MAURY USCG vessel records Sign in
← All vessels

CALLISTO EXPLORER

CALLISTO EXPLORER is a 1969 research vessel. The Coast Guard has recorded 90 inspections since 1985, most recently in May 2017, along with 96 deficiencies.

Records from 1985 to 2017. Most recent: inspection, 20 May 2017.

Built
1969
Last inspected
20 May 2017
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8978655 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE5056
Flag
UNITED STATES
366894000, 367361440 (licence lapsed)
Maury page id
psix-46260

Inspections, by type

…with no type recorded21
Years with a record 26 calendar years (1985–2017)
The 90 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)103.7 ft × 21.0 ft × 7.6 ft
Registered tonnagegross 98 / net 71
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN, RI, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
71 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE5056MMSI 367361440 · expired · compulsorily equipped · granted 6 June 2008, cancelled 11 August 2018 · licensed under a name not among this hull’s recorded names (not shown)
WDC4583MMSI 366894000 · expired · compulsorily equipped · granted 24 March 2005, cancelled 30 May 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCW7786MMSI not assigned · cancelled · compulsorily equipped · granted 31 July 1996, cancelled 12 May 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 90

20 May 2017 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6165626
7 June 2016 Type not recorded
No type recorded · Station Chetco River · USCG Northwest District (CGD-NW) · Activity 5900132
12 May 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5875335
17 June 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4815611
7 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203718
18 March 2010 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3698796
12 June 2008 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3232221
12 June 2008 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3233804
27 March 2008 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3177480
21 July 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2724360
6 April 2005 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2327800
28 February 2005 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2305274
23 May 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1821612
13 May 2003 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1777828
8 July 2002 Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1644892
17 May 2002 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1616802
10 April 2002 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1602348
5 September 2001 Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1376737
23 July 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 718056
20 July 2001 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1070952
19 July 2001 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 152357
25 May 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 121446
21 May 2001 Re-Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1412293
20 March 2001 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1366241
4 May 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1365747
22 March 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1466108
31 August 1999 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 781311
19 July 1999 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 184069
24 May 1999 COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1365224
13 August 1998 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 113491
28 July 1998 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 757928
17 July 1998 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 210502
29 June 1998 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1127680
1 June 1998 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1127382
22 May 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1372263
7 April 1998 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1375335
3 March 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1381148
9 February 1998 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1109425
28 January 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 782418
7 June 1997 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 33922
9 May 1997 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1364164
22 April 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1091992
25 March 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1447686
11 September 1996 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1262118
8 August 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1088389
6 May 1996 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 871810
1 May 1996 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 163433
29 April 1996 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1427201
18 April 1996 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1081996
6 October 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1355474
13 June 1995 Examination of Repairs
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 877406
13 June 1995 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1187218
3 May 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 163865
27 April 1995 Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 865735
10 May 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 869840
6 May 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1171671
13 May 1993 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1376938
10 February 1993 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1376919
21 July 1992 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 218497
10 June 1992 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1401627
5 June 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1267027
2 June 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 160269
28 May 1992 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1265577
5 May 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 944531
5 May 1992 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1399761
29 April 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1268494
24 February 1992 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1258787
3 February 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 951730
4 December 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1211168
20 November 1990 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1227999
14 June 1990 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1225755
27 March 1990 Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 916134
2 August 1989 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1205028
30 June 1989 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1194880
24 February 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1350464
18 January 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 893782
9 August 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1343120
6 July 1988 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1208296
19 November 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1332249
28 August 1987 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1002820
17 July 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1327484
15 June 1987 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1008235
12 October 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1007872
10 October 1986 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1007871
21 August 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 987014
25 June 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1302834
19 June 1986 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 993887
19 May 1986 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 994896
6 January 1986 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 988219
19 June 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 988053

Deficiency record · 96

Communications › Alarms/Indicators › Bilge Alarm
Issued 17 June 2014 Resolved
Replace the lighting for the high bilge alarm panel on the bridge.
Due 1 July 2014
Resolved 1 July 2014
Resolution: Replaced high bilge alarm panel on the bridge.
Electrical › Electric Generation Source (service) › Panelboard
Issued 17 June 2014 Resolved
Insert overhead panels to cover exposed lighting and wires.
Due 1 July 2014
Resolved 1 July 2014
Resolution: Inserted overhead panels.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 17 June 2014 Resolved
Replace alcohol swipe.
Due 1 July 2014
Resolved 1 July 2014
Resolution: Replaced alcohol swipe.
Construction/Loadline › Hull › Weld
Issued 18 March 2010 Resolved
Two welds on starboard hull, both approximately 30 ft. aft, and one weld on port bow, approximately 25 ft. aft, are in unsatisfactory condition. Grind out and weld IAW the standards of NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2010
Resolved 5 April 2010
Resolution: Proper welds were completed.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 12 June 2008 Resolved
Air receiver, located in the engine needs to be properly inspected. Air receiver has passed it's inspection date and needs to visually inspected inside and also it's pressure (MAWP) needs to be tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 13 June 2009
Resolution: Inspectors witnessed proper air receiver test. All sat.
Personnel › Training › First Aid/CPR
Issued 12 June 2008 Resolved
Need to provide proper first-aid/CPR certification/cards for at least 50% of all crewmembers on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 26 November 2008
Resolution: Proper first-aid and CPR cards have been updated and provided for over 50% of crew members.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 12 June 2008 Resolved
Need to provide a proper safety radio telephone certificate via the FCC.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 26 November 2008
Resolution: Vessel has been issued a new and updated safety radio telephone certificate.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 June 2008 Resolved
Need to provide a replacement bulb for the emergency light fixture, located in the M-POD accomdation space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 26 November 2008
Resolution: Proper lighting has been provided for the emergency light fixture, located in the M-POD accomdation space.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 June 2008 Resolved
Provide proper machinery guards for all moving parts that are exposed in the engine room compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 26 November 2008
Resolution: Proper machinery guards have been installed inside the engine room.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 June 2008 Resolved
Need to provide proper blank for the electrical box located in the engine room, blank fuse should provide.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 26 November 2008
Resolution: Proper blank was provided for electrical box located in the engine room.
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 12 June 2008 Resolved
Need to properly and completely test the air receiver located in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 20 June 2008
Construction/Loadline › Penetrations › Valve Flange
Issued 12 June 2008 Resolved
Need to properly cap-off thru fitting on the port-side located in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 26 November 2008
Resolution: The port side thru hull fitting installed was as an air vent for the shaft housing.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 June 2008 Resolved
Need to provide a cover for the emergency light fixture located in the A-Pod.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 26 November 2008
Resolution: Proper lighting has been provided for the emergency light fixture, located in the A-POD accomdation space.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 June 2008 Resolved
Proplery re-new lagging/installation on the Port-engine exhaust, located in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 26 November 2008
Resolution: New lagging has been installed on the port engine exhaust, located in the engine room.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 June 2008 Resolved
Provide second hose clamp for sea-water suction piping on the starboard side located in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 26 November 2008
Resolution: Properly hosed clamped the sea-water suction piping with a second hose clamp.
Personnel › Training › First Aid/CPR
Issued 12 June 2008 Resolved
Need to provide proper CPR cards for at least 50% of the crew onboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 20 June 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 June 2008 Resolved
Need to provide proper emergency lighting to the M-Pod berthing area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 20 June 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 June 2008 Resolved
Need to provide proper machinery guards for all moving parts that exposed in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 20 June 2008
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 12 June 2008 Resolved
Need to provide a proper blank for the electrical box located in the engine room, blank should properly cover the exposed opening.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 20 June 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 June 2008 Resolved
Need to properly cap-off thru hull fitting on port-side located in the the engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 20 June 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 12 June 2008 Resolved
Need to provide a proper cover for emergency lighting in A-Pod.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 20 June 2008
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 12 June 2008 Resolved
Need to properly provide new lagging/insulation on the Port-engine exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 20 June 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 June 2008 Resolved
Need to properly provide a second hose clamp for the starboard side keel-cooler intake, located inside the engine.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 20 June 2008
Construction/Loadline › Structures › Superstructure
Issued 9 June 2008 Resolved
Need to provide U/T shots with a grid pattern with approximate 6ft spread, thus will provide a baseline of the hull thickness, compared to the original scantlings.
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 11 June 2008
Resolution: Audio Gauging provided by Ocean Marine Services.
Construction/Loadline › Penetrations › Weld
Issued 9 June 2008 Resolved
Need to complete and NDT, for insert, visually inspected weldment. Issued a requirement to owner/operator that a Non-destructive test (NDT) would be required to ensure 100% penetration of filler metal.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 11 June 2008
Resolution: Completed NDT, by Oceanview Marine Services. Oceanview provided documentation.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 9 June 2008 Resolved
Need to provide and an updated Safety Radio Telephony Certificate, via FCC.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 20 June 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 21 July 2006 Resolved
Vessel could not provide proof of enrollment in Drug & Alchol program. Vessel does not have an official crew assigned, but must provide proof of enrollment in program prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Communications › Radio Communications › EPIRB
Issued 21 July 2006 Resolved
Vessel did not have EPIRB properly registered.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 July 2006 Resolved
Vessel to update and maintain lifesaving log on survival craft, rescue boat and launching appliances as required by 46 CFR 185.702
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 July 2006 Resolved
Vessel to update navigation publications to 2006.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Lifesaving › Visual Distress Signals (General) › Expired
Issued 21 July 2006 Resolved
Vessel visual distress signals expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Communications › Audible Communications › SPD (Other)
Issued 21 July 2006 Resolved
Vessel public address system inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Communications › Radio Communications › EPIRB
Issued 21 July 2006 Resolved
EPIRB hydrostatic release expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Engineering › Bilge Water Management System › Not Operational
Issued 21 July 2006 Resolved
Bilge high level alarm system inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Construction/Loadline › Structures › Machinery Space Opening
Issued 21 July 2006 Resolved
Repair salt water leak above starboard generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 21 July 2006 Resolved
Remote shutdown of #2 Main Diesel engine failed to shut engine down.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 July 2006 Resolved
Install proper covers on electrical boxes in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 21 July 2006 Resolved
Tachometer of #2 Main Diesel Engine did not operate properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 21 July 2006 Resolved
Provide proper cover/shielding of light fixtures in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 July 2006 Resolved
Vessel to prove proficiency of crew by performing Fire, Man Overboard and Abandoned Ship drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Lifesaving › Inflatable Liferafts › Servicing
Issued 21 July 2006 Resolved
Vessel to have annual servicing of liferafts performed and documented.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Engineering › Freshwater System (intermediary cooling)
Issued 8 July 2002 Resolved
Effect permanent repairs to main engine keel cooler starboard side in way of frame #26 repair to be completed prior to next operating season (2003).
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 13 May 2003
Construction/Loadline › Structures
Issued 17 May 2002 Resolved
Improper previous repairs completed to deck plating outboard and above port main engine. Complete proper repairs during next lay up period, but NLT 31 December 2002. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 17 May 2002
Construction/Loadline
Issued 5 September 2001 Resolved
EFFECT PERMANENT REPAIRS TO THE HULL IN WAY OF THE PORT MAIN DIESEL ENGINE KEEL COOLER AMIDSHIP AFT.
Condition: Unknown
Due 26 September 2001
Resolved 13 May 2003
Navigation
Issued 20 July 2001 Resolved
Effect permanent repairs to the vessel's radar. In the interim, the vessel is restricted to daylight operations only. During the night and/or during periods of restricted visibility of 2 nautical miles or less, the vessel shall remain moored or anchored. A lookout shall be posted while underway.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 21 May 2001 Resolved
AT NEXT DDX RENEW DETERIORATED LONG STFNR PORT FWD CORNER OF ENG RM. PROVIDE GAGE REPORT OF AFFECTED AREA TO COGNIZANT OCMI.
Condition: Unknown
Due 22 March 2002
Resolved 13 May 2003
Lifesaving
Issued 4 May 2000 Resolved
PRIOR TO SAILING CONDUCT PROPER MAINTENENANCE ON RESCUE BOATFALL.
Condition: Unknown
Due 4 May 2000
Resolved 9 May 2000
Accommodation/Occupational Safety
Issued 4 May 2000 Resolved
BROCKEN GLASS IN 3 PORTLIGHTS STBD SIDE 1 ON PORTSIDE. REPLACE GLASS IN KIND. PRIOR TO REPLACING GLASS, DEAD COVERS MUST REMAIN SECURED.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Accommodation/Occupational Safety
Issued 4 May 2000 Resolved
EXCESSIVE WASTAGE IN OVERHEAD ABOVE STBD GENERATOR. PROVIDE TEMP REPAIRS TOAREA WITH A FIRE RESISTANT MATERIAL. AT NEXT YARD PERIOD RELACE WASTED METEL IN KIND.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Fire Fighting
Issued 22 May 1998 Resolved
BEARING FAILURE ON OLD FIRE PUMP. NEW FIRE PUMP BEING INSTALLED. NEW PUMP INSTALLATION AND OPERATION TO SAT. OF ATTENDING INSPECTOR. FIRE DRILL MUST ALSO BE DONE. NO PASSENGERS ALLOWED ON BOARD UNTIL THIS 835 IS CLEARED. MUST BE CLEARED BY 01 JUNE 1998.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 29 April 1996 Resolved
PLACE RETRO-REFLECTIVE TAPE ON RESCUE BOAT IAW REGS.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Engineering
Issued 29 April 1996 Resolved
REPLACE FLAME INPINGMENT BOWL ON PORT ENGINE.
Condition: Unknown
Due 30 April 1996
Resolved 14 May 1996
Electrical
Issued 29 April 1996 Resolved
PLACE DEAD END WIRING IN J-BOX AT CONTROL UNIT FOR HVAC UNIT.
Condition: Unknown
Due 30 April 1996
Resolved 14 May 1996
Electrical
Issued 29 April 1996 Resolved
PLACE "E" ON E-LIGHTS THROUGHOUT VESSEL.
Condition: Unknown
Due 30 April 1996
Resolved 14 May 1996
Fire Fighting
Issued 29 April 1996 Resolved
REMOVE DEFECTIVE OUTDATED FIRE SENSORS FROM STATEROOMS.
Condition: Unknown
Due 30 April 1996
Resolved 14 May 1996
Electrical
Issued 29 April 1996 Resolved
PLACE BUS BAR AT SWITCHBOARD TO PREVENT GENERATOR PARALLEL.
Condition: Unknown
Due 30 April 1996
Resolved 14 May 1996
Lifesaving
Issued 29 April 1996 Resolved
RENEW FALLS ON RESCUE BOAT WINCH.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Accommodation/Occupational Safety
Issued 29 April 1996 Resolved
REBUILD SEWAGE SYSTEM TO PREVENT OVERFLOWS.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Lifesaving
Issued 29 April 1996 Resolved
REPLACE MISSING LADDER RUNG TO ENGINEROOM
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Documentation
Issued 29 April 1996 Resolved
PROVIDE ADD MEASUREMENT, DOCUMENTATION AND PROOF OF VESSEL UNDER 100 GT DOMESTIC.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Documentation
Issued 29 April 1996 Resolved
PROVIDE PLANS FOR ADD MEASUREMENT CHANGES TO BRING VESSEL BELOW 100 GT AND TO REPAIR SEWAGE SYSTEM.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Electrical
Issued 27 April 1995 Resolved
REPLACE DETERIORATED BATTERY BOX FOR GENERATOR STARTING BATTERY.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Lifesaving
Issued 6 May 1994 Resolved
EXCESSIVE OIL SETTLED IN E/R BILGE AFTER OVERHAULING OF DIESEL ENGINES.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Electrical
Issued 6 May 1994 Resolved
EMERGENCY LIGHTS IN ENGINEROOM AND PILOTHOUSE NOT OPERABLE.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Lifesaving
Issued 3 February 1992 Resolved
PROVIDE AN ADDITIONAL 124 WATERLIGHTS FOR ALL LIFEJACKETS ONBOARD. VESSEL IS RESTRICTED FROM USING OCEANS ROUTE AS SPECIFIED ON CERTIFICATE OF INSPECTION UNTIL ALL LIGHTS ARE PROVIDED.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Documentation
Issued 3 February 1992 Resolved
PROVIDE ONBOARD A VALID FCC RADIO STATION LICENSE TO INCLUDE CLASS A EPIRB.
Condition: Unknown
Due 3 March 1992
Resolved 27 February 1992
Documentation
Issued 3 February 1992 Resolved
PROVIDE ONBOARD A WASTE MANAGEMENT PLAN AND REFUSE PLACARD FOR MARPOL V REQUIREMENTS.
Condition: Unknown
Due 3 March 1992
Resolved 27 February 1992
Electrical
Issued 14 June 1990 Resolved
RENEW BATTERY COVER FOR THE GENERATOR START BATTERIES.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Deck/Cargo
Issued 14 June 1990 Resolved
REPAIR ANCHOR WINDLASS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990 Resolved
HARD WIRE THE MARINE SANITATION DEVICE PUMPS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990 Resolved
CONDUCT SMALL PASSENGER VESSEL DRILLS IN THE PRESENCE OF A MARINE INSPECTOR(MAN OVERBOARD, FLOODING, FIRE, & ABANDON SHIP).
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990 Resolved
SECURE LIFELINE AROUND THE SIDES OF THE BUOYANT APPARATUSES.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Documentation
Issued 14 June 1990 Resolved
PROVIDE COAST GUARD APPROVAL OF THE CONCRETE BALLAST LOCATED IN THE FOREPEAK.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Deck/Cargo
Issued 14 June 1990 Resolved
REPAIR/REPLACE RELIEF VALVE FOR THE AIR RECEIVER.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Documentation
Issued 14 June 1990 Resolved
PROVIDE VALID FCC LICENSE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Engineering
Issued 14 June 1990 Resolved
REPAIR/REPLACE THE ELECTRICAL BILGE PUMP.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990 Resolved
PROVIDE EMERGENCY LIGHTING AUTOMATICALLY ACTUATED UPON FAILURE OF THE MAIN LIGHTING SOURCE FOR ALL BELOW MAIN DECK LOUNGES.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990 Resolved
REPAIR/REMOVE NIGHT GENERATOR.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Accommodation/Occupational Safety
Issued 6 July 1988 Resolved
HYDROSTSTIC TEST THE AIR RECEIVER TO 1.25 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Accommodation/Occupational Safety
Issued 6 July 1988 Resolved
REPLACE CRACKED WINDOWS IN THE BOW AREA OF THE VESSEL'S MAIN DECK PRIOR TO OPERATING COASTWISE, GREAT LAKES, OR LAKES, BAYS AND SOUNDS; BUT, NO LONGERTHAN THE NEXT SCHEDULED CERT OF INSPECTION (6 JULY 1989).
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Navigation
Issued 6 July 1988 Resolved
PROVIDE AND INSTALL A CLASS C EPIRB IN A READILY ACCESSIBLE LOCATION AT OR NEAR THE PRINCIPAL STEERING STATION.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Unknown
Issued 15 June 1987 Resolved
SEWAGE VENTILATION IN ENGINE ROOM SHOULD BE PERMANENTLY INSTALLED WITH A BREAKER FOR THE FAN AND A PROPER THROUGH HULL FITTING OR REMOVED.
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987
Electrical
Issued 15 June 1987 Resolved
PROVIDE WATER PROOF LIGHT SWITCH COVERS FOR THE SWITCHES IN THE HEADS OF THE WEST VIRGINIA, LOUISIANA AND IDAHO STATE ROOMS.
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987
Electrical
Issued 15 June 1987 Resolved
PROVIDE PROPER SUPPORT FOR ALL WIRES IN PANTRY.
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987
Navigation
Issued 15 June 1987 Resolved
PROVIDE STERN LIGHT AND INSTALL AS PER NAVIGATION RULES.
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987
Lifesaving
Issued 15 June 1987 Resolved
PROVIDE ONE 24 INCH ORANGE RING BUOY.
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987
Engineering
Issued 15 June 1987 Resolved
PROVIDE EXHAUST VENTILATION DUCTING FOR THE ENGINE ROOM AS PER 46CFR182.20-45(C) AND 46CFR182.20-45(D).
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987
Navigation
Issued 10 October 1986 Resolved
EFFECT PERMANENT REPAIRS TO MAIN STEERING CABLE BELOW WHEELHOUSE, IN WAY OFFORWARD SHIPS STOREROOM, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Lifesaving
Issued 25 June 1986 Resolved
PROVIDE FLOAT FREE LINKS FOR BUOYANT LIFESAVING APPARATUS AND REMOVE LASHINGS SECURED BY SHACKLES AND CLIPS.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Electrical
Issued 19 June 1986 Resolved
REMOVE ELECTRICAL OUTLETS AND ROMEX CABLE ON PORT/STBD SHAFT BOXES AND REPLACE WITH PROPER WEATHERTIGHT OUTLET BOXES HARD WIRED WITH APPROVED MARINE CABLE.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Lifesaving
Issued 19 June 1986 Resolved
PROVIDE SIX ORANGE SMOKE AND THREE ADDITIONAL RED SIGNAL FLARES.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Electrical
Issued 19 June 1986 Resolved
REMOVE JURY-RIGGED MSD VENTILATION ARRANGEMENT AND INSTALL PERMANENT HARD WIRED REPLACEMENT.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Construction/Loadline
Issued 19 June 1986 Resolved
BOLT DOWN FORWARD HATCH ABOVE FOREPEAK COMPARTMENT
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Fire Fighting
Issued 19 June 1986 Resolved
COMPLETE REPAIR OF FIRE PUMP TO DEVELOP 60 PSI AT PUMP OUTLET GAUGE.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Fire Fighting
Issued 19 June 1986 Resolved
DEMONSTRATE ALL FOUR FIRE HOSES UNDER PRESSURE
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Lifesaving
Issued 19 June 1986 Resolved
REPLACE LIFEFLOAT SECURING CLIPS WHERE RUSTED.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.