MAURY USCG vessel records
← All vessels

STATIA SUPPLIER

Built
1969
Last inspected
14 March 2008
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 14 March 2008
…with no type recorded24
…past their stated due date3
Operational controls None recorded without a removal date
Years with a record 24 calendar years (1984–2008)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-46263

Documentation record

Tonnage as PSIX records it2770 - Convention (Subpart B), Gross Ton
2504 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 68 inspections, each with its date, unit and type; 36 deficiencies with the resolution recorded against each, 3 without one; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

THOMAS DANN Towing Vessel · MISLE 135955 · 22 March 1997 · activity 30586

Inspection history · 68

14 March 2008 Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3164399
22 January 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3135374
4 June 2007 MTSA Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2951969
23 May 2007 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2938134
27 April 2007 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2917118
12 July 2006 MARPOL Annex I Examination · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2686891
25 July 2005 Hull Examination · Annual Inspection · Internal Structural Exam · Cargo Tank Internal · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2445011
5 November 2004 MTSA Verification · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2235293
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999710
19 August 2003 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1880577
15 July 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465677
31 August 2000 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 822168
22 July 2000 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1408572
25 August 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 782893
14 July 1999 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1375895
11 August 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368802
30 October 1997 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 781828
23 October 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 459742
12 August 1997 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 783181
11 July 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383605
22 March 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 30586
28 February 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 484322
7 October 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 449565
6 June 1996 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 873182
23 May 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 500306
3 December 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 498976
5 October 1995 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 873793
18 July 1995 COI Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 872803
17 April 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 455523
21 February 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 846567
28 September 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1432836
18 July 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 463646
12 July 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 866677
8 June 1994 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363000
11 August 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 848575
30 June 1993 COI Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 838982
27 October 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1134549
14 October 1992 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1417470
25 September 1992 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1255768
14 September 1992 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 947301
24 October 1991 Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1312889
7 August 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 657293
22 July 1991 Damage Survey · Examination of Repairs · Permit to Proceed
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1252869
6 July 1990 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 931109
8 April 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 908808
26 September 1989 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 995760
17 August 1989 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 888549
15 August 1989 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1349883
11 March 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 891580
22 November 1988 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 893044
22 November 1988 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 894186
15 September 1988 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1042865
16 December 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1021745
19 October 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 464389
12 August 1987 Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1009215
20 July 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1316867
25 June 1987 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1009213
16 March 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1334406
26 November 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 465416
12 November 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 480600
8 July 1986 Credit Drydock · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1297597
31 March 1986 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 506439
6 December 1985 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 989527
12 July 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 456646
27 June 1985 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1299020
13 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1285922
18 August 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 507218
2 August 1984 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 440953

Deficiency record · 36

Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 14 March 2008 No resolution recorded
Vessel service generator not fitted with overspeed device
Action required: 705 - Other - as specified
Due 18 March 2008 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2008 Resolved
Remove Wire Nuts from service generator wiring
Action required: 705 - Other - as specified
Due 18 March 2008
Resolved 14 March 2008
Resolution: Removed Wire Nuts from service generator wiring
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 March 2008 Resolved
Label circuit breakers in distribution panel
Action required: 705 - Other - as specified
Due 18 March 2008
Resolved 14 March 2008
Resolution: Labeled circuit breakers in distribution panel
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 14 March 2008 Resolved
Install Non-Conducting Deck covering in front of distribution panel
Action required: 705 - Other - as specified
Due 18 March 2008
Resolved 14 March 2008
Resolution: Installed Non-Conducting Deck covering in front of distribution panel
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 14 March 2008 Resolved
Discovered 1" fracture of the aft bulkhead of the # 5 port cargo tank. Fracture is located 8" inboard of the fourth side longitudinal down from the deck, 10' from bottom of tank. Fracture is in the immediate vicinity of fourth side shell longitudinal gusset, this gusset is tripped as a result of side shell inset.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 14 March 2008
Resolution: Issued CG-835 restricting innage in the # 5 port cargo tank to 9'''', due to location of fracture and vessel phase out date.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 March 2008 No resolution recorded
Install heat shield covering generator muffler.
Action required: 705 - Other - as specified
Due 18 March 2008 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Switchboard
Issued 14 March 2008 No resolution recorded
Re-attach Drip Shield above switchboard
Action required: 705 - Other - as specified
Due 18 March 2008 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 4 June 2007 Resolved
Overfill protection system inoperative vessel needs to replace Elect circuit cards to repair
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2007
Resolved 4 June 2007
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 27 April 2007 Resolved
33 C.F.R. 151.28(b) The owner or operator shall submit any plan amendments to Commandant (CG-3PCV-1) for information or approval. Plan holder could not be contacted based on current information listed in SOPEP.
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 16 October 2007
Resolution: The SOPEP was approved on 10/16/2007.
Construction/Loadline › Hull
Issued 19 August 2003 Resolved
Crop and Renew STBD side shell section (1) 240" x 86" x 1/2" LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 22 August 2003
Construction/Loadline › Hull › Side Shell
Issued 19 August 2003 Resolved
Crop and renew stbd side shell section (2) 3/4" x 72" x 69".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 22 August 2003
Construction/Loadline › Hull › Side Shell
Issued 19 August 2003 Resolved
Crop and Renew stbd side shell (3) 3/4" x 72" x 69"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 22 August 2003
Construction/Loadline › Hull › Side Shell
Issued 19 August 2003 Resolved
Crop and renew stbd side shell section (4) 3/4" x 72" x 69"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 22 August 2003
Construction/Loadline › Hull › Side Shell
Issued 19 August 2003 Resolved
Crop and renew stbd side shell section (5) 5/8" x 33" x 87"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 22 August 2003
Construction/Loadline › Hull › Side Shell
Issued 19 August 2003 Resolved
Crop and renew stbd side shell section (6) 86" x 20" x 1/2"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 22 August 2003
Construction/Loadline › Hull › Side Shell
Issued 19 August 2003 Resolved
Crop and renews stbd side shell section (A) 35" x 37" x 3/4"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 22 August 2003
Construction/Loadline › Hull › Side Shell
Issued 19 August 2003 Resolved
Crop and renew stbd side shell section (B) 60" x 69" x 1/2"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 22 August 2003
Construction/Loadline › Hull › Side Shell
Issued 19 August 2003 Resolved
Crop and renew stbd side shell section (c) 86" x 49" x5/8"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 22 August 2003
Documentation
Issued 14 July 1999 Resolved
Update vessel transfer procedures to reflect new name and any other pertinent changes accordingly, per 33CFR155.730.
Condition: Unknown
Due 14 August 1999
Resolved 9 September 1999
Documentation
Issued 11 July 1997 Resolved
PROVIDE AMENDED OIL TRANSFER PROCEDURES THAT INCLUDE VCS (VAPOR COLLECTION SYSTEM) INFORMATION AS REQUIRED BY 33 CFR 155.750(d).
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Documentation
Issued 11 July 1997 Resolved
PROVIDE PROOF OF A VALID IOPP CERTIFICATE WITH ANNUAL ENDORSEMENTS AS REQUIRED BY 33 CFR 151.19 (BEFORE GOING ON AN INTERNATIONAL VOYAGE OR 11 AUG 97 WHICHEVER IS SOONER)
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Documentation
Issued 11 July 1997 Resolved
PROVIDE PROOF OF AN APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP)AS REQUIRED BY 33 CFR 151.09
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Electrical
Issued 8 June 1994 Resolved
Clean tops of 24 volt battery system, located in way of the barges generator.
Condition: Unknown
Due 8 June 1994
Resolved 8 June 1994
Electrical
Issued 8 June 1994 Resolved
Provide solder type battery lugs for generator starting batteries. Remove excess wires from battery lugs and install them properly.
Condition: Unknown
Due 8 June 1994
Resolved 8 June 1994
Documentation
Issued 30 June 1993 Resolved
REWRITE VESSEL OIL TRANSFER PROCEDURES & REDRAW DIAGRAM TO REFLECT OPERATION WITH NEW TRANSFER PUMPS.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Deck/Cargo
Issued 14 October 1992 Resolved
PROVE PROPER OPERATION OF STARBOARD CARGO PUMP SHUTDOWN. THIS REQUIREMENT TO BE CLEARED PRIOR TO OPERATION OF CARGO PUMP.
Condition: Unknown
Due 14 November 1992
Resolved 18 November 1992
Electrical
Issued 14 October 1992 Resolved
MAKE PROPER REPAIRS TO WIRING ON GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 November 1992
Resolved 18 November 1992
Deck/Cargo
Issued 22 July 1991 Resolved
VESSEL IS NOT TO CARRY CARGO IN #1 P/S CARGO TANKS UNTIL PERMANENT REPAIRS ARE COMPLETED TO THE SATISFACTION OF COGNIZANT OCMI._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Documentation
Issued 22 July 1991 Resolved
PROVIDE COGNIZANT OCMI A PROPOSAL FOR TEMPORARY & PERMANENT REPAIRS TO CLASS I & II STRUCTURAL FAILURES INVOLVING HULL PLATING & INTERNAL MEMBERS IN #1 P/S CARGO TANKS. NO PERMANENT REAPIRS MAY BE MADE UNTIL PROPOSAL HASBEEN APPROVED._x001C_
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Deck/Cargo
Issued 15 August 1989 Resolved
CONDUCT A SATISFACTORY HYDRO TEST OF THE PORTABLE CARGO HOSES ABOARD THE VESSEL.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Accommodation/Occupational Safety
Issued 15 August 1989 Resolved
CONDUCT A SATISFACTURY HYDRO TEST OF THE NEWLY INSTALLED DECK MACHINERY HYDRAULIC PIPING IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Construction/Loadline
Issued 20 July 1987 Resolved
FRAME WELD TO BOTTOM PLATE WAS RUN TO HOT AND FRACTURE OUT. CROP AND RENEW
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Construction/Loadline
Issued 20 July 1987 Resolved
VARIOUS LONGTITUDINAL INSERTS WERE EITHER NOT WELDED IN THE FIRST PLACE OR POORLY WELDED AND THE WELDS HAD BROKEN AWAY.
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Fire Fighting
Issued 27 June 1985 Resolved
ATTACH THE BV FIRE EXTINGUISHER TO THE DECK IN ACCORDANCE WITH 46 CFR 34.50-5.
Condition: Unknown
Due 27 June 1985
Resolved 27 June 1985
Navigation
Issued 27 June 1985 Resolved
REMOVE THE HOUSEHOLD LIGHTBULBS FROM THE NAVIGATIONAL SIDE LIGHTS AND STERNLIGHT AND REPLACE WITH MANUFACTURERS RECOMMENDED LIGHTBULBS.
Condition: Unknown
Due 27 June 1985
Resolved 27 June 1985
Deck/Cargo
Issued 13 February 1985 Resolved
RENEW 2 1/2 GATE VALVE TO SLOP TANK ON MAIN DECK.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.