NIKKEI TIGER is a 1997 freight ship. The Coast Guard has recorded 20 inspections since 1998, most recently in February 2012, along with 5 deficiencies and 2 operational controls.

Records from 1998 to 2012. Most recent: operational control imposed, 25 February 2012.

Built
1997
Last inspected
19 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9159438 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
462906
Flag
PANAMA
—
Maury page id
psix-462906

Inspections, by type

…with no type recorded9
Years with a record 11 calendar years (1998–2012)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it25074 - Convention (Subpart B), Gross Ton
15145 - Convention (Subpart B), Net Ton
45363 - Dead Weight, Ton
52357 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

19 February 2012 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4247249
1 July 2009 MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex VI Survey · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3513969
29 August 2008 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3315773
6 June 2008 MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3223058
22 February 2008 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3151957
8 May 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2925049
7 May 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2923934
4 April 2006 Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2616204
30 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2323512
28 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2321900
18 September 2004 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2198428
9 June 2004 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2093616
29 November 2002 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1710705
26 November 2002 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1711328
15 August 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 292909
7 March 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 62293
14 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 287172
14 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 287592
2 November 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 434487
28 July 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 418572

Deficiency record · 5

Navigation › Collision/Grounding Avoidance › Radar
Issued 19 February 2012 Resolved
The Radar was reported not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2012
Resolved 28 February 2012
Resolution: 28Feb12: Received a tech report. The report stated the radar was repaired, tested and found operating satisfactory. Cleared deficiency and COTP Order 0229-12.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 1 July 2009 Resolved
Decanting valves on the heavy fuel oil settling and service tanks had override devices installed on them.
Action required: 705 - Other - as specified
Due 1 July 2009
Resolved 1 July 2009
Resolution: Corrected on the spot.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 6 June 2008 Resolved
During the inspection of the vessels records the PSCO found that the vessel had conducted the test of the bunkering lines on June 2008 however the test was conducted using air as the test medium. Vessel is prohibited from bunkering operations in US waters until a hydrostatic test is conducted to the bunker lines.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 29 August 2008
Resolution: Vessel conducted and logged satisfactory pressure test of bunkering lines.
Deck/Cargo › Cargo Stowage › General
Issued 4 April 2006 Resolved
Vessels starboard loadline was submerged due to inaccurate clinometers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2006
Resolution: Shore technician was employed to overhaul the ships clinometers, class tested clinometers and found to be operating satisfactory.
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 29 November 2002 Resolved
Commence conducting tests per 33 CFR 164.25 and make entries in bridge log prior to entering or departing US ports.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2002
Resolution: Crew acknowleged procedures required for arrival and departure tests and insured compliance prior to departure.

Ownership record