MAURY USCG vessel records Sign in
← All vessels

MAGNOLIA BELLE

MAGNOLIA BELLE is a 1969 passenger vessel (uninspected). The Coast Guard has recorded 47 inspections since 1985, most recently in July 2009, along with 119 deficiencies and 3 casualty investigations between 2004 and 2005.

Records from 1985 to 2009. Most recent: inspection, 9 July 2009.

Built
1969
Last inspected
9 July 2009
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2524
Flag
UNITED STATES
367116370 (licence lapsed)
Maury page id
psix-46320

Inspections, by type

…with no type recorded7
Years with a record 24 calendar years (1985–2009)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 20.0 ft × 5.0 ft
Registered tonnagegross 45 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDUBUQUE BOAT & BOILER CO. · DUBUQUE, IA, UNITED STATES · built 1969
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD2524MMSI 367116370 · expired · compulsorily equipped · granted 23 May 2006, cancelled 23 July 2016
WCX3906MMSI not assigned · expired · compulsorily equipped · granted 8 April 1997, cancelled 10 June 2007 · licensed under a name not among this hull’s recorded names (not shown)
WY7206MMSI not assigned · expired · compulsorily equipped · granted 25 May 1994, cancelled 25 July 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT WES GOSSETT Towing Vessel · MISLE 70971 · 16 April 2005 · activity 2344981

Inspection history · 47

9 July 2009 Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3528793
11 June 2008 DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3233821
6 September 2006 COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2769139
15 July 2005 Damage Survey
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2426426
10 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2443661
16 April 2005 Deadweight Survey · Damage Survey
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2337154
16 April 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2344981
22 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2150503
2 July 2004 COI Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2084981
3 February 2003 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1739105
5 December 2002 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1716306
19 September 2001 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1462262
18 June 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1068450
6 October 2000 Deficiency Check · Excursion Permit
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 822150
1 September 2000 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1373156
16 August 2000 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1403202
11 July 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 189400
11 July 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 768258
1 June 2000 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 820729
1 June 2000 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1462103
15 October 1999 Excursion Permit
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1123342
9 August 1999 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1413583
10 September 1998 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 800726
4 August 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1130668
17 June 1998 Excursion Permit
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1126720
10 June 1997 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1390298
11 April 1996 Re-Inspection · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1083636
31 May 1995 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1183447
31 March 1995 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1149187
11 May 1994 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 859737
19 April 1994 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 856069
5 May 1993 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 840964
4 May 1993 Examination of Repairs · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1447244
21 April 1993 Examination of Repairs · Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1141987
24 March 1993 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1420713
2 June 1992 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1254308
18 March 1992 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1011861
19 June 1991 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 904527
4 April 1991 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 998361
29 March 1991 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1304799
23 April 1990 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1215073
20 May 1989 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 893623
29 March 1988 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 992310
6 April 1987 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1328474
18 March 1986 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 994707
24 February 1986 Credit Drydock
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1297328
27 March 1985 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1288645

Deficiency record · 119

Construction/Loadline › Hull › Side Shell
Issued 18 June 2008 Resolved
Make proper repairs to small fracture iwo #2 void port side. Temp repair made by drill stopping and welding.
Action required: 705 - Other - as specified
Resolved 18 June 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 June 2008 Resolved
Properly remove all petroleum products form all bilges.
Action required: 705 - Other - as specified
Resolved 18 June 2008
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 June 2008 Resolved
Provide 25 seviceable adult lifejackets to carry the number of passengers on the COI.
Action required: 705 - Other - as specified
Resolved 18 June 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 11 June 2008 Resolved
Stow all unused items and make sanitary, galley area, dining room, bathrooms and all other spaces that passengers have access to..
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2008
Engineering › Electric Propulsion System › Circuit Board
Issued 11 June 2008 Resolved
Repair/ replace generator run light on power panel. Light not operating.
Action required: 705 - Other - as specified
Resolved 11 June 2008
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 6 September 2006 Resolved
Remove all flammable liquids from vessel in way of numerous paint and gas cans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Flammables removed from vessel.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 September 2006 Resolved
Stencil all PFD lockers with amount and size of PFD's enclosed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 September 2006 Resolved
Prove proper operation of bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 6 September 2006 Resolved
Provide documentation that all crewmembers are covered under the same chemical testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Communications › Audible Communications › SPD (Other)
Issued 6 September 2006 Resolved
Prove proper operation of the PA system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 September 2006 Resolved
Renew stern light lens and secure loose bulb inside.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 September 2006 Resolved
Properly mount side navigation lights as per NavRules.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2006
Lifesaving › Hand Flares › Quantity
Issued 6 September 2006 Resolved
Provide 2 additional orange smoke or 2 red hand flares onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 September 2006 Resolved
Conduct all 3 emergency drills underway to the satisfaction of the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Drills conducted satisfactory prior to passenger being carried.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 6 September 2006 Resolved
Provide retroreflective material for all identified PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 September 2006 Resolved
Clean vessel passenger areas, remove rubbish, dirt and make sanitary the seating areas.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: All passenger areas scrubbed with bleach solution and/ or painted.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 September 2006 Resolved
Mark name of vessel and provide retroreflective tape on the bow ring bouy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2006
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Silencer (exhaust)
Issued 6 September 2006 Resolved
Insulate area of exposed exhaust piping on the generator.
Due 6 October 2006
Resolved 22 September 2006
Engineering › Steering Gear System › Trunnion Block
Issued 6 September 2006 Resolved
PROPERLY REPAIR WASTED PORT AND STARBOARD FLANKING RUDDER QUADRANTS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2006
Electrical › Electric Supply System (service) › Cable
Issued 6 September 2006 Resolved
PROPERLY SUPPORT LOOSE WIRING UNDER BRIDGE CONSOLE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2006
Engineering › Bilge Water Management System › Pump
Issued 6 September 2006 Resolved
PROVIDE A 25 GPM BILGE PUMP ONBOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Engineering › Bilge Water Management System › Pump
Issued 6 September 2006 Resolved
PROVIDE A PORTABLE BILGE PUMP ONBOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: A portable bilge pump was placed on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 September 2006 Resolved
PROVIDE A COMPLETE COAST GUARD APPROVED FIRST AID KIT OR EQUIVALENT ONBOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 September 2006 Resolved
PROVIDE PROPER SCREW POST BATTERY FOR THE RING BOUY FLOAT LIGHT.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Electrical › Electric Supply System (service) › Battery Charger
Issued 6 September 2006 Resolved
REMOVE OLD BATTERY CHARGER WIRING AND PERMANENTLY INSTALL NEW CHARGER.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 September 2006 Resolved
REPAIR GENERATOR BATTERY BOX.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 September 2006 Resolved
LEVEL ALL BATTERIES IN THE MAIN SERVICE BATTERY BOX.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Personnel › Training › First Aid/CPR
Issued 6 September 2006 Resolved
Obtain Red Cross First Aid/ CPR cards for 50% of crew IAW NVIC 1-91.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Two crewmembers provided proof of Red Cross first aid and CPR training.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 6 September 2006 Resolved
Provide that retro reflective tape recently applied to PFDs is type I per 46 CFR 185.604(h).
Condition: Unknown
Due 2 November 2006
Resolved 18 June 2008
Resolution: New life jackets onboard.
Construction/Loadline › Structures › Machinery Space Opening
Issued 6 September 2006 Resolved
Prove that the aft two watertight doors are water tight and operating as intended. Properly adjust dogs and properly install wedges.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Water tight doors adjusted and tested satisfactory.
Engineering › Fuel Oil Service System › Piping
Issued 6 September 2006 Resolved
Install proper brackets for fuel lines in engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Brackets installed for fuel lines.
Engineering › Steering Gear System › Valve, Control
Issued 6 September 2006 Resolved
Correct hydraulic leak above battery box aft bulkhead of engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Leak corrected.
Fire Fighting › Fire Pumps › Arrangement
Issued 6 September 2006 Resolved
Properly mount fire pump, pump should not be supported by fire main piping. Vessel allowed to make temporary mount out of wood for tall stacks event. Vessel shall have a metal mount fabricated prior to carry passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2008
Resolution: Fire pump mounted on metal welded frame.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 September 2006 Resolved
Properly label all PFD storage areas IAW 46 CFR 185.604(f).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: PFD storage areas labeled.
Electrical › Electric Supply System (service) › Cable
Issued 6 September 2006 Resolved
Prove that the wiring used to wire up bilge alarms meets the requirements of 46 CFR 183.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 November 2006
Resolved 18 June 2008
Resolution: Wiring meets UL requirements.
Engineering › Freshwater System (cylinder head cooling) › Sensor
Issued 6 September 2006 Resolved
Prove that propulsion engine water temperature gauges work IAW 46 CFR 182.20-5(b) "old T".
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Operator found loose connection on sensors both appeared to be in working order.
Electrical › Electric Supply System (service) › Cable
Issued 6 September 2006 Resolved
Remove twist on type electrical connectors located in the open under console in pilot house and near generator in engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Twist type connectors removed and butt connectors installed.
Engineering › Steering Gear System › Piping
Issued 6 September 2006 Resolved
Secure/ close hole located port side of hydraulic oil tank. If vent should vent out side of space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2006
Resolution: Plug installed.
Engineering › Lubricating Oil Service System › Valve, Control
Issued 16 April 2005 Resolved
Prior to getting underway thoroughly inspect and troubleshoot the hydraulic system and make necessary repairs.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 20 April 2005
Resolution: System was inspected, repaired and tested by a local hydraulic specialist. Also the attending Marine Inspector conducted sea to ensure that the system worked properly, results were sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 16 April 2005 Resolved
Prior to getting underway clean and remove all oil hazards from the machinery. Machinery space has an excess amount of oil in the containment areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 April 2005
Resolution: Oli hazard were being removed from the Machinery spaces.
Electrical › Electric Supply System (service) › Cable
Issued 16 April 2005 Resolved
Properly install water pump junction box in the machinery space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 3 October 2006
Resolution: Junction box installed.
Engineering › Lubricating Oil Service System › Pump Prime Mover
Issued 16 April 2005 Resolved
Locate machinery equipment leaks and continue the removal of oil hazards from the machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 3 October 2006
Resolution: Oil hazards removed from engine room and bilges cleaned.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 16 April 2005 Resolved
Main propulsion engine shaft guard is missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 3 October 2006
Resolution: Shaft guard installed.
Operations/Management › Passenger Operations
Issued 5 December 2002 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS HAVE VESSEL ATTENDED BY USCG CONGNIZANT [name withheld], WITH REQUIRED CREW TO CONDUCT EMERGENCY DRILLS.
Action required: 705 - Other - as specified
Resolved 3 February 2003
Resolution: 3 FEB03: Vessels Owner went out of business and vessel was placed in lay-up status pending bankrupsty and sale auction. Vessel''s COI was removed and deactivated this date.
Electrical
Issued 19 September 2001 Resolved
Reattach electric j-box and ensure cable is properly protected
Condition: Unknown
Due 26 September 2001
Resolved 19 September 2001
Construction/Loadline
Issued 19 September 2001 Resolved
Repair dogs on Water tight doors (WTD)leading to engine room.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Deck/Cargo
Issued 19 September 2001 Resolved
Attach machinery guard on main engine.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Fire Fighting
Issued 19 September 2001 Resolved
Provide proper bracket for fire extinguisher by remote switch for fire pump.
Condition: Unknown
Due 26 September 2001
Resolved 27 September 2001
Engineering
Issued 19 September 2001 Resolved
Repair hydraulic leak in engine room.
Condition: Unknown
Due 26 September 2001
Resolved 27 September 2001
Documentation
Issued 19 September 2001 Resolved
Provide passenger count plan.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Navigation
Issued 19 September 2001 Resolved
Provide navigation pub/charts.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Construction/Loadline
Issued 19 September 2001 Resolved
Complete permanent wiring of forward compartment and engineroom high level bilge alarm and demo operation and label bilge manifold valves.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Engineering
Issued 19 September 2001 Resolved
Label location for emergency fuel shut off valve.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Documentation
Issued 19 September 2001 Resolved
Provide documentation for compliance with Federal Drug testing regulation.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Lifesaving
Issued 19 September 2001 Resolved
Provide CPR/First aid card for 50% of crew.
Condition: Unknown
Due 26 September 2001
Resolved 27 September 2001
Documentation
Issued 19 September 2001 Resolved
Post page two of COI.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Electrical
Issued 19 September 2001 Resolved
Repair emergency lighting on vessel.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Fire Fighting
Issued 19 September 2001 Resolved
Provide 50 foot fire hose and with attach nozzle on vessel.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Lifesaving
Issued 19 September 2001 Resolved
Renew (39) thirty nine adult and (5) five children life preservers and apply retro reflective tape.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Electrical
Issued 19 September 2001 Resolved
Install globes and guards on lighting fixtures throughout vessel.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Construction/Loadline
Issued 19 September 2001 Resolved
Replace/repair manhole cover and capture chain for forepeak.
Condition: Unknown
Due 26 September 2001
Resolved 27 September 2001
Accommodation/Occupational Safety
Issued 19 September 2001 Resolved
Secure MSD overboard valve.
Condition: Unknown
Due 27 September 2001
Resolved 31 October 2001
Navigation
Issued 1 September 2000 Resolved
Replace universal joint in steering system in way of kitchen counter overhead. Until it is renewed, the Master shall inspect the coupling prior_x001C_to each voyage.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Documentation
Issued 1 September 2000 Resolved
Create Passenger Safety Brief and Drill Log.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Lifesaving
Issued 1 September 2000 Resolved
Make PFD storage and quantity markings more noticeable.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Documentation
Issued 1 September 2000 Resolved
POST REQUIRED DOCUMENTS, CAPTAIN'S LICENSE, GARBAGE PLACARDS, STABILITY LTR, PFD DONNING INST.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Fire Fighting
Issued 1 September 2000 Resolved
RECHARGE OR REPLACE BII FIRE EXTINGUISHER IN WAY OF PILOT HOUSE ENTRANCE.
Condition: Unknown
Due 7 September 2000
Resolved 7 September 2000
Documentation
Issued 1 September 2000 Resolved
Establish a contract with an approved drug testing consortium and provide documentation.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Fire Fighting
Issued 1 September 2000 Resolved
Make access to engineroom vent more accessible.
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Lifesaving
Issued 1 September 2000 Resolved
Provide portable communication capabilities for the crew to the pilot houseduring times of emergency.
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Documentation
Issued 1 September 2000 Resolved
Provide documentation that 50% of the crew has current CPR and First Aid _x001C_ training.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Construction/Loadline
Issued 9 August 1999 Resolved
INSTALL/SHOW PROPER OPERATION OF HIGH LVL BILGE ALARM SYSTEM IAW APPROVED PLANS DTD 16MAR99.
Condition: Unknown
Due 16 August 1999
Resolved 17 August 1999
Engineering
Issued 4 August 1998 Resolved
REPAIR/REPLACE PILOT HOUSE CONTROL ACTUATOR FOR PADLE WHEEL RPM, FWD OF GENERATOR.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Engineering
Issued 4 August 1998 Resolved
REPLACE CHAFFED HYDRAULIC PILOT LINE ON EMERGENCY HYDRAULIC PROPULSION ON GENERATOR.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Construction/Loadline
Issued 4 August 1998 Resolved
MAKE FWD COLLISION COMPT. HATCH WATERTIGHT OR REPLACE WITH A NEW HATCH.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Electrical
Issued 4 August 1998 Resolved
REPLACE/REPAIR EMERGENCY LIGHT IN SALO THAT IS OOC.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Navigation
Issued 4 August 1998 Resolved
FREE UP/ GREASE OR REPLACE P&S AFT STEERING BLOCKS FOR STEERING RUDDERS, PULLEYS ARE FROZEN.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Lifesaving
Issued 4 August 1998 Resolved
SEGREGATE & LABEL CHILDRENS LIFE JACKETS.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Lifesaving
Issued 4 August 1998 Resolved
MAKE/PROVIDE SWIMMER RECOVERY PLATFORM/LADDER.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Lifesaving
Issued 4 August 1998 Resolved
VESSEL IS REQUIRED 165 ADULT LIFE JACKETS, ONLY 161 ON BOARD. VESSEL IS RESTRICTED TO THE CARRIAGE OF 161 ADULT PERSONS UNTIL THE MISSING 04 LIFE JACKETS ARE REPLACED.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Engineering
Issued 10 June 1997 Resolved
REPLACE/REPAIR LAGGING ON MAIN ENG TO COVER EXPOSED EXHAUST PIPING.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Accommodation/Occupational Safety
Issued 10 June 1997 Resolved
PROVIDE SECURE STORAGE FOR ITEMS TO BE STORED IN THE SEWAGE COMPT.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Navigation
Issued 10 June 1997 Resolved
DEMONSTRATE PROPER OPERATION OF RADAR.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Navigation
Issued 10 June 1997 Resolved
REWIRE STERN [name withheld] CIRCUIT, DEMONSTRATE PROPER OPERATION OF NAV LTS.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Accommodation/Occupational Safety
Issued 10 June 1997 Resolved
DEMONSTRATE PROPER OPERATION OF AIR SYSTEM PRESSURE RELIEF VALVES.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Accommodation/Occupational Safety
Issued 10 June 1997 Resolved
INSTALL PROPER SCREEN IN POTABLE WATER TANK VENT.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Documentation
Issued 10 June 1997 Resolved
PROVIDE/OBTAIN RADIO STATION LICENSE & DISPLAY SAME IN PILOT HOUSE.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Documentation
Issued 10 June 1997 Resolved
PROVIDE/OBTAIN RADIO OPERATORS LICENSE & DISPLAY SAME IN PILOT HOUSE.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Engineering
Issued 10 June 1997 Resolved
PROVIDE ON BOARD VSL A GRADUATED FUEL SOUNDING ROD & CORRESPONDING CHART.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Accommodation/Occupational Safety
Issued 10 June 1997 Resolved
REPLACE 125 SPI RELIEF VALVE ON HOT WATER HEATER WITH VALVE =< 100 PSI/210 DEG F.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Documentation
Issued 10 June 1997 Resolved
PROVIDE PROPER DOCUMENTATION OF COMPANIES ENROLLMENT IN A DRUG PROGRAM.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Construction/Loadline
Issued 10 June 1997 Resolved
REPLACE/REPAIR AFT VOID HATCH TO ORIGINAL WORKING CONDITION.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Accommodation/Occupational Safety
Issued 10 June 1997 Resolved
REMOVE ALL PLASTIC TRASH CANS FROM VESSEL.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Construction/Loadline
Issued 10 June 1997 Resolved
REPLACE/REPAIR FWD VOID ACCESS HATCH TO ORIGINAL WORKING CONDITION.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Engineering
Issued 10 June 1997 Resolved
REPLACE/REPAIR LAGGING ON GEN TO COVER EXPOSED EXHAUST PIPING.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Electrical
Issued 10 June 1997 Resolved
REMOVE OR INSTALL A PROPERLY PROTECTED LIGHT ON THE GEN DIST BOARD.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Fire Fighting
Issued 31 March 1995 Resolved
INSTALL STRUCTURAL FIRE PROTECTION PER 46 CFR 72.05._x001C_ UNTIL COMPLETED, PASSENGER COUNT IS REDUCED TO NOT MORE THAN 150 PASSENGERS.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Construction/Loadline
Issued 31 March 1995 Resolved
REMOVE PLASTIC COVERS FROM THE PORT AND STARBOARD WEATHER DECK OR PROVE THAT STABILITY IS UNEFFECTED.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Construction/Loadline
Issued 19 April 1994 Resolved
CROP AND RENEW WASTED BULKHEADS IN WOMENS RESTROOM AT SINK, BEHIND TOILET AND IN CLOSET.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Construction/Loadline
Issued 19 April 1994 Resolved
CROP AND RENEW WASTED BULKHEAD IN MENS RESTROOM AT SINK AND BEHIND TOILET.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Construction/Loadline
Issued 19 April 1994 Resolved
CROP AND RENEW WASTED DECK IN MENS RESTROOM.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Lifesaving
Issued 19 April 1994 Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY TESTING AND DRILLS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Construction/Loadline
Issued 21 April 1993 Resolved
MAKE PERMANENT REPAIRS TO THE SATISFACTION OF THE COGNIZANT OCMI TO BOTTOM PLATE AT PORT CHINE IN WAY OF AFT TWO FRAME SPACES IN COMPARTMENT FORWARD OF ENGINE ROOM. TO BE COMPLETED NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Construction/Loadline
Issued 21 April 1993 Resolved
PERFORM AND MAINTAIN SATISFACTORY TEMPORARY REPAIR TO HOLED BOTTOM PLATE INWAY OF #1 AND # 2 TRANSVERSE FRAMES AND PORT CHINE IN COMPARTMENT FORWARD OF ENGINE ROOM.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Accommodation/Occupational Safety
Issued 24 March 1993 Resolved
PROCURE & INSTALL MARPOL ANNEX V PLACARD REQUIRED BY 33 CFR 151.59.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Lifesaving
Issued 24 March 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Electrical
Issued 18 March 1992 Resolved
REPAIR FRAYED ELECTRICAL CORD ON FAN LOCATED ON THE O1 DECK, AS REQUIRED BY46 C.F.R. 183.10-20, NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Electrical
Issued 18 March 1992 Resolved
RE-ANCHOR THE ELECTRICAL WIRING LEADING INTO RECEPTACLE ON THE AFT BULKHEADON THE 01 DECK, AS REQUIRED BY 46 C.F.R. 183.10-20, NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Construction/Loadline
Issued 18 March 1992 Resolved
DEMONSTRATE THE SATISFACTORY OPERATION OF THE BILGE SYSTEM, AS REQUIRED BY 46 C.F.R. 176.25-10(A)(7), NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Electrical
Issued 18 March 1992 Resolved
REPLACE LID ON BATTERY BOX IN ENGINE ROOM, AS REQUIRED BY 46 C.F.R 183.05- 20(A), NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Engineering
Issued 18 March 1992 Resolved
MARK THE LOCATION OF THE FUEL SHUT-OFF FITTING ON THE MAIN DECK, AS REQUIRED BY 46 C.F.R. 185.30-20, NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Construction/Loadline
Issued 18 March 1992 Resolved
REMOVE PAINT FROM THE KNIFE EDGES AND GASKETS OF THE WATERTIGHT DOORS IN THE ENGINE ROOM, AS REQUIRED BY 46 C.F.R. 171.114, NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Construction/Loadline
Issued 18 March 1992 Resolved
REMOUNT BILGE PIPING IN VICINITY OF WATERTIGHT DOOR IN FUEL SPACE TO_x001C_ CLEAR WATERTIGHT DOOR, WITHOUT THE DOOR RUBBING AGAINST THE PIPING, AS REQUIRED BY 46 C.F.R. 171.114, NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Lifesaving
Issued 18 March 1992 Resolved
REPLACE WORN BECKETS (STRAPS) ON ALL LIFERINGS, AS REQUIRED BY 46 C.F.R._x001C_ 180.30-10(A) AND 46 C.F.R. 160.050-4(D), NO LATER THAN THE COMPLIANCE DATE._x001C_
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Lifesaving
Issued 18 March 1992 Resolved
PERMANENTLY ATTACH WATERLIGHT BRACKET NEXT TO LIFERING ON THE BRIDGE AS REQUIRED BY 46 CFR 180.30-10(C), NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Lifesaving
Issued 4 April 1991 Resolved
Provide seven adult PFD's prior to compliance date; until PFD's are aboard,the total persons allowed is reduced to 221.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991 Resolved
Repair latches on PFD storage compartments in the port and starboard heads on the main deck prior to compliance date.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 20 May 1989 Resolved
PROVIDE 5 ADULT LIFE PRESERVERS ON BOARD PRIOR TO THE COMPLIANCE DATE. THE TOTAL NUMBER OF PERSONS ABOARD IS RESTRICTED TO 223 UNTIL LIFE PRESERVERS ARE ON BOARD.
Condition: Unknown
Due 20 May 1989
Resolved 20 May 1989
Lifesaving
Issued 20 May 1989 Resolved
PROVIDE 6 ORANGE SMOKE AND 6 RED FLARE APPROVED HAND HELD DISTRESS SIGNALS PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 20 May 1989
Resolved 20 May 1989

Casualty record · 3

22 July 2004Routine · role: Involved in a Marine Casualty · activity 2150503
16 April 2005Routine · role: Involved in a Marine Casualty · activity 2344981
10 July 2005Routine · role: Involved in a Marine Casualty · activity 2443661
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.