BOTTOM SCRATCHER

BOTTOM SCRATCHER is a 1969 passenger vessel (inspected). The Coast Guard has recorded 90 inspections since 1985, most recently in July 2025, along with 153 deficiencies and 3 casualty investigations between 2007 and 2014.

Records from 1985 to 2025. Most recent: inspection, 7 July 2025.

Built
1969
Last inspected
7 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ9293
Flag
UNITED STATES
366745560, 368024590 (licence lapsed)
Maury page id
psix-46310

Inspections, by type

…with no type recorded11
Years with a record 37 calendar years (1985–2025)
The 90 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.0 ft × 21.0 ft × 8.4 ft
Registered tonnagegross 71 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLACKMAN BOATWORKS · SAN DIEGO, CA, UNITED STATES · built 1969
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 6 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9293MMSI 368024590 · cancelled · voluntarily equipped · granted 27 February 2018, cancelled 4 September 2025
WCY2214MMSI 366745560 · cancelled · compulsorily equipped · granted 5 February 2008, cancelled 22 February 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 90

7 July 2025 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8130549
3 September 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7944571
5 June 2024 Administrative Inspection · Drydock Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7931814
27 April 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7888742
15 December 2023 In-Service Inspection · Special Consideration
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7827841
19 September 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7741664
11 April 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7660670
29 September 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7543719
18 September 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7553741
10 June 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613904
6 June 2022 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7461235
6 March 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7476601
5 March 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7411470
4 January 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7380505
12 July 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7253712
23 July 2020 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7007340
11 May 2020 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6951469
3 October 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6827819
22 July 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6743285
17 May 2018 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6411562
27 February 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6350617
13 December 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6322447
15 June 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5828462
8 June 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5828458
18 June 2014 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4846068
19 May 2014 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4862755
7 May 2014 Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4848927
27 March 2014 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4825181
23 March 2014 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4826170
6 June 2012 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4336024
1 July 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3521595
28 May 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3179335
21 May 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3179324
13 July 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2993658
27 June 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2952650
19 May 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3272575
6 September 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2764240
28 June 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2617222
21 June 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2693019
15 August 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2459370
16 May 2005 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2351018
24 October 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2247135
23 August 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2182199
17 June 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2101777
13 June 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1816609
3 July 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1640617
26 June 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1636236
29 January 2002 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1483922
23 May 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399693
24 May 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1361528
30 July 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1434913
19 May 1999 Re-Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369175
5 March 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1131856
30 January 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1125201
27 May 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 795776
29 May 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368249
29 May 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437254
8 May 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1431653
4 June 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 148184
10 May 1995 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 876591
10 May 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 903826
19 April 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 851800
16 April 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 97763
19 January 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1178317
10 May 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1169113
17 September 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1439432
12 May 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 835988
28 February 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 62407
12 August 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 955652
7 May 1992 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 950651
28 April 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 958375
23 May 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1214364
17 May 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1223899
10 May 1991 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 920727
26 April 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 924815
29 August 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1226054
23 July 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1225761
16 July 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 903116
8 June 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1218072
25 May 1990 Damage Survey · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 901752
11 May 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1233167
6 June 1989 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1197347
5 May 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1205967
3 June 1988 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1198701
4 May 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1037759
4 June 1987 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1310473
5 June 1986 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 993740
29 April 1986 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1000552
22 May 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1290615
3 May 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1287301

Deficiency record · 153

11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 September 2024 Resolved
Each buoyant apparatus must have a life line securely attached around the outside, festooned in bights no longer than 1 m (3 ft.), with a seine float in each bight, unless the line is of an inherently buoyant material and absorbs little or no water. The life line must be at least 10 mm (3/8 in.) diameter and have a breaking strength of at least 5400 N (1215 lb.). Vessel's installed buoyant apparatus' have worn and broken life lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2024
Resolved 16 September 2024
Resolution: Life lines renewed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 September 2024 Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air into a CO2 protected space. Vessel's engine room ventilation ducts along bulwarks do not have a means of closure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2024
Resolved 27 September 2024
Resolution: New engineroom ventilation covers provided.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 September 2024 Resolved
The following shall be verified by competent personnel at least annually using available documentation required in 4.4.2.14: (1) Check and test the carbon dioxide system for operation. (2)Check that there have been no changes to the size, type, and configuration of the hazard and system. Vessel did not have record of annual servicing for 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2024
Resolved 4 September 2024
Resolution: Received tech report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 September 2024 Resolved
Each natch exposed to the weather must be a watertight, except that the following hatches may be weather tight: 1) each hatch on a watertight trunk that extends at least 12 inches above the weather deck. Vessels hatch opening to lazarette is not watertight. Provide repair proposal to meet CFR requirements for hatch openings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2024
Resolved 16 September 2024
Resolution: Hatch made water tight.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 September 2024 Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free. Vessel had Starlink antenna mounted to survival craft stowage piping which prevented a float free arrangement.
Action required: 10 - Deficiency Rectified
Due 3 September 2024
Resolved 3 September 2024
Resolution: Antenna removed during the course of the inspection. Deficiency entered for documentation purposes only.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 September 2023 Resolved
A fixed gas fire extinguishing system, which is capable of automatic discharge upon heat detection, may only be installed in a normally unoccupied space. Installed fixed gas extinguishing system in engine room not capable of automatic discharge upon heat detection as designed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 September 2023
Resolution: MI verified verified fixed extinguishing system now capable of automatic discharge.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 September 2023 Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Vessel life float does not have a placard stating approval under 160.027.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 26 September 2023
Resolution: MI verified life floats in serviceable condition.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 19 September 2023 Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with padlocking the seacock in the closed position. MI observed sea cock not properly secured/locked.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 21 September 2023
Resolution: MI verified vessel overboard valve now locked.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 September 2023 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Hole in engine room watertight bulkhead contains wiring that is not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 21 September 2023
Resolution: MI attested to proper rectification of bulkhead penetrations.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 September 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR." Forward escape hatch from berthing area not marked on both sides.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 21 September 2023
Resolution: MI attested to proper signage.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 June 2022 Resolved
During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. During examination, rot was found throughout engine room. Provide repair proposal to include scraping, treating and/or replacement of effected areas. Upon approval of proposal complete repairs to the satisfaction of the attending USCG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2022
Resolved 29 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2021 Resolved
46 CFR 180.71 (e) "Each life jacket carried on board the vessel must be marked in accordance with § 185.604 of this chapter." MI identified 10 adult life jackets in need of new reflective material
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 6 June 2022
Resolution: Owner placed new reflected tape on 10 life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 July 2021 Resolved
46 CFR 180.68: Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry - (1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, and (2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. [name withheld] missing flares.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 6 June 2022
Resolution: Vessel showed all required flares.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 July 2021 Resolved
46 CFR 185.606 Escape hatches and emergency exits. All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] id and required vsl owner to label emergency escape hatch with the lettering "Emergency Exit/Keep Clear".
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 4 January 2022
Resolution: Emergency escape hatch has been labeled with Emergency Exit sign.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 23 July 2020 Resolved
Make through hull valves available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2020
Resolution: Vessel made valves available.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 July 2020 Resolved
Remove combustible rubbish containers from accomodation spaces.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2020
Resolution: Vessel replaced rubbish containers with metal ones.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2020 Resolved
Engine room batteries have wing nuts connecting leads to the terminals. Vessel needs to remove wing nuts and provide permanent type of fastener.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 17 July 2020
Resolution: Removed wing nuts and installed permanent fastener (nut with nylon).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 July 2020 Resolved
Watertight bulkheads are not water or vapor tight. piping and cables passing through the bulkhead have air gaps around them. Air gaps around these cables and popping need to be sealed to provide water and vapor tight of that space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 29 July 2020
Resolution: All airgaps around cabbies and piping have been filled. Along with all other holes from old wiring and or removed hardware that penetrated the bulkhead to support brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 July 2020 Resolved
Life ring does not have adequate marking on it. Marking are faded and not visible. Provide vessel's name on life rings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 17 July 2020
Resolution: Vessel provided legible lettering stating vessel's name on the life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 15 July 2020 Resolved
Life rafts are missing person count and vessel's name. Vessel needs to provide correct markings person capacity for each life raft and provide the vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 17 July 2020
Resolution: Vessel proved and provided markings of passenger count and vessels name on its life rafts
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2020 Resolved
Due to COVID-19 circumstances beyond the control of the vessel, the vessel is unable to meet the time frame required by 46 CFR 176.600(c)(1). Vessel is allowed 90 days to continue operations in accordance with the COI, and is required to make itself available for inspection prior to 09AUG2020.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 August 2020
Resolved 15 July 2020
Resolution: Conducted COI renewal
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 May 2018 Resolved
Renew bow deck rails starting at super structure going forward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2018
Resolved 10 August 2020
Resolution: Vessel renewed and reinstalled bow rail.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2018 Resolved
Conduct post credit dry dock checkride.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2018
Resolved 5 August 2020
Resolution: Vessel conducted post drydock checkride.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 May 2018 Resolved
Provide current COD.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2018
Resolved 28 July 2020
Resolution: Vessel provided current COD.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 May 2018 Resolved
Conduct overdue annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2018
Resolved 28 July 2020
Resolution: Inspection conducted.
Lifesaving › Lifefloat › Painter
Issued 27 February 2018 Resolved
Painter not installed properly
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2018
Resolved 2 March 2018
Resolution: Installed properly
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 February 2018 Resolved
Not installed properly
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2018
Resolution: Installed properly
Engineering › Bilge Water Management System › Valve
Issued 27 February 2018 Resolved
Install one way non return valve on discharge hose
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2018
Resolution: Installed
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 December 2017 Resolved
Conduct Annual Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2018
Resolved 2 March 2018
Engineering › Bilge Water Management System › Pump
Issued 6 July 2016 Resolved
Provide line diagrams of bilge piping and pumping arrangement as well as all associated wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 3 August 2016
Resolution: Provided diagram of bilge pump central control system; approval letter uploaded.
Stability › Watertight Integrity › General
Issued 15 June 2016 Resolved
Prove operation of hull penetration shutoff valve for mask cleaning water pump suction in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 October 2016
Resolution: Replace valve with new operational valve.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 June 2016 Resolved
Install masthead light with proper arc of visibility.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Masthead light installed w/ proper arc of visibility.
Engineering › Bilge Water Management System › Pump
Issued 15 June 2016 Resolved
Install means to centrally control individual bilge pumps with visual indication
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Central control properly installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 June 2016 Resolved
Install UL listed boat or marine wiring in place of extension cord in aft bunk room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Proper marine wiring installed.
Engineering › Bilge Water Management System › Hose
Issued 15 June 2016 Resolved
Repair bilge discharge hoses in lazarette currently showing temporary duck tape patches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: New hose installed.
Engineering › Bilge Water Management System › Valve
Issued 15 June 2016 Resolved
Install shutoff valves on bilge hose discharge shell penetrations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Shutoffs installed in accessible locations.
Stability › Watertight Integrity › General
Issued 15 June 2016 Resolved
Remove and plug deck penetrations in lazarette overhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Penetration plugged.
Stability › Weathertight Integrity › General
Issued 15 June 2016 Resolved
Repair port lights in main cabin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 18 August 2016
Resolution: Port lights repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 June 2016 Resolved
Remove dead-end wires in lazarette and pilot house console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Dead-end wiring removed.
Documentation › Logs/Records › Logbook (official)
Issued 15 June 2016 Resolved
Provide proof of passenger count embark & disembark in ship's log.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Proper logs kept.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 15 June 2016 Resolved
Provide proof of NOAA EPIRB registration
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Registration proved.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 June 2016 Resolved
Provide proper storage of child size lifevests, segregated from adult size.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Life vest stowage in compliance.
Documentation › Markings/Placards › Lifejacket Placard
Issued 15 June 2016 Resolved
Provide donning instructions placard for all types of life vests used onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Placard displayed for all lifevest types.
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 June 2016 Resolved
Prove proper operation of compass light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Light installed.
Engineering › Fuel Oil Service System › Valve
Issued 15 June 2016 Resolved
Repair flame shielding for emergency fuel shut off valve handles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 October 2016
Resolution: Flame shielding repaired.
Engineering › Fuel Oil Service System › Valve
Issued 15 June 2016 Resolved
Prove proper operation of stbd middle and port forward fuel shut off valves remotely.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 October 2016
Resolution: Repaired reach Rods. All fuel shut-off valve work as designed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 June 2016 Resolved
Remove wire nuts and properly connect wires in engine room: port/outboard of port genset, bilge pump wires in fwd engine room and aft cabin, and in ceiling of engine room above port genset. No wire nuts to be used onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 October 2016
Resolution: All wire nuts were replaced throughout engine room and aft cabin.
Electrical › Electric Generation Source (service) › Switch
Issued 15 June 2016 Resolved
Prove gensets cannot simultaneously supply power to power panel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Toggle bar installed to ensure proper configuration of power supply.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 June 2016 Resolved
Install machinery guards on spinning belts on gensets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 October 2016
Resolution: Machinery guards were put in place.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 June 2016 Resolved
Make fwd bulkhead of engine room watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Fwd bulkhead made watertight.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 June 2016 Resolved
Install metallic penetrations with valves for hose penetration of forward bulkhead of engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Metallic valves installed at bkhd penetration.
Engineering › Bilge Water Management System › Interface Detector
Issued 15 June 2016 Resolved
Remove all oil and water from engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Water & oil removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 June 2016 Resolved
Repair light fixture housing in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 August 2016
Resolution: Light fixture repaired.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 June 2016 Resolved
Provide operational smoke detector in passenger compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Replaced w/ new detector.
Navigation › Piloting/Steering › Marine Charts
Issued 15 June 2016 Resolved
Provide updated charts onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: New charts provided onboard.
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 June 2016 Resolved
Provide current Coast Pilot onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Coast Pilot provided onboard.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 15 June 2016 Resolved
Provide current tide/current tables onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Current tide/current tables provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 June 2016 Resolved
Provide current light list onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Light list provided onboard.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 June 2016 Resolved
Replace dead batteries in 3 floating electric waterlights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Batteries replaced.
Lifesaving › Lifefloat › Serviceable
Issued 15 June 2016 Resolved
Remove excess unserviceable life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Unserviceable life float removed.
Lifesaving › Lifejacket/PFD (Type II) › Quantity
Issued 15 June 2016 Resolved
Remove or properly mark/segregate improper PFD types found aboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Improper PFD types removed.
Lifesaving › Lifefloat › Float Free
Issued 15 June 2016 Resolved
Life floats tethered to vessel in manner preventing automatic float-free. Tether between life floats too short. Painter clipped to life float grabline.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Short tether removed to all proper float free operation. Line between life floats lengthened. Painter spliced around life float body.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 15 June 2016 Resolved
Multiple lights inoperable on PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Lights replaced with new, fully charged lights.
Engineering › Bilge Water Management System › Pump
Issued 15 June 2016 Resolved
Rewire electric submerged pump system to provide centralized control of all required pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 18 August 2016
Resolution: Centralized control provided.
Construction/Loadline › Hull › Hull Plating
Issued 8 June 2016 Resolved
Remove and treat wood rot as marked in the anchor locker, port deck amidships, compressor room, engine room, and lazarette.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 7 July 2016
Stability › Intact Stability (when using lifting gear) › General
Issued 27 March 2014 Resolved
Prior to using your utility small boat, conduct a stability test and obtain a new stability letter.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 7 May 2014
Resolution: Witnessed satisfactory simplified stability test.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 March 2014 Resolved
Prior to using your utility small boat as a rescue boat, provide crew training and conduct drills to the satisfaction of an attending marine inspector.
Action required: 705 - Other - as specified
Due 14 April 2014
Resolved 4 April 2014
Resolution: Witnessed satisfactory MOB drill utilizing rescue boat.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 27 March 2014 Resolved
Prior to using your utility small boat as a rescue boat, provide emergency instructions that address the operation of the rescue boat to the satisfaction of an attending marine inspector.
Action required: 705 - Other - as specified
Due 14 April 2014
Resolved 4 April 2014
Resolution: Verified that vessel owner created emergency instructions that included use of the rescue boat.
Lifesaving › Rescue Boat › Construction
Issued 27 March 2014 Resolved
Prior to using your utility small boat as a rescue boat, demonstrate that the utility small boat meets the requirements to be a rescue boat to the satisfaction of an attending marine inspector.
Action required: 705 - Other - as specified
Due 14 April 2014
Resolved 4 April 2014
Resolution: Verified that rescue boat was in compliance with applicable regulations.
Personnel › Training › OUPV
Issued 27 March 2014 Resolved
Prior to operating your utility small boat with passengers for intended operations, or as a means to provide assistance during situations which are ordinarily anticipated or planned: provide a properly licensed operator and demonstrate that it meets the requirements for Uninspected Passenger Vessels in accordance with 46 CFR Subchapter C.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 9 July 2014
Resolution: Vessel has two licensed operaters for when operating as an UPV IAW 46 CFR Sub C.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 June 2012 Resolved
Provide batteries for waterlights on lifering buoys iaw 46CFR180.70.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 6 June 2012
Resolution: Item corrected on the spot.
Lifesaving › Lifefloat › Retroreflective Material
Issued 6 June 2012 Resolved
Apply new retroreflective tape on lifefloat iaw 46CFR180.200.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 6 June 2012
Resolution: Item corrected on the spot.
Lifesaving › Lifefloat › Float-free Link
Issued 6 June 2012 Resolved
Provide new weak link for lifefloat iaw 46CFR180.200.
Condition: Improper/Lack of Maintenance
Due 6 June 2012
Resolved 6 June 2012
Resolution: Item was corrected on the spot.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 6 June 2012 Resolved
Provide dead cover for breaker in engine room overhead iaw 46CFR183.330.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2012
Resolved 12 June 2012
Resolution: Provided appropriate cover.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 June 2012 Resolved
Secured lose covering on exposed ends wires iaw 46CFR183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2012
Resolved 12 June 2012
Resolution: All dead end wiring removed.
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 6 June 2012 Resolved
remove lose gear in the vicinity of the battery located on the bridge iaw 46CFR183.354.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2012
Resolved 12 June 2012
Resolution: All lose gear was removed or properly secured within the vicinity of the battery on the bridge.
Engineering › Bilge Water Management System › Hose
Issued 6 June 2012 Resolved
Replace hose for the MSD suction line iaw 46CFR182.720.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2012
Resolved 12 June 2012
Resolution: MSD hose replaced..
Fire Fighting › Fire Bucket › Capacity
Issued 6 June 2012 Resolved
Provide three 2.5 gallon fire bucket iaw 46CFR181.600.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2012
Resolved 12 June 2012
Resolution: Three 2.5 gallon fire buckets provided.
Communications › Radio Communications › EPIRB
Issued 5 June 2007 Resolved
Repair of replace EPIRB I.A.W. 46 CFR 180.64. Vessel is restricted to no more than three(3) miles from shore.
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 29 June 2007
Resolution: Owner replaced with new 406 MHZ EPIRB and provided proof of registration.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 13 July 2007
Resolution: Proof of Pre-Employment drug testing and enrollment in a random drug testing program provided.
Electrical › Lighting (emergency) › Grounding Conductor
Issued 5 June 2007 Resolved
Repair Emergency lighting in accommodations spaces throughout vessel I.A.W. 46 CFR 183.432. Vessel is restricted from use of passenger accommodation spaces.
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 29 June 2007
Resolution: Emergency lighting repaired, ops check normal.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2006 Resolved
Submit single line electrical drawing for approval for the electrical submersible bilge pump system. All electric submersible pumps must be disconnected from their power source and not used until the system is approved.
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 6 September 2006
Resolution: Submitted drawings and approved installation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2006 Resolved
The small galley freezers must be permanently wired with proper cable. A suitable receptacle may be mounted at each refrigerator location so that the manufacturer's original cable may be used for power. Submit a drawing for approval for this electrical repair.
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 6 September 2006
Resolution: Installed new receptacles and plugged freezers in.
Electrical › Electrical Distribution System (service) › Switch
Issued 29 June 2006 Resolved
Install a properly mounted sized and mounted motor controller for the port aft breathing air compressor. This compressor may not be used until this is complete.
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 29 July 2006
Resolution: Installed proper controller.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2006 Resolved
Properly wire the squirrel cage blower in the compressor room. Eliminate the hanging motor starting capacitor. Submit a single line electrical drawing from power source to motor for this circuit.
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 6 September 2006
Resolution: Removed blower and associated wiring.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2006 Resolved
Install marine grade cable of a minimum of 22 AWG for the bilge alarm system.
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 6 September 2006
Resolution: Installed 18 AWG wire.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2006 Resolved
Submit a single line diagram for approval of the small boat electric winch system. The small boat electric winch may not be used until drawing and installation is approved.
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 6 September 2006
Resolution: Submitted drawing, approved installation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2006 Resolved
Install metal hangers every 24" on main electrical cable bundles in the engine room.
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 6 September 2006
Resolution: Installed metal hangers.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2006 Resolved
Mount shore-tie electrical circuit breaker in a closed box. Eliminate the spliced jumper on the shore-tie breaker remote switch circuit.
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 6 September 2006
Resolution: Installed new box and removed splice.
Construction/Loadline › Penetrations › Gasket
Issued 28 June 2006 Resolved
Make chain locker and port & starboard void covers watertight.
Action required: 705 - Other - as specified
Due 28 July 2006
Resolved 6 September 2006
Resolution: Installed gaskets.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 28 June 2006 Resolved
Remove diesel fuel from engine room bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2006
Resolved 28 June 2006
Resolution: Removed diesel fuel.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 28 June 2006 Resolved
Repair/replace leaking fuel valves on starboard fuel tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2006
Resolved 29 June 2006
Resolution: Renewed valves.
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 June 2006 Resolved
Scrape to good wood and treat area on stbd main engine hatch support beam.
Action required: 705 - Other - as specified
Due 28 July 2006
Resolved 6 September 2006
Resolution: Removed rot and treated.
Construction/Loadline › Hull › Stringer
Issued 28 June 2006 Resolved
Remove rotted stringers below main engine hatch covers.
Action required: 705 - Other - as specified
Due 28 July 2006
Resolved 6 September 2006
Resolution: Removed rot.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 16 May 2005 Resolved
Replace as original rotted wood above generators in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2005
Resolved 15 August 2005
Resolution: Replaced wood as original above generators in engine room.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 May 2005 Resolved
Remove by cleaning/degreasing excessive grease around galley griddle.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2005
Resolved 19 May 2005
Resolution: Cleaned.
Fire Fighting › Grease Extraction Hood › General
Issued 16 May 2005 Resolved
Renew inoperable galley grease extraction hood and clean-out excessive grease build-up in vent ducting.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2005
Resolved 19 May 2005
Resolution: Replaced satisfactorily.
Lifesaving › Lifejacket/PFD (General)
Issued 13 June 2003 Resolved
2 child and 2 adult PFD's found to be unserviceable. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Due 17 June 2003
Resolved 17 June 2003
Resolution: Replaced with new PFD''''s.
Engineering
Issued 13 June 2003 Resolved
All Cable and wire in engineroom missing metal supports. LEGACY COMPONENT DESC: Cable & Wire supports
Condition: Unknown
Due 17 June 2003
Resolved 17 June 2003
Resolution: Replaced.
Lifesaving › Lifebuoys
Issued 13 June 2003 Resolved
One life ring buoy found to be unserviceable.
Condition: Unknown
Due 17 June 2003
Resolved 17 June 2003
Resolution: Replaced.
Communications › Radio Communications
Issued 13 June 2003 Resolved
EPIRB did not have current NOAA registration sticker. LEGACY COMPONENT DESC: EPIRB
Due 17 June 2003
Resolved 17 June 2003
Resolution: Found and placed on EPIRB.
Construction/Loadline › Hull
Issued 3 July 2002 Resolved
Crop out and renew as original fwd section of rotted keel and worm shoe. LEGACY COMPONENT DESC: Keel
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 5 July 2002
Resolution: Rotted sections of keel and wormshoe repaired satisfactorly.
Construction/Loadline › Hull
Issued 3 July 2002 Resolved
Crop out and renew aft section of rotted worm shoe. LEGACY COMPONENT DESC: Keel Plate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 5 July 2002
Resolution: Rotted worm shoe section repaired.
Construction/Loadline › Hull
Issued 3 July 2002 Resolved
Refasten fwd port garboard plank. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 5 July 2002
Resolution: Garboard plank refastened.
Construction/Loadline › Hull
Issued 3 July 2002 Resolved
Ensure all exterior hull fasteners are sealed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 5 July 2002
Resolution: All hull fasteners sealed.
Engineering › Sea-water System (primary cooling)
Issued 3 July 2002 Resolved
Provide valve handle for sea valve in steering compartment. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 5 July 2002
Resolution: Valve handle provided.
Construction/Loadline › Structures
Issued 3 July 2002 Resolved
Scrape/clean/treat rotted section of E/R bulkhead. Also port head sea suction doubler block. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 5 July 2002
Resolution: Rotted sections scraped and treated satisfactorily.
Construction/Loadline › Penetrations
Issued 3 July 2002 Resolved
Replace doubler block stbd head sea suction in E/R.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 5 July 2002
Resolution: Doubler block renewed.
Electrical › Lighting (service)
Issued 26 June 2002 Resolved
Engine room light base broken. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 July 2002
Resolved 27 June 2002
Resolution: Replaced.
Electrical › Lighting (service)
Issued 26 June 2002 Resolved
Light in crew bunk room missing cover. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2002
Resolved 27 June 2002
Resolution: Replaced.
Engineering
Issued 26 June 2002 Resolved
Port aft fuel vent screen wasted. LEGACY COMPONENT DESC: flame screen
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2002
Resolved 27 June 2002
Resolution: Replaced.
Navigation
Issued 26 June 2002 Resolved
Missing tide tables. LEGACY COMPONENT DESC: Tide Tables
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2002
Resolved 27 June 2002
Resolution: Provided.
Electrical › Electrical Distribution System (service)
Issued 2 February 2002 Resolved
Replace all SO, SOJ, STO wiring in vessel's A/C electrical system with approved marine grade wiring. Item to be completed prior to receiving credit for next required hull exam. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 3 July 2002
Resolution: All A/C elect wiring system replaced with approved wiring.
Fire Fighting
Issued 24 May 2000 Resolved
Have the two B-II fire extinguishers that are overdue for hydrostatic testing serviced.
Condition: Unknown
Due 3 June 2000
Resolved 3 June 2000
Fire Fighting
Issued 24 May 2000 Resolved
Provide a total of 6 B-II fire extinguishers on board (1 missing).
Condition: Unknown
Due 3 June 2000
Resolved 3 June 2000
Unknown
Issued 24 May 2000 Resolved
Provide a waste management plan for the vessel.
Condition: Unknown
Due 7 June 2000
Resolved 8 June 2000
Navigation
Issued 24 May 2000 Resolved
Provide updated and corrected charts for the vessel's operating area and provide current and updated light list.
Condition: Unknown
Due 7 June 2000
Resolved 8 June 2000
Lifesaving
Issued 24 May 2000 Resolved
Provide proof of servicing for the EPIRB hydrostatic release.
Condition: Unknown
Due 7 June 2000
Resolved 8 June 2000
Lifesaving
Issued 24 May 2000 Resolved
Provide proof of NOAA registration for the EPIRB.
Condition: Unknown
Due 7 June 2000
Resolved 8 June 2000
Accommodation/Occupational Safety
Issued 24 May 2000 Resolved
Clean grease from grill vent and install filter to prevent further accumulation.
Condition: Unknown
Due 7 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 24 May 2000 Resolved
Install captive devices on the following hatches: 1) fwd bunkroom emergencyescape 2) steering gear compartment 3) all 4 fish holds
Condition: Unknown
Due 3 June 2000
Resolved 3 June 2000
Lifesaving
Issued 24 May 2000 Resolved
Post a lifejacket donning placard.
Condition: Unknown
Due 7 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 24 May 2000 Resolved
Prove proper operation of all bilge high level alarms in all watertight compartments.
Condition: Unknown
Due 7 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 24 May 2000 Resolved
Provide a portable bilge pump capable of reaching the bottom of each watertight compartment while discharging overboard.
Condition: Unknown
Due 7 June 2000
Resolved 8 June 2000
Unknown
Issued 24 May 2000 Resolved
Until bilge high level alarms are installed in all compartments and functioning properly, have a crewmember conduct hourly checks on all watertight compartments and log completion of those checks in the ship's log whenever underway with passengers for hire.
Condition: Unknown
Due 7 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 30 July 1999 Resolved
Vessel restricted to no more than 100 miles from the mainland shore until marine inspector can re-inspect repair of portside shaft log/stern tube in next three months.
Condition: Unknown
Due 20 August 1999
Resolved 20 August 1999
Construction/Loadline
Issued 30 July 1999 Resolved
Clean & treat dry-rot in engine room, especially above the fuel tanks, prior to 15 SEP 99_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 August 1999
Resolved 20 August 1999
Fire Fighting
Issued 19 May 1999 Resolved
Prove proper operation of the fire pump.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Fire Fighting
Issued 19 May 1999 Resolved
Provide ventilation shutdown upon discharge of the C02 system.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Fire Fighting
Issued 19 May 1999 Resolved
Provide and post operating instructions for the C02 system.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Documentation
Issued 7 May 1992 Resolved
PROVIDE ALL REQUIRED RADIO EQUIPMENTS OUTLINED IN 47 CFR 80.905(a)(3), OR OBTAIN AN EXEMPTION FROM FCC. VESSEL ROUTE LIMITED TO NO MORE THAN 100 MILES OFF THE MAINLAND SHORE.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Unknown
Issued 10 May 1991 Resolved
DISPLAY ALL PAGES OF THE CERTIFICATE OF INSPECTION. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Unknown
Issued 10 May 1991 Resolved
PROVIDE CERTIFICATE OF SATISFACTORY EXAMINATION AND TESTING OF SAFETY _x001C_ RELIEF VALVES FOR THE HIGH PRESSURE COMPRESSED AIR SYSTEM FOR DIVING. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Electrical
Issued 10 May 1991 Resolved
REPAIR INOPERABLE FREQUENCY METER AND VOLTMETER FOR THE SHIP SERVICE _x001C_ GENERATORS IN THE ENGINEROOM. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Electrical
Issued 10 May 1991 Resolved
PROVE SATISFACTORY SPLIT OPERATION OF THE SHIP SERVICE DIESEL GENERATORS_x001C_ IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Unknown
Issued 10 May 1991 Resolved
PROVIDE RACK FOR THE FIRE MAIN STATION FIRE HOSE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Unknown
Issued 10 May 1991 Resolved
PROVIDE A CURRENT FCC COMMUNICATION ACT RADIOTELEPHONY CERTIFICATE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Unknown
Issued 10 May 1991 Resolved
PROVIDE AN UPDATED LIGHT LIST, TIDE AND CURRENT TABLES. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Unknown
Issued 10 May 1991 Resolved
PROVIDE THREE(3) BLACK BALL DAY SHAPES. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Unknown
Issued 10 May 1991 Resolved
REPAIR INOPERABLE ANCHOR WINCH._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Unknown
Issued 10 May 1991 Resolved
REPAIR INOPERABLE TACHOMETER IN THE PILOTHOUSE FOR THE PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Unknown
Issued 10 May 1991 Resolved
LABEL EMERGENCY LIGHTS WITH A RED LETTER "E" 1-INCH IN HEIGHT. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Navigation
Issued 11 May 1990 Resolved
PROVIDE A CURRENT DEVIATION TABLE FOR THE MAGNETIC COMPASS.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Fire Fighting
Issued 11 May 1990 Resolved
PROVIDE A SECONDARY SELF-PRIMING POWER FIRE PUMP WITH REMOTE START OUTSIDE OF THE ENGINE ROOM, FITTED WITH FIRE HYDRANT, FIRE HOSE AND NOZZLE. VESSEL IS RESTRICTED TO OCEAN ROUTE ZONE 1 UNTIL SATISFACTORY CORRECTED.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Unknown
Issued 11 May 1990 Resolved
PROVIDE CURRENT CERTIFICATION OF ANNUAL TESTING ON ALL SAFETY RELIEF VALVESFOR THE HIGH PRESSURE COMPRESS AIR SYTEM.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Unknown
Issued 11 May 1990 Resolved
HYDRO-TEST ALL AIR STORAGE CYLINDERS FOR THE HIGH PRESSURE COMPRESS AIR SYSTEM, 6 CYLINDERS IN WAY OF THE AIR COMPRESSOR ROOM AND 4 CYLINDERS AFT.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Engineering
Issued 11 May 1990 Resolved
PROVIDE AN ADDITIONAL FIXED POWER BILGE PUMP DRIVEN BY AN ALTERNATE SOURCE OF POWER FROM THE PRIMARY BILGE PUMP. VESSEL IS RESTRICTED TO OCEAN ROUTE ZONE 1 UNTIL SATISFACTORY CORRECTED.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Fire Fighting
Issued 11 May 1990 Resolved
PROVIDE ONE(1) FIRE AX ON BOARD. VESSEL IS LIMITED TO OCEAN ROUTE ZONE 1 UNTIL SATISFACTORY CORRECTED.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Lifesaving
Issued 11 May 1990 Resolved
PROVIDE TWELVE(12) PARACHUTE FLARES ONBOARD. VESSEL IS LIMITED TO OCEAN ROUTE ZONE 1 UNTIL SATISFACTORY CORRECTED.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Unknown
Issued 11 May 1990 Resolved
PROVE THE PROPER OPERATION OF THE PRESSURE CUT-OFF SWITCH ON ALL FOUR AIR COMPRESSORS.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Lifesaving
Issued 6 June 1989 Resolved
PROVIDE INSTRUCTION PLACARD ON LAUNCHING/DEPLOYING LIFERAFTS ON BOARD. POSTSAME IN CONSPICIOUS PLACE ACCESSIBLE TO CREW AND PASSENGERS.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Construction/Loadline
Issued 29 April 1986 Resolved
PLUG FASTENING HOLES AS INDICATED
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Construction/Loadline
Issued 29 April 1986 Resolved
REATTACH REACH ROD ON PORT SIDE VALVE AFT OF FRESH WATER TANK
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986

Casualty record · 3

19 May 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3272575
3 October 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3608033
23 March 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4826170
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.