JULIET ALICA

JULIET ALICA is a 1969 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1985, most recently in November 2025, along with 57 deficiencies.

Records from 1985 to 2025. Most recent: inspection, 17 November 2025.

Built
1969
Last inspected
17 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBD7640
Flag
UNITED STATES
366945480
Maury page id
psix-46273

Inspections, by type

…with no type recorded7
Years with a record 35 calendar years (1985–2025)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)88.3 ft × 33.0 ft × 6.8 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · WARREN, RI, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKELLEYS ISLAND, OH
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB7640MMSI 366945480 · active · compulsorily equipped · granted 15 May 2024, expires 6 May 2034 · licensed under a name not among this hull’s recorded names (not shown)
WZX5521MMSI not assigned · expired · compulsorily equipped · granted 19 October 1998, cancelled 31 January 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 64

17 November 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8269811
19 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8139359
1 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8116129
23 October 2024 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8023542
9 August 2024 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8016697
5 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7932587
17 May 2023 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7690699
16 June 2022 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7476084
19 May 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7201802
5 November 2020 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7090142
15 September 2020 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7058333
6 May 2020 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6951294
8 August 2019 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6777657
21 August 2018 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6519737
19 July 2017 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6206278
27 September 2016 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6020015
15 September 2016 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6001306
16 September 2015 Drydock Exam · DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5732222
6 July 2011 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4071655
12 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3234818
15 May 2008 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3193927
10 July 2007 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2989611
30 May 2007 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2946496
23 August 2006 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2757417
10 July 2006 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2708248
12 October 2005 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2512885
14 July 2005 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2426864
16 September 2004 Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2197179
21 July 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2140174
25 May 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2077420
27 August 2003 Deadweight Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1888649
20 May 2003 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1797270
10 December 2002 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1717043
8 November 2001 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1362536
1 December 1999 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1391155
9 November 1999 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1375964
8 December 1998 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 813114
18 March 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 773720
17 July 1997 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 100141
18 March 1997 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1424362
23 October 1996 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 530181
22 March 1996 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1078716
12 October 1995 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 484384
2 May 1995 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1179663
29 March 1995 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1416113
17 November 1994 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 446451
8 November 1994 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1179701
25 March 1994 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1440796
24 March 1993 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1149674
12 May 1992 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1265117
19 March 1992 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1319174
15 March 1991 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1304860
27 September 1990 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1222529
29 March 1990 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1230729
4 November 1989 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 866832
3 November 1989 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1318126
5 June 1989 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1350801
31 March 1989 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1030693
29 March 1988 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 996420
7 October 1987 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1321307
31 March 1987 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1019499
1 April 1986 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1306118
23 April 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 983485
4 April 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1289339

Deficiency record · 57

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 May 2021 Resolved
Lifelines were not securely attached around the outside of all 3 lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2021
Resolution: Lifelines secured as required and found to be satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 September 2020 Resolved
The hull structure located at the forward end of the vessel, on which the ramp is attached, has deteriorated welds and several holes in the plating. Crop & renew wasted steel and gouge and refresh welds as indicated.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2020
Resolution: Repairs were made to the satisfaction of attending Marine Inspectors, deficiency was cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 August 2019 Resolved
Repair/Replace retro reflective tape on the three Life Floats on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 12 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 August 2019 Resolved
Repair/Replace retro reflective tape on the three Life rings on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 12 August 2019
Lifesaving › Lifefloat › Paddle
Issued 19 July 2017 Resolved
Ensure 02 broken life float paddles are replaced and all life float paddles are properly marked with vessels name.
Action required: 705 - Other - as specified
Due 9 August 2017
Resolved 10 August 2017
Resolution: New paddles with proper markings were placed on all life floats.
Communications › Public Address System › Loudspeaker
Issued 19 July 2017 Resolved
Ensure PA system is fully operational.
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 10 August 2017
Resolution: PA was tested satisfactory.
Fire Fighting › Fire Main › Condition
Issued 19 July 2017 Resolved
Repair leaking fire main at Fire Station #1 in way of stop valve.
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 18 August 2017
Resolution: Leaking fire main stop valve has been repaired and found leak free.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 19 July 2017 Resolved
Replace all J hook brackets and other methods of securing fire extinguishers with marine type fire extinguisher brackets in the followin locations. 1) baggage rooms 2) engine room.
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 18 August 2017
Resolution: All fire extinguishers are now in approved brackets.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 July 2017 Resolved
Properly seal all deck hatch covers to ensure watertight integrity is met.
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 10 August 2017
Resolution: New gasket material has been installed as required.
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 19 July 2017 Resolved
Install jacket water temperature gauge on generator.
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 10 August 2017
Resolution: Gauage installed and verified operational.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 19 July 2017 Resolved
Tighten packing gland on shaft tube to prevent water intrusion into engine room.
Action required: 705 - Other - as specified
Due 9 August 2017
Resolved 10 August 2017
Resolution: Packing gland on shaft was tighetend and found to be leak free.
Engineering › Bilge Water Management System › Strainer
Issued 19 July 2017 Resolved
Clear out bilge lines and prove proper operation of bilge suction (50 gpm).
Action required: 705 - Other - as specified
Due 9 August 2017
Resolved 10 August 2017
Resolution: Proper operation of bilge suction was demonstrated.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 July 2017 Resolved
Replace all retro material on Kapok style PFD's.
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 18 August 2017
Resolution: Kapok style PFD's have been replaced with new Type I PFD's, all of which are labeled with vessels name and have appropriate amount of retro material.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 19 July 2017 Resolved
Properly mark all PFD's with vessels name and remove other vessels/company names.
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 18 August 2017
Resolution: All PFD's were found properly marked.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 July 2017 Resolved
Install gage over glass light fixture on car deck, or replace with plastic cover.
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 10 August 2017
Resolution: Cage was installed as required.
Construction/Loadline › Structures › Door
Issued 29 September 2015 Resolved
Aft weathertight door leading to engine room has multiple inoperable dogs. Make dogs readily operable IAW 46 CFR 171.124.
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 15 September 2016
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 September 2015 Resolved
Magnetic compass is broken and inoperable. Repair/replace compass and demostrate proper operation IAW 46 CFR 184.20.
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 15 September 2016
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 29 September 2015 Resolved
A glass window in the forward stbd side of the passenger salon is broken. Replace window IAW 46 CFR 177.1010 and 1020.
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 15 September 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 September 2015 Resolved
The bilge high level alarm for the "microphore" compartment exhibits an audible alarm but no visual alarm. Repair light indicator and demonstrate proper operation IAW 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 15 September 2016
Electrical › Electrical Distribution System (service) › Conductor
Issued 15 May 2008 Resolved
Properly install per 183.10-20 the wiring for permanent equipment located at forward outlet of engine room, the pertable wire for air compressor, and fresh water pump.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 19 June 2008
Resolution: Installed proper breaker box and hard wiring.
Electrical › Electrical Distribution System (service) › Switch
Issued 15 May 2008 Resolved
Install disconnect switches for air compressor and potable water pump in accordance with 46 CFR 183.10-25.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 19 June 2008
Resolution: Installed proper disconnect switches.
Electrical › Electric Supply System (service) › Battery Charger
Issued 15 May 2008 Resolved
Battery charger cables for generator starter battery shall be permanently installed. Spring clamps are not allowed in accordance with 46CFR183.05-20(c).
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 19 June 2008
Resolution: Removed spring clamps and hard wired wires to battery
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 May 2008 Resolved
Provide on board most current copies of US Coast Pilot, USCG Light List, and new or updated navigation chart.
Action required: 705 - Other - as specified
Due 16 June 2008
Resolved 19 June 2008
Resolution: Provided copies of all required publications
Fire Fighting › Fire Hoses › Condition
Issued 10 July 2007 Resolved
Replace two worn fire hoses prior to getting underway.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2007
Resolved 10 July 2007
Resolution: Replaced two hoses with new hoses
Lifesaving › Lifeboat Equipment › Oar
Issued 10 July 2007 Resolved
Replace missing life float paddle
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 31 July 2007
Resolution: Replaced missing paddle
Communications › Radio Communications › EPIRB
Issued 10 July 2007 Resolved
Replace antenna on EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 31 July 2007
Resolution: Replaced worn EPIRB antennae
Communications › Visual Communication › Signalling Lamp
Issued 10 July 2007 Resolved
Label emergency escape exit in engine room.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 31 July 2007
Resolution: Installed emergency escape placard
Engineering › Bilge Water Management System › Manifold
Issued 10 July 2007 Resolved
Label bilge system piping
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 31 July 2007
Resolution: Labeled all bilge system piping.
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 July 2006 Resolved
Replace missing compass light.
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 23 August 2006
Resolution: Replaced compass light
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 July 2006 Resolved
Prove proper operation of ground test circuit on main distribution panel.
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 23 August 2006
Resolution: Tested sat
Electrical › Lighting (service) › Lighting Fixture
Issued 10 July 2006 Resolved
Replace missing globe in light asembly fwd blkd in engine room.
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 23 August 2006
Resolution: Installed glass globe in engine room
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 July 2006 Resolved
Remove wire nuts from wires on outside port aft run.
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 23 August 2006
Resolution: Wire nuts were removed and replaced with butt type connectors
Engineering › Fuel Oil Service System › Valve, Control
Issued 10 July 2006 Resolved
Extend & Repair FWD reach rod (remote fule shut off) to make correct opperation.
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 23 August 2006
Resolution: Welded 2inch extension to allow proper operation of reach rod
Engineering › Diesel Engine (propulsion-electric) › Crosshead Assembly
Issued 10 July 2006 Resolved
Clean radiator on center generator set (clogged due to lack of maintenence)
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 23 August 2006
Resolution: Radiator was cleaned to inspectors satisfaction
Communications › Audible Communications › SPD (Other)
Issued 14 July 2005 Resolved
Repair vessels PA system
Due 3 September 2005
Resolved 12 October 2005
Resolution: Vessels reps repaired P/A system with sat results.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 July 2005 Resolved
Replace stenciling on all liferings
Due 3 September 2005
Resolved 12 October 2005
Resolution: Vessels reps stenciled all lefe rings with sat results.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 July 2005 Resolved
Replace bulb in forward flood light
Due 30 November 2005
Resolved 24 January 2006
Resolution: Replaced rare light bulb. Tested with sat results
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 14 July 2005 Resolved
Install a plug back on the port main diesel starter motor.
Due 3 September 2005
Resolved 12 October 2005
Resolution: Vessels reps relaced the missing plug on the starter motor.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 July 2005 Resolved
Remove dead end wires in engine room.
Due 3 September 2005
Resolved 12 October 2005
Resolution: Vessels reps removed the dead end wires from the engine room.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 14 July 2005 Resolved
Cap off sewage tank drain system
Due 3 September 2005
Resolved 12 October 2005
Resolution: Vessels reps installed a 4" camlock cap to the sewage tank piping. All sat.
Engineering › Bilge Water Management System › Valve
Issued 14 July 2005 Resolved
Replace forward bilge valve
Action required: 705 - Other - as specified
Due 3 September 2005
Resolved 29 September 2015
Resolution: Replaced faulty valve
Electrical › Electric Generation Source (service) › Panelboard
Issued 25 May 2004 Resolved
Install safety shield/ cage around main electrical switchboard.
Due 25 June 2004
Resolved 24 June 2004
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 25 May 2004 Resolved
Troubleshoot possible dead ground on main electrical panel and repair to satisfaction of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2004
Resolved 10 June 2004
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 25 May 2004 Resolved
Blanket small generator exhaust elbow.
Due 25 June 2004
Resolved 10 June 2004
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 25 May 2004 Resolved
Install fuel shut off valves on generators.
Due 25 June 2004
Resolved 24 June 2004
Lifesaving › Buoyant Apparatus › Lifeline
Issued 25 May 2004 Resolved
Replace grab line on fiberglass BA.
Due 5 June 2004
Resolved 24 June 2004
Fire Fighting › Fire Hoses
Issued 20 May 2003 Resolved
One fire hose failed hydrostatic test. LEGACY COMPONENT DESC: Condition
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2003
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 10 December 2002 Resolved
Prior to placing the vessel in passenger service, complete annual inspection.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2003
Electrical
Issued 29 March 1995 Resolved
PROVE PROPER OPERATION OF 5 KW NORTHERN LIGHTS GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 April 1995
Resolved 3 May 1995
Lifesaving
Issued 24 March 1993 Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF CG INSPECTOR.
Condition: Unknown
Due 24 April 1993
Resolved 30 April 1993
Lifesaving
Issued 19 March 1992 Resolved
Conduct emergency drills including man overbard, fire and rescue.
Condition: Unknown
Due 19 March 1992
Resolved 19 March 1992
Fire Fighting
Issued 15 March 1991 Resolved
INSTALL RIDGID EXTENSION TO HAND OPERATED BILGE PUMP/
Condition: Unknown
Due 15 March 1991
Resolved 15 March 1991
Navigation
Issued 15 March 1991 Resolved
CONDUCT FIRE, ABANDON SHIP, AND MAN OVERBOARD DRILL
Condition: Unknown
Due 15 March 1991
Resolved 15 March 1991
Electrical
Issued 31 March 1989 Resolved
PROVE OPERATION OF ONAN GENERATOR.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
RENEW EPIRB BATTERIES WITH DATED BATTERIES.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Fire Fighting
Issued 1 April 1986 Resolved
HYDROSTATICALLY TEST FIVE OUTDATED CO2 PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Documentation
Issued 4 April 1985 Resolved
D1. ENSURE THE STERN IS PROPERLY MARKED WITH THE HOMEPORT OR HAILING PORT (CLEVELAND OR SANDUSKY) NO LATER THAN 05MAY85.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.