MAURY USCG vessel records
← All vessels

KOKOMO

Built
1969
Last inspected
8 September 2025
Documentation
Case Pending · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 September 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH6849
Flag
UNITED STATES
Maury page id
psix-46332

Documentation record

Registered dimensions (L × B × D)55.0 ft × 17.6 ft × 4.8 ft
Registered tonnagegross 37 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUTHWEST BOAT CORPORATION · SOUTHWEST HARBOR, ME, UNITED STATES · built 1969
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Endorsements, as the file codes themcw_un, fi
DocumentationCase Pending · issued 24 March 2025 · expires 31 March 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

8 September 2025 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8145428
11 October 2023 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7791300
1 September 2023 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7782522
12 June 2023 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7684778
3 October 2022 Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7577646
10 August 2021 Administrative Inspection · COI Inspection · Hull Examination · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7284690
5 August 2020 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7023938
19 June 2019 Simplified Stability Test · Plan Review "T" Boat · In-Service Inspection · Damage Survey · Examination of Repairs · Hull Examination · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6717470
29 April 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6667762
22 May 2018 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6393092
25 August 2017 Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6251417
27 January 2017 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6078539
18 July 2016 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5944456

Deficiency record · 16

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 September 2025 No resolution recorded
The owner shall make the vessel available for drydock examinations. The following worklist items shall be rectified prior to receiving credit drydock: 1)u/w hull -fwd bow- repair fractured glass on stem 2) u/w hull renew wasted sincs (6) on steel channel (3P/3S), both shafts (2), both rudders (4) 3) aft laz remove and renew rotten wood in way of rudder blocks port & stbd 4)tank compartment - stbd side wasted exhaust fix leak 5) engine room stbd outboard of main engine remoe and renew rotten planks to good material *save all removed fasteners 6)tighten bathrom seasuction valve (port side) 7) remove and cap excessive pipe on stbd side fwd head suction
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 September 2023 Resolved
The owner or managing operator shall make a vessel available for drydock examinations and internal structure examinations for certification. Vessel has lapsed the drydock and internal structure exam expiration dates, 31AUG2023, on its COI. Allow inspection for satisfactory drydock and internal structure exam credit prior to the carraige of passengers. 46CFR176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2023
Resolution: Vessel completed satisfactory hull inspection and internal structure exam for credit dry dock.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 March 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Marine Inspector identified a proud plank in the #2 forward compartment on the starboard side, estimated 7 planks above the keel and below the waterline. Plank is found inset 3/8" and inspector is unable to verify if the original plank construction provides this inset or if the butt end of the plank is pulling the fastener out of the transverse frame. The two sandwiched white oak pieces that make up the transverse frame were found separated at the location of the proud plank butt end. The vessel is restricted to a Lakes, Bays, and Sounds route until proper repairs are completed to the satisfaction of the attending marine inspector. 46 CFR 176.700
Action required: 705 - Other - as specified
Due 16 March 2022
Resolved 14 October 2022
Resolution: Plank renewed. See documents for repair proposal and photos.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 March 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Identified an improper repair to the port rudder post support. The wood around the rudder post support securing bolt was found decayed and the owner repaired a 5" diameter 4" deep area of wood with epoxy around the securing bolt. Crop and renew the wood as original. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 16 April 2022
Resolution: Wood cropped and renewed via scarf with in kin-peice using expoxy to seal.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 August 2021 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the three months before or after each anniversary date. Vessel is greater than three months past the anniversary date. Complete all required inspections prior to carriage of passengers. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2021
Resolved 16 March 2022
Resolution: Completed COI and credit DD/ISE.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 August 2020 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. The 25 person life float's 2 inch woven straps around the body of the life float were sun damaged and broke under tension. Repair or replace as original with approved material from the life float manufacturer in accordance with 46CFR160.027. Vessel restricted to 3 NM from shore. 46 CFR 185.700
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 14 August 2020
Resolution: Life float 2 inch woven straps replaced and confirmed to meet standards found in 46 CFR 160.027.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 August 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. All perishable items in the on-board first aid kit were past their expiration date. Replace as original. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 14 August 2020
Resolution: First Aid Kit replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 5 August 2020 Resolved
Internal combustion engine exhausts must be kept clear of and suitably insulated from combustible material. The Port Engine's exhaust lagging was fallen off. Insulate exhaust pipe prior to cooling water entering piping. 46 CFR 177.405(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 14 August 2020
Resolution: Insulation placed on exhaust piping prior to water cooled section.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 August 2020 Resolved
Whenever damage or deterioration to the hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may... require the vessel to... effect permanent repairs. During the internal inspection of the vessel the following areas were found to have structural damage due to different forms of rot. Prior to conducting repairs, submit a repair proposal following NVIC 7-95 in accordance with 46 CFR 176.700 for approval from the OCMI. -Transverse under-deck frame in lazarette, port side rotted with fasteners completely exposed. -Deck plywood in mid-hull hold (forward of lazarette), below storage locker, port side, found with crack in the deck and water leaking into hold. -Transverse rib stiffeners, port side engine room, outboard of port main engine, found with severe rot in multiple adjacent frames. 46 CFR 176.600(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 14 August 2020
Resolution: Repair details under document section of activity. Transverse under-deck frame in lazarette, port side replaced and scarfed in to place, Deck plywood replaced in kind, sister rib stiffeners in the port side engine room outboard of main engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 May 2019 Resolved
Operator installed a gasoline powered generator and a/c unit on the upper deck without appoval of the cognizant [name withheld] unapproved gasoline generator installation prior to operation with passengers. 46 CFR 176.700(a)(b)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2019
Resolution: Operator removed generator from vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 April 2019 Resolved
A hatch exposed to the weather must be watertight. make repairs to three watertight hatches as identified on the main deck and prove proper operation prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2019
Resolution: Operator repaired hatches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019 Resolved
Piping used in a vital system must: Be composed of ferrous aterials except when: Nonmetallic piping materials are permitted by §182.720; or Nonferrous metallic piping materials are permitted by §182.730. Replace unapproved flex hose installed in engine water cooling exhaust line and in bilge piping as identified, with approved flex hose to the satisfaction of the attending Marine Inspector. 46 CFR 182.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 30 April 2019
Resolution: Operator replaced flex hose with approved type.
Engineering › Bilge Water Management System › Valve
Issued 22 May 2018 Resolved
Install positive shut-off valves servicing electrical submersible pumps in steering gear, fuel tank, and wheel house compartments. 46 CFR 182.530(e)(7)
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Operator installed ball valves as required.
Lifesaving › Lifebuoys › Approval
Issued 22 May 2018 Resolved
11117 - Replace life ring buoy with one approved IAW 160.050 and not less than 24 inches in diameter. 46 CFR 180.70(a)(3)
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Operator installed new approved 24 inch life ring buoy.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 July 2016 Resolved
Repair or replace holed exhaust piping on port and starboard main engines.
Due 1 August 2016
Resolved 18 July 2016
Resolution: Operator installed a coupling around the pipe and secured with hose clamps. Operator plans to replace exhaust piping at next dry dock.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 July 2016 Resolved
Prove radio can display position in latitude and longitude for DSC.
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 13 August 2016
Resolution: Operator connected GPS to the VHF radio. Verified GPS input.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.