Records from 2008 to 2025. Most recent: inspection, 11 December 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 24
11 December 2025
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8282055
10 December 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8261173
6 May 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8096289
30 April 2025
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8124231
30 January 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7811368
19 December 2023
Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7811360
25 January 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7617520
21 December 2022
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7618767
25 March 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7418546
25 March 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7418717
23 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7402313
10 February 2022
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7411593
13 January 2022
Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7380221
10 February 2021
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7133364
11 February 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6906940
6 January 2020
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6875600
18 April 2019
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6632973
30 March 2018
Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6380530
24 January 2018
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6324415
24 February 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6073770
3 June 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5896629
1 June 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5896655
17 February 2016
DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5812336
4 January 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5790587
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 11 December 2025
Resolved
During the examination all accessible parts of the vessel's underwater body shall be available for examination. MI observed cracked welds on structural members beneath the main engine on both port and starboard sides. Submit plans for repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 December 2025
Resolved 16 December 2025
Resolution: MI received proof of repairs. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2025
Resolved
All portable fire extinguishers installed on vessels shall be of an approved type. Extinguisher bracket in pilothouse were not the correct bracket.
Old T- 46CFR181.30-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Portable fire extinguisher in pilot house mounted to approved bracket.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 May 2025
Resolved
Penetrations and openings in watertight bulkheads must: Have means to make them watertight. MI found open penetrations in watertight bulkhead aft of fuel tank below saloon deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Penetrations in watertight bulkhead aft of the fuel tank below saloon deck sealed to make watertight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2025
Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. MI observed missing cover on battery installation in pilot house.
46 CFR 183.05-20(a)(Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Penetrations in watertight bulkhead aft of the fuel tank below saloon deck sealed to make watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. MI observed deterioration of lifelines on port and starboard life ring buoys.
(46 CFR 180.70(c)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Lifelines on port and starboard ring life buoys replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: The pump is permanently mounted. MI observed the electrical submersible pump in lazarette not properly secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Electrical submersible pump in lazarette secured with permanent mount.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to; Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed cut and exposed electrical cable in bilge space beneath saloon.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Electrical cable in bilge space beneath salon covered with plastic tubing to keep it from being exposed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 April 2025
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. MI observed no port and starboard guards near shafts in the engine-room that could pose hazards to crew while vessel is underway.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 13 May 2025
Resolution: Owner/operator installed guards over the port and starboard shafts.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2025
Resolved
Distribution panels and switchboards that are accessible from the rear must be constructed to prevent a person from accidentally contacting energized parts. MI observed the panel from the batteries to main engine switches exposed on the rear that could potentially harm crew in the engine-room while machinery is running.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 13 May 2025
Resolution: Owner/operator put a cover on the backside of the electrical panel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 April 2025
Resolved
A keel cooler installation used for engine cooling must be designed to prevent flooding. MI observed the inlet and outlet to the keel coolers that are no longer in-use improperly capped with plastic on ends of double clamped rubber hoses.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 13 May 2025
Resolution: Owner/operator recapped the keel cooler inlets and outlets with metal caps clamped to rubber hosing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2024
Resolved
All portable fire extinguishers installed on vessels shall be of an approved type. Extinguisher bracket on mess deck and engine room were not the coorect type.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 9 February 2024
Resolution: Vessel rep provided proof of required extinguisher bracket.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 January 2023
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following spaces: A machinery space bilge. Vessel's engine room bilge alarm did not produce visual indication.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 4 February 2023
Resolution: Received photo from operator of bilge alarm light functioning.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2022
Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway.
Vessel suffered LOP outside LA Harbor, due to clogged Port and Stbd fuel filters (with port changed a second time). 835 issued to document LOP and clogged fuel system to maintain USCG awareness if a trend continues onboard this vessel.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 March 2022
Resolved 25 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 March 2022
Resolved
A hatch exposed to the weather must be watertight. Replace lazarette and engine room deck hatch gasket's.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 24 March 2022
Resolution: MI witnessed repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hill in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Repair fuel leak found on starboard main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2022
Resolved 24 March 2022
Resolution: MI witnessed repair.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 February 2022
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter, Vessel did not have IBA stowed with in a way to float free.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2022
Resolved 10 February 2022
Resolution: Vessel properly installed hydrostatic release. Cleared 01 deficiency
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 February 2020
Resolved
Provisions shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected.
Engine room ventilation openings do not have effective closures. Ensure closures properly fit ventilation openings for starboard aft and port forward vent openings.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 February 2020
Resolution: Operator made proper repairs to engineroom ventilation covers. Test SAT.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 11 February 2020
Resolved
Each ship transporting more than six passengers for hire equipped with a radio telephone station must carry a FCC marine radio operator permit.
Master to obtain an FCC Marine Operators Permit.
47CFR80.159(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 7 October 2020
Resolution: Operator provided proof of valid FCC Operators Permit.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 February 2020
Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
The forward peak hatch was not attached to its chain. Secure chain to hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 February 2020
Resolution: Master replaced pin to secure the chain to the hatch.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 April 2019
Resolved
Vessel required to have EPIRB. Repalce EPIRB battery found to have expired on 02/19. Vesse; restricted to operation within three nautical miles from shore.
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2019
Resolved
Vessel name and hailing port are not visible from stern. Provide visible name and hailing port on the stern of the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 8 May 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2019
Resolved
Penetrations in a watertight bulkhead must be watertight. Make bulkhead between salon bilge space and engine room bilge space watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 8 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 April 2019
Resolved
A hatch exposed to weather must be watertight. Make both port and stbd engine compartment hatches watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 15 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 April 2019
Resolved
COI must be posted under transparent material, in a conspicuous location on the vessel. Post COI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 8 May 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2019
Resolved
Positive shutoff valve required at hull penetration. Replace wasted valve in lazarrette.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 8 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 April 2019
Resolved
Stability letter must be posted at the operating station. Post stability letter.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 8 May 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2019
Resolved
Distribution panel must be totally enclosed. Relocate distribution panel cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 15 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2019
Resolved
Replace fire extinguisher in salon that has been discharged.
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 April 2019
Resolved
Provide Inflatable liferaft with the hydrostatic release correctly installed. Painter was found to be incorrectly attached to hydrostatic release.
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2019
Resolved
Replace retroreflective material on all three ring life buoys. All retroreflective material was found to be wasted and uneffective.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 April 2019
Resolved
MIS report from drug consortium not onboard the vessel. Provide MIS report for 2018.
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 30 March 2018
Resolved
IBA painter line was tied incorrectly, IBA would not deploy if vessel sank. Vessel corrected prior to departure.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 30 March 2018
Resolution: Vessel corrected prior to end of inspection.
Construction/Loadline › Penetrations › Gasket
Issued 30 March 2018
Resolved
Engine room doors were missing gasket material, vessel corrected prior to end of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 30 March 2018
Resolution: Vessel corrected prior to end of inspection.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 February 2017
Resolved
Replace/repair retroreflective material on 11 (eleven) adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Retroreflective material was replaced on the spot.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 24 February 2017
Resolved
Replace hose clamp on aft salon bulkhead watertight fitting.
Condition: Improper/Lack of Maintenance
Due 24 February 2017
Resolved 24 February 2017
Resolution: Hose clamp replaced with new on the spot.
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 February 2017
Resolved
Ensure aft emergency fuel shut off valve functions properly.
Condition: Improper Installation
Due 10 March 2017
Resolved 12 April 2017
Resolution: Crew reconfigured reach rod assembly to ensure smooth operation of the aft emergency fuel shut off valve.
Engineering › Lubricating Oil Service System › Cooler
Issued 1 June 2016
Resolved
Vessel is restricted to using Port side engine only until the source of the oil in the exhaust from the Starboard engine can be found and repaired.
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 6 June 2016
Resolution: Operator replace gear cooler oil box.
Stability › Watertight Integrity › General
Issued 17 February 2016
Resolved
Each hatch exposed to the weather must be water tight. Make hatches on weather deck water tight and replace gaskets through out vessel.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 15 March 2016
Resolution: Hatches were tested and found to be water tight.
Engineering › Bilge Water Management System › Valve
Issued 17 February 2016
Resolved
Each bilge pipeline shall be fitted with a stop valve at the control point or manifold. Install stop/check valves in bilge system
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Check valves were installed at all suction points.
Engineering › Steering Gear System › Linkage
Issued 17 February 2016
Resolved
Repair jockey bar ball joint on steering gear
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Ball joint was renewed.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 17 February 2016
Resolved
Provide proper mounting brackets for all portable fire extinguishers on board vessel.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 15 March 2016
Resolution: Proper mounting brackets were installed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 February 2016
Resolved
Securely connect fuel shut off valve to handle at weatherdeck access.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 15 March 2016
Resolution: Handles were connected.
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 February 2016
Resolved
Indicate direction of operation on weatherdeck accessible fuel shut off.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 15 March 2016
Resolution: Direction of operation was marked.
Engineering › Diesel Engine (auxiliary) › Silencer (exhaust)
Issued 17 February 2016
Resolved
Provide proper lagging insulation on generator exhaust
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 15 March 2016
Resolution: Generator was properly lagged.