Records from 1995 to 2020. Most recent: inspection, 28 April 2020.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 July 2019
Resolved
Electrical equipment on a vessel must be installed and
maintained to:(a) Provide services necessary for safety
under normal and emergency conditions;(b) Protect
passengers, crew, other persons, and the vessel from
electrical hazards, including fire, caused by or
originating in electrical equipment, and electrical
shock;(c) Minimize accidental personnel contact with
energized parts; and (d) Prevent electrical ignition of
flammable vapors. Circuit leading from stbd generator to
a ventilation closure solenoid, shorted and back-fed
current to ground at stbd generator. Engine was isolated
due to rubber gaskets between engine mounts preventing
safe ground. it is believed that the current
found the easiest path through the engines fuel line
causing the fuel line to fail. Provide full analysis of
this deficiency and your repair proposal. Ensure all
materials used are as per manufacturer/regulatory
requirement. Deficiency must be cleared in the presence
of a USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
Resolution: The pull solenoid that releases the hatch/ventilation to the E/R was drawing too much current. Solenoid was removed from service, fuel line was replaced and all engines were properly grounded.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 July 2019
Resolved
The pull solenoid that releases the hatch/ventilation to the E/R was drawing too much current. The ground wire from the solenoid is connected to the battery that the starboard generator uses. O/O added a large ground wire after it was determined there was insufficient grounding on that specific engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2019
Resolved 26 August 2019
Resolution: O/O has decided not to replace solenoid. Emergency procedures have been developed to allow for door to e/r to be closed manually by crew in case of fire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 June 2018
Resolved
A suitable metal marine type strainer, meeting the
requirements of the engine manufacturer, must be fitted
in the fuel supply line in the engine compartment.
Strainers must be leak free. Fuel filter is leaking.
Replace/repair fuel filter to manufacturer
specifications and to ensure leak free.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2018
Resolution: Replaced fuel filter and ensured leak free.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 26 June 2018
Resolved
If a vision waiver is granted, a limitation will be
placed on his or her MMC indicating the mariner may not
serve under the authority of the endorsement unless
corrective lenses are worn and spare lenses are carried
onboard a vessel. Master was unaware of spare lenses
being required. Master must abide by waiver on medical
certificate and provide proof of spare lenses.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2018
Resolution: Master is carrying proof of spare lenses.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 June 2018
Resolved
A vessel on a Great Lakes route must carry—(1) Six hand
red flare distress signals approved in accordance with
§160.021 in subchapter Q of this chapter, or other
standard specified by the Commandant, including, but not
limited to, approval series 160.121; and (2) Six hand
orange smoke distress signals approved in accordance
with §160.037 in subchapter Q of this chapter, or other
standard specified by the Commandant. Additional hand
red flares may replace hand orange flares. Missing correct number of flares. Provide correct number/type of
flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2018
Resolution: Provided correct number/type of flares.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 June 2018
Resolved
A vessel must carry either a first-aid kit approved
under approval series 160.041 or a kit with equivalent
contents and instructions. For equivalent kits, the
contents must be stowed in a suitable, watertight
container that is marked “First-Aid Kit”. First aid kit
contents expired/missing. Replace required contents of
first aid kit with unexpired/missing items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
Resolution: Replaced required contents of first aid kit with unexpired/missing items.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2018
Resolved
All machinery and equipment must be installed and
maintained in such a manner as to afford adequate
protection from causing fire, explosion, machinery
failure, and personnel injury. Starboard engine exhaust
is leaking. Repair leaking exhaust as per regulations
and manufacturer specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2018
Resolution: Repaired leaking exhaust as per regulations and manufacturer specifications.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2018
Resolved
Galley was found to have grease over the griddle (fire
hazard) and needed thorough cleaning behind equipment
and on the deck. Clean to the satisfaction of attending
USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2018
Resolution: Cleaned to the satisfaction of attending USCG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2018
Resolved
At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire
hazards, and other hazardous situations must be
corrected and all required guards and protective devices
must be in satisfactory condition. Decorative rope
ligting on 01 deck, E/R bilge alarm wire and E/R hatch
solinoid wire not well supported. Support wires to the satisfaction of attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2018
Resolution: Wires supported
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2018
Resolved
Each floating waterlight must be approved in accordance
with §161.010 in subchapter Q of this chapter, or other
standard specified by the Commandant, including, but not
limited to, approval series 160.110. Waterlight battery
was not changed out as per manufacturer and was expired.
Change waterlight battery and mark with date of install.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2018
Resolution: New waterlight battery installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 June 2018
Resolved
the stability letter must be posted under glass or other
suitable transparent material, such that all pages are
visible, at the operating station of the vessel.
Stability letter posted was not most recent. Post most
current stability letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
Resolution: Posted correct stability information.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 26 June 2018
Resolved
The emergency instructions must be designed to address
the particular equipment, arrangement, and operation of
each individual vessel. Emergency instructions posted
did not follow the actual actions of the ship's crew in
case of a Man Overboard (MOB). MOB instruction made note
of crew member entering water to assist MOB which is
unsat. Make posted emergency instructions as to the
actual emergency practices of the vessel and drill
procedures of the crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2018
Resolution: Posted emergency instructions as to the actual emergency practices of the vessel and drill procedures of the crew.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 15 August 2017
Resolved
Door to ventilation in E/R was not closing when testing fixed FM-200 system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2017
Resolved 16 August 2017
Resolution: Tested in presence of attending Marine Inspector; all SAT.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 August 2017
Resolved
COI was not posted such that all pages are visible
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 20 September 2017
Resolution: COI Posted
Navigation › Piloting/Steering › Marine Charts
Issued 15 August 2017
Resolved
Adequate and up-to-date charts were not available. Operator stated and provided electronic charts but could not provide proof of the charts being "official electronic charts" as per NVIC 01-16.
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 20 September 2017
Resolution: Satisfactory charts available
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 August 2017
Resolved
Persons used as kitchen staff were being used in safety sensitive positions (firefighting) and were not enrolled in a random chemical drug testing program. see MSA 06-16
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 19 October 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting › Fire Pumps › Arrangement
Issued 15 August 2017
Resolved
Fire pump intake hose from sea chest was rubbing on metallic knife edge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 20 September 2017
Resolution: Chaffing gear in place to prevent damage to fire pump intake
Construction/Loadline › Structures › Superstructure
Issued 15 August 2017
Resolved
Window was broken on bridge
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 12 December 2017
Resolution: New window has been installed. See pictures attached to this activity.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 August 2016
Resolved
Provide required contents of first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 31 August 2016
Resolution: Received confirmation from POC that all required contents for the first aid kit are onboard.
Lifesaving › Lifebuoys › Serviceable
Issued 16 August 2016
Resolved
Provide ring life buoy with serviceable grabline and life line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 16 August 2016
Resolution: Replaced ring life buoy.
Electrical › Electrical Distribution System (service) › Cable
Issued 16 August 2016
Resolved
Provide wiring/cable supports and protection within engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 31 August 2016
Resolution: Received confirmation from POC that required protection / supports installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 16 August 2016
Resolved
Provide FCC Safety Certificate for VHF radio installation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 26 June 2018
Resolution: Provided FCC Safety Certificate
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 16 August 2016
Resolved
Provide Substance Abuse Professional Contact Information
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 31 August 2016
Resolution: Received confirmation from POC attesting to posting required information.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 August 2014
Resolved
Prove proper operation of bilge high water alarms, both audible and visual to correctly identify each individual space.
Action required: 705 - Other - as specified
Due 10 September 2014
Resolved 15 September 2014
Resolution: Attended vessel and witnessed sat ops.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 3 June 2014
Resolved
Complete DAPI requirements; Maintain records for each employee for entire employment period. Records must be maintained in a secure location.
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 25 August 2014
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 3 June 2014
Resolved
Provide proof of each Master holding a Radio Operators Permit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2015
Resolved 10 August 2015
Resolution: Received email copy of radio operators permit.
Documentation › Certificates/Documents › Stability Letter
Issued 3 June 2014
Resolved
Post Stability Letter in Pilot House.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2014
Resolved 25 August 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 June 2014
Resolved
Replace battery floating water light (Replace annually or by expiration marked on battery). Vessel is limited to day time operation until corrected.
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 25 August 2014
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 3 June 2014
Resolved
Provide on board up to date Rules of the Road (Ed D). Extended req 30 days.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2014
Resolved 19 June 2015
Resolution: Master has handbook downloaded on his laptop and ipad which can produce book within required time.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 3 June 2014
Resolved
Replace rotted / broken paddles at next haul out. (Identified 2 with a small amount of rot/broken/missing sections).
Action required: 705 - Other - as specified
Due 30 April 2015
Resolved 26 May 2015
Resolution: New boards and associated hardware installed.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 3 June 2014
Resolved
Properly ground Bilge alarms and Fire Hatch releasing mechanism. (Bilge alarm and fire hatch mechanism are grounded to hull).
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 25 August 2014
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 3 June 2014
Resolved
Prove proper operation of engine room fire hatch. (Hatch releasing mechanism inoperative).
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2014
Resolved 25 August 2014
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 3 June 2014
Resolved
Remove combustibles within main galley refer. (Aft refer requires house keeping with excessive amount of grease and comestibles on deck below unit).
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2014
Resolved 25 August 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 June 2014
Resolved
Properly wire water heater in galley. (Exposed wires at connections).
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 25 August 2014
Engineering › Bilge Water Management System › Hose
Issued 3 June 2014
Resolved
Replace portable bilge pump hose. (Cracked).
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2014
Resolved 25 August 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 June 2014
Resolved
Remove electrical extension cords used throughout vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2014
Resolved 25 August 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 June 2014
Resolved
Make proper electrical connections for the starboard battery barrel switch. (Exposed wires).
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 25 August 2014
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 3 June 2014
Resolved
Replace missing fasteners for the starboard generator top access cover.
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 25 August 2014
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 June 2014
Resolved
Provide cap for MSD discharge pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2014
Resolved 25 August 2014
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 3 June 2014
Resolved
Replace fuel hose and copper line for the starboard MDE. (Leaking)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2014
Resolved 25 August 2014
Engineering › Fuel Oil Service System › Hose
Issued 3 June 2014
Resolved
Replace return line from injector to fuel pump. (Leaking)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2014
Resolved 25 August 2014
Engineering › Fuel Oil Service System › Hose
Issued 3 June 2014
Resolved
Replace fuel supply line to port MDE. (Chaffed where line passes through longitudinal).
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2014
Resolved 25 August 2014
Engineering › Bilge Water Management System › Valve
Issued 3 June 2014
Resolved
Properly label bilge discharge line. (Use and direction of operation).
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 25 August 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 June 2014
Resolved
Repair leak in starboard MDE and Generator exhaust lines between fiberglass elbow and flexible hose connection. Requirement extended as haul out required to correct deficiency.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2015
Resolved 17 June 2015
Resolution: Received notification from maintenance supervisor that new metal elbows with welded flange installed covered with lagging. Installation verification completed with photo submitted and filed. Shall view during annual inspection.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 27 May 2014
Resolved
Correctly label the emergency fuel shutoff valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2014
Resolved 3 June 2014
Resolution: Corrected prior to departure.
Lifesaving › Hand Flares › Quantity
Issued 17 August 2011
Resolved
Provide the proper amount of flares IAW 46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 26 September 2011
Resolution: Vessel now has the appropriate of approved flares O/B.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 17 August 2011
Resolved
Provide loading marks as per the stability letter IAW 46 CFR 178.230
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 26 September 2011
Resolution: Vessel now has a loading mark on its hull.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 August 2011
Resolved
Provide hydro testing for fixed fire fighting container IAW 46 CFR 181.410
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2011
Resolved 13 September 2011
Resolution: According to NFPA 2001 and NVIC 3-95 Hydro testing for Clean Agent containers is not required.
Engineering › Fuel Oil Service System › Gauge
Issued 17 August 2011
Resolved
Provide proper operation for the lube oil gages at the operating station.
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 26 September 2011
Resolution: The lube oil gage was replaced and verified to be in working condition.
Lifesaving › Lifebuoys › Serviceable
Issued 17 August 2011
Resolved
Renew ring buoy’s life line IAW 46 CFR 180.70 (c).
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 26 September 2011
Resolution: Verified that the required ring buoy line was renewed and installed.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 17 August 2011
Resolved
Provide training for supervisors for the DAP IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 11 September 2012
Engineering › Bilge Water Management System › Manifold
Issued 17 August 2011
Resolved
Provide operating instruction for bilge system IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 26 September 2011
Resolution: verified that that instruction have been installed and are accurate to the bilge operating system.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 17 August 2011
Resolved
Provide proposal for repairs or modification to the rudder. IAW 46 CFR 176.700.
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 11 September 2012
Construction/Loadline › Hull › Hull Plating
Issued 23 July 2008
Resolved
Crop and renew damaged area of starboard side shell and bottom plating as necessary to complete insert of a 18"x30" minimum. Insert must be installed a minimum of 6" forward of bulkhead from lazeratte and the number 3 void.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 30 April 2009
Construction/Loadline › Structures › End Bulkhead
Issued 23 July 2008
Resolved
Grind and weld keelson and plate within the number 3 void aft starboard.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 29 April 2009
Construction/Loadline › Penetrations › Pipe Flange
Issued 23 July 2008
Resolved
Lazeratte portside; weld pipe penetration for waste line.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 29 April 2009
Electrical › Electric Supply System (service) › Battery Charger
Issued 3 October 2007
Resolved
Submit electrical one line drawing for suggested repair to vessels steering circuit. Vessel shall not operate as a commercial passenger vessel until approved and completed to the satisfaction of the attending CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2007
Resolved 5 October 2007
Resolution: Rcvd drw which depicted arrangement for port main engine to mirror starboard. Drw did not provide wire sizing however engineer provided specs for cabling and wiring. Copies of original approved MSC approved drawing to be provided for review next week
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 3 October 2007
Resolved
Vessel’s route is here by restricted to the following, as well both bow thrusters must be operational prior to 2008 operating season. Vessel shall not operate as a commercial passenger vessel with sustained winds of 20 knots or more.
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 29 September 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 20 September 2006
Resolved
Place (1) A-II or B-II Class fire extinguisher in galley space, and (2) Class A-II's in accomodation spaces (1 A-II per each accomodation space).
Action required: 705 - Other - as specified
Due 3 October 2006
Resolved 3 October 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 September 2006
Resolved
Vessel is limited to daytime operations until adequate water light on ring life buoy is provided.
Action required: 705 - Other - as specified
Due 3 October 2006
Resolved 20 September 2006
Resolution: Water light receipt was received via fax at the Inspections office. Water light was installed adequately to the ring life buoy.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 September 2006
Resolved
Prior to operating next year, make modifications to bow ramp or provide alternative means to recover helpless person form the water.
Action required: 705 - Other - as specified
Due 2 April 2007
Resolved 28 November 2006
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 20 September 2006
Resolved
Properly segregate child-size lifejacket from adult-size lifejacket stowed on the lower deck.
Action required: 705 - Other - as specified
Due 3 October 2006
Resolved 3 October 2006
Resolution: Installed shelf under stairwell for child size pfds.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 September 2006
Resolved
Reinstall covers on speaker system junction boxes.
Action required: 705 - Other - as specified
Due 3 October 2006
Resolved 3 October 2006
Engineering › Bilge Water Management System › Pump
Issued 30 August 2005
Resolved
Provide Portable Bilge pump of adaquate length to pump deepest bilge pocket.
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 14 September 2005
Engineering › Bilge Water Management System › Valve
Issued 30 August 2005
Resolved
Install check valves as required in fixed bilge pump system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 14 September 2005
Engineering › Fuel Oil Service System › Valve
Issued 30 August 2005
Resolved
Install plug or cap or remove valve on fuel supply line at tank.
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 14 September 2005
Construction/Loadline › Penetrations › Weld
Issued 14 September 2004
Resolved
Weld pipe flange IWO aft bar sink leading to void.
Due 14 September 2004
Resolved 28 September 2004
Resolution: Received fax notification attesting to the satisfactory weld of flange. Visual inspection shall be completed during next annual inspection.
Construction/Loadline › Penetrations › Gasket
Issued 14 April 2004
Resolved
Provide rubber gasket material on all five void space flush deck hatches. LEGACY COMPONENT DESC: Gasket
Due 7 May 2004
Resolved 14 September 2004
Resolution: New gasket material installed and found to be in operable conditions, inspected voids during inspection of piping and electrical inspection. All sat...
Engineering › Diesel Engine (propulsion-direct drive) › Connecting Rod
Issued 14 April 2004
Resolved
Install chaffing gear around both sides of hydraulic lines for propulsion under the protection covers for the paddle wheel.
Due 7 May 2004
Resolved 14 September 2004
Resolution: New lines installed with proper lead to fittings thus no chaffing gear required however installation of additional material to areas historically problem from chaffing.
Accommodation/Occupational Safety › Occupational Safety
Issued 21 July 2003
Resolved
Conduct static load test for passenger ramp LEGACY COMPONENT DESC: Lifeline
Due 23 August 2003
Resolved 7 April 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 21 July 2003
Resolved
Secure loose hydraulic oil filter on both main engines.
Due 23 August 2003
Resolved 7 April 2004
Lifesaving › Lifebuoys
Issued 21 July 2003
Resolved
Replace battery in light. LEGACY COMPONENT DESC: Self-igniting Lights
Due 23 August 2003
Resolved 7 April 2004
Operations/Management › Lifesaving
Issued 21 July 2003
Resolved
Install medical supplies for first aid kit IAW 46 CFR 160.041
Due 23 August 2003
Resolved 7 April 2004
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 23 October 2002
Resolved
Provide proof of servicing for engine room fixed fire fighting system.
Due 23 November 2002
Resolved 21 November 2002
Resolution: Received copy of servicing receipt. Inspection done 11/22/02.
Lifesaving › Lifebuoys
Issued 23 October 2002
Resolved
Replace grabline on ring life buoy.
Due 23 November 2002
Resolved 23 November 2002
Resolution: Grabline replaced on ring life buoy.
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 October 2002
Resolved
Replace expired items from first aid kit. (aspirin, eyewash)
Due 23 November 2002
Resolved 23 November 2002
Resolution: Spoke with master...he disposed and will purchase new at start of season.
Documentation › Certificates/Documents
Issued 23 October 2002
Resolved
Provide copy of updated certificte of documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 23 November 2002
Resolved 23 November 2002
Resolution: New document received by vsl on 11/19. Posted in wheelhouse.
Construction/Loadline
Issued 24 July 2001
Resolved
Finish welding vent pipe to hull connection for the #5 compartment vent pipe.
Condition: Unknown
Due 29 August 2001
Resolved 30 August 2001
Lifesaving
Issued 24 July 2001
Resolved
Renew the line on the bow ramp for hoisting and lowering.
Condition: Unknown
Due 29 August 2001
Resolved 30 August 2001
Lifesaving
Issued 24 July 2001
Resolved
Replace the waterlight battery.
Condition: Unknown
Due 29 August 2001
Resolved 30 August 2001
Fire Fighting
Issued 21 August 2000
Resolved
PERMANENTLY LABEL EMERGENCY FIRE PULL
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Navigation
Issued 21 August 2000
Resolved
PROVIDE COMPASS DEVIATION TABLE
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Electrical
Issued 21 August 2000
Resolved
PROVIDE ELECTRICAL MAT BELOW MAIN ELECTRICAL PANEL
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Fire Fighting
Issued 27 September 1999
Resolved
REPLACE SUICIDE NOZZLE ON FIRE STATION WITH ALL PURPOSE NOZZLE WITH FOR/STRAIGHT STREAM OPTION.
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Accommodation/Occupational Safety
Issued 27 September 1999
Resolved
MAKE PERMANENT REPAIRS TO HEAD SEWAGE DRAIN LINE ELBOW IN AFT COMPT, PORT SIDE.
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Accommodation/Occupational Safety
Issued 27 September 1999
Resolved
INSTALL 3/4 FULL LEVEL INDICATOR FOR SEWAGE HOLDING TANK.
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Engineering
Issued 27 September 1999
Resolved
THIS OFFICE TO BE NOTIFIED WHEN BOW THRUSTER REPAIRS ARE COMPLETED.
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999