Records from 1984 to 2020. Most recent: inspection, 15 December 2020.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 58
15 December 2020
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7111866
11 July 2012
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4366046
27 January 2009
Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3400673
29 April 2008
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3194787
17 December 2007
Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3143683
12 June 2007
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2974858
19 March 2007
Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2892062
28 March 2006
Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2617467
5 May 2005
Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2350816
30 March 2004
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2037551
4 February 2003
Hull Examination · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1743769
28 October 2002
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1697064
27 September 2002
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1697073
26 March 2002
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1494629
11 April 2001
Hull Examination · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1457911
11 April 2000
Deficiency Check · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1395409
3 April 2000
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1381843
30 March 1999
Deficiency Check · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1399074
26 February 1999
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1455675
19 June 1998
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 793569
23 March 1998
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 787592
18 September 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 642920
22 August 1997
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 788002
19 August 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 178708
19 August 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 213195
22 April 1997
Plan Review "T" Boat
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 785573
27 March 1997
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1102072
13 March 1997
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1096017
24 April 1996
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 842348
5 April 1996
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1080928
22 March 1996
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1080916
12 March 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1430156
15 March 1995
Hull Examination · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1132852
5 April 1994
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 856604
22 March 1994
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 855876
24 March 1993
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 836682
5 March 1993
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 840826
28 May 1992
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 955757
17 March 1992
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 961797
23 December 1991
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1269032
27 August 1991
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1251121
27 March 1991
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1227645
8 January 1991
Examination of Repairs
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 907936
28 August 1990
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 913966
29 March 1990
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1239971
12 April 1989
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1207867
6 January 1989
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1351962
16 August 1988
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1344588
29 June 1988
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1030875
28 March 1988
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 994075
21 September 1987
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1314769
1 June 1987
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1003352
17 April 1987
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1020547
19 June 1986
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 996709
27 May 1986
Re-Inspection
Physical examination · THE UNKNOWN UNIT · Activity 1298664
11 March 1986
Credit Drydock
Administrative · THE UNKNOWN UNIT · Activity 996469
22 April 1985
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1287425
18 April 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 974888
Fire Fighting › Fire Pumps › Arrangement
Issued 11 July 2012
Resolved
Attending Inspectors noted excessive play in vessels fire pump belt drive (V-belt).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2012
Resolved 8 August 2012
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 11 July 2012
Resolved
Attending inspectors noted severe deterioration/wastage on portable fire extinguisher bracket located in forward vestibule (lower)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2012
Resolved 8 August 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 July 2012
Resolved
Attending inspectors noted that vessel's loading "gate" was not equipped with center rails (only upper and lower).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2012
Resolved 8 August 2012
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 11 July 2012
Resolved
Attending inspectors noted that vessels anchor chain thimble/shackle were severely worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2012
Resolved 8 August 2012
Construction/Loadline › Hull › Transverse Frame
Issued 11 July 2012
Resolved
Attending inspectors noted severe deterioration/rot on frame (angle) IWO Port Side FR#7 FWD of transom above the waterline. Attending inspectors required temp repairs until vessels next schedule drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2013
Resolved 17 June 2013
Construction/Loadline › Hull › Side Shell
Issued 11 July 2012
Resolved
Attending inspectors noted severe detioration/rot on side shell planking IWO FR #7 FWD of transom above waterline. Attending inspectors required temp repairs until vessels next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2013
Resolved 17 June 2013
Construction/Loadline › Hull › Bottom Plating
Issued 11 July 2012
Resolved
Attending inspectors noted severely detiorated/wasted fasteners on butt block (bottom planking) IWO FR #7 FWD of transom. Attending inspectors required temp repairs until vessels next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2013
Resolved 17 June 2013
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 29 April 2008
Resolved
Up date Charts and Pubs for the operating area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2008
Resolved 12 August 2009
Resolution: Charts and pubs were updated
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 29 April 2008
Resolved
Post emergency broadcast instructions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 May 2008
Resolved 12 August 2009
Resolution: Instructions were posted.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 12 June 2007
Resolved
Replace (2) - Adult life jackets (type I) due to retro; or renew retro with approved type
Action required: 705 - Other - as specified
Due 12 June 2007
Resolved 29 April 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 June 2007
Resolved
Replace line around body of life ring. 60' line was sat
Action required: 705 - Other - as specified
Due 12 July 2007
Resolved 29 April 2008
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 19 March 2007
Resolved
Submit proposal for proper rescue platform as identified by Sec NC CID note 07-01.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 29 April 2008
Lifesaving › Lifefloat › Lifeline
Issued 28 March 2006
Resolved
Replace line around life float as original, existing line is showing signs of age.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 28 April 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 March 2006
Resolved
Replace line 3-6ft connecting float light to lifering, attach using clip. Existing line showing signs of aging.
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 28 April 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 March 2006
Resolved
Fireboy mannual release cable is missing securing pin at bottle. If pulled cable may not activate Fireboy as designed.
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 28 March 2006
Resolution: Vessel Rep contacted contractor who performed inspection to repair.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 March 2006
Resolved
Replace missing light globes in engine room
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 28 April 2006
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 28 March 2006
Resolved
Install covers in engine room in way of port and stbd side. Existing covers are missing.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 28 April 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 March 2006
Resolved
Replace stern light lense due to characteristics of lense are effected due to discoloration from age. Lense range of visibility effected.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 28 April 2006
Electrical › Electric Supply System (service) › Battery Charger
Issued 28 March 2006
Resolved
Hard wire battery charger to batteries, existing condition using alagator clips
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 28 April 2006
Electrical › Electric Supply System (service)
Issued 27 September 2002
Resolved
Section of wiring located in the compartment forward of the engine compartment burnt due to fire caused by a worn engine exhaust pipe section.
Condition: Damaged By Earlier Event
Due 13 November 2002
Resolved 12 May 2003
Resolution: Wiring was replaced.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 27 September 2002
Resolved
A wasted section of exhaust piping in the compartment forward of the engine compartment allowed hot exhaust to escape causing a fire. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 13 November 2002
Resolved 12 May 2003
Resolution: Exhaust piping replaced.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 27 September 2002
Resolved
Three CO2 bottles were used to extinquish the fire and need to be recharged/replaced. LEGACY COMPONENT DESC: Service
Condition: Unknown
Due 13 November 2002
Resolved 12 May 2003
Resolution: Extinguishers were replaced.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 26 March 2002
Resolved
Provide proof of service for portable fire extinguishers. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Resolution: Extinguishers serviced.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 March 2002
Resolved
Provide proof of service for fixed Halon System serving engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Resolution: System serviced and tested.
Documentation › Certificates/Documents › Stability Letter
Issued 26 March 2002
Resolved
Provide and post Stability Letter.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Resolution: Stability Letter provided and posted.
Documentation › Certificates/Documents › FCC SSL
Issued 26 March 2002
Resolved
Provide copy of FCC Safety Radio Telephone Certificate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Resolution: FCC Certificate provided.
Lifesaving › Lifejacket/PFD (General)
Issued 26 March 2002
Resolved
Provide and post copy of lifejacket donning placard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Resolution: Placard provided and posted.
Deck/Cargo
Issued 26 March 2002
Resolved
Repaint name of vessel on stbd bow. LEGACY COMPONENT DESC: Hull
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Resolution: Name of vessel painted on stbd bow.
Documentation
Issued 11 April 2000
Resolved
PROVIDE FCC ISSUED SAFETY RADIO CERTIFICATE. VESSEL IS NOT TO OPERATE UNTILPROVIDED.
Condition: Unknown
Due 13 April 2000
Resolved 14 April 2000
Documentation
Issued 23 March 1998
Resolved
PROVIDE RECORDS OF LIFESAVING, FIREFIGHTING, CREW TRAINING AND DRILLS AS REQUIRED BY 46 CFR 185.520-524 AND 46 CFR 185.702, NO LATER THAN 30 MARCH 1998.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Fire Fighting
Issued 23 March 1998
Resolved
PROVIDE FIXED FIREFIGHTING SYSTEM IN ENGINE ROOM NO LATER THAN 11 MARCH 1999. INSTALLATION SHALL BE TO THE SATISFACTION OF THE COGNIZANT OCMI AND ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Construction/Loadline
Issued 22 August 1997
Resolved
REPAIR/REPLACE FRACTURED PLANKS (2) LOCATED IN WAY OF PORT & STBD BOW, WHERE TEMPORARY REPAIR EXISTS.
Condition: Unknown
Due 22 August 1997
Resolved 26 August 1997
Construction/Loadline
Issued 27 March 1997
Resolved
REMOVE BOTTOM PLANK LOCATED IN WAY OF PORT SIDE, 2ND PLANK FROM GARBOARD, 3RD FRAME BAY FROM STERN, FOR FURTHER EVALUATION BY CG INSPECTOR. REQUIREMENT TO BE COMPLETED AT VESSEL'S NEXT ROUTINE HAUL-OUT, BUT NO LATERTHAN 31 AUGUST 1997.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Construction/Loadline
Issued 27 March 1997
Resolved
REPAIR/REPLACE STRIP PLANK IN WAY OF PORT SIDE SHEER STRAKE - FWD.
Condition: Unknown
Due 27 March 1997
Resolved 1 April 1997
Construction/Loadline
Issued 27 March 1997
Resolved
REPAIR/REPLACE STRIP PLANK IN WAY OF STBD SIDE SHEER STRAKE - MIDSHIP.
Condition: Unknown
Due 27 March 1997
Resolved 1 April 1997
Construction/Loadline
Issued 27 March 1997
Resolved
REPAIR/REPLACE STRIP PLANK LOCATED ON STBD SIDE, IN WAY OF BOTTOM PORTION OF FLARE.
Condition: Unknown
Due 27 March 1997
Resolved 1 April 1997
Construction/Loadline
Issued 27 March 1997
Resolved
REPAIR/REPLACE FRAME (2ND FROM STERN IN ENG COMPARTMENT) ON PORT SIDE, WHERE WASTED.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Construction/Loadline
Issued 27 March 1997
Resolved
REPAIR/REPLACE PLANK LOCATED ON PORT SIDE OF ENGINE COMPARTMENT, 10TH FRM FROM FWD, WHERE WASTED.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Construction/Loadline
Issued 27 March 1997
Resolved
REFASTEN BUTT BLOCK LOCATED IN ENGINE COMPARTMENT ON PORT SIDE, 7TH FRM FROM FWD.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Construction/Loadline
Issued 27 March 1997
Resolved
REFASTEN BOTTOM PORTION OF FRAME #7 (FROM FWD IN ENGINE COMPARTMENT), LOCATED ON PORT SIDE.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Electrical
Issued 27 March 1997
Resolved
PRIOR TO OPERATING WITH PASSENGERS, SUBMIT COMPLETE SCHEMATIC OF NEW WIRINGINSTALLATION FOR CG APPROVAL.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Construction/Loadline
Issued 27 March 1997
Resolved
REFASTEN STERN AREA (PORT & STBD) FROM 3RD FRAME FWD OF RUDDER POST, AFT.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Engineering
Issued 13 March 1997
Resolved
PRIOR TO OPERATION WITH PASSENGERS, CONDUCT SATISFACTORY UNDERWAY OPERATIONOF VESSEL IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 20 March 1997
Resolved 19 March 1997
Navigation
Issued 13 March 1997
Resolved
PRIOR TO OPERATION WITH PASSENGERS, DEMONSTRATE PROPER OPERATION OF THE MAIN ENGINE SHAFT RPM GUAGE AT VESSEL CONTROL STATION.
Condition: Unknown
Due 20 March 1997
Resolved 19 March 1997
Documentation
Issued 13 March 1997
Resolved
PRIOR TO OPERATION WITH PASSENGERS, PROVIDE VALID FCC RADIO STATION LICENSE.
Condition: Unknown
Due 20 March 1997
Resolved 19 March 1997
Fire Fighting
Issued 13 March 1997
Resolved
PRIOR TO OPERATION WITH PASSENGERS, PROVIDE EVIDENCE OF CHARGE ON BII EXTINGUISHER ON PORT SIDE OF ENGINE ROOM ACCESS DOOR, BELOW DECK, AS EXTINGUISHER HAS NO GUAGE.
Condition: Unknown
Due 20 March 1997
Resolved 19 March 1997
Fire Fighting
Issued 13 March 1997
Resolved
PRIOR TO OPERATION WITH PASSENGERS, DEMONSTRATE PROPER OPERATION OF THE FIRE PUMP/FIRE FIGHTING SYSTEM IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 20 March 1997
Resolved 19 March 1997
Construction/Loadline
Issued 13 March 1997
Resolved
PRIOR TO OPERATION OF BILGE PUMPING SYSTEMS, REMOVE EXCESS FUEL/OIL FROM THE VESSEL'S BILGES.
Condition: Unknown
Due 20 March 1997
Resolved 19 March 1997
Engineering
Issued 13 March 1997
Resolved
PRIOR TO OPERATION WITH PASSENGERS, COMPLETE RE-WRAPPING OF EXHAUST SYSTEMSABOVE MAIN DECK.
Condition: Unknown
Due 20 March 1997
Resolved 19 March 1997
Construction/Loadline
Issued 13 March 1997
Resolved
PRIOR TO OPERATION WITH PASSENGERS, DEMONSTRATE PROPER OPERATION OF FIXED BILGE PUMPING SYSTEM IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 20 March 1997
Resolved 19 March 1997
Deck/Cargo
Issued 13 March 1997
Resolved
PRIOR TO OPERATION WITH PASSENGERS, PROVIDE APPROPRIATE LENGTH OF ANCHOR LINE IN ACCORDANCE WITH GOOD MARINE PRACTICE.
Condition: Unknown
Due 20 March 1997
Resolved 19 March 1997
Electrical
Issued 13 March 1997
Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE COGNIZANT [name withheld] FOR NEW WIRING INSTALLATION._x001C_
Condition: Unknown
Due 14 March 1997
Resolved 19 March 1997
Construction/Loadline
Issued 13 March 1997
Resolved
PRIOR TO OPERATION WITH PASSENGERS, PLACE APPROVED TYPE STOP/CHECK VALVES OR STOP VALVES IN SERIES WITH CHECK VALVES IN BILGE OVERBOARD DISCHARGE LINES.
Condition: Unknown
Due 13 March 1997
Resolved 13 March 1997
Construction/Loadline
Issued 13 March 1997
Resolved
PRIOR TO OPERATION WITH PASSENGERS, COMPLETE OUTSTANDING DRYDOCK REQUIREMENTS (20FEB97) TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 March 1997
Resolved 13 March 1997
Navigation
Issued 22 March 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS, TIGHTEN RUDDER POST LEVER.
Condition: Unknown
Due 22 March 1996
Resolved 11 April 1996
Documentation
Issued 22 March 1996
Resolved
PRIOR TO OPERATING MORE THAN 1,000 FT FROM SHORE, PROVIDE VALID RADIO OPERATOR'S PERMIT.
Condition: Unknown
Due 22 March 1996
Resolved 11 April 1996
Construction/Loadline
Issued 22 March 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPAIR HULL DAMAGE IN WAY OF STARBOARD QUARTER, @ 12" ABOVE THE LOADED WATERLINE.
Condition: Unknown
Due 22 March 1996
Resolved 11 April 1996
Engineering
Issued 22 March 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE EMERGENCY FUEL SHUT OFF, AND LABEL SAME.
Condition: Unknown
Due 22 March 1996
Resolved 11 April 1996
Construction/Loadline
Issued 22 March 1996
Resolved
INSTALL STOP/CHECK VALVES ON BILGE LINES NO LATER THAN 04APR96.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Documentation
Issued 22 March 1996
Resolved
PRIOR TO VESSEL OPERATING, PROVIDE PROOF OF VALID DOCUMENTATION.
Condition: Unknown
Due 22 March 1996
Resolved 11 April 1996
Accommodation/Occupational Safety
Issued 22 March 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS, INSTALL ADDITIONAL RAIL COURSES AT BOW OR CLOSE AREA OFF TO PASSENGERS.
Condition: Unknown
Due 22 March 1996
Resolved 11 April 1996
Engineering
Issued 22 March 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDEGROUND FOR NEWLY INSTALLED FUEL TANK.
Condition: Unknown
Due 22 March 1996
Resolved 11 April 1996
Lifesaving
Issued 22 March 1996
Resolved
RELABEL PFD STOWAGE WITH CORRECT NUMBER AS REQUIRED BY COI.
Condition: Unknown
Due 5 April 1996
Resolved 11 April 1996
Engineering
Issued 22 March 1996
Resolved
INSTALL GUARD ON BELT DRIVEN FIRE PUMP NO LATER THAN 21APR96.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Engineering
Issued 22 March 1996
Resolved
INSTALL FLAME SCREEN ON FUEL TANK VENT.
Condition: Unknown
Due 5 April 1996
Resolved 11 April 1996
Engineering
Issued 22 March 1996
Resolved
REPLACE ENGINE ROOM VENT (WHERE WASTED), NO LATER THAN 21APR96.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Fire Fighting
Issued 15 March 1995
Resolved
PROVIDE 5 GPM HAND FIRE PUMP AS PER 46 CFR 180.10-5 PRIOR TO OPERATING VESSEL WITH PASSENGERS ONBOARD.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Documentation
Issued 22 March 1994
Resolved
PROVIDE VALID FCC RADIOTELEPHONE CERTIFICATE. VESSEL RESTRICTED TO NOT MORE THAN 1000 FEET FROM LAND UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Fire Fighting
Issued 22 March 1994
Resolved
PROVIDE PROPER MOUNTING BRACKETS FOR TWO, B-II CO2 EXTINGUISHERS, CAR DECK AND ENGINEROOM.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994
Resolved
REPLACE MALFUNCTIONING LIFE RING WATER LIGHT. VESSEL RESTRICTED TO DAYLIGHT OPERATIONS UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 25 March 1994
Resolved 25 March 1994
Engineering
Issued 22 March 1994
Resolved
RE-LAG PORT MAIN ENGINE EXHAUST AT MAIN DECK.
Condition: Unknown
Due 25 March 1994
Resolved 25 March 1994
Fire Fighting
Issued 17 March 1992
Resolved
HYDROSTATICALLY TEST PORTABLE CO2 FIRE EXTINGUISHERS.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Lifesaving
Issued 17 March 1992
Resolved
PROVIDE SIX ORANGE SMOKE SIGNALS ON BOARD VESSEL.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Construction/Loadline
Issued 27 August 1991
Resolved
RENEW ROTTED PLANKING ON THE MAIN DECK IN WAY OF DECK STANCIONS FOR RAILS. TEMPORARY REPAIRS AUTHORIZED AS DISCUSSED.
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Navigation
Issued 27 March 1991
Resolved
PROVE PROPER OPERATION OF INSTALLED UHF-FM RADIO ON CH-16.
Condition: Unknown
Due 27 March 1991
Resolved 27 March 1991
Construction/Loadline
Issued 6 January 1989
Resolved
RENEW RUBRAIL ACROSS TRANSOM & 3' ON PORT QUARTER. RENEW 3 DECK PLANKS AS MARKED AT STERN OF CAR DECK. RENEW SIDE PLANK AS MARKED ON STBD SIDE.
Condition: Unknown
Due 6 January 1989
Resolved 6 January 1989
Construction/Loadline
Issued 6 January 1989
Resolved
REPLACE 3 PLASTIC THRU HULL FITTINGS WITH METALIC FITTINGS.
Condition: Unknown
Due 6 January 1989
Resolved 6 January 1989
Construction/Loadline
Issued 6 January 1989
Resolved
FASTEN LOOSE DECK BEAM IN WAY OF ENGINE ROOM HATCH.
Condition: Unknown
Due 6 January 1989
Resolved 6 January 1989
Accommodation/Occupational Safety
Issued 29 June 1988
Resolved
RESECURE RAILING ON STARBOARD SIDE.
Condition: Unknown
Due 29 June 1988
Resolved 29 June 1988
Documentation
Issued 29 June 1988
Resolved
OBTAIN CURRENT FCC TELEPHONY CERTIFICATE.
Condition: Unknown
Due 29 June 1988
Resolved 29 June 1988
Electrical
Issued 29 June 1988
Resolved
LINE #1 BATTERY BOX WITH LEAD OR EQUIVALENT MATERIAL (SUCH AS FIBERGLASS).
Condition: Unknown
Due 29 June 1988
Resolved 29 June 1988
Engineering
Issued 29 June 1988
Resolved
PROVIDE KEY TO ACCESS FOR REMOTE FUEL SHUT-OFF.
Condition: Unknown
Due 29 June 1988
Resolved 29 June 1988
Fire Fighting
Issued 29 June 1988
Resolved
REPLACE SECTION OF PVC PIPING WITH METAL PIPING IN FIRE MAIN.
Condition: Unknown
Due 29 June 1988
Resolved 29 June 1988
Fire Fighting
Issued 29 June 1988
Resolved
PROPERLY SUPPORT ALL PIPING IN FIRE MAIN WITH PIPE HANGERS.
Condition: Unknown
Due 29 June 1988
Resolved 29 June 1988
Documentation
Issued 29 June 1988
Resolved
PLACE ORIGINAL OF DOCUMENT ABOARD VESSEL.
Condition: Unknown
Due 29 June 1988
Resolved 29 June 1988
Lifesaving
Issued 17 April 1987
Resolved
REPAIR WATER LIGHT FOR RING BOUY.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Engineering
Issued 17 April 1987
Resolved
RENEW ACCESS COVER FOR EMERGENCY FUEL SHUTOFF.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Accommodation/Occupational Safety
Issued 17 April 1987
Resolved
RESECURE RAILS WHERE LOOSE.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Engineering
Issued 17 April 1987
Resolved
REPLACE FUEL LINES WITH APPROVED TYPE IAW 46CFR182.20-40
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Lifesaving
Issued 17 April 1987
Resolved
REPAIR OR RENEW RING BOUY.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Lifesaving
Issued 27 May 1986
Resolved
REPLACE 6 ORANGE SOMKE AND 3 RED HAND HELD FLARES.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986