MAURY USCG vessel records Sign in
← All vessels

VAGABOND

VAGABOND is a 1969 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1985, most recently in April 2026, along with 56 deficiencies and 3 casualty investigations between 2003 and 2025.

Records from 1985 to 2026. Most recent: inspection, 28 April 2026.

Built
1969
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7520
Flag
UNITED STATES
368347000
Maury page id
psix-46359

Inspections, by type

…with no type recorded10
Years with a record 37 calendar years (1985–2026)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)69.3 ft × 22.6 ft × 9.2 ft
Registered tonnagegross 96 / net 69
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · NATIONAL CITY CA · built 1969
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
69 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD7520MMSI 368347000 · active · compulsorily equipped · granted 10 March 2017, expires 15 May 2027
WY7632MMSI not assigned · expired · compulsorily equipped · granted 2 January 1997, cancelled 3 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 86

28 April 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8332039
22 October 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8257540
21 October 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8258207
10 April 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8109418
26 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8100319
12 July 2024 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8390424
11 July 2024 Deficiency Check · Administrative Inspection · In-Service Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7956690
17 April 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7896837
31 October 2023 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7818050
9 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7684366
16 February 2023 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7637908
28 December 2022 Administrative Inspection · In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7629381
25 April 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7437520
20 October 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7336646
2 September 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7302411
12 May 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7195407
22 February 2021 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7144103
16 April 2020 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6937614
26 March 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6932007
14 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6834082
28 May 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6683018
12 March 2019 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6640579
7 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6534766
16 May 2018 Deficiency Check · Annual Inspection · DAPI Audit · Construction Oversight · Inclining Experiment · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6416433
17 May 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6148353
7 March 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6100416
3 May 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5868027
23 September 2011 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4152753
24 February 2011 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3951996
24 February 2011 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3952001
4 January 2011 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3921759
27 April 2009 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3444549
21 January 2009 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3397789
23 May 2008 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3214378
8 April 2008 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3157712
29 May 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2858814
15 March 2007 Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2858810
2 May 2006 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2589903
3 May 2005 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2315908
11 March 2005 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2279937
22 June 2004 MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2106896
25 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2077897
29 April 2004 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2034159
8 March 2004 Deficiency Check · Plan Review "T" Boat · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2020816
24 July 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1859558
16 June 2003 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1818790
11 June 2003 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1815223
16 May 2003 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1792138
26 March 2003 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1812298
14 March 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1756252
26 August 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1667143
19 August 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1663257
12 April 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1602241
14 March 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1492899
25 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1067383
5 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1065395
30 April 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1444513
21 March 2001 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1426578
15 March 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1413892
31 March 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1365723
17 March 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1386736
15 April 1999 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375836
28 March 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1116502
21 April 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1388562
23 March 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1419939
11 April 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1374955
5 March 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1383467
14 February 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1105755
28 March 1996 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1441100
27 March 1995 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1400164
22 March 1994 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1410932
30 March 1993 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1435357
17 March 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1268664
13 March 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 954296
5 March 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1315848
14 March 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1223448
8 March 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1217454
14 March 1990 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 904005
13 March 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1201270
9 March 1989 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1201491
9 March 1988 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1028808
16 March 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1016474
3 March 1987 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1314682
20 March 1986 COI Inspection · Credit Drydock
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 995231
28 March 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 980419
7 March 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 982529

Deficiency record · 56

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 October 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of hull. Port main engine is inoperable. Upon return to San Diego Harbor Submit casual analysis, technician report attesting to report, and conduct sea trial prior to carrying passengers.46CFR182.200(a) 701C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2025
Resolution: Vessel completed required repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 April 2025 Resolved
Vessel required to have one 24" ring lifebuoy fitted with 60' lifeline and floating water light attached with a corrosion resistant clip to allow quick disconnect. Ring lifebouy found cracked and faded. Provide serviceable ring lifebuoy onboard vessel and properly arranged. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 18 April 2025
Resolution: Attended vessel and saw new lifebouy. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 April 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found plug socket in the wheel house under the operating station was missing its cover. Replace cover on outlet box. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 18 April 2025
Resolution: Attended vessel and saw electrical cover installed. All SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 10 April 2025 Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. MI found accumulation of grease in the galley. Clean gally and submit photos to local OCMI. 46 CFR 176.818
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 18 April 2025
Resolution: Attended vessel and saw gallay was cleaned. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 November 2023 Resolved
REPAIRS TO THE HULL MUST NOT BE MADE WITHOUT THE APPROVAL OF THE COGNIZANT OCMI. A repair plan shall be provided with an additional inspection of the hull, after the removal water saturated foam and fiberglass. Upon approval of repair plan, completed repair as per plan, and to make repairs available for inspections prior to painting. 46CFR 176.700
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2023
Resolution: Inspected final repair; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 October 2023 Resolved
REPAIRS TO THE HULL MUST NOT BE MADE WITHOUT THE APPROVAL OF THE COGNIZANT [name withheld] for repairs of damaged bow.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2023
Resolution: Further inspections will follow.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 May 2023 Resolved
Install emergency lighting in aft berthing area stairwell. Cite: 46 CFR 184.30-5(Old-T).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 11 September 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 May 2021 Resolved
Emergency lighting in the aft-most berthing area was not operational. Repair/replace the emergency lighting in aft-berthing. Overnight passenger count reduced to 26 until this deficiency is corrected.
Action required: 705 - Other - as specified
Resolved 28 May 2021
Resolution: e lighing operational
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 May 2021 Resolved
There is no PA system or general alarm in the forward-most and aft-most staterooms. Install a PA system or general alarm in these berthing areas so that a person in the wheelhouse can notify these berthing areas of emergencies.
Action required: 705 - Other - as specified
Resolved 28 May 2021
Resolution: PA operational
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps. Due 14Jan2020.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 January 2020
Resolved 26 March 2020
Resolution: Received.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 October 2019 Resolved
Install exit signs with directional arrows toward emergency escapes in passenger/crew berthing spaces. Install escape lighting at emergency escape hatches. Due 14Nov2019.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 27 December 2019
Resolution: Installed lighting and signs.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 October 2019 Resolved
Install smoke detectors in all passenger state rooms. Due 14Nov2019.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 27 December 2019
Resolution: Installed smoke detectors in state rooms.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2019 Resolved
Ensure that all cables feeding junction boxes/switches is properly secured such that the individual wires are not exposed outside of the junction boxes/switches. Due 14Nov2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 27 December 2019
Resolution: Wires properly joind in J-box.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 September 2018 Resolved
CLSN: Vsl is not broadcasting a Call Sign, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 April 2019
Resolution: Verifeid in VIVS.
Construction/Loadline › Hull › Side Shell
Issued 16 May 2018 Resolved
Starboard side has three through hulls above the water line that need to be capped.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2018
Resolved 26 June 2018
Resolution: Through hulls capped.
Fire Fighting › Fire Main › Valves
Issued 8 April 2008 Resolved
Prove proper operation of port fire system and hose.
Due 22 April 2008
Resolved 15 April 2008
Engineering › Fuel Oil Service System › Valve, Settler Tank
Issued 8 April 2008 Resolved
Mark fuel shutoff for day tank in letters at least 1" high IAW 46CFR185.608.
Due 8 May 2008
Resolved 15 April 2008
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 29 May 2007 Resolved
Replace damaged ground wire from port MDE starter motor.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 29 May 2007
Fire Fighting › Fire Main › Pressure
Issued 29 May 2007 Resolved
Repair/replace fire pump pressure gauge.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 31 May 2007
Engineering › Fuel Oil Service System › Hose
Issued 29 May 2007 Resolved
Double hose clamp fuel lines at fuel manifold.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 29 May 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 May 2007 Resolved
Label all emergency lights in accommodation spaces.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 31 May 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 May 2007 Resolved
Replace (8) adult Type-1 PFDs. Vessel restricted to no more than 32 total persons until corrected.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 31 May 2007
Construction/Loadline › Hull › Keel
Issued 15 March 2007 Resolved
Repair cracks in FRP bulbous bow.
Due 15 March 2007
Resolved 23 March 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 15 March 2007 Resolved
Permanantly mark draft marks per 46 CFR 185.62.
Due 15 March 2007
Resolved 23 April 2007
Construction/Loadline › Hull › Bottom Plating
Issued 15 March 2007 Resolved
Provide repair proposal for port laz pitting/corrosion. Crop and renew or guage.
Due 15 March 2007
Resolved 23 March 2007
Engineering › Electric Propulsion System › Cable
Issued 3 May 2005 Resolved
Starboard engine inoperable--it would not start. Repair to satisfaction of attending marine surveyor & provide repair report.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2005
Resolved 6 May 2005
Resolution: Selenoid replaced. Marine inspector witnessed operation at dock & during underway checkride. All was satisfactory.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 3 May 2005 Resolved
Prove proper installation of both liferafts, including hydrostatic release units. Due to inop engine, vessel unable to move to dock for loading liferafts after they were serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2005
Resolved 6 May 2005
Resolution: Marine inspector witnessed proper installation of liferafts, including hydro-release units.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 May 2005 Resolved
Replace masthead light lens cover. Found masthead light lens (cover) broken.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2005
Resolved 6 May 2005
Resolution: Masthead light lens cover replaced.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2005 Resolved
Provide evidence of updated (currently correct) charts. Found paper charts outdated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 6 May 2005
Resolution: New, currently corrected updated charts found on board.
Navigation › Piloting/Steering › US Coast Pilot
Issued 3 May 2005 Resolved
Provide evidence of updated US Coast Pilot, or excerpts, for areas vessel transits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 6 May 2005
Resolution: MI witnessed currently corrected US Coast Pilot on board.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 May 2005 Resolved
Provide updated CG Light List. Outdated list found on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 6 May 2005
Resolution: MI witnessed currently correct Light List on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2005 Resolved
Replace expired items (asprin, inhalants, & ointments) in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 6 May 2005
Resolution: New items found on board.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 May 2005 Resolved
Install metallic removable clip on lifering light. Line is currently spliced around lifering, w/o a clip.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 6 May 2005
Engineering › Steering Gear System › Linkage
Issued 3 May 2005 Resolved
Prove proper installation of steering. Steering cables not connected.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2005
Resolved 6 May 2005
Resolution: New shift cables installed on starboard engine.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 May 2005 Resolved
Conduct underway man over-board drill. Unable to conduct drill due to inop engine.
Action required: 705 - Other - as specified
Due 10 May 2005
Resolved 6 May 2005
Resolution: Satisfactory u/w man overboard drill conducted. Excellent de-brief conducted.
Electrical › Lighting (service)
Issued 16 May 2003 Resolved
A lens cover is required on the 4' florescent light fixture above the chart table on the bridge. IAW 46 CFR 183.410(a). LEGACY COMPONENT DESC: Lighting Fixture
Due 16 June 2003
Resolved 16 June 2003
Lifesaving › Embarkation Appliances/Stations
Issued 16 May 2003 Resolved
Provide adaquate Rescue Ladder/Platform to the satisfaction of the U.S. Coast Guard Inspector.
Due 16 June 2003
Resolved 16 June 2003
Documentation › Logs/Records
Issued 16 May 2003 Resolved
Vessel is required to have and maintain an EPIRB test log. IAW 46 CFR 185.728 (c). LEGACY COMPONENT DESC: EPIRB Test Log
Due 16 June 2003
Resolved 16 June 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 16 May 2003 Resolved
Provide Fire Extinguisher servicing report. IAW 46 176.810 LEGACY COMPONENT DESC: Service
Due 16 June 2003
Resolved 16 June 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 16 May 2003 Resolved
A B-II Fire Extinguisher is out of service date. Must be serviced annually. IAW 46 CFR 181.500(a). LEGACY COMPONENT DESC: Service
Due 16 June 2003
Resolved 16 June 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 16 May 2003 Resolved
Galley ventilation hood needs to have the screen cleaned free of grease. IAW 46 CFR 176.818 LEGACY COMPONENT DESC: Galley Ventilation Hood
Due 16 June 2003
Resolved 16 June 2003
Documentation › Manuals/Policy Documentation
Issued 16 May 2003 Resolved
Conduct audit and update of ISM Manual. LEGACY COMPONENT DESC: Audit of ISM Manual
Due 16 June 2003
Resolved 16 June 2003
Lifesaving › Buoyant Smoke Signals
Issued 16 May 2003 Resolved
Add (1) one additional orange day smoke flare to maintain a required inventory of (6) six. IAW 46 CFR 180.68 (b)(1)(2). LEGACY COMPONENT DESC: Orange Day Smoke
Due 16 May 2003
Resolved 16 May 2003
Personnel › Training › Familiarization Training
Issued 12 April 2002 Resolved
Demonstrate satisfactory fire & man overboard drill
Action required: 705 - Other - as specified
Due 13 May 2002
Resolved 2 May 2002
Electrical
Issued 12 April 2002 Resolved
Remove or dead end wires in electrical closet, fwd bunk room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2002
Resolved 2 May 2002
Construction/Loadline
Issued 15 March 2001 Resolved
provide metallic valves and penetrations for PVC piping.
Condition: Unknown
Due 15 March 2001
Resolved 15 March 2001
Lifesaving
Issued 15 March 2001 Resolved
Provide damage control kitto be stored in an accessible area above the bulkhead deck.
Condition: Unknown
Due 15 March 2001
Resolved 15 March 2001
Engineering
Issued 28 March 1996 Resolved
Properly repair or renew leaking exhaust system located in passenger berthing aft of engine compartment on starboard side.
Condition: Unknown
Due 28 March 1996
Resolved 5 August 1996
Lifesaving
Issued 28 March 1996 Resolved
Properly renew or repair two adult PFDs.
Condition: Unknown
Due 28 March 1996
Resolved 5 August 1996
Lifesaving
Issued 27 March 1995 Resolved
PROPERLY SERVICE AND INSTALL TWO LIFERAFTS.
Condition: Unknown
Due 31 March 1995
Resolved 19 April 1995
Lifesaving
Issued 27 March 1995 Resolved
REPAIR OR REPLACE 9 PFD'S FOR TOTAL OF 43 ABOARD.
Condition: Unknown
Due 31 March 1995
Resolved 19 April 1995
Electrical
Issued 13 March 1992 Resolved
PROVIDE LOCK-OUT DEVICE FOR SHIP SERVICE GENERATOR CONTROL BOARD TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Lifesaving
Issued 9 March 1989 Resolved
PROVIDE TWO INFLATABLE LIFERAFTS ONBOARD.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Documentation
Issued 9 March 1989 Resolved
COMPLETE FCC INSPECTION.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Documentation
Issued 9 March 1988 Resolved
PROVIDE COMMUNICATIONS ACT SAFTEY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 9 March 1988
Resolved 9 March 1988
Lifesaving
Issued 9 March 1988 Resolved
SERVICE INFLATABLE LIFERAFTS.
Condition: Unknown
Due 9 March 1988
Resolved 9 March 1988

Casualty record · 3

24 July 2003Routine · role: Involved in a Marine Casualty · 1 dead · activity 1859558
12 July 2024Routine · role: Involved in a Marine Investigation (non-casualty) · activity 8390424
21 October 2025Routine · role: Involved in a Marine Casualty · activity 8258207
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record