KITE

KITE is a 1997 freight ship. The Coast Guard has recorded 20 inspections since 1998, most recently in July 2009, along with 16 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 1998 to 2009. Most recent: inspection, 12 July 2009.

Built
1997
Last inspected
12 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9122291 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
462975
Flag
MARSHALL ISLANDS
—
Maury page id
psix-462975

Inspections, by type

…with no type recorded10
…past their stated due date1
Years with a record 9 calendar years (1998–2009)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it27681 - Convention (Subpart B), Gross Ton
15727 - Convention (Subpart B), Net Ton
47195 - Dead Weight, Ton
55885 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

12 July 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3532214
9 July 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3529465
14 April 2009 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex VI Survey · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3446411
26 September 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3332955
14 March 2008 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3164118
26 February 2008 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3152222
25 February 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3153554
23 February 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3152340
24 April 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2914346
20 February 2007 PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2874431
23 January 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2571585
28 December 2004 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2265447
27 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2265181
21 June 2004 PII Safety Exam · MTSA/ISPS Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2105834
10 April 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1771654
7 April 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1769871
3 April 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1767427
19 July 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 291973
23 October 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 283094
2 August 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 418884

Deficiency record · 16

Navigation › Collision/Grounding Avoidance › Radar
Issued 12 July 2009 Resolved
The radar was reported not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2009
Resolved 12 July 2009
Resolution: Received, reviewed and accepted tech report from [name withheld] stating the radar was repaired, tested found satisfactory.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 14 April 2009 Resolved
Heavy/steady water leak on #2 Fire/Ballast Pump.
Action required: 705 - Other - as specified
Due 21 April 2009
Resolved 16 April 2009
Resolution: Received proper documentation from vessel master clearing deficiency. See narrative for details.
Construction/Loadline › Structures › Door
Issued 14 March 2008 Resolved
Emergency escape from steering gear space containing emergency fire pump is locked from inside, not allowing access from the main deck (secondary means of access to emergency fire pump). SOLAS Ch II-2 Reg 10.2.2.3.2.2 To the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 May 2008
Resolution: Recieved class report. Deficiency rectified
Engineering › Freshwater System (air cooling) › Hose
Issued 20 February 2007 Resolved
The air cooling tank drain had been modified with a rubber hose connecting to the air cooling drain tank transporting oil from an oil filled tank to a water filled tank. SOLAS 74 am II-1/26.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2007
Resolution: Class reports that the rubber hose has been removed.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 20 February 2007 Resolved
Top bracing for main engine is wired in place. Bracing should be secured with a robust pin or other means. Deficiency should be corrected prior to departure from port to the satisfaction of Class. SOLAS 74 am II-1/26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2007
Resolution: Class reports putting a condition of class upon the vessel to have deficiency rectified by 22 May 2007.
Fire Fighting › Fire Main › Condition
Issued 20 February 2007 Resolved
Fire Main on starboard side on main deck is patched in 14 places. Vessel is to have Class inspect repairs prior to departure. SOLAS 74 am II-2/4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2007
Resolution: Class reports that the "Straub Couplings" have been used on the fire main and are an approved patch for main fire line.
Lifesaving › Launching Appliances › Block
Issued 20 February 2007 Resolved
The sheaves on the starboard lifeboat davits did not turn properly when lifeboat is lowered/raised. Deficiency is to be repaired to the satisfaction of Class. Class should also test the portside lifeboat launching appliance for similar problems. SOLAS 74 am III/19.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2007
Resolution: Class reports that all sheaves on both lifeboats are working properly.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 20 February 2007 Resolved
Patches were found on the grey water line on the stbd side before the valve, on shaft reading cooling line, suction line from bilge tank, and fresh water drain line on port side located in steering. No tech reports had filled out and no evidence of company notification. Request Class to inspect repairs and cement patches on aux cw pump and general service pump prior to departure. SOLAS 74 IX/3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2007
Resolution: Class reports that all patches are approved for temporary repairs only. Confirms there was no company notification.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 February 2007 Resolved
Lifejackets in fwd bosun store room are obstructed by stores and not easily accessible. Lifejackets provided are not of the appropriate type. Obstructions shall be removed and proper lifejackets installed prior to next US port after sailing foreign. SOLAS 74 am III/7.2.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 February 2007
Resolution: Class reports obstructions blocking access to safety equipment have been removed and 6 proper lifejackets have been installed in fwd bosun stores.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 20 February 2007 Resolved
Paint Locker Sprinkler valve is obstructed by drum and other stored items in bosun stores. Obstructions must be removed prior to next US port after sailing foreign to the satisfaction of Class. SOLAS 74 am II-2/21.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 February 2007
Resolution: Class reports that items blocking access to safety equipment have been removed.
Operations/Management › Ballast Water Managment › Training
Issued 20 February 2007 Resolved
Ballast water management and reporting training is not being conducted as required. Current vessel reporting procedures only include reporting 12 tanks, not the 13 tanks the vessel is equipped with and plan specifies. Training, plan review and reporting amendments are to be made prior to next US port after sailing foreign to the satisfaction of Class. 33 CFR 151.2035
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2007
Resolution: Received satisfactory classification society audit report.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 20 February 2007 Resolved
Ship's safety and training record book instructions (5.2.9) are not being followed. Master is directed to sign on the first of every month and has not been signing the record book. Deficiencies are to be rectified prior to next US port after sailing foreign to the satisfaction of Class. SOLAS 74 am IX/5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2007
Resolution: Received satisfactory classification society audit report.
Operations/Management › Drills/Instruction › Fire
Issued 20 February 2007 Resolved
Crew failed first fire drill. Crew went into "smoke" filled space without protective equipment. Team donned fire suits immediately outside of simulated fire space. Fire teams should have arrived on scene in protective gear ready to fight fires.
Action required: 705 - Other - as specified
Due 20 February 2007
Resolved 20 February 2007
Resolution: Master and C/O were counseled by attending CG inspectors with better methods. Drills were run a second time with much improvement.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 20 February 2007 No resolution recorded
SOLAS Training Manual is not ship specific. Manual must be updated to reflect accurate ship equipment to avoid confusion. Deficiency is to be rectified prior to next US port after sailing foreign. SOLAS 74 am III/18.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 February 2007 — due date passed with no resolution recorded
Resolution: Received satisfactory classification society audit report.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 21 June 2004 Resolved
Second Officer, Third Officer and Chief Engineer do not have proper flag state endorsements to thier national certificate of competence required by STCW 95 1/14-1.1. Provide U.S. Coast Guard copies of flag issued receipt of proper application for endorsement attesting recognition of national certificate for all parties named above.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2004
Resolution: Received faxed Flag State receipt of license acknowledgements dated 17Jun04 for three members noted.
Construction/Loadline
Issued 23 October 2000 Resolved
Loadline/Plimsol mark not painted a contrasting color. Excessive rust_x001C_ from shipboard operations has obscured the original paint. (ILLC 1966, Reg #8)
Condition: Unknown
Due 9 January 2001
Resolved 9 January 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.