AMAZING GRACE

AMAZING GRACE is a 1969 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1985, most recently in May 2026, along with 85 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 5 May 2026.

Built
1969
Last inspected
5 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WSK2143
Flag
UNITED STATES
367020720
Maury page id
psix-46372

Inspections, by type

…with no type recorded5
Years with a record 39 calendar years (1985–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.5 ft × 17.3 ft × 5.8 ft
Registered tonnagegross 29 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · PALATKA, FL, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Regulatory (Subpart C or D), Gross Ton
20 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WSK2143MMSI 367020720 · active · compulsorily equipped · granted 28 February 2025, expires 27 February 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 65

5 May 2026 COI Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8367417
10 July 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090925
20 March 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087868
11 July 2024 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7964191
12 June 2024 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7873634
16 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7644952
3 April 2023 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7623130
7 July 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411372
15 April 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7150966
23 March 2021 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161257
14 July 2020 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6904150
16 July 2019 DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637827
5 April 2019 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6638538
27 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6524371
28 June 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375286
22 June 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105789
17 March 2017 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6101642
31 May 2016 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829904
21 March 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4820342
17 February 2012 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4246461
6 December 2011 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4202687
1 February 2011 COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3937147
2 April 2009 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3416160
28 May 2008 Deficiency Check · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3171114
23 May 2007 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2938465
4 April 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2899937
23 May 2006 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2628124
28 April 2005 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2345055
29 March 2005 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2316241
25 May 2004 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2076926
8 August 2003 Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1870121
16 July 2003 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1950968
24 June 2003 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1824595
20 March 2003 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1760011
25 June 2002 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1635493
14 June 2001 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1384796
14 May 2001 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1467756
14 July 2000 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1444377
6 July 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1436315
5 May 1999 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1397314
27 May 1998 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 792133
2 April 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1127420
14 August 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 114582
17 May 1996 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 858075
25 May 1995 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 870151
25 May 1995 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 874665
9 September 1994 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 869767
9 September 1994 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1178093
13 May 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1387591
19 May 1993 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1393946
5 May 1993 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1393947
13 May 1992 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 956994
24 April 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1262224
14 May 1991 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 911853
27 March 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 910308
8 May 1990 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1225441
24 May 1989 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 902203
4 May 1989 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1200495
15 December 1988 Drydock Extension
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1209332
13 May 1988 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1041011
4 May 1987 Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1022190
23 May 1986 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1298992
19 June 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 982318
24 May 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1291430
16 May 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1295327

Deficiency record · 85

05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 11 July 2024 Resolved
VHF radio did not have DSC capability connected. 47 CFR 80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 19 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2024 Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operating station to indicate high water level. The audible alarm for the engine space was not properly working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2023 Resolved
46 CFR 177.35-15 (a) Old-T - Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. The port engine belt drive for the PTO in way of the access to the engine room does not have a guard for rotating machinery. Install a guard on the port engine belt drive to the satisfaction of the Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2023
Resolved 22 June 2023
Resolution: Machinery guard installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2022 Resolved
Electrical equipment must be installed to protect crew from electrical hazards. Found a light underneath the bar area that was missing a cover. 46 CFR 183.200(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 October 2022
Resolution: Light was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 July 2022 Resolved
Each vessel must be equipped with at least two portable battery lights, located at the operating station and access to the machinery space. Provide two lights accordingly.46 CFR 183.420
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 October 2022
Resolution: Flashlights were provided in the spaces required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Found 09 lifejackets wasted/unrepairable; crew replaced 09 in kind, cleared. 10C. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2022
Resolved 7 July 2022
Resolution: Replaced in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 May 2021 Resolved
Each fixed bilge pump must be self priming with a minimum capacity of 25 GPM. Bilge pumps could not obtain suction.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Vessel representative replaced impeller and obtained suction to test all bilge pumps.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 May 2021 Resolved
Each battery must have connections made to battery terminals with permanent type connectors. Battery cables are loose and cannot be tightened any further.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Battery cables were fixed and allowed to be tightened all the way.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 10 May 2021 Resolved
A manned oceangoing ship of 40 feet or more that is documented and engaged in commerce must have a garbage management plan. Vessel does not have a garbage management plan.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Vessel representative created a waste management plan.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 May 2021 Resolved
Each vessel on a Lakes, Bays, and Sounds route must have 3 red hand flares and 3 orange smoke distress signals, or subsitute as allowed in the CFR. Vessel only has 4 red hand flares total onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Vessel representative obtained 2 more red hand flares for a total of 6.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021 Resolved
A vessel must carry a first aid kit approved under 160.041 or a kit with equivalent contents and instructions. First aid kit has expired medicine in it.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Vessel representative obtained unexpired asprin and burn cream.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021 Resolved
An adult life jacket must be provieded for each person carried on board a vessel. Vessel is short 9 adult life jackets as per their COI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Vessel rep obtained and marked additional adult lifejackets for a total onboard of 89. (COI requires 88 adult life jackets.)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2020 Resolved
First Aid kit had expired solution/medication.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 21 July 2020
Resolution: New first aid kit purchased
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2020 Resolved
Passenger count not marked for 01 deck
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 14 July 2020
Resolution: Passenger count posted on stairwell
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 16 July 2019 Resolved
Seat back on upper deck missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2019
Resolved 24 July 2019
Resolution: Hardware replaced / installed, seat back repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019 Resolved
Clean battery cable connections of excessive corrosion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2019
Resolved 17 July 2019
Resolution: Cleaned and maintenance of battery connections.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2019 Resolved
Install fire missing bracket for extinguisher in bar area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 July 2019
Resolved 17 July 2019
Resolution: Bracket installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 28 September 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 June 2017 Resolved
Repair snack bar bilge alarm light. Light is not functioning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 29 June 2017
Communications › Audible Communications › Bell
Issued 22 June 2017 Resolved
Provide an 8" bell as per nav rules.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 29 June 2017
Engineering › Bilge Water Management System › Piping
Issued 22 June 2017 Resolved
Make permanent repairs to bilge piping leading to lazarette. Piping was cracked in void fwd of lazarette.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2017
Resolved 22 June 2017
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 June 2017 Resolved
Provide lifejacket donning placards for all types of jackets carried.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 29 June 2017
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 31 May 2016 Resolved
Provide newest edition of Nav Rules book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 16 June 2016
Resolution: Provided newest edition of Nav Rules book.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2016 Resolved
Ammonia Inhalents, eye flush and dressing pack, burn gel, and aspirn are expired. Provide new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 16 June 2016
Resolution: Provided updated contents required in first aid kit.
Navigation › Piloting/Steering › Marine Charts
Issued 19 June 2014 Resolved
Provide current charts, LNM and light list.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 24 June 2014
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 19 June 2014 Resolved
Provide current Marine Radio Operators permit
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 24 June 2014
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 19 June 2014 Resolved
Properly label childrens life jackets.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 24 June 2014
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 June 2014 Resolved
Replace extinguished bilge high level alarm light.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 24 June 2014
Lifesaving › Hand Flares › Not on Board
Issued 19 June 2014 Resolved
Provide three red flares. Vessel restricted to daylight operations only.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 24 June 2014
Operations/Management › Drills/Instruction › Fire
Issued 19 June 2014 Resolved
Create SOP for fire pump operation.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 24 June 2014
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 17 February 2012 Resolved
Relabel the upper deck with the lower passenger count (36 persons).
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 1 June 2012
Resolution: [name withheld]
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 February 2012 Resolved
Renew all outdated items in the first aid kit.
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 1 June 2012
Resolution: [name withheld]
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 17 February 2012 Resolved
Properly replace the fuel vent screens P & S.
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 1 June 2012
Resolution: [name withheld]
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 February 2011 Resolved
B-II extinquishers mounted in the engine room and passenger salon have no belly band to prevent excess motion and wear.
Action required: 705 - Other - as specified
Due 15 June 2011
Resolved 16 June 2011
Resolution: New B-II extinquisher mounts installed with belly bands to prevent excess motion.
Documentation › Markings/Placards › Capacity Marking
Issued 28 May 2008 Resolved
Label upper deck for maximum passengers allowed
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 25 June 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 May 2008 Resolved
Label quantity of adult and child life preservers iwo storage locations.
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 25 June 2008
Construction/Loadline › Structures › Door
Issued 28 May 2008 Resolved
Repair/Replace cracked window on portside door at in pilothouse
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 8 July 2008
Resolution: Window replaced in-kind
Construction/Loadline › Structures › Scuttle
Issued 28 May 2008 Resolved
Repair/Replace broken hatch to fwd compartment
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 25 June 2008
Fire Fighting › Fire Main › Valves
Issued 28 May 2008 Resolved
Replace plastic valve in fire main with a metallic valve
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 25 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2008 Resolved
Remove nonstandard electrical cord iwo inverter and replace with marine grade cable
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 25 June 2008
Documentation › Certificates/Documents › FCC SSL
Issued 24 May 2007 Resolved
Prove proper safety certificate for FCC compliance of radio.
Action required: 705 - Other - as specified
Due 6 June 2007
Resolved 6 June 2007
Resolution: Witnessed up to date cert on board. All sat.
Stability › Watertight Integrity › General
Issued 24 May 2007 Resolved
Install appropriate bilge high level alarm in the shaft alley bilge (snack bar space).
Action required: 705 - Other - as specified
Due 6 June 2007
Resolved 6 June 2007
Resolution: Witnessed and tested newly installed bilge high level alarm. All sat.
Construction/Loadline › Hull › Longitudinal Frame
Issued 4 April 2007 Resolved
Wasted longitudinal frames including web in second compartment extending to keel, IWO forward bulkhead. Crop and re-new.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 17 April 2007
Construction/Loadline › Hull › Stiffener
Issued 4 April 2007 Resolved
Wasted stiffeners in lazarette along transom. Crop and re-new
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 17 April 2007
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 4 April 2007 Resolved
Repair/replace fractured sewage tank.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 4 May 2007
Construction/Loadline › Structures › Ventilators
Issued 4 April 2007 Resolved
Wasted deck vents on main deck IWO aft bulkhead. Crop and re-new or fabricate as new.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 17 April 2007
Construction/Loadline › Hull › Hull Plating
Issued 4 April 2007 Resolved
Wasted hull plating, 4-5" diameter internal of aft port rub rail. Crop and re-new.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 19 April 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 23 May 2006 Resolved
Provide 12 adult PFD's.
Action required: 705 - Other - as specified
Due 23 May 2006
Resolved 24 May 2006
Resolution: PFD''s were purchased for the vessel.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 April 2005 Resolved
Provide deck railings on the bow I.A.W. 46 CFR 177.35-1 (C) (old T)
Due 15 July 2005
Resolved 24 May 2006
Resolution: Inspected railing - sat.
Engineering › Bilge Water Management System › Not Operational
Issued 28 April 2005 Resolved
Provide an operational bilge system for all required compartments. Bilge system was found to be inoperative for four of five compartments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 April 2005 Resolved
Provide high level alarm I.A.W 46 CFR 182.530 for aft steering compartment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2005
Fire Fighting › Means of Escape › Blocked
Issued 28 April 2005 Resolved
Remove carpet from above E/R escape and label both sides of escape.
Due 23 May 2005
Resolved 20 May 2005
Engineering › Steering Gear System › Chain
Issued 28 April 2005 Resolved
Re-install chain utilized as rudder stops in steering compartment.
Due 23 May 2005
Resolved 22 May 2005
Engineering › Fuel Oil Service System › Valve
Issued 28 April 2005 Resolved
Properly label emergency F/O shut-off valves
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Lifesaving › Hand Flares › Storage
Issued 28 April 2005 Resolved
Remove old flares and properly stow new flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Personnel › Training › Familiarization Training
Issued 28 April 2005 Resolved
Perform familiarization training on emergency equipment and procedures for all crewmembers. Ensure training is performed at least quarterly I.A.W. 46 CFR 185.420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Resolution: Captain, Owner, and crewmwmbers unaware or training requirements and indicated annual training was the normal
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 April 2005 Resolved
Provide retro-reflective material for all life rings
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Documentation › Certificates/Documents › FCC SSL
Issued 28 April 2005 Resolved
Provide FCC safety certificate
Due 29 May 2005
Resolved 23 May 2005
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 28 April 2005 Resolved
Provide a signed stability letter
Due 15 June 2005
Resolved 24 May 2006
Resolution: Vessel permanent file has same stability letter - unsigned.
Stability › Watertight Integrity › General
Issued 28 April 2005 Resolved
Provide latching device and ensure weathertight hatch on bow.
Due 5 June 2005
Resolved 23 May 2005
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 April 2005 Resolved
Provide and display EAP hotline contact number.
Due 25 May 2005
Resolved 20 May 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 April 2005 Resolved
Replace MDE machinery belt guards
Condition: Improper Installation
Due 25 May 2005
Resolved 20 May 2005
Documentation › Certificates/Documents › FCC SSL
Issued 28 April 2005 Resolved
Ensure at least one crew member has a current FCC operators permit prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 April 2005 Resolved
Ensure all pages of COI are posted
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 April 2005 Resolved
Ensure all plastic deck chairs are properly marked with installation date and inspected regularly for deterioration I.A.W MSO Providence special note included with vessel file.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Construction/Loadline › Penetrations › Gasket
Issued 29 March 2005 Resolved
Replace gasket material on void space and fuel tank compartment hatches.
Condition: Improper/Lack of Maintenance
Due 1 May 2005
Resolved 3 May 2005
Resolution: Received fax receipt for gasket material.
Lifesaving › Lifefloat › Lifeline
Issued 25 May 2004 Resolved
Secure the life line completely around the life ring.
Due 7 June 2004
Resolved 24 June 2004
Stability
Issued 24 June 2003 Resolved
Re-stencil upper deck for 42 passengers maximum, as per COI.
Due 8 July 2003
Resolved 10 July 2003
Electrical
Issued 24 June 2003 Resolved
Provide cover for electrical box located between engines.
Due 8 July 2003
Resolved 30 June 2003
Lifesaving › Hand Flares
Issued 24 June 2003 Resolved
Provide three (3) orange day smoke signals. Vessel is restricted to not more than 1,000 feet from shore until cleared. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Due 8 July 2003
Resolved 26 June 2003
Resolution: Placed new flares on vessel.
Lifesaving › Lifejacket/PFD (Type I)
Issued 24 June 2003 Resolved
Replace and re-retro tape life jackets. Restricted to carrying 54 passengers until cleared. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Due 8 July 2003
Resolved 26 June 2003
Resolution: Life jackets were replaced and retro taped and stenciled. Visually inspected the retro taped lifejackets and received invoice from Old Port for new lifejackets. (50 total)
Engineering › Fuel Oil Service System
Issued 24 June 2003 Resolved
Address swollen fuel line in way of port engine. LEGACY COMPONENT DESC: Hose
Due 8 July 2003
Resolved 26 June 2003
Resolution: Fuel line was replaced.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 June 2002 Resolved
Vessel charts were not up to date and corrected. No Lightlist and Coast Pilot on board.
Condition: Improper/Lack of Maintenance
Due 2 July 2002
Resolved 8 July 2002
Resolution: CHARTS AND PUBS CORRECTED AND PROCURED. ITEMS ONBOARD
Lifesaving › Lifejacket/PFD (Type IV) › Retroreflective Material
Issued 25 June 2002 Resolved
VSL HAD FADED/INEFFECTIVE RETRO TAPE ON RING BUOYS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2002
Resolution: INSTALLED NEW RETRO TAPE TO RING BUOYS
Fire Fighting › Fire Main › Valves
Issued 25 June 2002 Resolved
VSL FIREMAIN CUTOUT VALVE AT HOSE, WAS DIFFICULT TO OPERATE AND IN POOR MATERIAL CONDITION. REPLACE VALVE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2002
Resolution: VALVE REPLACED AND OPERABLE.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 June 2002 Resolved
VARIOUS MEDICINES IN FIRST AID KIT OUTDATED
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2002
Resolution: REPLACED WITH NEW MEDICINES.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 June 2002 Resolved
CONDUIT PIPING LEADING TO STERN LIGHT WAS WASTED/FRACTURED EXPOSING ELECTRICAL WIRES. CONDUIT LOCATED ON FANTAIL OVERHEAD APPRX. 6 FEET FROM STERN LIGHT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2002
Resolution: WASTED CONDUIT REPLACED AND SECURED TO OVERHEAD.
Engineering › Steering Gear System › Rudder
Issued 25 June 2002 Resolved
RUDDER STOCK TILLER ARM WAS NOT DOUBLE NUTTED.
Action required: 705 - Other - as specified
Resolved 8 July 2002
Resolution: TILLER ARM DOUBLE NUTED.
Unknown
Issued 14 June 2001 Resolved
Replace Firehouse with a type that has an inner rubber tube, plies of braided fabric and an outter cover of rubber.
Condition: Unknown
Due 28 June 2001
Resolved 18 July 2001
Unknown
Issued 14 June 2001 Resolved
Add "C" clamps to engine cooling hose, lower connection, on both engines.
Condition: Unknown
Due 28 June 2001
Resolved 18 July 2001
Documentation
Issued 14 June 2001 Resolved
PROVIDE LOCAL COAST PILOT AND LIGHT LIST.
Condition: Unknown
Due 28 June 2001
Resolved 21 August 2001
Unknown
Issued 14 June 2001 Resolved
Post maximum passenger count for upper deck.
Condition: Unknown
Due 28 June 2001
Resolved 18 July 2001
Unknown
Issued 14 June 2001 Resolved
Separate stowage of adult and child life jackets. Stencil compartment separation on life jacket stowage.
Condition: Unknown
Due 28 June 2001
Resolved 18 July 2001
Lifesaving
Issued 16 May 1985 Resolved
PROVIDE A TOTAL OF 102 ADULT PFD'S.
Condition: Unknown
Due 16 May 1985
Resolved 16 May 1985
Construction/Loadline
Issued 16 May 1985 Resolved
PROVIDE ADEQUATE DOGGING DEVICE FOR ESCAPE HATCH IN ENGINE ROOM. DEVICE MUST BE CAPABLE OF OPERATION FROM BOTH SIDES.
Condition: Unknown
Due 16 May 1985
Resolved 16 May 1985