MAURY USCG vessel records Sign in
← All vessels

ANNOULA

ANNOULA is a 1997 freight ship. The Coast Guard has recorded 21 inspections since 1999, most recently in February 2012, along with 8 deficiencies — 1 with no resolution recorded — and 6 operational controls.

Records from 1999 to 2012. Most recent: inspection, 24 February 2012.

Built
1997
Last inspected
24 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9146015 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
462821
Flag
GREECE
—
Maury page id
psix-462821

Inspections, by type

…with no type recorded11
…past their stated due date1
Years with a record 10 calendar years (1999–2012)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it23279 - Convention (Subpart B), Net Ton
36559 - Convention (Subpart B), Gross Ton
70281 - Dead Weight, Ton
79422 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

24 February 2012 ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4245114
14 December 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3910064
12 February 2010 ISPS I Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3676440
12 February 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3679447
11 February 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3678979
19 February 2009 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3414749
17 February 2009 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3419347
2 December 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3372489
28 November 2008 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3370636
28 November 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3370762
13 January 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3129567
10 January 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3129413
5 January 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3125249
24 January 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2861207
23 June 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2400694
13 October 2004 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2219747
21 September 2003 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1909602
17 September 2003 Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 1909458
6 March 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 275664
21 January 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 273758
17 February 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 425681

Deficiency record · 8

Engineering › Fuel Oil Service System › Piping
Issued 14 December 2010 Resolved
0710 Noted during PSC Exam diesel oil actively leaking from #2 Ship's Service Generator. Diesel oil was observed leaking and accumulating in bilge creating a potential fire hazard due to flammable liquids and vapors. Vessel is to make necessary repairs and/or adjustments to #2 Generator to secure leaking. 17ac SOLAS 74(04cons) II-2 Reg 4.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 December 2010
Resolved 17 December 2010
Resolution: Seals replaced and fittings tightened. Coast Guard and Class witnessed proper operation of Generator.
Lifesaving › Launching Appliances › Release Mechanism
Issued 2 December 2008 Resolved
74SOLAS (1997 Cons) CHIII Reg 48.1.4: The vessel's port and starboard release mechanism is not properly attached to the inside of the lifeboat. Class to attest to the proper operation of the port and starboard release mechanisms
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2008
Resolution: Class verified launching mechanism was installed and verified attached to both port and STBD side lifeboats.
Electrical › Electric Generation Source (emergency) › Generator
Issued 2 December 2008 Resolved
74SOLAS (1997 Cons) CHIII-1 Reg 43.2: The emergency generator is inoperable. Neither of the two banks of batteries would start the generator with a full charge. Class to determine the cause of the starting failure and attest to proper repairs prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2008
Resolution: Class verified repairs made and emergency generator in good working order.
Fire Fighting › Fire Pumps › Casing
Issued 2 December 2008 No resolution recorded
74SOLAS (1997 Cons) CHI Reg 11: The emergency fire pump failed to get suction when first started. Adequate fire pressure was observed after the friction coupling and sheet was replaced and the system was primed by the general service pump. Class to verify repairs and attest to the proper operation of the emergency fire pump. (Class verified temp. repairs . See attached class report)
Action required: 705 - Other - as specified
Due 2 February 2009 — due date passed with no resolution recorded
Resolution: Verified class report clearing deficiency and witnessed satisfactory test of emergency fire pump.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 2 December 2008 Resolved
MARPOL Annex V Reg 9(3) the garbage record book contained entries that conflict with garbage receipts. Provided training to chief officer on proper record keeping in accordance with garbage management plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2008
Resolution: PSCO gave verbal training while on board vessel.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 13 October 2004 Resolved
14 RATIONS MISSING FROM STBD LIFEBOAT. PROVIDE PROOF OF REPLACEMENTS PRIOR TO DEPARTURE FROM COTP BALTIMORE SOLAS 74(A) III/ 46.12.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2004
Resolved 15 October 2004
Resolution: Received invoice for the above mentioned item.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 October 2004 Resolved
REPLACE MISSING TIDE TABLES FOR ATLANTIC OCEAN. PROVIDE EVIDENCE PRIOR TO DEPARTURE FROM COTP BALTIMORE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2004
Resolved 15 October 2004
Resolution: Received invoice for the above mentioned item.
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 October 2004 Resolved
REPLACE OUT OF DATE BRITISH ADMIRALTY PUBLICATION NP 69 VOL II. PROVIDE EVIDENCE OF REPLACEMENT PRIOR TO DEPARTURE FROM COTP BALTIMORE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2004
Resolved 15 October 2004
Resolution: Received invoice for the above mentioned item.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.