Records from 1998 to 2026. Most recent: inspection, 3 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 49
3 June 2026
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8352531
10 April 2026
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8345824
2 September 2025
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8219635
3 September 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7985973
3 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7889421
6 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7773096
6 September 2022
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7555279
29 April 2022
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7417309
1 June 2021
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7164827
3 September 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7042665
7 May 2020
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6949597
9 April 2020
Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6940354
23 January 2020
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6894504
30 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6880678
17 December 2019
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6875113
11 September 2019
DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6809973
5 September 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6792757
24 August 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6521388
20 March 2018
In-Service Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6374974
5 September 2017
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6256813
7 June 2016
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5894780
1 June 2016
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5893004
3 May 2016
Drydock Extension
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5874981
2 September 2015
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5227871
6 August 2015
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5207679
8 May 2012
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4307069
11 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4223062
16 September 2011
DAPI Audit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4147024
1 September 2010
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3840479
12 September 2008
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3323408
8 September 2008
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3318349
28 April 2008
Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3197043
7 September 2007
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3051006
7 June 2006
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2667458
9 May 2006
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2643518
1 August 2005
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2474170
2 September 2004
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2189377
11 May 2004
Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2064507
3 September 2003
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1896385
4 September 2002
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1671228
17 May 2002
Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1617929
7 September 2001
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1073461
7 June 2001
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1382274
8 September 2000
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1389204
12 May 2000
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1049590
2 May 2000
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1051048
22 June 1999
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1378738
10 June 1998
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1444082
18 May 1998
Construction Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 809095
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 3 September 2024
Resolved
Provide valid FCC Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2024
Resolved 30 September 2024
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 6 September 2022
Resolved
Found FCC safety and bridge to bridge certificates expired.
Action required: 705 - Other - as specified
Due 9 October 2022
Resolved 7 October 2022
Resolution: FCC Safety certificate issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 September 2022
Resolved
FWD Life ring not servicable / replace.
Action required: 705 - Other - as specified
Due 9 October 2022
Resolved 7 October 2022
Resolution: New life ring installed on vessel.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 1 June 2021
Resolved
FCC Safety Radio Certificate expired, renew certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 9 September 2022
Resolution: REISSUED DEF.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 September 2019
Resolved
Provide a magnetic compass at the operating station. Vsl had a digital compass only.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2019
Resolved 18 September 2019
Resolution: New compass installed
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 September 2019
Resolved
Provide a USCG Light list and charts for the operational area as described on the COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 18 September 2019
Resolution: Done
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 September 2019
Resolved
Apply the NOAA registration sticker to the EPRIB and put vessel's name on the EPRIB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 18 September 2019
Resolution: Done
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 5 September 2019
Resolved
Provide a Station Bill onboard and post it in a visible area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 18 September 2019
Resolution: Done
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2019
Resolved
Provide spanner wrenches at each fire hydrant.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 18 September 2019
Resolution: Wrench provided
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 September 2019
Resolved
Correctly label the electrical circuits on the distribution panels in the aft cabin.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 27 September 2019
Resolution: Done
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 5 September 2019
Resolved
Repair or replace 2 oars for the stbd life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 18 September 2019
Resolution: New oars provided
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 September 2019
Resolved
Repair the exterior surfaces of all life floats were the outer sheathing is cracked & worn prior to 01 May 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 3 September 2020
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2019
Resolved
Repair or replace the Mizzen boom spar prior to 01 May 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 7 May 2020
Resolution: Received photos and statement of repairs completed by O/O [name withheld] .
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2019
Resolved
Address the jaws on the main gaff prior to 01 MAY 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 7 May 2020
Resolution: Received photos and statement of repairs completed by O/O [name withheld] .
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2019
Resolved
Address the peak eye of the inner job prior to 01 MAy 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 16 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2019
Resolved
Secure the electrical cables every 24" to the overhead in the forward hold.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 27 September 2019
Resolution: Corrected
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 September 2019
Resolved
Weatherproff the electrical conncections for the bilge pump, forward of the main engine.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 27 September 2019
Resolution: Complteted
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 5 September 2019
Resolved
Provide a means of determining when the sewage holding tanks are at 3/4 full.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 27 September 2019
Resolution: Done
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 5 September 2019
Resolved
Repair or replace the gauges for the main engine at the operating station, the oil pressure and water temperature gauges were unreadable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 17 October 2019
Resolution: Corrected
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 September 2018
Resolved
High water alarms for steering compartment failed to indicate an audible tone when tested. Prove proper operation of alarm audible tone.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 12 September 2018
Resolution: Replaced loose connection in wiring.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 September 2018
Resolved
Life floats are required to be arranged to float free. Painter lines were found tangled in line painter cage due to cages being damaged from original configuration. Prove sea painter lines stored in a float free arrangement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 12 September 2018
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 September 2018
Resolved
EPIRB is required to be tested and logged monthly to prove operation. Conduct and log monthly test to prove operation of EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 September 2018
Resolved 4 September 2018
Resolution: Conducted sat test of EPIRB.
Sail Rigging › Stays/Shrouds › Clevis Pins and Cotter Pins
Issued 20 March 2018
Resolved
Foremast Inner Froe stay bail was found spring outward and placing attachment cotter pins in shear causing pins to fail. Correct fairlead on bail to mast connections to prevent assonated connection hardware from remaining in shear.
Action required: 10 - Deficiency Rectified
Due 30 April 2018
Resolved 2 April 2018
Resolution: Bail was removed and lead to load corrected to remove tension from cotter pins.
Sail Rigging › Running Rigging › Blocks
Issued 20 March 2018
Resolved
Jib turning block eye bolts were found pulling through attachment points on gunnel. Provide backings for jib turning blocks (04).
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 1 May 2018
Sail Rigging › Stays/Shrouds › Terminals/End Fittings
Issued 20 March 2018
Resolved
Port Whiskerstay connection shackle located on hull was found improperly installed (shackle pin was not completely threaded) and frozen. Install shackle/pin per manufacture instructions.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 1 May 2018
Resolution: Shackle pin was removed, serviced, and re installed correcly.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 March 2018
Resolved
Provide metal supports for cable runs in machinery space.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 1 May 2018
Fire Fighting › Fire Main › Condition
Issued 20 March 2018
Resolved
Metal hangers for fire main piping were found wasted. Replace hangers to original scantling.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 1 May 2018
Communications › Radio Communications › EPIRB
Issued 5 September 2017
Resolved
Master was not conducting monthly tests and logging results as required by 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Due 5 September 2017
Resolved 5 September 2017
Resolution: Conducted sat test of EPIRB and logged results in ships log.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 September 2017
Resolved
Master could not produce a FCC Safety Radio Certificate to proved proper installation and operation of VHF Radio. Provided FCC Safety Radio Certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 14 September 2017
Stability › Incline Test › General
Issued 5 September 2017
Resolved
A copy of the approved sail plan required by vessels stability letter dated 19 Oct 2012 was not onboard. Provide a copy of the Coast Guard approved sail plan dated June 10, 1998, onboard the vessel for masters reference.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 18 September 2017
Engineering › Bilge Water Management System › Strainer
Issued 5 September 2017
Resolved
Excessive amounts of debris and material are located in bilge pockets in way of suction strainers. This could cause a failure of the bilge water removal system during an emergency. Remove all debris and excessive material from all bilge pockets around suction strainers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 18 September 2017
Engineering › Bilge Water Management System › Pump
Issued 5 September 2017
Resolved
Flexible, nonmetallic hose used to connect bilge pump to suction manifold (vital system) is not SAE J1942 standard hose. Replace hoes with SAE J1942 and make connections IAW 46 CFR 182.720.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 18 September 2017
Sail Rigging › Mast Step › Base
Issued 5 September 2017
Resolved
No documentation could be produced to show a complete inspection of the three most fwd masts of the vessel to include the step and standing rigging. Un-stepping of a mast and down rigging all standing rigging is a key component to insure structural integrity. Un-step the three most fwd masts and make the associated standing rigging and mast steps available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 1 June 2018
Resolution: ddx
Lifesaving › Lifefloat › Lifeline
Issued 5 September 2017
Resolved
Life float's located on aft deck had worn retroreflective tape and frayed life lines. Replace retroreflective tape and lifelines to original condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 18 September 2017
Lifesaving › Lifebuoys › Serviceable
Issued 5 September 2017
Resolved
Ringbouy located on port side was found unserviceable condition. Replace with new buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 18 September 2017
Fire Fighting › Fire Main › Condition
Issued 7 June 2016
Resolved
Repair / replace fire main suction line, remove soft patch temp repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 5 July 2016
Resolution: pipe with soft patch and 6" section of hull replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 September 2015
Resolved
Time Delay Bottle Hydro Expired
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 1 June 2016
Resolution: Replaced. New time delay bottle installed.
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 2 September 2015
Resolved
Install fire stop material through forward and aft cabin wire pentrations.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 1 June 2016
Resolution: Firestop material has been properly installed.
Construction/Loadline › Structures › Superstructure
Issued 2 September 2015
Resolved
Starboard side fwd, and aft skylight frames rotten, missing sky light cover. Repair / replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 1 June 2016
Resolution: Skylights repaired/replaced with new windows and frames.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 2 September 2015
Resolved
Provide updated epirb registration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 1 June 2016
Resolution: Owner updated EPIRB registration.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.3-Comprehensive Annual Inspections
Issued 2 September 2015
Resolved
Provide VGP on vessel and fill out PARI form.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 9 November 2015
Sail Rigging › Spars › Gaffs/Jaws/Saddles/Fittings
Issued 2 September 2015
Resolved
Address rot on mizzen gaff and spanker gaff. Repair / replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 1 June 2016
Resolution: Operator has repaired/replaced 5 spars to include mizzen gaff and spanker gaff.
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 2 September 2015
Resolved
Replace fore peak tackle bolt (bowed / stressed).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 1 June 2016
Resolution: New hardware installed on forepeak tackle bolt.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 2 September 2015
Resolved
Remove rubbish waste in the fwd bilge / house keeping.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 1 June 2016
Resolution: rubbish removed.
Electrical › Electrical Distribution System (service) › Cable
Issued 2 September 2015
Resolved
Attach wire support, remove deadend wires in fwd compartment.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 1 June 2016
Resolution: wire support installation completed.
Construction/Loadline › Structures › Cofferdam
Issued 8 May 2012
Resolved
Create limber holes in engine room bilge to allow water to drain into rosebox.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 30 September 2012
Resolution: Operator has not corrected. Added special note to check during annual exam.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 16 September 2011
Resolved
Company has not submitted the annual MIS report as required by 46 CFR 16.500.
Action required: 705 - Other - as specified
Due 16 October 2011
Resolved 20 October 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 16 September 2011
Resolved
Company has not completed Employee Assistance Program training as required by 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 16 October 2011
Resolved 16 April 2012
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 16 September 2011
Resolved
Company does not have a written drug and alcohol policy distributed and displayed as require by 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 16 October 2011
Resolved 10 October 2011
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 16 September 2011
Resolved
Company does not complete pre-employment background checks as required by 49 CFR 40.25.
Action required: 705 - Other - as specified
Due 16 October 2011
Resolved 10 October 2011
Lifesaving › Lifebuoys › Serviceable
Issued 8 September 2008
Resolved
Replace forward and aft ring buoys and repair mid-ship ring buoy line.
Action required: 705 - Other - as specified
Due 18 September 2008
Resolved 12 September 2008
Resolution: O/O advised new rings purchased.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 September 2008
Resolved
Prove operation of water light on aft ring buoy.
Action required: 705 - Other - as specified
Due 18 September 2008
Resolved 12 September 2008
Resolution: O/O replaced waterlight battery and it now operates satisfcatory.
Fire Fighting › Firemans Outfit › Axe
Issued 8 September 2008
Resolved
Label fire axe with vessel name.
Action required: 705 - Other - as specified
Due 18 September 2008
Resolved 12 September 2008
Resolution: O/O advised that axe has been labeled.
Fire Fighting › Means of Escape › Doorways
Issued 8 September 2008
Resolved
Prove proper operation of Captains Cabin emergency escape.
Action required: 705 - Other - as specified
Due 18 September 2008
Resolved 12 September 2008
Resolution: O/O advised that escape hatch was lubricated and now operates satisfcatory.
Engineering › Bilge Water Management System › Strainer
Issued 8 September 2008
Resolved
Clean debris out of forward passenger space bilge.
Action required: 705 - Other - as specified
Due 18 September 2008
Resolved 12 September 2008
Resolution: O/O advised that crew had cleaned bilges.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 September 2007
Resolved
Provide servicing report for fixed CO2 system, to include testing the heat detectors, per 46 CFR 176.810.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 October 2007
Resolved 12 October 2007
Resolution: Received letter by fax from Morris Fire Protection of Corrinna, ME, via Downeast Windjammer Cruises documenting a sat test of the heat detectors in May 2007.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 7 September 2007
Resolved
Provide approved plans for the vessel's fixed CO2 system, per 46 CFR 177.202.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 9 September 2008
Resolution: Approval letter for system provided. Also found entry in permanent file indicating system installation was inspected satisfactory during initial certification.
Personnel › Training › First Aid/CPR
Issued 1 August 2005
Resolved
SHOW EVIDENCE OF FIRST AID/CPR TRAINING FOR MINIMUM OF 50% OF CREW.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 31 August 2005
Lifesaving › Buoyant Apparatus
Issued 3 September 2003
Resolved
REPLACE ALL LIFEFLOAT WATERLIGHT LANYARDS (DUE TO DETERIORATION). LEGACY COMPONENT DESC: Waterlights
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 3 September 2003
Resolution: CORRECTED DURING THE INSPECTION.
Electrical › Electric Supply System (service) › Cable
Issued 3 September 2003
Resolved
REPAIR VHF ANTENNAE CABLE (BARE SPOT) IN CAPTAIN'S CABIN (STBD-SIDE).
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 3 September 2003
Resolution: CORRECTED DURING THE INSPECTION.
Electrical › Electric Supply System (service) › Cable
Issued 3 September 2003
Resolved
PROVIDE METAL WIRE SUPPORTS EVERY 24 INCHES FOR SHIP'S HORN CABLE IN CAPTAIN'S CABIN.
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 3 September 2003
Resolution: CORRECTED DURING THE INSPECTION.
Fire Fighting › Miscellaneous Items
Issued 3 September 2003
Resolved
MAKE OPERABLE; SMOKE DETECTOR IN FWD ACCOMODATIONS SPACE (CREW'S BERTHING).
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 3 September 2003
Resolution: CORRECTED DURING THE INSPECTION.
Construction/Loadline
Issued 7 June 2001
Resolved
PROVIDE INDIVIDUAL AUDIBLE AND VISUAL INDICATORS FOR EACH BILGE HIGH LEVEL ALARM (FOR ALL REQUIRED COMPARTMENTS) AT OPERATING STATION, AS REQUIRED BY 46CFR182.530.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Documentation
Issued 8 September 2000
Resolved
Missing training and drills in ships log book.
Condition: Unknown
Due 22 September 2000
Resolved 5 October 2000
Engineering
Issued 8 September 2000
Resolved
Remove petcock form fuel filter and replace with plug.
Condition: Unknown
Due 22 September 2000
Resolved 5 October 2000
Construction/Loadline
Issued 2 May 2000
Resolved
SECURE ALL WATERTIGHT HATCHES TO HATCH FRAME OR COAMING VIA HINGES, CAPTIVECHAINS, OR OTHER DEVICES TO PREVENT HATCH LOSS AS PER 46CFR171.124.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2000
Resolved 2 May 2000
Resolution: Installation completed