CLEARWATER

CLEARWATER is a 1969 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in June 2026, along with 21 deficiencies and 6 casualty investigations between 2005 and 2025.

Records from 2005 to 2026. Most recent: inspection, 29 June 2026.

Built
1969
Last inspected
29 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 June 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL2001
Flag
UNITED STATES
Maury page id
psix-46300

Documentation record

Registered dimensions (L × B × D)76.0 ft × 24.3 ft × 7.2 ft
Registered tonnagegross 69 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHARVEY F. GAMAGE SHIPBLDE · SOUTH BRISTOL, ME, UNITED STATES · built 1969
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSOUTH BRISTOL, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

29 June 2026 Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8418592
19 March 2026 Annual Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8315362
2 October 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8245723
2 October 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8248665
24 July 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8194017
6 June 2025 Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8153883
11 April 2024 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7897550
14 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7824381
28 June 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7723550
8 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7692208
28 June 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7489448
17 June 2022 Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7465257
29 July 2021 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7272938
5 May 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6949291
14 November 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7306471
31 July 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6768758
27 September 2018 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6550169
12 September 2018 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6539500
31 July 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6496942
13 November 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6305283
1 May 2017 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6136133
12 September 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5999896
11 July 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5936520

Deficiency record · 21

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2025 Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements. Vessel actively taking on water from running aground on 04JUN25. Prior to movement, vessel must submit repair plan. 46 CFR 185.315(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2025
Resolution: Vessel repaired satisfactorily
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 11 April 2024 Resolved
SUITABLE COVERS, GUARDS...SHALL BE INSTALLED IN WAY OF ALL EXPOSED AND HAZARDOUS PLACES SUCH AS GEARS, MACHINERY, ETC. PROVIDE SUITABLE COVER / GUARD FOR ALTERNATOR & BELT. 46CFR177.35-15 (OLD-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2024
Resolution: O/O PROVIDED EVIDENCE OF SUITABLE ALTERNATOR GUARD INSTALLED IN PLACE.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 April 2024 Resolved
MACHINERY & FUEL TANK SPACES SHALL BE SEPARATED FROM ACCOMODATION SPACES BY WATERTIGHT AND/OR VAPOR TIGHT BULKHEADS...PROVIDE APPROPRIATE SEALING TO ENGINE ROOM WIRE PENETRATIONS. 46CFR182.35-1 (OLD-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2024 Resolved
SWITCHBOARDS SHALL BE ADEQUATELY PROTECTED AND PROVISION SHALL BE MADE FOR ACCESS THERETO (<50v)... ALL ELECTRICAL EQUIPMENT [>50v] INCLUDING CONTROLLERS, DISTRIBUTION PANELS, ETC. SHALL BE DRIPPROOF PROTECTED. PROVIDE SUITABLE COVERING TO ON-DECK SSDG BREAKER PANEL. 46CFR183.05-15 / 183.10-10 (OLD-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2023 Resolved
Ring Life Buoy must be of an approved type, constructed in accordance with subpart 160.050 of this chapter and maintained in serviceable condition. Ring buoy grab lines were not the correct line nor installed correctly as the anchor points were not factory complete. Renew starboard ring life buoy, mark vessel name as appropriate and ensure retro tape is affixed. Renew floating watertight lanyard and ensure proper length (3-6 ft).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2023
Resolved 12 July 2023
Resolution: Complete
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2023 Resolved
Ring buoy shall have a line attached to it at least 60 ft. in length. Port forward ring buoy line is wasted worn. Renew as appropriate with minimum required length.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2023
Resolved 12 July 2023
Resolution: New line attached
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2023 Resolved
Vessel shall have a fire nozzle approved by the Commandant in accordance with 162.027-6 of this chapter. forward fire station nozzle has an improper repair that impairs it's ease of use. Renew as appropriate. Aft Fire station has a compromised gasket impairing it's full spray capability. Renew gasket as appropriate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 12 July 2023
Resolution: Gasket renewed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 July 2021 Resolved
PFD's had worn/discolored retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2021
Resolved 12 August 2021
Resolution: Operator sent pictures/receipts verifying new pfds.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2021 Resolved
Life ring located amidships is worn/damaged.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2021
Resolved 27 August 2021
Resolution: Vessel sent photograph of new life ring.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 July 2021 Resolved
Pressure gauge on fire pump was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2021
Resolved 16 August 2021
Resolution: Operator sent a video of the newly installed pressure gauge showing 60psi while running the fire pump.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 July 2021 Resolved
Instructions for operation of fixed fire extinguishing system must have complete operation to release agent into the space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2021
Resolved 12 August 2021
Resolution: Operator sent pictures of updated instructions in galley and outside engineering space.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 July 2021 Resolved
Vessel charts on board not up to date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2021
Resolved 12 August 2021
Resolution: Operator sent pictures of new charts with latest update July 2021.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 July 2021 Resolved
Backstay deck connection bolts for topmast on port and starboard side were not long enough to ensure proper threading.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2021
Resolved 12 August 2021
Resolution: Operator sent pictures of new connection bolts that are fully threaded.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 31 July 2019 Resolved
A VESSEL SHALL HAVE VALID FCC SHIP STATION CERTIFICATE, RADIO TELEPHONY CERTIFICATE, AND BRIDGE TO BRIDGE CERTIFICATE. ALL OF THE VESSELS FCC CERTIFICATES WERE EXPIRED. 47CFR80.13
Action required: 705 - Other - as specified
Due 7 August 2019
Resolved 8 August 2019
Resolution: RECEIVED COPIES OF THE NEWLY ISSUED CERTIFICATES.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2019 Resolved
EACH FLOATING WATERLIGHT MUST HAVE A LANYARD OF 3-FEET IN LENGTH, WRAPPED AROUND THE BODY OF THE RING LIFE BUOY, AND ATTACHED TO THE LIGHT WITH A CORROSION RESISTANT CLIP. 46CFR180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2019
Resolution: RECEIVED PHOTOS OF NEW LANYARD AND CLIP.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 31 July 2019 Resolved
EACH DISPOSABLE HYDROSTATIC RELEASE UNIT MUST BE MARKED WITH AN EXPIRATION DATE OF TWO YEARS AFTER INSTALLATION. THE HYDROSTATIC RELEASE FOR THE IBA WAS MARKED WITH APRIL 2019. 46CFR185.740(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2019
Resolution: RECEIVED PHOTOS OF THE NEW HRU RECEIPT, OLD/NEW HRU NEXT TO EACH OTHER, AND NEW HRU INSTALLED.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 31 July 2019 Resolved
PROVIDE PURCHASE AND INSTALLATION DATES FOR ALL RIGGING KEY COMPONENTS LISTED IN APPENDIX (1) TO ENCLOSURE (1) OF NVIC 02-16. MAKE AVAILABLE A RIGGING PREVENTATIVE MAINTENANCE PROGRAM THAT PROVIDES A LEVEL OF DETAIL COMMENSURATE WITH APPENDIX (2) TO ENCLOSURE (1) OF NVIC 02-16 (RIGGING INVENTORY/PREVENTATIVE MAINTENANCE INSPECTION TEMPLATE (SAMPLE)) OR PROPOSE A MUTUALLY ACCEPTABLE THIRD PARTY TO SURVEY THE RIGGING AND PROVIDE A REPORT WITH A LEVEL OF DETAIL COMMENSURATE WITH EITHER APPENDIX (3) OR (4) TO ENCLOSURE (1) OF NVIC 02-16 (THIRD PARTY RIGGING SURVEY SAMPLES A & B).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2019
Resolved 17 September 2019
Resolution: Documentation received. Added to docs section.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2018 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter, or other standards specified by the Commandant. The vessels ring life buoy's are weathered and buoyancy is in question. Replace identified ring life buoy's.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 6 September 2018
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 July 2018 Resolved
Electrical equipment exposed to corrosive environments must be of suitable construction and corrosion resistant. Wires leading to high water alarms in all voids are open to the potentially moist environment where corrosion can grow. Properly install junction boxes to house wires going to all high water alarms.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 6 September 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 July 2018 Resolved
Provide purchase and installation dates for all rigging key components listed in Appendix (1) to Enclosure (1) of NVIC 02-16.
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 25 September 2018
Resolution: Operator submitted inventory of standing and running rigging, with as many installation dates as he could verify. Operator will update as maintenance occurs.
Engineering › Bilge Water Management System › Not Operational
Issued 11 July 2016 Resolved
Bilge alarm in Galley inop.
Action required: 705 - Other - as specified
Due 11 July 2016
Resolved 11 July 2016
Resolution: Vessel proved proper operation of galley bilge alarm.

Casualty record · 6

9 August 2005Routine · role: Involved in a Marine Casualty · activity 2458161
15 October 2012Routine · role: Involved in a Marine Casualty · activity 4471121
11 November 2013Routine · role: Involved in a Marine Casualty · activity 4752554
12 September 2016Routine · role: Involved in a Marine Casualty · activity 5999896
8 May 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7692208
2 October 2025Routine · role: Involved in a Marine Casualty · activity 8248665
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.