TELSTAR

TELSTAR is a 1969 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1985, most recently in September 2025, along with 164 deficiencies, 1 operational control and 3 casualty investigations between 2017 and 2021.

Records from 1985 to 2025. Most recent: inspection, 23 September 2025.

Built
1969
Last inspected
23 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL5252
Flag
UNITED STATES
368139350
Maury page id
psix-46316

Inspections, by type

…with no type recorded13
Years with a record 39 calendar years (1985–2025)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)47.0 ft × 16.2 ft × 7.3 ft
Registered tonnagegross 37 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHERMODYNE INC · MARYSVILLE, WA, UNITED STATES · built 1969
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT BRAGG, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Simplified, Gross Ton
29 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL5252MMSI 368139350 · active · compulsorily equipped · granted 28 March 2020, expires 28 March 2030
WDE5809MMSI 367371910 · expired · compulsorily equipped · granted 6 August 2008, cancelled 6 October 2018
WCX4123MMSI not assigned · expired · compulsorily equipped · granted 12 June 1998, cancelled 24 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 87

23 September 2025 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 8215882
23 October 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 8015677
27 March 2024 Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7889931
23 October 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7811235
28 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7613903
27 October 2022 Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7585639
19 October 2022 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7581708
25 April 2022 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7438811
3 November 2021 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7344742
23 August 2021 Type not recorded
No type recorded · Station Noyo River · USCG Southwest District (CGD-SW) · Activity 7294826
23 August 2021 Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7300600
30 November 2020 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7103746
25 October 2020 Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7083639
24 October 2020 Type not recorded
No type recorded · Station Noyo River · USCG Southwest District (CGD-SW) · Activity 7083757
30 September 2020 COI Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7068622
16 June 2020 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6978531
23 December 2019 Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6884174
16 December 2019 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6875590
20 December 2018 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6618659
9 May 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6442582
13 December 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6326724
4 December 2017 Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6318034
22 December 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6057936
4 May 2016 Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 5869250
30 September 2015 COI Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 5238366
20 May 2014 Drydock Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 4815448
22 May 2012 Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4315190
30 December 2011 Simplified Stability Test · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4216113
29 September 2010 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3859567
28 July 2009 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3716601
10 November 2008 Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3645604
28 May 2008 Drydock Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3221967
30 May 2007 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2945412
3 May 2006 COI Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2626781
18 August 2004 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2169471
27 June 2003 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1829125
9 June 2003 Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1809860
28 April 2003 Drydock Extension
Administrative · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1783896
17 July 2002 Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1787993
12 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075389
5 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075335
2 August 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 172120
23 May 2001 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1460546
28 February 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1460547
13 September 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1423597
8 July 1999 Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1423596
11 March 1999 Deficiency Check · Plan Review "T" Boat
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1035299
22 February 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1100171
17 June 1998 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1432125
8 July 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1428795
20 May 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1112384
6 February 1997 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1106474
6 February 1997 Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1106646
25 October 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 851696
28 November 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1192696
11 October 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1188028
18 July 1995 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1460796
11 May 1995 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1367383
27 April 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 711189
27 May 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 861227
24 June 1993 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1354380
12 February 1993 Plan Review "T" Boat
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 830537
21 January 1993 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1359465
1 July 1992 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1268353
9 April 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 958239
11 December 1991 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 948594
7 November 1991 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 940381
14 May 1991 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1229212
18 April 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 926022
23 October 1990 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 924305
17 May 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 931814
21 March 1990 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1225054
8 August 1989 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1035385
24 April 1989 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1206484
6 January 1989 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1045394
13 December 1988 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1340506
18 November 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1204787
1 July 1988 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1031882
27 May 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1026322
20 May 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1336123
15 May 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1332790
17 March 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1016580
8 April 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 999342
20 March 1986 Re-Inspection · Credit Drydock
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1303600
8 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1288659
22 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1287296
14 March 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 978003

Deficiency record · 164

07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 23 September 2025 Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Operator to repair hole in engine room forward bulkhead to the satisfaction of the Marine Inspector. 46 CFR 177.405(c)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 2 October 2025
Resolution: Operator submitted sufficient photo documentation to clear deficiencies.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 September 2025 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light. Operator to repair 01 non-functioning life jacket lights to the satisfaction of the Marine Inspector. Maximum passenger count to be reduced by one (01) until repaired. 46 CFR 180.75(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 October 2025
Resolution: Operator submitted sufficient photo documentation to clear deficiencies.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2024 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross-sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Vessel’s port fuel tank missing flame screen. Operator to replace to the satisfaction of the marine inspector. 46 CFR 182.450 (e)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 5 November 2024
Resolution: Received satisfactory photo evidence to clear deficiency.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 October 2024 Resolved
Vessel did not have a log as required by 46 CFR 185.420 - crew training, 46 CFR 185.520 – abandon ship and man overboard drills, 46 CFR 185.524 – firefighting drills, 46 CFR 185.702 – maintenance of survival craft, 46 CFR 185.728 – EPIRB testing. Operator to provide evidence of existing log, or start new log, to the satisfaction of the marine inspector. 46 CFR 185.420
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 5 November 2024
Resolution: Received satisfactory photo evidence to clear deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Vessel is missing one adult and two child life-jackets according to count on COI. Vessel is limited to 29 adult and 01 child passengers until replaced to the satisfaction of the marine inspector. 46 CFR 180.71
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 14 November 2024
Resolution: Received satisfactory photo evidence to clear deficiency.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 October 2024 Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) to be protected by the interconnected detection and alarm system. Vessel does not have an interconnected alarm system installed. Vessel’s COI is for an Ocean route, however, vessel is now restricted to a Limited Coastwise Route until interconnected detection and alarm system is installed to the satisfaction of the marine inspector. 46 CFR 181.450
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 14 November 2024
Resolution: Received satisfactory video evidence to clear deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 18 April 2024 Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Vessel operator has expired medical certificate. Vessel to provide documentation of valid/unexpired medical certificate, to the satisfaction of the Marine Inspector, prior to the carriage of passengers. 46 CFR 185.402 46 CFR 15.401 (c)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2024
Resolution: Operator sent proof of medical certificate being mailed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel has deck support beam in forepeak area no longer attached. Vessel to repair to satisfaction of the marine inspector. Vessel to repair or replace in accordance with approved plan prior to credit dry dock. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 November 2023
Resolution: Vessel submitted photo evidence of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 November 2023 Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Vessel has broken bilge line connection. Vessel to repair to satisfaction of the marine inspector. 46 CFR 182.510(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2023
Resolution: Vessel submitted photo evidence of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2023 Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 30 inches and subject to pressures of not more than 5 psi, may meet the following requirements: Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. Vessel has non-metallic pipe not double clamped. Vessle to install two clamps, at both ends of the hose to the satisfaction of the marine inspector. 46 CFR 182.72 (e)(3)(v)(B)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2023
Resolution: Vessel submitted photo evidence of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2023 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Vessel using fuel filter with no bowl attached. Vessel to install metal bowl on fuel filter assembly to satisfaction of the marine inspector. 46 CFR 182.455(b)(6)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2023
Resolution: Vessel installed metal bowl on fuel filter assembly.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 November 2023 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be approved by the Commandant; Be installed in accordance with the manufacturer's instructions. Vessel has temporarily unused ducting in engine room creating ventilation opening into space. Vessel to seal opening to satisfaction of the marine inspector. 46 CFR 141.420(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2023
Resolution: Vessel submitted photo evidence of repair.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 November 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel to repair forward mast head light and starboard running light to satisfaction of the marine inspector prior to operations at night. 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 May 2024
Resolution: Updated with new def. See activity #7889931 for details.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2023 Resolved
Each life jacket carried on a vessel on oceans or coastwise route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter. Vessel has 06 life jackets with nonworking lights. Vessel's max passenger count to be reduced by 06 persons from that listed on COI until repair completed to satisfaction of the marine inspector. 46 CFR 180.75(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 November 2023
Resolution: Vessel submitted photo evidence of repair.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 November 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel has expired first-aid kit contents (ammonia inhalant, aspirin, burn gel, eye wash). Vessel to replace with unexpired items to satisfaction of the marine inspector. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2023
Resolution: Vessel submitted photo evidence of repair.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 November 2023 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03–2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel to replace expired alcohol testing devices to satisfaction of the marine inspector. 46 CFR 185.212 46 CFR 4.06-15(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2023
Resolution: Vessel submitted photo evidence of repair.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 1 November 2023 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Vessel has forward end of main engine, with exposed rotating belts and pulleys, not protected by a guard. Vessel to install guard or rail to satisfaction of the marine inspector. 46 CFR 177.960
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 December 2023
Resolution: Vessel submitted photo evidence of repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 November 2023 Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. Vessel has engine room batteries not protected. Vessel to install covers for batteries to satisfaction of the marine inspector. 46 CFR 186.354
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 December 2023
Resolution: Vessel submitted photo evidence of repair.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have installed detectors in required spaces by 27Dec2022. Vessel has been limited to a Limited Coastwise route until detector installation has been verified by a Marine Inspector. 46 CFR 181.405(c)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 May 2024
Resolution: Updated with new def. See activity #7889931 for details.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 October 2022 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The disposable hydrostatic release that allows the EPIRB to float free, is expired. Install a new un-expired hydrostatic release that allows float free operation of the EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2022
Resolved 27 October 2022
Resolution: A new non-expired hydrostatic release was installed on the EPIRB to allow float free operation.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 16 June 2020 Resolved
Vessels operated beyond the 20 nautical miles, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of §80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz,or a functioning satellite phone. The DSC function was not operable on the vessels MF Radio.Provide MF radio installation with functioning DSC or a functioning satellite phone.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2021
Resolved 9 November 2020
Resolution: A satellite phone was placed in service aboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 June 2020 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with §181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section: (1) A space containing propulsion machinery; (2) A space containing an internal combustion engine of more than 37.3 kW (50 hp) The generator space containing the ships service diesel generator was not equipped with any fixed gas fire extinguishing system. Operation of the ships service diesel generator is prohibited until an approved fixed gas fire extinguishing system is installed, or proof that the Diesel engine is not more than 50 horse power.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2020
Resolved 9 November 2020
Resolution: The Diesel generator was disabled and cannot be energized.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 December 2019 Resolved
The master of the vessel shall ensure that: Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable the required EPIRB tests were not being logged. Provide record and maintain onboard the vessel of EPIRB tests.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2019
Resolved 23 December 2019
Resolution: A new EPIRB log was placed in service aboard the vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 December 2019 Resolved
The master of the vessel shall ensure that the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. The vessels EPIRB battery is expired. Replace vessels EPIRB battery or install a new EPIRB with an unexpired battery.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2019
Resolved 23 December 2019
Resolution: A new EPIRB with un-expired battery was placed in service aboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 December 2019 Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. The hydrostatic release that allows the liferaft to automatically float free was expired. Install new unexpired hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2019
Resolved 23 December 2019
Resolution: A new non-expired hydrostatic release was properly installed to secure the vessels liferaft.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 December 2019 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry, Six hand red flare distress signals approved in accordance with §160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and, Six hand orange smoke distress signals approved in accordance with §160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. There were only three orange smoke distress signals onboard the vessel. Three additional unexpired orange smoke distress signals shall be placed in service onboard the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2019
Resolved 23 December 2019
Resolution: The correct number and type of visual distress signals were placed in service aboard the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 December 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The first aid kit contained several items that were expired. Provide new first aid kit, or replace expired items with new non expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2020
Resolved 16 June 2020
Resolution: A new first-aid kit was placed in service aboard the vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 December 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2020
Resolved 16 June 2020
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 December 2019 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The FCC Safety Radio Certificate was expired. A new unexpired FCC Safety Radio Certificate must be obtained and placed aboard the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2020
Resolved 16 June 2020
Resolution: The owner obtained a new FCC Safety Radio Certificate.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 16 December 2019 Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of §80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz, in addition to the VHF-DSC radiotelephone installation required by paragraph (a)(1) of this section. The DSC function was not operable on the vessels VHF, and MF radios. Provide vessel with 01 VHF radio installation with functioning DSC, and 01 MF radio installation with functioning DSC.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2020
Resolved 16 June 2020
Resolution: The owner installed the necessary equipment to provide the VHF radio with functional DSC.
Lifesaving › Lifebuoys › Serviceable
Issued 13 December 2017 Resolved
Worn out seagull pecked deteriorated ring buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2018
Resolved 10 January 2018
Resolution: Renewed
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 December 2017 Resolved
Hand rails port and starboard attached to pilot house loose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2018
Resolved 10 January 2018
Resolution: Repaired
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 13 December 2017 Resolved
Worn out shaft packing, excessive leakage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 9 May 2018
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 9 October 2015 Resolved
Starboard bridge window is cracked. The operator's visibility at the operating station is diminished.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 30 October 2015
Resolution: Bridge window was replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 9 October 2015 Resolved
Forward engine room bulkhead on port side must be vapor tight. Currently a gap is filled with expandable foam. Operator must remove expandable foam and replace with fire retardant material.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 30 October 2015
Resolution: The gap in the bulkhead was filled by applying a new layer of fiberglass to the bulkhead. Forward bulkhead of engine room is now vapor tight.
Engineering › Bilge Water Management System › Not Operational
Issued 30 September 2015 Resolved
Lazerette bilge pump was not operational when initially tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: New bilge pump was installed and tested on the spot. Bilge pump test was satifactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 September 2015 Resolved
Port and Starboard navigation light mounts were inadequate. Light fixtures were not securely mounted to the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: Navigation lights were mounted to the vessel in a way that they could not shift during vessel operations.
Fire Fighting › Fire Bucket › Capacity
Issued 30 September 2015 Resolved
Fire Buckets were of incorrect size. Buckets provided for the inspection were 5 gallon capacity.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: 2.5 gallon buckets were acquired by vessel operator and placed into service.
Engineering › Bilge Water Management System › Pump
Issued 30 September 2015 Resolved
Bilge pump is not permanently mounted in lazarette space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: The bilge pump in the lazarette space was permanently mounted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 September 2015 Resolved
Bus bars located in the forward accommodation space must be covered to protect passengers and crew from electrical shock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: Bus bars located in the forward accommodation space were covered in an acceptable fashion.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 30 September 2015 Resolved
All broken windows in or around passenger accessible spaces need to be replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 30 September 2015
Resolution: The broken window in the passenger accessible space was replaced.
Documentation › Markings/Placards › Warning Signs
Issued 9 May 2012 Resolved
Properly label Escape Hatch on the interior of the vessel. 46 CFR 185.30-15
Due 22 May 2012
Resolved 22 May 2012
Resolution: Escape hatch properly labeled on interior
Lifesaving › Buoyant Apparatus › Marking
Issued 9 May 2012 Resolved
Replace and label broken paddle in buoyant apparatus. 46 CFR180.75(2)
Due 22 May 2012
Resolved 22 May 2012
Resolution: provided new paddle with vessel name
Electrical › Electrical Distribution System (service) › Cable
Issued 9 May 2012 Resolved
Remove (SEOW) electrical cable. 46 CFR 183.10-20 (2)
Due 22 May 2012
Resolved 22 May 2012
Resolution: cable removed
Stability › Watertight Integrity › General
Issued 9 May 2012 Resolved
Properly seal holes and openings in engine room. 46 CFR 181.420 (a) (4)
Due 9 June 2012
Resolved 1 March 2013
Resolution: Photos provided holes sealed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 May 2012 Resolved
Properly secure electrical wiring that has wire nuts by enclosing in a junction box or removing and re-splicing with approved connections. 46 CRF 183.05-50 (b)
Due 22 May 2012
Resolved 22 May 2012
Resolution: wiring connected with approved connectors
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 May 2012 Resolved
Fire Boy clean agent bottle requires recertification. Renew bottle with one with a current hydro test date or have a DOT certfied company conduct recert and label hydro exempt. 46 CFR 176.810 (5)
Due 22 May 2012
Resolved 11 December 2012
Resolution: Bottle was inspected by DOT certified company and stamped Hydro exempt.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2012 Resolved
Properly secure Electronic's batteries in engine room in a corrosive resistant box. 46 CFR 183.05-20 (b)
Due 22 May 2012
Resolved 22 May 2012
Resolution: Batteries placed in a corrosive resistant container
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 9 May 2012 Resolved
Conduct proper repairs to loose hand rails on weather deck. 46 CFR 177.35-1
Due 22 May 2012
Resolved 1 March 2013
Resolution: Repairs conducted to deck railings
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 May 2012 Resolved
Provide machinery guards to MDE. 46 CR 177.35-15
Due 9 June 2012
Resolved 1 March 2013
Resolution: Provided photo of installed guard.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Electric Bonding
Issued 9 May 2012 Resolved
Provide proper bonding to fuel fill pipeson port and stbd fuel tanks. 46 CFR182.20-30(d)
Due 22 May 2012
Resolved 24 January 2013
Resolution: Photos provided of bonding.
Construction/Loadline › Structures › Scuttle
Issued 9 May 2012 Resolved
Provide captive chain on laz scuttle. 46 CFR 182.20-35
Due 22 May 2012
Resolved 22 May 2012
Resolution: Captive chain provided on laz scuttle
Engineering › Fuel Oil Service System › Vent Pipe
Issued 9 May 2012 Resolved
Properly repair port fuel vent pipe and provide 30x30 wire mesh flame screen. 46 CFR 182.20-35
Due 22 May 2012
Resolved 22 May 2012
Resolution: Port fuel vent repaired and 30x30 flame screen installed
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 30 December 2011 Resolved
properly install keel cooler shut off valve. IAW 46 CFR 182.422 (b)
Due 9 June 2012
Resolved 17 April 2014
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 October 2010 Resolved
The light list onboard was outdated. Provide updated USCG light list onboard the vessel.
Action required: 705 - Other - as specified
Due 28 October 2010
Resolved 14 October 2010
Resolution: Provided updated light list.
Navigation › Piloting/Steering › Marine Charts
Issued 13 October 2010 Resolved
The charts currently onboard the vessel were issued in 1987. Provide updated charts for the operating area of the vessel.
Action required: 705 - Other - as specified
Due 28 October 2010
Resolved 14 October 2010
Resolution: Provided updated charts onboard.
Lifesaving › Lifebuoys › Serviceable
Issued 13 October 2010 Resolved
Install retro-reflective material to life ring buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 October 2010
Resolved 14 October 2010
Resolution: Installed retro-reflective tape to the lifering buoy.
Communications › Radio Communications › EPIRB
Issued 29 September 2010 Resolved
Vessel's EPIRB did not have a current NOAA registration. Provide proof of current EPIRB registration prior to operating beyond 3 miles from the coastline.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 October 2010
Resolved 14 October 2010
Resolution: The owner of the vessel showed proof of EPIRB registration.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 September 2010 Resolved
Battery was found to be expired. Replace waterlight batterry to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 14 October 2010
Resolution: Replaced battery.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 28 July 2009 Resolved
Documentation showing all crew members currently enrolled in a drug testing program is not available at the time of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2009
Resolved 2 September 2009
Resolution: Documentation provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 28 July 2009 Resolved
Documentation of inspection/servicing of the fixed fire-fighting system is not available at the time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2009
Resolved 2 September 2009
Resolution: Service documentation provided.
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 July 2009 Resolved
Remote emergency shut off valve on the port fuel tank is not functioning and the fire protection cover for the handle is loose (does not provide the necessary protection).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2009
Resolved 2 September 2009
Resolution: Valve is operational and cover is in place.
Lifesaving › Launching Appliances › Release Mechanism
Issued 28 July 2009 Resolved
Hydrostatic release was beyond it's service life. Provide new hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2009
Resolved 2 September 2009
Resolution: New hydrostatic release is in place.
Engineering › Bilge Water Management System › Valve
Issued 28 July 2009 Resolved
Repair bilge shut off valve aft of the forepeak. Currently does not close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2009
Resolved 31 July 2009
Resolution: Valve is now operational.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 July 2009 Resolved
Remove wire nuts from bilge pump wiring assemble in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2009
Resolved 2 September 2009
Resolution: Wire nuts have been removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2008 Resolved
Remove exposed wires found in Engine Room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2008
Resolved 10 November 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2008 Resolved
Provide proper supports (metal) for wiring in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2008
Resolved 10 November 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 28 May 2008 Resolved
Seal gaps in ventilation (engine room and openings in bulk head)
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2008
Resolved 10 November 2008
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 28 May 2008 Resolved
Wipe down (remove) excess oil sprayed onto alternator & wood at aft end of engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2008
Resolved 10 November 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 28 May 2008 Resolved
Replace the cracked aft port deck window.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2008
Resolved 10 November 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 28 May 2008 Resolved
Provide backing to port light assembly in engine room and generator space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2008
Resolved 10 November 2008
Construction/Loadline › Hull › Transverse Frame
Issued 28 May 2008 Resolved
Remove firing (deteriorated wood) from around engine and exhaust.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2008
Resolved 10 November 2008
Resolution: Firring has been removed. Issue will continue to be re-occurring due to a lack of circulating air in e/r. O/o will attempt to increase airflow in e/r to minimize continued firring.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 30 May 2007 Resolved
Ensure fixed fire-fighting system tank is inspected as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2007
Resolution: Received fax comfirmation of completion.
Documentation › Certificates/Documents › FCC SSL
Issued 30 May 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 10 November 2008
Resolution: Copy of FCC station license provided.
Engineering › Bilge Water Management System › Valve
Issued 3 May 2006 Resolved
Renew or replace gate valve for bilge water system at collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 24 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 August 2004 Resolved
Electrical wires remove dead end wires and enclose all wire splices.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2004
Resolved 15 June 2005
Construction/Loadline › Structures › Ventilators
Issued 18 August 2004 Resolved
In way of main deck stbd side make repairs to FRP at vents where cracked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 September 2004
Resolved 1 June 2005
Construction/Loadline › Structures › Deck Plating
Issued 18 August 2004 Resolved
In way of main deck stbd side crop out and renew rotton under deck supports.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 December 2004
Resolved 1 June 2005
Engineering › Bilge Water Management System › Piping
Issued 18 August 2004 Resolved
Bilge piping found loose double hose clamp all connections
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2004
Resolved 1 June 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 June 2003 Resolved
Remove from fixed firefighting system wire nuts used for joining wiring,and properly connect wires with butt connectors.
Due 11 June 2003
Resolved 11 June 2003
Stability › Watertight Integrity
Issued 9 June 2003 Resolved
Make watertight the forward engine room bulkhead in way of 4 inch square hole that penetrates to generator compartment. LEGACY COMPONENT DESC: Bulkhead
Due 11 June 2003
Resolved 11 June 2003
Stability › Watertight Integrity
Issued 9 June 2003 Resolved
Make water tight the number 2 bulkhead in way of holes for piping and wiring runs. LEGACY COMPONENT DESC: Bulkhead
Due 11 June 2003
Resolved 11 June 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 June 2003 Resolved
Repair to working condition the stern light.
Due 9 June 2003
Resolved 9 June 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 June 2003 Resolved
Provide on board vessel updated applicable light list for vessel operating zone.
Due 11 June 2003
Resolved 11 June 2003
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 June 2003 Resolved
Provide on board updated copie of Coast pilot applicable to the vessel's operating zone.
Due 18 June 2003
Resolved 11 June 2003
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 July 2002 Resolved
Provide documentation that all crew members are enrolled in drug testing program.
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 18 July 2002
Documentation › Certificates/Documents
Issued 17 July 2002 Resolved
Conduct radio safety testing to renew Radiotelephony Safety Certificate LEGACY COMPONENT DESC: Radiotelephone Safety Certificate
Due 16 August 2002
Resolved 18 July 2002
Documentation › Markings/Placards
Issued 17 July 2002 Resolved
Post in the vicinity of operating station/vhf radio an Emergency Broadcast placard LEGACY COMPONENT DESC: Emergency Broadcast placard
Due 30 August 2002
Resolved 28 August 2002
Documentation › Markings/Placards
Issued 17 July 2002 Resolved
Post life jacket donning procedure placard for each type of life jacket carried on board and display in conspicious area that is visible to all passengers. LEGACY COMPONENT DESC: Lifejacket donning procedures
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 28 August 2002
Engineering › Bilge Water Management System
Issued 17 July 2002 Resolved
Properly label bilge manifold valves and provide diagrahm and instructions for proper procedure and use.
Due 30 August 2002
Resolved 28 August 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 July 2002 Resolved
Re-install fixed gas fire fighting system in engine room on receipt back from servicing facility.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2002
Fire Fighting
Issued 23 May 2001 Resolved
WEIGH & CONDUCT INSPECTION ON FIXED FIRE SYSTEM, ADJUST ENGINE SHUTDOWN TO FULLY SECURE ENGINE.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Lifesaving
Issued 23 May 2001 Resolved
TEST SWITCH ON EPIRB TO OPERATE IN TEST MODE.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Navigation
Issued 23 May 2001 Resolved
REPLACE BULB IN STBD NAV LIGHT.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Electrical
Issued 23 May 2001 Resolved
INSULATE TERMINAL ON SPARE BATTERY IN ENGINE COMPARTMENT.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Documentation
Issued 8 July 1999 Resolved
Renew/place decal on Certificate of Documentation.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Documentation
Issued 8 July 1999 Resolved
Provide pre-employment drug testing of all crewmembers.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Documentation
Issued 8 July 1999 Resolved
Designate senior deck hand in writing.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Documentation
Issued 8 July 1999 Resolved
Provide proof all crew are in random drug testing program.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Lifesaving
Issued 8 July 1999 Resolved
Re-register EPIRB with NOAA.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Fire Fighting
Issued 8 July 1999 Resolved
Mark three buckets as "fire buckets"
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Fire Fighting
Issued 8 July 1999 Resolved
Mark/identify location for manual pull on fixed fire sys.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Fire Fighting
Issued 8 July 1999 Resolved
Post instructions to secure ventilation at pull station for fixed system._x001C_
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Lifesaving
Issued 8 July 1999 Resolved
Replace two adult life jackets.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Documentation
Issued 8 July 1999 Resolved
Provide trng log/safety equip log & make entries.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Accommodation/Occupational Safety
Issued 8 July 1999 Resolved
Close & lock MSD overboard valve
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Accommodation/Occupational Safety
Issued 8 July 1999 Resolved
Mark/tag MSD overboard valve "Do not open in US waters"
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Fire Fighting
Issued 11 March 1999 Resolved
OBTAIN & INSTALL MANUFACTURER'S REQUIRED EQUIPMENT FOR AUTOMATIC SHUT DOWN OF ENGINE UPON DISCHARGE OF FIRE SYSTEM.
Condition: Unknown
Due 12 April 1999
Resolved 25 September 1999
Lifesaving
Issued 17 June 1998 Resolved
SERVICE/REPACK LIFE RAFT @ APPROVED RAFT SERVICING CENTER.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Engineering
Issued 17 June 1998 Resolved
INSTALL INSULATING/LAGGING MATERIALS OVER PORT ENGINE EXHAUST MANIFOLD AND RISER PIPE TO THE TURBOCHARGER.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Deck/Cargo
Issued 17 June 1998 Resolved
COMPLETE REPAIRS TO ANCHOR WINDLASS & MOTOR, PROVE OPERATION.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Lifesaving
Issued 17 June 1998 Resolved
COMPLETE MINOR MODIFICATIONS TO NEW BOARDING/RETRIVAL LADDER, FOR A MORE STABLE MOUNTING BRACKET.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Documentation
Issued 20 May 1997 Resolved
PROVIDE RADIO SAFETY CERTIFICATE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Construction/Loadline
Issued 20 May 1997 Resolved
CHANGE HAILING PORT ON STERN OF VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Engineering
Issued 20 May 1997 Resolved
REPLACE BOTH FUEL VENT FLAME SCREENS. USE 30 X 30 MESH SCREEN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Accommodation/Occupational Safety
Issued 20 May 1997 Resolved
PROVIDE HOLDING CAPACITY OF MSD TANK TO MSO SAN FRANSICO IN ORDER TO VERIFYCORRECT SIZE.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Lifesaving
Issued 20 May 1997 Resolved
PROVIDE NEW BATTERY FOR EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Unknown
Issued 20 May 1997 Resolved
PROVIDE WRITTEN POLICY FOR POSTING OF PASSENGER LIST AND VOYAGE PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Lifesaving
Issued 20 May 1997 Resolved
PROVIDE LIFEJACKET DONNING PLACARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Electrical
Issued 20 May 1997 Resolved
USE UL LISTED WIRE CONNECTORS FOR ALL WIRE CONNECTION ON THE VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Documentation
Issued 6 February 1997 Resolved
AFTER SALE OF THE VESSEL NEW OWNER IS TO PROVIDE PROOF OF PROPER DOCUMENTATION PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Electrical
Issued 6 February 1997 Resolved
REMOVE HOUSEHOLD RECEPTICLE FROM THE MACHINERY SPACE AND INSTALL PROPER DRIPPROOF RECEPTICLES IAW NEW SUBCHAPTER T.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Electrical
Issued 6 February 1997 Resolved
REMOVE EXTENSION CORDS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Construction/Loadline
Issued 6 February 1997 Resolved
IN CENTER COMPARTMENT INSTALL DOUBLE HOSE CLAMPS ON ALL THROUGH HULL FITTINGS.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Electrical
Issued 6 February 1997 Resolved
REPAIR RECEPTICLE IN LOUNGE AREA STARBOARD SIDE FORWARD.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Electrical
Issued 6 February 1997 Resolved
REPAIR/PROPERLY INSULATE WIRING IN 12 VOLT SYSTEM WHERE EXPOSED. MAINLY LOCATED IN THE LOUNGE AREA.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Accommodation/Occupational Safety
Issued 6 February 1997 Resolved
REPAIR ALL LOOSE RAILINGS ON DECK.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Construction/Loadline
Issued 6 February 1997 Resolved
REPAIR CRACKED ENG. ROOM VENT LOCATED IN GUNWALE, STBD SIDE, JUST AFT OF DECK HOUSE.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Construction/Loadline
Issued 6 February 1997 Resolved
REPAIR 2 INCH OVERBOARD, PORTSIDE ENGINE ROOM IN WAY OF FWD BULKHEAD AND SIDE SHELL.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Construction/Loadline
Issued 6 February 1997 Resolved
COMPLETE REMOVAL OF STEEL GUARDS PRESENTLY INSTALLED OVER CHINE, PORT AND STBD.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Unknown
Issued 18 July 1995 Resolved
Paint vessel name on hull.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Documentation
Issued 18 July 1995 Resolved
Provide FCC radiotelephone operators permit.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Engineering
Issued 18 July 1995 Resolved
Make repairs to leak in shaft packing.
Condition: Unknown
Due 18 July 1995
Resolved 20 July 1995
Deck/Cargo
Issued 18 July 1995 Resolved
Remove fishing past prior to carrying passengers for hire.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Lifesaving
Issued 9 April 1992 Resolved
LABEL STOWAGE FOR CHILD PFD'S. PROPERLY LABEL NUMBER OF PFD'S PER STOWAGE AREA FOR ALL ONBOARD.
Condition: Unknown
Due 9 April 1992
Resolved 9 April 1992
Construction/Loadline
Issued 9 April 1992 Resolved
MAKE BILGE PIPING VALVE AFT OF COLLISION BULKHEAD OPERABLE.
Condition: Unknown
Due 9 April 1992
Resolved 9 April 1992
Electrical
Issued 9 April 1992 Resolved
REMOVE OR REPLACE HOUSEHOLD TYPE 110V ELEC WIRING THROUGHOUT THE VESSEL_x001C_ W/MARINE APPROVED STRANDED COPPER CABLE.
Condition: Unknown
Due 9 April 1992
Resolved 9 April 1992
Lifesaving
Issued 9 April 1992 Resolved
PROPERLY PAINT AND STENCIL LIFEFLOAT.
Condition: Unknown
Due 9 April 1992
Resolved 9 April 1992
Engineering
Issued 18 April 1991 Resolved
INSTALL BILGE SUCTION LINE W/PROPER SUCTION STRAINER IN SPACE FWD OF_x001C_ COLLISION BHD. TIE THIS LINE INTO BILGE MANIFOLD SYSTEM. INSTALL_x001C_ INSPECTION ACCESS IN SPACE FWD OF COLLISION BHD.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Construction/Loadline
Issued 18 April 1991 Resolved
SUBMIT PLANS FOR INSTALLATION OF STRUCTURE IN WAY OF EXHAUST PIPE, PLANS_x001C_ FOR BILGE SYSTEM TO DERRATE CHANGES AND PLANS FOR MODIFICATION TO CABIN.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Navigation
Issued 18 April 1991 Resolved
INSTALL TILLER ARM AND SHOW PROPER OPERATION OF STEERING SYSTEM.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Documentation
Issued 18 April 1991 Resolved
MAKE VESSEL READY FOR REINSPECTION.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Engineering
Issued 23 October 1990 Resolved
PROVIDE PLANS FOR THE NEW MAIN ENGINE INSTALLATION AND MODIFICATIONS MADE TO THE MAIN DECK.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Construction/Loadline
Issued 23 October 1990 Resolved
MAKE THE VESSEL AVAILABLE FOR A SIMPLIFIED STABILITY TEST.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Documentation
Issued 21 March 1990 Resolved
PROVIDE AND POST THE VESSEL'S FCC STATION LICENSE AND A MARINE RADIO OPERATOR PERMIT.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Construction/Loadline
Issued 24 April 1989 Resolved
MAKE ENGINE COMPARTMENT HATCH WATERTIGHT, TO COMPLY WITH 46 CFR 171.124.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Engineering
Issued 1 July 1988 Resolved
INSTALL FLAME IMPINGEMENT BOWL ON GLASS FUEL FILTER.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988
Fire Fighting
Issued 1 July 1988 Resolved
PROVIDE 3RD B-II FIRE EXTINGUISHER FOR GALLEY STOVE.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988
Unknown
Issued 1 July 1988 Resolved
PROVIDE CURRENT FCC CERTIFICATE.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988
Navigation
Issued 1 July 1988 Resolved
HYDROSTATICALLY TEST COMPRESSED AIR BOTTLE.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988
Construction/Loadline
Issued 20 May 1987 Resolved
REMOVE FURRING IN ENGINEROOM AS NEEDED, USING SOUND MARINE PRACTICE.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Navigation
Issued 20 May 1987 Resolved
REPLACE KOTTER PIN ON RUDDER POST STEERING LINK.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Documentation
Issued 17 March 1987 Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Unknown
Issued 20 March 1986 Resolved
PROVE SATISFACTORY OPERATION OF MECH BILGE PUMP.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Engineering
Issued 20 March 1986 Resolved
INSTALL FLAME PROTECTION AROUND EMERGENCY FUEL SHUT-OFF REMOTE VALVES
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Unknown
Issued 20 March 1986 Resolved
CONDUCT VESSEL UNDERWAY OPERATIONAL TEST.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Navigation
Issued 20 March 1986 Resolved
PROVE OPERATION OF BRIDGE ELECTRONICS.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Unknown
Issued 14 March 1985 Resolved
REMOVE PLASTIC SHEET FROM AROUND MAIN ENGINE ALTERNATORS AND STARTER.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Engineering
Issued 14 March 1985 Resolved
MAKE REMOTE FUEL SHUT-OFF VALVES ACCESSIBLE FROM OUTSIDE ENGINE COMPARTMENTWITH OUT HAVING TO REMOVE ENGINE HATCH FOR ACCESS.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Unknown
Issued 14 March 1985 Resolved
PROVIDE MEANS OF SECURING MSD THRU-HULL SEAVALVES WHILE IN U.S.WATERS (SUCHAS LOCK AND CHAIN OR REMOVE HANDLES)
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Electrical
Issued 14 March 1985 Resolved
REHANG ALL OVERHEAD ELECTRICAL CABLE RUNS WITH METAL STRAPS INSTEAD OF PRESENT PLASTIC STRAPS.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Engineering
Issued 14 March 1985 Resolved
INSTALL FLAME SCREEN/SHIELD ON PLASTIC FUEL FILTER BOWL IN ENGINE COMPART- MENT STARBOARD SIDE AFT.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Construction/Loadline
Issued 14 March 1985 Resolved
INSTALL KEEPER CHAIN/LINE ON HATCH TO LAZARETTE.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Construction/Loadline
Issued 14 March 1985 Resolved
MAKE ENGINE HATCH WEATHERTIGHT TO PREVENT WATER LEAKAGE ON MAIN ENGINES ELETRICAL COMPONENTS.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985

Casualty record · 3

4 December 2017Routine · role: Involved in a Marine Casualty · activity 6318034
25 October 2020Routine · role: Involved in a Marine Casualty · activity 7083639
23 August 2021Routine · role: Involved in a Marine Casualty · activity 7300600
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.