← All vessels
SUNSHINE II
Freight Ship · Ro-Ro Cargo Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named SUNSHINE II
SUNSHINE II is a 1987 freight ship. The Coast Guard has recorded 33 inspections since 1997, most recently in February 2004, along with 39 deficiencies and 2 operational controls.
Records from 1997 to 2004. Most recent: inspection, 29 February 2004.
- Built
- 1987
- Last inspected
- 29 February 2004
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 39 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8420426 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3QU7
462862
Flag
CYPRUS
—
Maury page id
psix-462862
Inspections, by type
…with no type recorded22
Years with a record
8 calendar years (1997–2004)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it2128 - Convention (Subpart B), Net Ton
7095 - Convention (Subpart B), Gross Ton
4080 - Dead Weight, Ton
7095 - Convention (Subpart B), Gross Ton
4080 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
29 February 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2015250
22 February 2004
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2008413
19 February 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2008961
15 February 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2006873
24 October 2003
MARPOL Annex I Examination · Re-Inspection · Ballast Water Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1932669
24 August 2003
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1875824
6 June 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1811326
19 March 2003
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1756892
11 February 2003
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1741431
10 July 2002
MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1643840
30 April 2002
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1610148
12 April 2002
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1604088
23 October 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 294971
2 October 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 294311
12 September 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 210728
12 September 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 768342
10 April 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 288889
17 October 2000
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 282973
3 October 2000
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 282707
1 May 2000
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 277444
18 April 2000
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 276912
12 April 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 816502
29 September 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 433398
21 September 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1337227
15 September 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1119879
21 July 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 431522
21 October 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 421771
9 September 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 420301
6 July 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 417667
30 May 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 417015
16 May 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 415863
11 October 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 408704
8 September 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 407660
Deficiency record · 39
Engineering › Fuel Oil Storage/Transfer System
Issued 22 February 2004
Resolved
Vessel unable to provide evidence of last required static liquid pressure test of its bunkering line in accordance with 33 CFR 156.170 (c)(4). Vessel to conduct test of bunkering line and attest to results in writing by Chief Engineer and Master. LEGACY COMPONENT DESC: Piping
Fire Fighting › Portable Foam Applicators
Issued 11 February 2003
Resolved
Provide missing Foam Fire Extinguisher in the Emergency Generator Compartment.
Navigation › Piloting/Steering
Issued 11 February 2003
Resolved
Provide current British Admiralty Tide Table and Current Tidal Table. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Documentation › Certificates/Documents
Issued 7 February 2003
Resolved
Vessel unable to provide proof of a valid certificate of responsibility. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Lifesaving
Issued 2 October 2001
Resolved
Stencil all lifebuoys with vessel specific information
Engineering
Issued 2 October 2001
Resolved
Prove proper operation of the OWS to the satisfaction of class
Fire Fighting
Issued 2 October 2001
Resolved
Install an automatic closure device for the A/60 to the main stair tower onthe 01 deck port side
Fire Fighting
Issued 2 October 2001
Resolved
Remove all door stops from A/60 boundary doors to the main stair well
Engineering
Issued 2 October 2001
Resolved
Re-install the #2 lube oil purifier to the satisfaction of class
Unknown
Issued 2 October 2001
Resolved
Remove all paint and oils from the steering gear flat
Navigation
Issued 2 October 2001
Resolved
Make proper repairs to the packing stock gland to the satisfaction of class
Unknown
Issued 2 October 2001
Resolved
Ensure that the running water to the hospital space is adequate/running
Engineering
Issued 2 October 2001
Resolved
Make proper repairs to the piping arrangement for the #1 lube oil purifier to the satisfaction of class
Documentation
Issued 2 October 2001
Resolved
Prove acceptance of officers licenses from flag.
Unknown
Issued 2 October 2001
Resolved
Remove all waste rags from main space and dispose properly
Unknown
Issued 2 October 2001
Resolved
Remove all expired medicine from medical locker and provide vessel with full compliment of meds.
Navigation
Issued 3 October 2000
Resolved
Provide effective speed at which bow thruster is used in maneuvering vesseli.a.w. 33CFR164.35(g)(5).
Documentation
Issued 3 October 2000
Resolved
Post watch schedule and provide evidence of compliance of STCW 95 VIII/1_x001C_ from vessel's owner._x001C_
Navigation
Issued 18 April 2000
Resolved
Remove excess oil from under steering gear.
Fire Fighting
Issued 9 September 1998
Resolved
INSTALL SELF CLOSING DEVICE TO FIRE DOOR INTO MACHINERY SPACE AS PER SOLAS '74 ('81 AMMENDMENTS) CHAPTER 2-II/REG 47.1
Documentation
Issued 16 May 1998
Resolved
PROVIDE ON BOARD CURRENT TIDE TABLES. CORRECT PRIOR TO NEXT U.S. PORT.
Documentation
Issued 16 May 1998
Resolved
PROVIDE STCW ENDORSEMENT FOR THE 2ND OFFICER'S LICENSE. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Lifesaving
Issued 16 May 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 16 May 1998
Resolved
PROVIDE ON BOARD CURRENT U.S. NAVIGATIONAL RULES. CORRECT PRIOR TO NEXT U.S. PORT.
Lifesaving
Issued 16 May 1998
Resolved
REPLACE SELF IGNITING/SMOKE LIGHTS ON BRIDGE WINGS LIFEBOUYS. CORRECT PRIORTO DEPARTURE.
Lifesaving
Issued 16 May 1998
Resolved
REPLACE ENGINE BELT FOR MOTOR LIFEBOAT AND CONDUCT OPERATION TO THE SATISFACTION OF CLASS SOCIETY. PROVIDE OCMI WITH CLASS REPORT. ITEM MUST BECORRECTED PRIOR TO DEPARTURE.
Navigation
Issued 16 May 1998
Resolved
ELIMINATE EXCESSIVE HUNTING IN STEERING GEAR. CORRECT PRIOR TO COMPLIANCE DATE. PROVIDE OCMI WITH CLASS SURVEYOR'S REPORT PRIOR TO NEXT U.S. PORT.
Construction/Loadline
Issued 16 May 1998
Resolved
MARK LOADLINE IN CONTRASTING COLOR TO THE SHIP'S HULL. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Documentation
Issued 16 May 1998
Resolved
PROVIDE ON BOARD CURRENT LIGHT LIST WITH CORRECTIONS. CORRECT PRIOR TO NEXTU.S. WATERS.
Fire Fighting
Issued 16 May 1998
Resolved
MAKE FIRE STATION PORT SIDE ON MAIN DECK READILY ACCESSIBLE. CORRECT PRIOR TO DEPARTURE.
Accommodation/Occupational Safety
Issued 8 September 1997
Resolved
Lock discharge overboard valve for black water (sewage).
Fire Fighting
Issued 8 September 1997
Resolved
Remove holdbacks from fire screen doors.
Navigation
Issued 8 September 1997
Resolved
Provide double nuts, cotter nuts or locking nuts for all steering bolts.
Engineering
Issued 8 September 1997
Resolved
Prove proper operation of oily water seperator.
Electrical
Issued 8 September 1997
Resolved
Remove loose batteries in Emergency Generator Room.
Engineering
Issued 8 September 1997
Resolved
Prove proper operation of emergency phone system.
Fire Fighting
Issued 8 September 1997
Resolved
Provide key box for fire stations or remove locks.
Lifesaving
Issued 8 September 1997
Resolved
Repair lifering light port side by life boat.
Construction/Loadline
Issued 8 September 1997
Resolved
Provide pollution placard (U.S.).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.