MAURY USCG vessel records Sign in
← All vessels

SUNSHINE II

SUNSHINE II is a 1987 freight ship. The Coast Guard has recorded 33 inspections since 1997, most recently in February 2004, along with 39 deficiencies and 2 operational controls.

Records from 1997 to 2004. Most recent: inspection, 29 February 2004.

Built
1987
Last inspected
29 February 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8420426 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
462862
Flag
CYPRUS
—
Maury page id
psix-462862

Inspections, by type

…with no type recorded22
Years with a record 8 calendar years (1997–2004)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it2128 - Convention (Subpart B), Net Ton
7095 - Convention (Subpart B), Gross Ton
4080 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

29 February 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2015250
22 February 2004 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2008413
19 February 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2008961
15 February 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2006873
24 October 2003 MARPOL Annex I Examination · Re-Inspection · Ballast Water Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1932669
24 August 2003 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1875824
6 June 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1811326
19 March 2003 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1756892
11 February 2003 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1741431
10 July 2002 MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1643840
30 April 2002 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1610148
12 April 2002 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1604088
23 October 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 294971
2 October 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 294311
12 September 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 210728
12 September 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 768342
10 April 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 288889
17 October 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 282973
3 October 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 282707
1 May 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 277444
18 April 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 276912
12 April 2000 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 816502
29 September 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 433398
21 September 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1337227
15 September 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1119879
21 July 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 431522
21 October 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 421771
9 September 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 420301
6 July 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 417667
30 May 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 417015
16 May 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 415863
11 October 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 408704
8 September 1997 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 407660

Deficiency record · 39

Engineering › Fuel Oil Storage/Transfer System
Issued 22 February 2004 Resolved
Vessel unable to provide evidence of last required static liquid pressure test of its bunkering line in accordance with 33 CFR 156.170 (c)(4). Vessel to conduct test of bunkering line and attest to results in writing by Chief Engineer and Master. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 22 February 2004
Resolved 24 February 2004
Resolution: Received Master''s statement attesting to the static liquid testing of bunkering line. System was tested to 4.5 bars, according to Vessel''s Chief Engineer.
Fire Fighting › Portable Foam Applicators
Issued 11 February 2003 Resolved
Provide missing Foam Fire Extinguisher in the Emergency Generator Compartment.
Due 10 March 2003
Resolved 20 March 2003
Resolution: Vessel provided Foam Fire Extinguisher in the Emergency Generator Compartment.
Navigation › Piloting/Steering
Issued 11 February 2003 Resolved
Provide current British Admiralty Tide Table and Current Tidal Table. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Improper Installation
Due 10 March 2003
Resolved 20 March 2003
Resolution: Vessel provided tide/ current table
Documentation › Certificates/Documents
Issued 7 February 2003 Resolved
Vessel unable to provide proof of a valid certificate of responsibility. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2003
Resolution: Received via fax a letter dated 12 February 2003, from Pearlbay Shipping Co. Limited stateting that they remain with fully responsability of the vessel under the terms and conditions of the COFR.
Lifesaving
Issued 2 October 2001 Resolved
Stencil all lifebuoys with vessel specific information
Condition: Unknown
Due 10 October 2001
Resolved 24 October 2001
Engineering
Issued 2 October 2001 Resolved
Prove proper operation of the OWS to the satisfaction of class
Condition: Unknown
Due 2 November 2001
Resolved 24 October 2001
Fire Fighting
Issued 2 October 2001 Resolved
Install an automatic closure device for the A/60 to the main stair tower onthe 01 deck port side
Condition: Unknown
Due 10 October 2001
Resolved 24 October 2001
Fire Fighting
Issued 2 October 2001 Resolved
Remove all door stops from A/60 boundary doors to the main stair well
Condition: Unknown
Due 10 October 2001
Resolved 24 October 2001
Engineering
Issued 2 October 2001 Resolved
Re-install the #2 lube oil purifier to the satisfaction of class
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Unknown
Issued 2 October 2001 Resolved
Remove all paint and oils from the steering gear flat
Condition: Unknown
Due 10 October 2001
Resolved 24 October 2001
Navigation
Issued 2 October 2001 Resolved
Make proper repairs to the packing stock gland to the satisfaction of class
Condition: Unknown
Due 30 April 2002
Resolved 30 April 2002
Resolution: corrected, via class report
Unknown
Issued 2 October 2001 Resolved
Ensure that the running water to the hospital space is adequate/running
Condition: Unknown
Due 10 October 2001
Resolved 24 October 2001
Engineering
Issued 2 October 2001 Resolved
Make proper repairs to the piping arrangement for the #1 lube oil purifier to the satisfaction of class
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Documentation
Issued 2 October 2001 Resolved
Prove acceptance of officers licenses from flag.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Unknown
Issued 2 October 2001 Resolved
Remove all waste rags from main space and dispose properly
Condition: Unknown
Due 10 October 2001
Resolved 24 October 2001
Unknown
Issued 2 October 2001 Resolved
Remove all expired medicine from medical locker and provide vessel with full compliment of meds.
Condition: Unknown
Due 10 October 2001
Resolved 24 October 2001
Navigation
Issued 3 October 2000 Resolved
Provide effective speed at which bow thruster is used in maneuvering vesseli.a.w. 33CFR164.35(g)(5).
Condition: Unknown
Due 10 October 2000
Resolved 17 October 2000
Documentation
Issued 3 October 2000 Resolved
Post watch schedule and provide evidence of compliance of STCW 95 VIII/1_x001C_ from vessel's owner._x001C_
Condition: Unknown
Due 9 November 2000
Resolved 9 November 2000
Navigation
Issued 18 April 2000 Resolved
Remove excess oil from under steering gear.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Fire Fighting
Issued 9 September 1998 Resolved
INSTALL SELF CLOSING DEVICE TO FIRE DOOR INTO MACHINERY SPACE AS PER SOLAS '74 ('81 AMMENDMENTS) CHAPTER 2-II/REG 47.1
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Documentation
Issued 16 May 1998 Resolved
PROVIDE ON BOARD CURRENT TIDE TABLES. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 7 July 1998
Resolved 6 July 1998
Documentation
Issued 16 May 1998 Resolved
PROVIDE STCW ENDORSEMENT FOR THE 2ND OFFICER'S LICENSE. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 7 July 1998
Resolved 6 July 1998
Lifesaving
Issued 16 May 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 May 1998
Resolved 19 May 1998
Documentation
Issued 16 May 1998 Resolved
PROVIDE ON BOARD CURRENT U.S. NAVIGATIONAL RULES. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 16 May 1998
Resolved 19 May 1998
Lifesaving
Issued 16 May 1998 Resolved
REPLACE SELF IGNITING/SMOKE LIGHTS ON BRIDGE WINGS LIFEBOUYS. CORRECT PRIORTO DEPARTURE.
Condition: Unknown
Due 16 May 1998
Resolved 19 May 1998
Lifesaving
Issued 16 May 1998 Resolved
REPLACE ENGINE BELT FOR MOTOR LIFEBOAT AND CONDUCT OPERATION TO THE SATISFACTION OF CLASS SOCIETY. PROVIDE OCMI WITH CLASS REPORT. ITEM MUST BECORRECTED PRIOR TO DEPARTURE.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Navigation
Issued 16 May 1998 Resolved
ELIMINATE EXCESSIVE HUNTING IN STEERING GEAR. CORRECT PRIOR TO COMPLIANCE DATE. PROVIDE OCMI WITH CLASS SURVEYOR'S REPORT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Construction/Loadline
Issued 16 May 1998 Resolved
MARK LOADLINE IN CONTRASTING COLOR TO THE SHIP'S HULL. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Documentation
Issued 16 May 1998 Resolved
PROVIDE ON BOARD CURRENT LIGHT LIST WITH CORRECTIONS. CORRECT PRIOR TO NEXTU.S. WATERS.
Condition: Unknown
Due 7 July 1998
Resolved 6 July 1998
Fire Fighting
Issued 16 May 1998 Resolved
MAKE FIRE STATION PORT SIDE ON MAIN DECK READILY ACCESSIBLE. CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Accommodation/Occupational Safety
Issued 8 September 1997 Resolved
Lock discharge overboard valve for black water (sewage).
Condition: Unknown
Due 21 September 1997
Resolved 22 September 1997
Fire Fighting
Issued 8 September 1997 Resolved
Remove holdbacks from fire screen doors.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Navigation
Issued 8 September 1997 Resolved
Provide double nuts, cotter nuts or locking nuts for all steering bolts.
Condition: Unknown
Due 21 September 1997
Resolved 22 September 1997
Engineering
Issued 8 September 1997 Resolved
Prove proper operation of oily water seperator.
Condition: Unknown
Due 21 September 1997
Resolved 22 September 1997
Electrical
Issued 8 September 1997 Resolved
Remove loose batteries in Emergency Generator Room.
Condition: Unknown
Due 22 September 1997
Resolved 22 September 1997
Engineering
Issued 8 September 1997 Resolved
Prove proper operation of emergency phone system.
Condition: Unknown
Due 21 September 1997
Resolved 22 September 1997
Fire Fighting
Issued 8 September 1997 Resolved
Provide key box for fire stations or remove locks.
Condition: Unknown
Due 21 September 1997
Resolved 22 September 1997
Lifesaving
Issued 8 September 1997 Resolved
Repair lifering light port side by life boat.
Condition: Unknown
Due 21 September 1997
Resolved 22 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
Provide pollution placard (U.S.).
Condition: Unknown
Due 21 September 1997
Resolved 22 September 1997

Ownership record