MAURY USCG vessel records
← All vessels

MARGARET TODD

MARGARET TODD is a 1997 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in June 2026, along with 36 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 3 June 2026.

Built
1997
Last inspected
3 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WCY3642
463654
Flag
UNITED STATES
Maury page id
psix-463654

Inspections, by type

Years with a record 11 calendar years (2016–2026)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)106.1 ft × 23.0 ft × 8.3 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)106.1 ft × 23.0 ft × 8.3 ft
ITC tonnagegross 136 / net 53
BuilderSCHREIBER BOATS · ST AUGUSTINE, FL, UNITED STATES · built 1997
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHERRYFIELD, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it136 - Convention (Subpart B), Gross Ton
91 - Regulatory (Subpart C or D), Gross Ton
53 - Convention (Subpart B), Net Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

3 June 2026 COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8352531
10 April 2026 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8345824
2 September 2025 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8219635
3 September 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7985973
3 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7889421
6 September 2023 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7773096
6 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7555279
29 April 2022 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7417309
1 June 2021 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7164827
3 September 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7042665
7 May 2020 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6949597
9 April 2020 Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6940354
23 January 2020 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6894504
30 December 2019 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6880678
17 December 2019 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6875113
11 September 2019 DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6809973
5 September 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6792757
24 August 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6521388
20 March 2018 In-Service Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6374974
5 September 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6256813
7 June 2016 COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5894780
1 June 2016 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5893004
3 May 2016 Drydock Extension
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5874981

Deficiency record · 36

01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 3 September 2024 Resolved
Provide valid FCC Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2024
Resolved 30 September 2024
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 6 September 2022 Resolved
Found FCC safety and bridge to bridge certificates expired.
Action required: 705 - Other - as specified
Due 9 October 2022
Resolved 7 October 2022
Resolution: FCC Safety certificate issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 September 2022 Resolved
FWD Life ring not servicable / replace.
Action required: 705 - Other - as specified
Due 9 October 2022
Resolved 7 October 2022
Resolution: New life ring installed on vessel.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 1 June 2021 Resolved
FCC Safety Radio Certificate expired, renew certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 9 September 2022
Resolution: REISSUED DEF.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 September 2019 Resolved
Provide a magnetic compass at the operating station. Vsl had a digital compass only.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2019
Resolved 18 September 2019
Resolution: New compass installed
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 September 2019 Resolved
Provide a USCG Light list and charts for the operational area as described on the COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 18 September 2019
Resolution: Done
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 September 2019 Resolved
Apply the NOAA registration sticker to the EPRIB and put vessel's name on the EPRIB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 18 September 2019
Resolution: Done
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 5 September 2019 Resolved
Provide a Station Bill onboard and post it in a visible area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 18 September 2019
Resolution: Done
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2019 Resolved
Provide spanner wrenches at each fire hydrant.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 18 September 2019
Resolution: Wrench provided
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 September 2019 Resolved
Correctly label the electrical circuits on the distribution panels in the aft cabin.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 27 September 2019
Resolution: Done
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 5 September 2019 Resolved
Repair or replace 2 oars for the stbd life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 18 September 2019
Resolution: New oars provided
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 September 2019 Resolved
Repair the exterior surfaces of all life floats were the outer sheathing is cracked & worn prior to 01 May 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 3 September 2020
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2019 Resolved
Repair or replace the Mizzen boom spar prior to 01 May 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 7 May 2020
Resolution: Received photos and statement of repairs completed by O/O [name withheld] .
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2019 Resolved
Address the jaws on the main gaff prior to 01 MAY 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 7 May 2020
Resolution: Received photos and statement of repairs completed by O/O [name withheld] .
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2019 Resolved
Address the peak eye of the inner job prior to 01 MAy 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 16 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2019 Resolved
Secure the electrical cables every 24" to the overhead in the forward hold.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 27 September 2019
Resolution: Corrected
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 September 2019 Resolved
Weatherproff the electrical conncections for the bilge pump, forward of the main engine.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 27 September 2019
Resolution: Complteted
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 5 September 2019 Resolved
Provide a means of determining when the sewage holding tanks are at 3/4 full.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 27 September 2019
Resolution: Done
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 5 September 2019 Resolved
Repair or replace the gauges for the main engine at the operating station, the oil pressure and water temperature gauges were unreadable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 17 October 2019
Resolution: Corrected
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 September 2018 Resolved
High water alarms for steering compartment failed to indicate an audible tone when tested. Prove proper operation of alarm audible tone.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 12 September 2018
Resolution: Replaced loose connection in wiring.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 September 2018 Resolved
Life floats are required to be arranged to float free. Painter lines were found tangled in line painter cage due to cages being damaged from original configuration. Prove sea painter lines stored in a float free arrangement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 12 September 2018
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 September 2018 Resolved
EPIRB is required to be tested and logged monthly to prove operation. Conduct and log monthly test to prove operation of EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 September 2018
Resolved 4 September 2018
Resolution: Conducted sat test of EPIRB.
Sail Rigging › Stays/Shrouds › Clevis Pins and Cotter Pins
Issued 20 March 2018 Resolved
Foremast Inner Froe stay bail was found spring outward and placing attachment cotter pins in shear causing pins to fail. Correct fairlead on bail to mast connections to prevent assonated connection hardware from remaining in shear.
Action required: 10 - Deficiency Rectified
Due 30 April 2018
Resolved 2 April 2018
Resolution: Bail was removed and lead to load corrected to remove tension from cotter pins.
Sail Rigging › Running Rigging › Blocks
Issued 20 March 2018 Resolved
Jib turning block eye bolts were found pulling through attachment points on gunnel. Provide backings for jib turning blocks (04).
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 1 May 2018
Sail Rigging › Stays/Shrouds › Terminals/End Fittings
Issued 20 March 2018 Resolved
Port Whiskerstay connection shackle located on hull was found improperly installed (shackle pin was not completely threaded) and frozen. Install shackle/pin per manufacture instructions.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 1 May 2018
Resolution: Shackle pin was removed, serviced, and re installed correcly.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 March 2018 Resolved
Provide metal supports for cable runs in machinery space.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 1 May 2018
Fire Fighting › Fire Main › Condition
Issued 20 March 2018 Resolved
Metal hangers for fire main piping were found wasted. Replace hangers to original scantling.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 1 May 2018
Communications › Radio Communications › EPIRB
Issued 5 September 2017 Resolved
Master was not conducting monthly tests and logging results as required by 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Due 5 September 2017
Resolved 5 September 2017
Resolution: Conducted sat test of EPIRB and logged results in ships log.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 September 2017 Resolved
Master could not produce a FCC Safety Radio Certificate to proved proper installation and operation of VHF Radio. Provided FCC Safety Radio Certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 14 September 2017
Stability › Incline Test › General
Issued 5 September 2017 Resolved
A copy of the approved sail plan required by vessels stability letter dated 19 Oct 2012 was not onboard. Provide a copy of the Coast Guard approved sail plan dated June 10, 1998, onboard the vessel for masters reference.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 18 September 2017
Engineering › Bilge Water Management System › Strainer
Issued 5 September 2017 Resolved
Excessive amounts of debris and material are located in bilge pockets in way of suction strainers. This could cause a failure of the bilge water removal system during an emergency. Remove all debris and excessive material from all bilge pockets around suction strainers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 18 September 2017
Engineering › Bilge Water Management System › Pump
Issued 5 September 2017 Resolved
Flexible, nonmetallic hose used to connect bilge pump to suction manifold (vital system) is not SAE J1942 standard hose. Replace hoes with SAE J1942 and make connections IAW 46 CFR 182.720.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 18 September 2017
Sail Rigging › Mast Step › Base
Issued 5 September 2017 Resolved
No documentation could be produced to show a complete inspection of the three most fwd masts of the vessel to include the step and standing rigging. Un-stepping of a mast and down rigging all standing rigging is a key component to insure structural integrity. Un-step the three most fwd masts and make the associated standing rigging and mast steps available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 1 June 2018
Resolution: ddx
Lifesaving › Lifefloat › Lifeline
Issued 5 September 2017 Resolved
Life float's located on aft deck had worn retroreflective tape and frayed life lines. Replace retroreflective tape and lifelines to original condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 18 September 2017
Lifesaving › Lifebuoys › Serviceable
Issued 5 September 2017 Resolved
Ringbouy located on port side was found unserviceable condition. Replace with new buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 18 September 2017
Fire Fighting › Fire Main › Condition
Issued 7 June 2016 Resolved
Repair / replace fire main suction line, remove soft patch temp repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 5 July 2016
Resolution: pipe with soft patch and 6" section of hull replaced.

Ownership record