Records from 1985 to 2025. Most recent: inspection, 8 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 67
8 September 2025
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8145428
11 October 2023
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7791300
1 September 2023
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7782522
12 June 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7684778
3 October 2022
Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7577646
10 August 2021
Administrative Inspection · COI Inspection · Hull Examination · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7284690
5 August 2020
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7023938
19 June 2019
Simplified Stability Test · Plan Review "T" Boat · In-Service Inspection · Damage Survey · Examination of Repairs · Hull Examination · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6717470
29 April 2019
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6667762
22 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6393092
25 August 2017
Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6251417
27 January 2017
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6078539
18 July 2016
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5944456
5 August 2015
Examination of Repairs · Annual Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5206686
21 March 2014
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4821979
17 February 2010
Annual Inspection · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3682209
27 February 2009
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3424948
24 April 2008
Re-Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3191310
28 February 2007
COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2879329
28 July 2006
Type not recorded
No type recorded · Station Merrimac River · USCG Northeast District (CGD-NE) · Activity 2729542
10 April 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2620900
13 April 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2333905
22 February 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2296644
1 April 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2035469
17 February 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2007617
11 April 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1773273
4 April 2002
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1600918
15 February 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1486840
12 April 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1429526
26 February 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1415553
24 April 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1421852
15 February 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1451508
15 April 1999
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 800573
17 March 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 808775
19 February 1999
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1129640
21 April 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 789595
13 April 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 77084
12 February 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 776593
17 April 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1106281
20 February 1997
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1107307
22 April 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1085935
12 February 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1187858
20 April 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 861453
14 February 1995
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 846618
16 May 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 859754
25 April 1994
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858252
28 March 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1166428
22 April 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 834241
9 February 1993
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 829366
9 April 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 954928
24 February 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1263580
26 March 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 904484
26 March 1991
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 916850
1 March 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 927891
8 February 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1213916
28 March 1990
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 980997
9 February 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 902913
30 March 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1042583
3 February 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1044736
5 April 1988
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1198963
4 February 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1017281
16 April 1987
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1329877
27 March 1987
Hull Examination · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1000428
27 March 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1305459
18 February 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1294773
27 March 1985
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 979765
8 March 1985
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1286955
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 September 2025
No resolution recorded
The owner shall make the vessel available for drydock examinations. The following worklist items shall be rectified prior to receiving credit drydock:
1)u/w hull -fwd bow- repair fractured glass on stem
2) u/w hull renew wasted sincs (6) on steel channel (3P/3S), both shafts (2), both rudders (4)
3) aft laz remove and renew rotten wood in way of rudder blocks port & stbd
4)tank compartment - stbd side wasted exhaust fix leak
5) engine room stbd outboard of main engine remoe and renew rotten planks to good material *save all removed fasteners
6)tighten bathrom seasuction valve (port side)
7) remove and cap excessive pipe on stbd side fwd head suction
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 September 2023
Resolved
The owner or managing operator shall make a vessel available for drydock examinations and internal structure examinations for certification.
Vessel has lapsed the drydock and internal structure exam expiration dates, 31AUG2023, on its COI.
Allow inspection for satisfactory drydock and internal structure exam credit prior to the carraige of passengers.
46CFR176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2023
Resolution: Vessel completed satisfactory hull inspection and internal structure exam for credit dry dock.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 March 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency.
Marine Inspector identified a proud plank in the #2 forward compartment on the starboard side, estimated 7 planks above the keel and below the waterline. Plank is found inset 3/8" and inspector is unable to verify if the original plank construction provides this inset or if the butt end of the plank is pulling the fastener out of the transverse frame. The two sandwiched white oak pieces that make up the transverse frame were found separated at the location of the proud plank butt end.
The vessel is restricted to a Lakes, Bays, and Sounds route until proper repairs are completed to the satisfaction of the attending marine inspector.
46 CFR 176.700
Action required: 705 - Other - as specified
Due 16 March 2022
Resolved 14 October 2022
Resolution: Plank renewed. See documents for repair proposal and photos.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 March 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency.
Identified an improper repair to the port rudder post support. The wood around the rudder post support securing bolt was found decayed and the owner repaired a 5" diameter 4" deep area of wood with epoxy around the securing bolt.
Crop and renew the wood as original.
46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 16 April 2022
Resolution: Wood cropped and renewed via scarf with in kin-peice using expoxy to seal.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 August 2021
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the three months before or after each anniversary date.
Vessel is greater than three months past the anniversary date.
Complete all required inspections prior to carriage of passengers.
46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2021
Resolved 16 March 2022
Resolution: Completed COI and credit DD/ISE.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 August 2020
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. The 25 person life float's 2 inch woven straps around the body of the life float were sun damaged and broke under tension. Repair or replace as original with approved material from the life float manufacturer in accordance with 46CFR160.027. Vessel restricted to 3 NM from shore.
46 CFR 185.700
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 14 August 2020
Resolution: Life float 2 inch woven straps replaced and confirmed to meet standards found in 46 CFR 160.027.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 August 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. All perishable items in the on-board first aid kit were past their expiration date. Replace as original.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 14 August 2020
Resolution: First Aid Kit replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 5 August 2020
Resolved
Internal combustion engine exhausts must be kept clear of and suitably insulated from combustible material. The Port Engine's exhaust lagging was fallen off. Insulate exhaust pipe prior to cooling water entering piping.
46 CFR 177.405(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 14 August 2020
Resolution: Insulation placed on exhaust piping prior to water cooled section.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 August 2020
Resolved
Whenever damage or deterioration to the hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may... require the vessel to... effect permanent repairs. During the internal inspection of the vessel the following areas were found to have structural damage due to different forms of rot. Prior to conducting repairs, submit a repair proposal following NVIC 7-95 in accordance with 46 CFR 176.700 for approval from the OCMI.
-Transverse under-deck frame in lazarette, port side rotted with fasteners completely exposed.
-Deck plywood in mid-hull hold (forward of lazarette), below storage locker, port side, found with crack in the deck and water leaking into hold.
-Transverse rib stiffeners, port side engine room, outboard of port main engine, found with severe rot in multiple adjacent frames.
46 CFR 176.600(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 14 August 2020
Resolution: Repair details under document section of activity. Transverse under-deck frame in lazarette, port side replaced and scarfed in to place, Deck plywood replaced in kind, sister rib stiffeners in the port side engine room outboard of main engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 May 2019
Resolved
Operator installed a gasoline powered generator and a/c unit on the upper deck without appoval of the cognizant [name withheld] unapproved gasoline generator installation prior to operation with passengers. 46 CFR 176.700(a)(b)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2019
Resolution: Operator removed generator from vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 April 2019
Resolved
A hatch exposed to the weather must be watertight.
make repairs to three watertight hatches as identified on the main deck and prove proper operation prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2019
Resolution: Operator repaired hatches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019
Resolved
Piping used in a vital system must: Be composed of ferrous aterials except when: Nonmetallic piping materials are permitted by §182.720; or Nonferrous metallic piping materials are permitted by §182.730.
Replace unapproved flex hose installed in engine water cooling exhaust line and in bilge piping as identified, with approved flex hose to the satisfaction of the attending Marine Inspector. 46 CFR 182.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 30 April 2019
Resolution: Operator replaced flex hose with approved type.
Engineering › Bilge Water Management System › Valve
Issued 22 May 2018
Resolved
Install positive shut-off valves servicing electrical submersible pumps in steering gear, fuel tank, and wheel house compartments. 46 CFR 182.530(e)(7)
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Operator installed ball valves as required.
Lifesaving › Lifebuoys › Approval
Issued 22 May 2018
Resolved
11117 - Replace life ring buoy with one approved IAW 160.050 and not less than 24 inches in diameter. 46 CFR 180.70(a)(3)
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Operator installed new approved 24 inch life ring buoy.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 July 2016
Resolved
Repair or replace holed exhaust piping on port and starboard main engines.
Due 1 August 2016
Resolved 18 July 2016
Resolution: Operator installed a coupling around the pipe and secured with hose clamps. Operator plans to replace exhaust piping at next dry dock.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 July 2016
Resolved
Prove radio can display position in latitude and longitude for DSC.
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 13 August 2016
Resolution: Operator connected GPS to the VHF radio. Verified GPS input.
Engineering › Sea-water System (primary cooling) › Valve
Issued 6 August 2015
Resolved
Demonstrate proper operation of steering compartment gate valve. 46 CFR 176.610 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2015
Resolution: Complete
Construction/Loadline › Hull › Bottom Plating
Issued 5 August 2015
Resolved
Repair/renew all affected areas of water borne organism damage on the hull planking to the satisfaction of the attending marine inspector. 46 CFR 176.610 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2015
Resolution: Repairs complete.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 24 April 2008
Resolved
Fixed Gas extinguishing system did not shut engine down as required due to corrosion and loose wiring on MDE terminals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 24 April 2008
Resolution: Wires cleaned and tightened,
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 February 2007
Resolved
Conduct u/w drills prior to carrying passengers
Action required: 705 - Other - as specified
Due 28 February 2007
Resolved 30 April 2007
Resolution: Conducted u/w drills
Lifesaving
Issued 19 February 1999
Resolved
THREE LIFE PRESERVERS REJECTED FOR ROTTEN FABRIC. PROVIDE THREE SERVICABLELIFE PRESERVERS FOR A TOTAL OF 51 ADULT LIFE PRESERVERS ON BOARD._x001C_
Condition: Unknown
Due 19 February 1999
Resolved 19 February 1999
Construction/Loadline
Issued 12 February 1998
Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY INTERNAL STRUCTURAL EXAMINATION PRIOR TOCARRYING PASSENGERS FOR HIRE AND NO LATER THAN 1 MAY 98.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Documentation
Issued 17 April 1997
Resolved
PROVIDE DOCUMENTATION OF PARTICIPATION IN AN APPROVED RANDOM DRUG TESTING PROGRAM OR CONSORTIUM.
Condition: Unknown
Due 24 April 1997
Resolved 25 April 1997
Engineering
Issued 25 April 1994
Resolved
INSTALL EXHAUST LAGGING IN WAY OF BOTH MAIN ENGINE EXHAUST PIPES FROM EXHAUST MANIFOLD TO AREA WHERE EXHAUST COOLING LINE ENTERS EXHAUST PIPE.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994