STRAITS OF MACKINAC II

STRAITS OF MACKINAC II is a 1969 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 2016, most recently in June 2026, along with 68 deficiencies and 2 casualty investigations between 2013 and 2023.

Records from 2013 to 2026. Most recent: inspection, 25 June 2026.

Built
1969
Last inspected
25 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 June 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ4992
Flag
UNITED STATES
Maury page id
psix-46311

Documentation record

Registered dimensions (L × B × D)90.0 ft × 27.0 ft × 8.8 ft
Registered tonnagegross 89 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMACKINAC ISLAND, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

36 inspections, each with its date, unit and type; 68 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 36

25 June 2026 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8420547
2 December 2025 Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8276967
5 November 2025 Administrative Inspection · Special Consideration · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8264658
13 August 2025 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8210065
28 July 2025 Damage Survey · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8200034
23 July 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8193750
14 May 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8140938
18 December 2024 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8049196
18 November 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8047050
30 July 2024 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7967403
28 November 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7838269
12 August 2023 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7766152
11 August 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7770677
27 July 2023 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7814610
18 July 2023 Administrative Inspection · Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7750617
19 April 2023 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7672310
16 January 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7621961
5 January 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7617921
11 August 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7534371
12 January 2022 Administrative Inspection · Damage Survey · Examination of Repairs · COI Inspection · MTSA Verification · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7382360
13 October 2021 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7331628
6 July 2021 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7246537
11 September 2020 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7057504
7 July 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6999172
11 September 2019 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6809706
5 July 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6736920
31 October 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6577263
28 September 2018 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6561834
13 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539928
5 April 2018 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6385612
13 October 2017 Damage Survey · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6288703
18 September 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6291574
7 September 2017 COI Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6259541
22 February 2017 Deficiency Check · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6130580
11 October 2016 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6022068
23 May 2016 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5884699

Deficiency record · 68

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2025 Resolved
Circuit breakers installed onboard do not meet UL489.
Action required: 60 - Rectify deficiencies prior to movement
Due 2 December 2025
Resolved 23 December 2025
Resolution: All con-compliant circuit breakers were removed and replaced with UL489 compliant C/B's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 July 2025 Resolved
Removed 7 UV damaged adult PFDs from service.
Action required: 10 - Deficiency Rectified
Due 23 July 2025
Resolved 23 July 2025
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 23 July 2025 Resolved
One lifefloat needs the vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2025
Resolved 1 August 2025
Resolution: Corrected
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 23 July 2025 Resolved
Vessel's bilge manifold needs instructions for dewatering spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2025
Resolved 1 August 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 23 July 2025 Resolved
Found engine room emergency escape hatch seized in place.
Action required: 10 - Deficiency Rectified
Due 23 July 2025
Resolved 23 July 2025
Resolution: Corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 23 July 2025 Resolved
Found non return flaps on main deck freeing ports not freely opening and closing.
Action required: 10 - Deficiency Rectified
Due 23 July 2025
Resolved 23 July 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2025 Resolved
Battery box in machinery space not secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2025
Resolved 1 August 2025
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 July 2025 Resolved
Found the main deck and upper deck fire hoses and nozzles clogged with sediment.
Action required: 10 - Deficiency Rectified
Due 23 July 2025
Resolved 23 July 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2025 Resolved
Found multiple extension cords powering various items onboard. Including a refrigerator and electronic charging cables.
Action required: 10 - Deficiency Rectified
Due 23 July 2025
Resolved 23 July 2025
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 July 2025 Resolved
Found portable bilge pump suction hose improperly connected.
Action required: 10 - Deficiency Rectified
Due 23 July 2025
Resolved 23 July 2025
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 July 2025 Resolved
Found minor fuel leak on return line valve.
Action required: 10 - Deficiency Rectified
Due 23 July 2025
Resolved 24 July 2025
Resolution: Corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 23 July 2025 Resolved
Found packing on raw water valve leaking.
Action required: 10 - Deficiency Rectified
Due 23 July 2025
Resolved 23 July 2025
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 May 2025 Resolved
Main and aux. machinery were found oil covered. Engineroom bilges had excessive amount of oil accumulated creating a fire hazard. Must be cleaned and maintained.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 May 2025
Resolved 14 May 2025
Resolution: Engineroom machinery and bilges were cleaned, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 May 2025 Resolved
Pilothouse port MDE RPM gauge is inoperative, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 2 June 2025
Resolution: replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 May 2025 Resolved
Main and aux machinery must be monitored for excessive oil leaks and maintained in good, clean and operable condition. Leaks should be minimized and any further degradation must be immediately reported to the Sector NGL vessel inspections office.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2025
Resolved 20 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 30 July 2024 Resolved
Multiple maindeck windows cracked, broken, missing. Make safe for pax, repair/replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2024
Resolved 21 November 2024
Resolution: all maindeck windows were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2024 Resolved
Make collision blkhd bilge line closure valve function.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2024
Resolved 30 July 2024
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 30 July 2024 Resolved
All bilges require cleaning due to excessive debris, welding materials, trash, etc.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2024
Resolved 5 August 2024
Resolution: corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 30 July 2024 Resolved
Maindeck cleanliness unacceptable for safe passenger loading and carriage. Must be cleaned.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2024
Resolved 5 August 2024
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 July 2024 Resolved
Pilothouse port MDE tachometer inop, requires repair/replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2024
Resolved 11 December 2024
Resolution: repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 July 2024 Resolved
Port MDE has oil leak. Determine source & effect permanent repairs. Demonstrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2024
Resolved 11 December 2024
Resolution: repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2024 Resolved
Genset fuel line chaffed, requires replacement.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2024
Resolved 11 December 2024
Resolution: replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2023 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel reported to [name withheld], of RPM fluctuations on the main diesel engines. Vessel secured the port generator which brought both main diesel engines offline. Vessel was unable to restart main diesel engines and required tow assist from nearby vessel to Mackinaw City, [name withheld] indicated that the vessel ran out of fuel during last transit into Mackinaw City. Vessel refueled and tested all machinery. Master intends to revise company procedures to ensure all vessel captains top off fuel tanks prior to end of shifts.
Action required: 10 - Deficiency Rectified
Resolved 12 August 2023
Resolution: Vessel topped off fuel tanks and ran machinery for 20 mintues satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 18 July 2023 Resolved
Maindeck forward portion of the vessel requires freeing ports; during the 2022 hull exam & subsequent repairs freeing ports were not calculated or installed. Submit calculations sheet and freeing port installation plan for approval.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 17 November 2023
Resolution: Received freeing port calc sheet, confirmed calcs & Star Line Naval Architect engagement. Found calcs sufficient, exceeded minimum requirements. Approved the installation method and locations.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 July 2023 Resolved
Stbd side genset exhaust is missing lagging creating a hazard to personnel and potential fire hazard. Must be properly lagged. Stbd side MDE exhaust muffler sheet metal is deformed creating a snag hazard, must be corrected/repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 4 August 2023
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 July 2023 Resolved
Shaft alley bilge alarm is not functioning; repair/replace & prove proper operation. ** Compartment must be checked regularly until corrections have been made.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 17 June 2024
Resolution: corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 18 July 2023 Resolved
2 windows cracked on maindeck. Must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2023
Resolved 28 August 2023
Resolution: replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2023 Resolved
Multiple wiring issues sighted in the pilothouse. Remove deadend wiring. Properly terminate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2023
Resolved 3 August 2023
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 January 2023 Resolved
Port side genset has excessive oil leak and unapproved flexible fuel line installed. Port genset must be taken out of service and not used until both items are corrected.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2023
Resolved 5 January 2023
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 January 2023 Resolved
Both MDEs and stbd genset have oil leaks. Determine the source of each leak and make repairs. **Leaks must be monitored dialy and any degradation must be immediately repoarted to the cognizant OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2023
Resolved 19 April 2023
Resolution: Received report from company rep that all oil leaks have been corrected. Attended vsl, witnessed gaskets replaced & sat operational checks.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 August 2022 Resolved
Steering cable improperly routed, must be corrected.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 August 2022
Resolved 2 August 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 1 August 2022 Resolved
Old fuel fill piping must be removed and fill port properly capped.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 August 2022
Resolved 2 August 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 August 2022 Resolved
Engineroom bilge has oil & debris, must be properly cleaned to avoid fire hazard, bilge plumbing clog hazard and pollution potential hazard. Insulation installation must be completed.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 August 2022
Resolved 2 August 2022
Resolution: corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 1 August 2022 Resolved
Sighted 3 broken windows, must be made safe for passengers & replaced. ** Extended due to vendor availability/scheduling.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 11 August 2022
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 August 2022 Resolved
Minimum flares not on board. Flare container not on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 1 August 2022 Resolved
Show proof of original COD on board or apply for replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2022 Resolved
Clean up wiring under helm; remove or properly deadend any wiring no longer in use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2022
Resolved 11 August 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 1 August 2022 Resolved
Forward portions on maindeck & 2nd deck need cordon lines and proper signage (no passengers allowed).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 11 August 2022
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 August 2022 Resolved
#1 genset (port side) has fuel leak. Do not operate until repairs have been completed and operation witnessed by a CG Marine Inspector.
Action required: 705 - Other - as specified
Due 1 August 2022
Resolved 29 November 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 August 2022 Resolved
Engine room deck plates must be moved or guards fashioned to prevent hazards to rotating machinery (shafts).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 29 November 2022
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 July 2021 Resolved
Maindeck aft PFE bracket loose, must be repaired/replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 26 July 2021
Resolution: corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 July 2021 Resolved
Main deck accommodation space window missing on stbd side, must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2021
Resolved 26 July 2021
Resolution: replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 July 2021 Resolved
Lazarette access cover gasket requires replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 26 July 2021
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2021 Resolved
Port MDE jacket water temp gauge inop at wheelhouse; port MDE has coolant leak at temp sending unit; repair/replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 26 July 2021
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2021 Resolved
Stbd MDE exhaust lagging loose, must be properly secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 26 July 2021
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 July 2021 Resolved
Port genset fuel return line kinked, non-standard flex piping installed, both must be replaced. Oil leak at dipstick, repair or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 26 July 2021
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 September 2020 Resolved
Engineroom overhead lagging deteriorated, must be re-installed or replaced for sufficent fire/heat boundary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2020
Resolved 7 July 2021
Resolution: corrected, however several insulation panels remain loose. will re-issue def if not corrected at up-coming annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2019 Resolved
Internally inspect all life jackets and replace retro tape on those that need it. During next 2 transits, ensure box of new life jackets is on board during voyage. 46 CFR 122.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2019
Resolved 7 July 2020
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 September 2019 Resolved
Replace cracked windows on main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2019
Resolved 7 July 2020
Resolution: replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 September 2019 Resolved
Clean navigational light to ensure visibility.
Action required: 10 - Deficiency Rectified
Due 11 September 2019
Resolved 11 September 2019
Resolution: Cleaned
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 September 2019 Resolved
Replace 2 broken paddles on Life Floats.
Action required: 10 - Deficiency Rectified
Due 11 September 2019
Resolved 11 September 2019
Resolution: Paddles replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 September 2018 Resolved
Post the COI in a conspicuous place visible to the passengers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2018
Resolved 31 October 2018
Resolution: posted
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 28 September 2018 Resolved
Post the stability letter addendum at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2018
Resolved 31 October 2018
Resolution: posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2018 Resolved
Monitor stbd MDE oil leak. Prove proper operation after winter overhaul.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2019
Resolved 20 June 2019
Resolution: Repairs completed to MDE.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 September 2018 Resolved
Re-mount fire pump electrical junction box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2018
Resolved 31 October 2018
Resolution: properly mounted.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
The vessel is currently broadcasting (1) Improper MMSI Number, (2) Improper Call Sign, (2) Zero Length and Beam (3) Zero Draft, (4) No Ship Type. Ship Type should be 60 per the US Official Encoding guide.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 October 2018
Resolved 31 December 2020
Resolution: Received statement from company Sr. Captain attesting to the AIS being updated to transmit the correct information.
Construction/Loadline › Structures › Deck Plating
Issued 13 October 2017 Resolved
Make permanent repairs to aft portside deck plate IWO mooring bit.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2017
Resolved 19 October 2017
Resolution: All repairs and NDT completed satisfactorily.
Lifesaving › Lifefloat › Serviceable
Issued 7 September 2017 Resolved
Replace deteriorated basket retainer line in life floats.
Condition: Improper/Lack of Maintenance
Due 21 September 2017
Resolved 18 September 2017
Lifesaving › Lifefloat › Markings
Issued 7 September 2017 Resolved
Mark life float with persons capacity.
Condition: Improper/Lack of Maintenance
Due 21 September 2017
Resolved 18 September 2017
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 September 2017 Resolved
Properly mount float light brackets for 4 life floats.
Condition: Improper/Lack of Maintenance
Due 21 September 2017
Resolved 18 September 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 September 2017 Resolved
Operational crew in attenance during inspection failed to demonstrate adequate proficiency in general operation, and emergency drills, corrected during inspection, crew was replaced.
Condition: Placed in Improper Service
Due 7 September 2017
Resolved 7 September 2017
Resolution: required immediate correction, crfew was replaced with properly trained individuals.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 September 2017 Resolved
8 adult size PFD rejected, replaced during inspection.
Condition: Improper/Lack of Maintenance
Due 7 September 2017
Resolved 7 September 2017
Personnel › Training › Familiarization Training
Issued 7 September 2017 Resolved
Crew initially provided during inspection was inadequately trained, see Narrative. Crew was replaced with properly trained personnel.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2017
Resolved 7 September 2017
Resolution: Corrected during inspection.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 11 October 2016 Resolved
Properly label engineroom emergency escape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 28 October 2016
Resolution: Completed, all sat.
Engineering › Bilge Water Management System › Manifold
Issued 11 October 2016 Resolved
Label bilge manifold for understandable operation/instructions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 28 October 2016
Resolution: Completed, all sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 11 October 2016 Resolved
Label all portable fire ext. fire stations and remove markings from stations no longer in use.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 28 October 2016
Resolution: Completed, all sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 October 2016 Resolved
Distribute and properly mark child size PFD's/storage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 28 October 2016
Resolution: Child size PFD's properly distributed and location properly marked.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 October 2016 Resolved
Emergency procedures not posted at operating station.
Action required: 705 - Other - as specified
Resolved 11 October 2016
Resolution: Corrected on the spot.

Casualty record · 2

7 August 2013Routine · role: Involved in a Marine Casualty · activity 4677996
11 August 2023Routine · role: Involved in a Marine Casualty · activity 7770677
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.