications › EPIRB
Issued 3 March 2005
Resolved
Provide proof of EPIRB registration
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 23 March 2005
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 March 2005
Resolved
Designate lifejacket storage and label properly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 23 March 2005
Resolution: Corrected
Lifesaving › Lifebuoys › Serviceable
Issued 3 March 2005
Resolved
Provide good and serviceable liferings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 23 March 2005
Resolution: Corrected
Engineering › Bilge Water Management System › Manifold
Issued 3 March 2005
Resolved
Label bilge manifold valve system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 23 March 2005
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2005
Resolved
Remove all unused and dead ended electrical circuits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 23 March 2005
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2005
Resolved
Install metal wire hangars in engineroom where necessary.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 23 March 2005
Resolution: Corrected
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 3 March 2005
Resolved
Clearly and ledgibly label aft fuel tank shutoff and direction of valve operation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 23 March 2005
Resolution: Corrected
Electrical › Electrical Distribution System (service)
Issued 9 February 2004
Resolved
Replace electrical covers in galley.
Condition: Unknown
Due 19 February 2004
Resolved 9 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 9 February 2004
Resolved
Replace protective cover for range exhaust fan in galley. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Due 19 February 2004
Resolved 9 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 9 February 2004
Resolved
Repair / replace first step in lounge.
Condition: Unknown
Due 19 February 2004
Resolved 9 February 2004
Engineering
Issued 9 February 2004
Resolved
Repair / replace starboard rudderstock from leaking.
Due 19 February 2004
Resolved 9 February 2004
Engineering › Bilge Water Management System
Issued 10 December 2002
Resolved
Provide shut off valve for electric bilge pump in stern section IAW 46CFR 182.530.
LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 20 December 2002
Resolved 21 February 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 December 2002
Resolved
Refill/ replace expired items in first aid kit.
Condition: Unknown
Due 20 December 2002
Resolved 21 February 2003
Lifesaving › Lifeboat Equipment
Issued 10 December 2002
Resolved
Replace broken white paddle from farward life raft.
Condition: Unknown
Due 20 December 2002
Resolved 21 February 2003
Lifesaving › Liferaft Equipment
Issued 10 December 2002
Resolved
Repaint vessel name on all life raft paddles. LEGACY COMPONENT DESC: Paddle
Condition: Improper/Lack of Maintenance
Due 20 December 2002
Resolved 21 February 2003
Engineering
Issued 5 January 2000
Resolved
LABEL THE AFT EMERGENCY FUEL CUT-OFF VALVE.
Condition: Unknown
Due 12 January 2000
Resolved 12 January 2000
Unknown
Issued 5 January 2000
Resolved
PROVIDE A WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 12 January 2000
Resolved 12 January 2000
Lifesaving
Issued 5 January 2000
Resolved
PROVIDE CG APPROVED FIRST AID KIT OR EQUIVALENT.
Condition: Unknown
Due 12 January 2000
Resolved 12 January 2000
Navigation
Issued 5 January 2000
Resolved
PROVIDE UPDATED CHARTS (18740 & 18749)
Condition: Unknown
Due 12 January 2000
Resolved 5 January 2000
Accommodation/Occupational Safety
Issued 9 December 1998
Resolved
Place the vessel's name on the following items: Emergency VHF placard, life float, ring buoy and all lifejackets.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Navigation
Issued 9 December 1998
Resolved
Provide vessel with updated charts.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Navigation
Issued 9 December 1998
Resolved
Provide deviation table for magnetic compass.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Lifesaving
Issued 9 December 1998
Resolved
Provide life float with weak link and retroflective tape.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Navigation
Issued 12 December 1996
Resolved
Provide 8 inch bell as required by Nav Rules.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Lifesaving
Issued 12 December 1996
Resolved
Provide a first aid kit with the contents as stated in 46CFR160.041._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Documentation
Issued 12 December 1996
Resolved
Certificate of documentation was expired on 30NOV96._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Engineering
Issued 4 January 1994
Resolved
INSTALL SAFETY GUARDS AROUND BOTH PROPELLER SHAFTS.
Condition: Unknown
Due 4 January 1994
Resolved 4 January 1994
Unknown
Issued 17 December 1991
Resolved
PROVIDE WASTE MANAGEMENT PLAN, INCLUDING RESPONSIBILITIES FOR COLLECTION AND DISPOSAL LOCATION ASHORE.
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Lifesaving
Issued 14 July 1988
Resolved
REPAIR LIGHT ON FWD. PORT SIDE RING BUOY.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Lifesaving
Issued 14 July 1988
Resolved
REPLACE ONE SET OF BA PADDLES.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Navigation
Issued 14 July 1988
Resolved
TEST RADAR AFTER GENERATOR IS BACK IN COMMISION.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Accommodation/Occupational Safety
Issued 14 July 1988
Resolved
REPLACE BROKEN WINDOW IN REAR OF PILOT HOUSE.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Engineering
Issued 14 July 1988
Resolved
INSTALL VALVES OR HARD PIPE THE KEEL COOLERS.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Construction/Loadline
Issued 14 July 1988
Resolved
INSTALL GASKET ON FWD. HATCH.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Electrical
Issued 14 July 1988
Resolved
REPAIR GEWNERATOR OIL GAUGE.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Electrical
Issued 14 July 1988
Resolved
TEST RUN GENERATOR WHEN NEW VOLTAGE REGULATOR IS INSTALLED.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Electrical
Issued 14 July 1988
Resolved
LINE MAIN ENGINE BATTERY BOX.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Engineering
Issued 18 May 1987
Resolved
INSTALL AN ALARM IN THE EXHAUST COOLING WATER SYSTEM THAT IS AUDIBLE ON THE BRIDGE.
Condition: Unknown
Due 18 May 1987
Resolved 18 May 1987
Engineering
Issued 18 May 1987
Resolved
CLEAN ENGINEROOM.
Condition: Unknown
Due 18 May 1987
Resolved 18 May 1987
Engineering
Issued 18 May 1987
Resolved
REPAIR STBD. ENGINE TACH. ON CONSOLE.
Condition: Unknown
Due 18 May 1987
Resolved 18 May 1987
Documentation
Issued 3 June 1985
Resolved
OBTAIN A VALID FCC STATION LICENSE.
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Engineering
Issued 3 June 1985
Resolved
REPAIR EXHAUST COOLING LEAK ON PORT ENGINE OUTBOARD EXHAUST LINE IN ENGINE ROOM.
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Lifesaving
Issued 3 June 1985
Resolved
PROPERLY LABEL LIFEJACKET STOWAGE LOCKERS.
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Navigation
Issued 3 June 1985
Resolved
REPOSITION STERN LIGHT AS FAR AFT AS POSSIBLE.
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985