Records from 1997 to 2023. Most recent: inspection, 9 November 2023.
Inspection history · 36
9 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7823920
24 October 2023
PSC A · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7813374
17 August 2022
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7535009
2 August 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7522258
16 April 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7432114
25 January 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7385201
6 December 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7363025
23 July 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7265209
15 January 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7124090
12 July 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7004316
30 December 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6880452
2 July 2019
Deficiency Check · CCSSC Examination · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6732536
8 January 2019
MARPOL Annex VI Survey · CCSSC Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6606940
9 July 2018
ISPS II Exam · Ballast Water Examination · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6472621
11 January 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6336316
25 January 2012
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4231239
14 January 2010
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3663639
26 January 2009
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3399044
24 April 2008
Internal Structural Exam · Cargo Tank Internal · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3190613
2 May 2007
MTSA Verification · Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2920366
4 April 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2909397
29 March 2006
Examination of Repairs · Hull Examination · Internal Structural Exam · Cargo Tank Internal · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2611995
7 February 2005
MTSA Verification · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2288182
26 January 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1989802
9 April 2003
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1771143
3 March 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1760061
11 February 2002
Examination of Repairs · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1485530
20 November 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 138076
9 March 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362021
10 July 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1913
23 February 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376052
18 June 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 41253
4 March 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1455678
24 June 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 54497
6 March 1998
Initial Certification · Hull Examination · Inclining Experiment · Construction Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404552
17 September 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1109453
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2023
Resolved
Non-tank vessels may not operate upon the navigable waters of the U.S. unless in compliance with a vessel response plan. At time of inspection, vessel found without an approved vessel response plan.
33 cfr 155.5021(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 November 2023
Resolution: Vessel response plan has been submitted to NVDC and email from MSU Houma is allowing a one time transit.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 24 October 2023
Resolved
Line throwing appliances shall include not less than 4 projectiles and 4 lines. Vessel only had 2 line throwing appliances.
Solas 74 III/23
Action required: 10 - Deficiency Rectified
Resolved 24 October 2023
Resolution: Vessel rep brought 2 additional line throwing appliances onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 October 2023
Resolved
Each electrical installation shall assure safety of crew from electrical hazards. There is no generator interlock. STBD generator shutdown.
Solas 74 II-1/23
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2023
Resolution: Interlock has been installed on the generator switchboard.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 24 October 2023
Resolved
Lines shall be fitted with a standard discharge connection. Connection on stbd side needs to be reworked.
Marpol 1/13
Action required: 15 - Rectify deficiencies by next port
Resolved 13 November 2023
Resolution: Standard discharge connection has been reworked and found to be in compliance.
01 - Certificates & Documentation › 012 - Crew Certificates › Application for Endorsement by flagstate
Issued 24 October 2023
Resolved
All ships shall be sufficiently and efficiently manned. 3 crew members did not have a valid flag state endorsement or application.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2023
Resolution: 03 crew members that are missing flag state endorsements now have flag state endorsements.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 24 October 2023
Resolved
Portable radio apparatus did not have valid battery installations. one set of batteries was expired and leaves the radios with not battery back up.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2023
Resolution: All required batteries are now onboard.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 October 2023
Resolved
Where pipes, electrical cables are carried through watertight bulkheads, ensure watertightness of bulkheads. two penetrations in steering gear room must be resealed.
SOLAS II-1/13
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2023
Resolution: Penetrations in steering gear room have been resealed.
12 - Dangerous Goods › N/A - No Subsystem › Special requirement
Issued 2 August 2022
No resolution recorded
Unless otherwise specified, the following requirements shall govern the application of tables 54.1, 54.2 and 54.3 to both “on-deck” and “under-deck” stowage of dangerous goods… . Vessel’s DOC for Dangerous Goods requires them to follow 74 SOLAS (81 Cons.) Ch. II-2/54.3 which requires them to follow all special requirements listed in II-2/54. PSCOs observed that vessel does not have immediate availability of a supply of water from the fires main either by permanent pressurization or by suitably placed remote starting arrangements for the fire pumps.
74 SOLAS (81 Cons.) Ch. II-2/54.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 January 2021
Resolved
Liquids which give off dangerous vapors and flammable gases shall be stored in a well ventilated space... PSCO's identified excessive gasoline stores for the rescue boat in the deck locker with no ventilation.
CCSS Code 3.22.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 January 2021
Resolved 15 January 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 15 January 2021
Resolved
An emergency fire pump shall be an independently driven self-contained pump which is positioned in a safe place outside the engine room...the fixed exhaust piping system is wasted at the manifold causing a major exhaust leak into the space.
CCSS Code 3.3.10.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 10 February 2021
Resolution: Wasted manifold replaced. Deficiency rectified.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 15 January 2021
Resolved
Oil filtering equipment shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm...PSCOs could not complete operational test of system due to short cycling of pump for filtering equipment.
MARPOL Annex I/14.6
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 10 February 2021
Resolution: Vessel replaced three way OCM flush valve and cleaned the suction strainer. Deficiency rectified, technician report and flag attestation attached to activity.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 15 January 2021
Resolved
The position of the rudder, if power-operated, shall be indicated at the navigation bridge... when conducting steering test the team observing the steering gear observed 15-15 rudder range and the team on the bridge observed 20-20 on the rudder angle indicator. Team has reasonable doubt as to position of the rudder.
CCSS Code 2.33.8
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 10 February 2021
Resolution: Vessel conducted repairs to the emergency steering RAI, replacement gauge installed. Deficiency rectified, service report attached to activity.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 30 December 2019
Resolved
Every ship of 400 gross tonnage and above...shall carry a garbage management plan which theh crew shall follow. Vessel's garbage management plan could not be provided to PSCO for examination, however, vessel has certificate of approval for Garbage Management Plan.
MARPOL 73 Annex V/Reg. 9.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 December 2019
Resolved 30 December 2019
Resolution: Plan was printed by company and placed onboard the ship.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 July 2019
Resolved
In ships of 50m in length and over at least 02 lifebuous provided with self igniting lights shall also be provided with self activating smoke signals. Each of these lifebouys capable of quick release from navigation bridge where practicable or of the thowover type. lifebuoys required with smoke and light are designed as throwover type however their arraangement secured directly to the superstructure with railing 4 feet of seperation prevents smoke and light from being discharged when lifebuoys are thrown as designed. CSSC 4.12.3 16BC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 17 July 2019
Resolution: Recieved Flag report and training documentation for crew of the vessel on how to deploy smoke/light and lifebuoys from superstructure.
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 8 January 2019
Resolved
No person may operate a ship less than 400 gross tons unless it is fitted with a shore connection that meets the specifications of 155.430 or at least one adapter. Vessel did not have shore connection or adapter available.
33 CFR 155.420(a)(3)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 8 January 2019
Resolved 8 January 2019
Communications › Public Address System › Announcing Station
Issued 26 January 2009
Resolved
Install PA on Emergency Power
Due 11 February 2009
Resolved 18 February 2009
Lifesaving › Rescue Boat › Propulsion Engine
Issued 26 January 2009
Resolved
Maintain rescue boat and engine iaw manufacturers Instructions. Incorporate into Lifesaving maintenance record.
Due 26 February 2009
Resolved 18 February 2009
Documentation › Logs/Records › Logbook (official)
Issued 26 January 2009
Resolved
Make proper entries into vessel official logbook iaw 46 cfr 131.620. To be inspected next annual topside
Due 26 February 2009
Resolved 14 January 2010
Resolution: Proper entries made in official logbook.
Stability › Watertight Integrity › General
Issued 26 January 2009
Resolved
Perform preventive maintence on Port and Stbd WTD for storage lockers, Replace Main Deck WTD with proper seal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 26 January 2009
Resolved
Stencil Rescue Boat iaw Sub chapter "L"
Due 26 February 2009
Resolved 18 February 2009
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 January 2009
Resolved
Repair OWS and demonstrate proper operation
Action required: 705 - Other - as specified
Due 26 February 2009
Resolved 18 February 2009
Documentation › Logs/Records › Oil Record Book
Issued 26 January 2009
Resolved
Log OWS usage into Oil Record Book
Due 26 February 2009
Resolved 18 February 2009
Documentation
Issued 6 March 1998
Resolved
VESSEL TO SUBMIT TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS THE FIRE DETECTION AND ALARM SYSTEM DRAWING AS REQUIRED BY 46 CFR 91.55-5(d)(3).
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998