This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it931 - Displacement, Ton 398 - Convention (Subpart B), Gross Ton 972 - Regulatory (Subpart C or D), Gross Ton 291 - Convention (Subpart B), Net Ton 271 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 15 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
9 November 2023Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7823920
24 October 2023PSC A · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7813374
17 August 2022In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7535009
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2023Resolved
Non-tank vessels may not operate upon the navigable waters of the U.S. unless in compliance with a vessel response plan. At time of inspection, vessel found without an approved vessel response plan.
33 cfr 155.5021(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 November 2023
Resolution: Vessel response plan has been submitted to NVDC and email from MSU Houma is allowing a one time transit.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 24 October 2023Resolved
Line throwing appliances shall include not less than 4 projectiles and 4 lines. Vessel only had 2 line throwing appliances.
Solas 74 III/23
Action required: 10 - Deficiency Rectified
Resolved 24 October 2023
Resolution: Vessel rep brought 2 additional line throwing appliances onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 October 2023Resolved
Each electrical installation shall assure safety of crew from electrical hazards. There is no generator interlock. STBD generator shutdown.
Solas 74 II-1/23
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2023
Resolution: Interlock has been installed on the generator switchboard.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 24 October 2023Resolved
Lines shall be fitted with a standard discharge connection. Connection on stbd side needs to be reworked.
Marpol 1/13
Action required: 15 - Rectify deficiencies by next port
Resolved 13 November 2023
Resolution: Standard discharge connection has been reworked and found to be in compliance.
01 - Certificates & Documentation › 012 - Crew Certificates › Application for Endorsement by flagstate
Issued 24 October 2023Resolved
All ships shall be sufficiently and efficiently manned. 3 crew members did not have a valid flag state endorsement or application.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2023
Resolution: 03 crew members that are missing flag state endorsements now have flag state endorsements.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 24 October 2023Resolved
Portable radio apparatus did not have valid battery installations. one set of batteries was expired and leaves the radios with not battery back up.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2023
Resolution: All required batteries are now onboard.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 October 2023Resolved
Where pipes, electrical cables are carried through watertight bulkheads, ensure watertightness of bulkheads. two penetrations in steering gear room must be resealed.
SOLAS II-1/13
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2023
Resolution: Penetrations in steering gear room have been resealed.
12 - Dangerous Goods › N/A - No Subsystem › Special requirement
Issued 2 August 2022No resolution recorded
Unless otherwise specified, the following requirements shall govern the application of tables 54.1, 54.2 and 54.3 to both “on-deck” and “under-deck” stowage of dangerous goods… . Vessel’s DOC for Dangerous Goods requires them to follow 74 SOLAS (81 Cons.) Ch. II-2/54.3 which requires them to follow all special requirements listed in II-2/54. PSCOs observed that vessel does not have immediate availability of a supply of water from the fires main either by permanent pressurization or by suitably placed remote starting arrangements for the fire pumps.
74 SOLAS (81 Cons.) Ch. II-2/54.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 January 2021Resolved
Liquids which give off dangerous vapors and flammable gases shall be stored in a well ventilated space... PSCO's identified excessive gasoline stores for the rescue boat in the deck locker with no ventilation.
CCSS Code 3.22.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 January 2021
Resolved 15 January 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 15 January 2021Resolved
An emergency fire pump shall be an independently driven self-contained pump which is positioned in a safe place outside the engine room...the fixed exhaust piping system is wasted at the manifold causing a major exhaust leak into the space.
CCSS Code 3.3.10.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 10 February 2021
Resolution: Wasted manifold replaced. Deficiency rectified.
Oil filtering equipment shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm...PSCOs could not complete operational test of system due to short cycling of pump for filtering equipment.
MARPOL Annex I/14.6
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 10 February 2021
Resolution: Vessel replaced three way OCM flush valve and cleaned the suction strainer. Deficiency rectified, technician report and flag attestation attached to activity.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 15 January 2021Resolved
The position of the rudder, if power-operated, shall be indicated at the navigation bridge... when conducting steering test the team observing the steering gear observed 15-15 rudder range and the team on the bridge observed 20-20 on the rudder angle indicator. Team has reasonable doubt as to position of the rudder.
CCSS Code 2.33.8
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 10 February 2021
Resolution: Vessel conducted repairs to the emergency steering RAI, replacement gauge installed. Deficiency rectified, service report attached to activity.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 30 December 2019Resolved
Every ship of 400 gross tonnage and above...shall carry a garbage management plan which theh crew shall follow. Vessel's garbage management plan could not be provided to PSCO for examination, however, vessel has certificate of approval for Garbage Management Plan.
MARPOL 73 Annex V/Reg. 9.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 December 2019
Resolved 30 December 2019
Resolution: Plan was printed by company and placed onboard the ship.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 July 2019Resolved
In ships of 50m in length and over at least 02 lifebuous provided with self igniting lights shall also be provided with self activating smoke signals. Each of these lifebouys capable of quick release from navigation bridge where practicable or of the thowover type. lifebuoys required with smoke and light are designed as throwover type however their arraangement secured directly to the superstructure with railing 4 feet of seperation prevents smoke and light from being discharged when lifebuoys are thrown as designed. CSSC 4.12.3 16BC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 17 July 2019
Resolution: Recieved Flag report and training documentation for crew of the vessel on how to deploy smoke/light and lifebuoys from superstructure.
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 8 January 2019Resolved
No person may operate a ship less than 400 gross tons unless it is fitted with a shore connection that meets the specifications of 155.430 or at least one adapter. Vessel did not have shore connection or adapter available.
33 CFR 155.420(a)(3)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 8 January 2019
Resolved 8 January 2019
Recorded names · 1
CALVIN BAYNE (2003–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.