Records from 2016 to 2026. Most recent: inspection, 5 May 2026.
Inspection history · 18
5 May 2026
COI Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8367417
10 July 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090925
20 March 2025
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087868
11 July 2024
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7964191
12 June 2024
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7873634
16 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7644952
3 April 2023
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7623130
7 July 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411372
15 April 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7150966
23 March 2021
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161257
14 July 2020
Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6904150
16 July 2019
DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637827
5 April 2019
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6638538
27 August 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6524371
28 June 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375286
22 June 2017
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105789
17 March 2017
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6101642
31 May 2016
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829904
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 11 July 2024
Resolved
VHF radio did not have DSC capability connected.
47 CFR 80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 19 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2024
Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operating station to indicate high water level. The audible alarm for the engine space was not properly working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 18 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2023
Resolved
46 CFR 177.35-15 (a) Old-T - Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. The port engine belt drive for the PTO in way of the access to the engine room does not have a guard for rotating machinery. Install a guard on the port engine belt drive to the satisfaction of the Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2023
Resolved 22 June 2023
Resolution: Machinery guard installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2022
Resolved
Electrical equipment must be installed to protect crew from electrical hazards. Found a light underneath the bar area that was missing a cover. 46 CFR 183.200(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 October 2022
Resolution: Light was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 July 2022
Resolved
Each vessel must be equipped with at least two portable battery lights, located at the operating station and access to the machinery space. Provide two lights accordingly.46 CFR 183.420
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 13 October 2022
Resolution: Flashlights were provided in the spaces required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Found 09 lifejackets wasted/unrepairable; crew replaced 09 in kind, cleared. 10C. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2022
Resolved 7 July 2022
Resolution: Replaced in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 May 2021
Resolved
Each fixed bilge pump must be self priming with a minimum capacity of 25 GPM. Bilge pumps could not obtain suction.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Vessel representative replaced impeller and obtained suction to test all bilge pumps.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 May 2021
Resolved
Each battery must have connections made to battery terminals with permanent type connectors. Battery cables are loose and cannot be tightened any further.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Battery cables were fixed and allowed to be tightened all the way.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 10 May 2021
Resolved
A manned oceangoing ship of 40 feet or more that is documented and engaged in commerce must have a garbage management plan. Vessel does not have a garbage management plan.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Vessel representative created a waste management plan.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 May 2021
Resolved
Each vessel on a Lakes, Bays, and Sounds route must have 3 red hand flares and 3 orange smoke distress signals, or subsitute as allowed in the CFR. Vessel only has 4 red hand flares total onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Vessel representative obtained 2 more red hand flares for a total of 6.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021
Resolved
A vessel must carry a first aid kit approved under 160.041 or a kit with equivalent contents and instructions. First aid kit has expired medicine in it.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Vessel representative obtained unexpired asprin and burn cream.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021
Resolved
An adult life jacket must be provieded for each person carried on board a vessel. Vessel is short 9 adult life jackets as per their COI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Vessel rep obtained and marked additional adult lifejackets for a total onboard of 89. (COI requires 88 adult life jackets.)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2020
Resolved
First Aid kit had expired solution/medication.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 21 July 2020
Resolution: New first aid kit purchased
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2020
Resolved
Passenger count not marked for 01 deck
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 14 July 2020
Resolution: Passenger count posted on stairwell
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 16 July 2019
Resolved
Seat back on upper deck missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2019
Resolved 24 July 2019
Resolution: Hardware replaced / installed, seat back repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019
Resolved
Clean battery cable connections of excessive corrosion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2019
Resolved 17 July 2019
Resolution: Cleaned and maintenance of battery connections.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2019
Resolved
Install fire missing bracket for extinguisher in bar area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 July 2019
Resolved 17 July 2019
Resolution: Bracket installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 28 September 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 June 2017
Resolved
Repair snack bar bilge alarm light. Light is not functioning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 29 June 2017
Communications › Audible Communications › Bell
Issued 22 June 2017
Resolved
Provide an 8" bell as per nav rules.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 29 June 2017
Engineering › Bilge Water Management System › Piping
Issued 22 June 2017
Resolved
Make permanent repairs to bilge piping leading to lazarette. Piping was cracked in void fwd of lazarette.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2017
Resolved 22 June 2017
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 June 2017
Resolved
Provide lifejacket donning placards for all types of jackets carried.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 29 June 2017
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 31 May 2016
Resolved
Provide newest edition of Nav Rules book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 16 June 2016
Resolution: Provided newest edition of Nav Rules book.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2016
Resolved
Ammonia Inhalents, eye flush and dressing pack, burn gel, and aspirn are expired. Provide new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 16 June 2016
Resolution: Provided updated contents required in first aid kit.