This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 22 January 2009
…with no type recorded30
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1981–2009)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-46337

Documentation record

Registered dimensions (L × B × D)120.0 ft × 26.9 ft × 7.5 ft
Registered tonnagegross 193 / net 193
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWEAVER SHIPYARDS · ORANGE, TX, UNITED STATES · built 1969
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFREEPORT, TX
Endorsements, as the file codes themcw_un
DocumentationValid · issued 1 April 2026 · expires 31 March 2027
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it193 - Regulatory (Subpart C or D), Gross Ton
193 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 69 inspections, each with its date, unit and type; 52 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 69

22 January 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3398384
8 September 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3318343
18 June 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3240668
1 October 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3068100
30 August 2007 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3042356
13 September 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2777538
29 August 2006 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2762291
1 July 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2771768
23 February 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2590849
6 September 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2485344
19 August 2005 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2467828
2 August 2005 MTSA Verification · Examination of Repairs · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2359377
20 October 2004 MTSA Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2224949
25 May 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2077470
10 May 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2063880
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968434
30 April 2003 Periodic Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1783021
2 May 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1614549
17 April 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1399599
20 April 2000 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1384421
8 April 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421640
7 July 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 418190
9 April 1998 Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452398
25 March 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 509702
28 December 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 665839
23 October 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 12946
23 October 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 196812
23 October 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 212014
27 May 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 785694
17 April 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460955
15 May 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1082542
17 April 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460861
25 March 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 196815
25 March 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 759593
19 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 665836
12 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 473654
20 December 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 196809
3 October 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 665834
29 September 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 441033
14 August 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437023
16 June 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1382980
20 April 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1468353
20 May 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1146944
21 April 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1179099
24 August 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 665828
23 August 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 438170
14 April 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1146740
23 February 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 98117
23 February 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 149690
23 February 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 216256
23 February 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 509719
26 January 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 447138
21 September 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 665820
27 August 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 471047
16 June 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 351488
4 June 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 466397
1 May 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962901
23 April 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 949783
25 October 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 937969
18 October 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1251136
20 June 1990 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1239836
28 August 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1344168
11 May 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1038752
4 May 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331832
30 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023467
11 March 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020282
12 August 1985 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985829
29 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964931
12 January 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963928

Deficiency record · 52

Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 September 2008 Resolved
Ladder at port side portable lube oil tank is loose and not secured properly as required by 46 CFR 32.02-15.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 October 2008
Resolved 21 January 2009
Resolution: Secured ladder at port side portable lube oil tank with a bracket.
Pollution Prevention/Response › Prevention Equipment › Emergency Control Systems (tank barges)
Issued 8 September 2008 Resolved
Emergency stop cable conduit needs repair as required by 33 CFR 155.780(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 October 2008
Resolved 21 January 2009
Resolution: Repaired Emergency stop cable conduit as required by 33 CFR 155.780(c).
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 8 September 2008 Resolved
Permanently seal cap in way of air separator or provide containment underneath as required by 33 CFR 155.310(a)
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 October 2008
Resolved 21 January 2009
Resolution: Permanently sealed cap in way of air separator as required by 33 CFR 155.310(a).
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 8 September 2008 Resolved
Repair leak on the cargo transfer pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 October 2008
Resolved 21 January 2009
Resolution: Replaced piping elbow to the cargo transfer pump.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 8 September 2008 Resolved
Complete cargo transfer procedures need to be provided as required by 33 CFR 155.750. Existing procedures are incomplete.
Action required: 705 - Other - as specified
Due 8 October 2008
Resolved 21 January 2009
Resolution: Included a more detailed one line diagram and completed cargo transfer procedures as required by 33 CFR 155.750.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 30 August 2007 Resolved
Update Fuel Oil Transfer Procedure IAW 33CFR 155.750 for review and USCG examined letter.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 4 October 2007
Resolution: Updated fuel oil transfer procedures.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 30 August 2007 Resolved
Repair/Renew pump prime mover wiring including chafing.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 1 October 2007
Resolution: Renewed wiring on the pump prime mover and provided chafing gear.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 August 2007 Resolved
Prove port and starboard lighting stanchions meet COLREGS.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 1 October 2007
Resolution: Proved port and starboard lighting stanchions meet the COLREGS.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 30 August 2007 Resolved
Submit request to renew letter of alternative compliance for dual barge-single tankerman transfers.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 28 November 2007
Resolution: Requirement withdrawn this date. Vessel operator indicated that there is not intent to continue to conduct dual barge, single tankerman transfers.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 29 August 2006 Resolved
Repair all oil leaks on transfer pump prime mover.
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 11 September 2006
Resolution: Repaired all oil leaks on transfer pump prime mover.
Engineering › Freshwater System (air cooling) › Storage Tank
Issued 29 August 2006 Resolved
Remove the excessive oil build-up from the radiator cooling fins on the prime mover.
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 11 September 2006
Resolution: Replaced radiator
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 August 2006 Resolved
Remove dead-ended wire at the transfer pump and provide a cover for the electrical junction box as required by 46 CFR 111.81
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 11 September 2006
Resolution: Removed dead-ended wire at the transfer pump and provided a cover for the electrical junction box.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 29 August 2006 Resolved
Provide four (4) cargo hatch cover flame screens that meet the requirements of 46 CFR 56.50-85
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 11 September 2006
Resolution: Provided cargo hatch flame screens.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 August 2006 Resolved
Remove or prove operation of the navigation lights as required by the COLREGS.
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 11 September 2006
Resolution: Removed navigation lights.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 29 August 2006 Resolved
Provide insulation for the prime mover muffler as required by 46 CFR 56.50-1
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 11 September 2006
Resolution: Provided insulation for the prime mover muffler.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 29 August 2006 Resolved
Replace the two (2) (pink) 2in transfer hoses that have the outer jacket worn through as required by 46 CFR 156.170.
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 11 September 2006
Resolution: Replaced worn transfer hoses.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 29 August 2006 Resolved
Provide proof that all transfer hoses on board vessel have been hydrostatically tested as required by 46 CFR 156.170
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 11 September 2006
Resolution: Provided proof that all transfer hoses on board vessel have been hydrostatically tested.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 2 August 2005 Resolved
Provide on board vessel non-sparking shovel and emulsifiers for discharge removal kit as required by 33 CFR 155.210
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2005
Resolved 2 August 2005
Resolution: Cleaned resevoir.
Electrical › Electric Supply System (service) › Cable
Issued 2 August 2005 Resolved
Replace chafed battery cable on start system of prime mover as required by 46 CFR 111.15-20
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2005
Resolved 2 August 2005
Resolution: Battery cable replaced with new cables.
Electrical › Electric Supply System (service) › Cable
Issued 2 August 2005 Resolved
Remove water pump wiring as required by 46 CFR 111.60-11
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2005
Resolved 2 August 2005
Resolution: Removed water pump wiring.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 2 August 2005 Resolved
Renew and prove operation of emergency shutdown cable for prime mover as required by 46 CFR 32.50-35
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2005
Resolved 2 August 2005
Resolution: Replaced emergency shutdown cable with new.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 2 August 2005 Resolved
Clean prime mover containment reservior as required by 33 CFR 155.310.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2005
Resolved 2 August 2005
Resolution: Containment was clean out.
Deck/Cargo › Mooring/Anchoring
Issued 11 May 2004 Resolved
Make proper repair to crack in weld IWO port stern timberhead, no later than 10 June 2004 LEGACY COMPONENT DESC: Timber Head
Condition: Unknown
Due 10 June 2004
Resolved 25 May 2004
Engineering › Fuel Oil Service System
Issued 30 April 2003 Resolved
Replace worn flexible non-metallic fuel hose on auxiliary cargo pump engine, meeting SAE J-1942 standard, as per 46 CFR 56.50-75(b)(3). LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 30 April 2003
Resolution: Replaced worn flexible non-metallic fuel hose on auxiliary cargo pump engine with new hose meeting SAE J-1942 standard.
Engineering › Fuel Oil Service System › Valve
Issued 30 April 2003 Resolved
Install fuel oil shut-off valve as close as possible to fuel pump on cargo pump engine as per 46 CFR 56.50-75(b)(4).
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 30 April 2003
Resolution: Installed fuel oil shut-off valve as close as possible to fuel pump on cargo pump engine.
Engineering › Fuel Oil Service System
Issued 30 April 2003 Resolved
Install fuel oil shut-off valve as close as possible to fuel pump on auxiliary cargo pump engine as per 46 CFR 56.50-75(b)(4). LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 30 April 2003
Resolution: Installed fuel oil shut-off valve as close as possible to fuel pump on auxiliary cargo pump engine.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 2 May 2002 Resolved
Demonstrate proper operation emergency shutdown for cargo pump main engine. Vessel may not use cargo pump main engine prior to demonstrating proper operation. 46 CFR 32.50-55
Action required: 703 - Prior to bunkering operations
Due 2 May 2002
Resolved 2 May 2002
Resolution: Witnessed operational test of emergency shutdown. Test satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 2 May 2002 Resolved
Test cargo pump discharge gauge per 46 CFR 35.35-70.
Due 2 June 2002
Resolved 2 May 2002
Resolution: New gauge was installed.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 2 May 2002 Resolved
Submit proposal to MSO Mobile for dealing with containment requirements for fill pipe on deck tanks per 33 CFR 155.320(b). Complete repairs after submitting proposal. The fill pipe for the deck tanks do not allow for placement of portable containment.
Due 6 May 2002
Resolved 6 May 2002
Resolution: Company fabricated pipe that can be attached to the opening of the deck tanks. The pipe is taller than the vent on the tank. Thus, should the tank overfill, the product will overfill through the vent and into the portable containment under the vent.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 2 May 2002 Resolved
Amend transfer procedures to reflect use of portable contaiment on deck tanks during transfer operations. Also, add topping off procedures including method of gauging.
Due 2 June 2002
Resolved 6 May 2002
Resolution: Transfer procedures amended for use of gauging pipe, placement of portable containment under vent, and gauging tanks with sounding stick while topping off.
Deck/Cargo
Issued 17 April 1997 Resolved
STRIPPING PUMP WAS INOPERABLE, REPAIR AND PROVE PROPER OPERATION.INSTALL PRESSURE GAUGE AT DISCHARGE IAW 46 CFR 32.50-5(b).
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Lifesaving
Issued 17 April 1997 Resolved
INSTALL PACKING AROUND ALL VALVE OPERATING RODS PENETRATING THE DECK AT CARGO TANKS, IAW 46 CFR 32.50-15(b).
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Engineering
Issued 17 April 1997 Resolved
REPAIR AND PROVE OPERATION OF TACHOMETER ON CARGO PUMP INTERNAL COMBUSTION ENGINE IAW 46 CFR 31.01-1(a).
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Engineering
Issued 17 April 1997 Resolved
RENEW 5'6" SECTION OF FLEXIBLE HOSE RUNNING FROM #2 PORT CARGO TANK TO CARGO PUMP WITH HARD PIPING/FLEXIBLE HOSE LESS THAN 30" LONG IAW 33 CFR 56.60(C)(4).
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Deck/Cargo
Issued 17 April 1996 Resolved
PROVIDE PROTECTIVE COVER FOR DIESEL ENGINE CARGO PUMP. _x001C_ SPECIFIC CITE: 46 CFR 32.35-5
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Construction/Loadline
Issued 17 April 1996 Resolved
RE-STENCIL AFT STARBOARD DRAFT MARKS. _x001C_ SPECIFIC CITE: 46 CFR 32.05-1
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Deck/Cargo
Issued 17 April 1996 Resolved
RENEW FLAME SCREEN FOR #2 PORT VENT. _x001C_ SPECIFIC CITE: 46 CFR 32.55-25
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Engineering
Issued 21 April 1994 Resolved
INSTALL GUARD OR INSULATE CARGO PUMP ENGINE EXHAUST PIPING TO INSURE AGAINST ACCIDENTAL TOUCH OF HOT EXHAUST PIPING IAW 46 CFR 32.02-15.
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Navigation
Issued 21 April 1994 Resolved
PROPERLY ALIGN ALL NAVIGATION LIGHT SCREENS.
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Electrical
Issued 21 April 1994 Resolved
RENEW POTABLE WATER PUMP ELECTRICAL INSTALLATION TO MEET THE REQUIREMENTS SETFORTH IN 46 CFR 111.105.
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Lifesaving
Issued 21 April 1994 Resolved
THE NAME AND HAILING PORT OF VESSEL MUST BE MARKED IN CLEARLY LEGIBLE LETTERS NOT LESS THAN FOUR (4) INCHES IN HEIGHT ON SOME CLEARLY VISIBLE EXTERIOR PART OF THE STERN IAW 46CFR67.15-3
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Lifesaving
Issued 21 April 1994 Resolved
THE NAME OF VESSEL MUST BE MARKED IN CLEARLY LEGIBLE LETTERS NOT LESS THAN (4) INCHES IN HEIGHT ON SOME CLEARLY VISIBLE EXTERIOR PART OF THE PORT AND STARBOARD BOW IAW 46CFR67.15-3.
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Deck/Cargo
Issued 21 April 1994 Resolved
RENEW FLAME SCREEN TO AFT SLOP TANK VENT WITH 30 X 30 MESH SCREEN
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Deck/Cargo
Issued 21 April 1994 Resolved
RENEW FRESH WATER TANK VENTS WITH 20X20 MESH SCREEN
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Engineering
Issued 21 April 1994 Resolved
LABEL DIESEL OIL DAY TANK WITH CONTENTS CONTAIN WITHIN TANK ON OUTSIDE OF TANK.
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Deck/Cargo
Issued 21 April 1994 Resolved
MARK ALL CARGO DOMES WITH "DANGER KEEP OUT".
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Engineering
Issued 21 April 1994 Resolved
RENEW NON-METALIIC FLEXIBLE HOSES ON FUEL OIL SYSTEM TO MEET REQUIREMENTS OF 46CFR56.60-25. ALL HOSES SHALL MEET SAE STANDARD J-1942 AND INSTALLED INLENGTHS NOT TO EXCEED 30 INCHES.
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Deck/Cargo
Issued 16 June 1992 Resolved
SPECIFIC CITE: 33 C.F.R. 155.310(b)(2)_x001C_ NO PORTABLE CONTAINMENT UNDER HOSE CONNECTION ON DECK.
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Unknown
Issued 16 June 1992 Resolved
TRANSFER REQUIREMENTS WERE NOT MET ON THE DOI DUE TO LACK OF COMMUNICATION EQUIPMENT.
Condition: Unknown
Due 16 June 1992
Resolved 17 June 1992
Deck/Cargo
Issued 16 June 1992 Resolved
TRANSFER HOSE DID NOT HAVE THE MAWP OR THE SERVICE MARKED ON IT IN ANY WAY.
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Documentation
Issued 16 June 1992 Resolved
TRANSFER PROCEDURES DID NOT HAVE A MEANS OF COMMUNICATIONS FOR THE TANKERMAN LISTED.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Deck/Cargo
Issued 11 March 1987 Resolved
TEST CARGO PIPE, RELIEF VALVE, AND PRESSURE GAUGE IAW 33 CFR 156.170(C) PRIOR TO LOADING CARGO BUT NOT LATER THAN 11 MAR 88. TEST TO BE TO THE SATISFACTION OF THE ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987