Records from 1997 to 2006. Most recent: inspection, 8 June 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
8 June 2006
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2673722
28 April 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2345845
3 May 2004
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2057924
6 May 2003
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1917534
9 October 2002
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1729389
1 July 2002
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1645230
23 August 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1437943
18 July 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1418937
18 May 2001
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1384768
30 May 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1391321
13 May 1999
Hull Examination · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1045721
19 May 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126647
6 March 1998
Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 784463
23 May 1997
Hull Examination · Initial Certification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 782556
Engineering › Bilge Water Management System
Issued 3 May 2004
Resolved
Prove proper operation of port aft bilge sensor.
Action required: 705 - Other - as specified
Due 4 May 2004
Resolved 4 May 2004
Resolution: Proved proper operation.
Construction/Loadline › Penetrations › Gasket
Issued 9 October 2002
Resolved
Inspect, operationally test and renew as necessary the drive shaft boots to the satisfaction of the attending marine inspector, prior to carrying passengers. LEGACY COMPONENT DESC: Gasket
Condition: Improper/Lack of Maintenance
Due 15 April 2003
Resolved 3 May 2004
Resolution: Completed during 03MAy04 hull exam.
Lifesaving
Issued 23 August 2001
Resolved
Provide 2 flashlights 1 for the operation station and 1 for the engine room.
Condition: Unknown
Due 7 September 2001
Resolved 1 July 2002
Construction/Loadline
Issued 23 August 2001
Resolved
Prior to carrying passengers make proper repairs to the hull plating on theport wheel well forward side IWO the aft boot.
Condition: Unknown
Due 7 September 2001
Resolved 1 July 2002
Lifesaving
Issued 23 August 2001
Resolved
Replace expired first aid equipment with updated equipment.
Condition: Unknown
Due 7 September 2001
Resolved 1 July 2002
Construction/Loadline
Issued 23 August 2001
Resolved
Prior to carrying passengers properly replace the aft boot.
Condition: Unknown
Due 7 September 2001
Resolved 1 July 2002
Construction/Loadline
Issued 23 August 2001
Resolved
Prior to carrying passengers place a hose clamp on the 12v bilge pump, portside center.
Condition: Unknown
Due 7 September 2001
Resolved 1 July 2002
Construction/Loadline
Issued 23 August 2001
Resolved
Prior to carrying passengers prove proper operation of the Higgins pump with water.
Condition: Unknown
Due 7 September 2001
Resolved 1 July 2002
Lifesaving
Issued 23 May 1997
Resolved
STENCIL THE RING BUOY WITH VESSEL NAME.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Construction/Loadline
Issued 23 May 1997
Resolved
PROVE PROPER OPERATION OF THE CHAIN DRIVEN BILGE PUMP.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Electrical
Issued 23 May 1997
Resolved
PROVIDE A WIRING DIAGRAM FOR THE 12V SYSTEM.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Electrical
Issued 23 May 1997
Resolved
INSTALL A UL APPROVED FOR MARINE USE STARTER AND ALTERNATOR.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Lifesaving
Issued 23 May 1997
Resolved
PROVIDE AN APPROVED RING BUOY WATERLIGHT AND LANYARD.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Engineering
Issued 23 May 1997
Resolved
PROPERLY LABEL THE EMERGENCY FUEL SHUTOFF VALVES.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Electrical
Issued 23 May 1997
Resolved
REHANG THE ENGINE COMPARTMENT WIRING HARNESS SO THAT IT CLEARS THE STEERINGCABLE.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Deck/Cargo
Issued 23 May 1997
Resolved
PROVIDE A SUITABLE ANCHOR AND ANCHOR LINE.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Accommodation/Occupational Safety
Issued 23 May 1997
Resolved
PROPERLY INSTALL THE LOADING LADDER.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Fire Fighting
Issued 23 May 1997
Resolved
PROVIDE AND PROPERLY MOUNT TWO COAST GUARD APPROVED B-II PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Accommodation/Occupational Safety
Issued 23 May 1997
Resolved
INSTALL ALL FIXED SEATING.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Navigation
Issued 23 May 1997
Resolved
INSTALL AND PROVE PROPER OPERATION OF ALL REQUIRED NAVIGATIONAL LIGHTS.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Lifesaving
Issued 23 May 1997
Resolved
STENCIL ALL PFD'S WITH VESSEL'S NAME.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997