Records from 2016 to 2025. Most recent: inspection, 12 August 2025.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2025
Resolved
A vessel not required to have power driven fire pump must have at least three 2.5 gallon buckets, with an attached lanyard, with the words "FIRE BUCKET" stenciled in a contrasting color on each bucket. Vessel does not have any fire buckets.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 August 2025
Resolved
All observed unsafe hazardous situations must be corrected and in satisfactory condition. There is a loose cord on aft deck coming from a breaker box.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 25 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2025
Resolved
Each semi-portable fire extinguisher must be permanently attached to a bulkhead or deck. Fire extinguishers not properly permanently attached to a bulkhead or deck.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 25 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2025
Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. Flexible fuel hose connections had only one clamp.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 25 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2025
Resolved
Portable and semi-portable extinguishers must be inspected in accordance with NFPA 10. No service records for fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 12 August 2025
Resolution: Owner/Operator produced two new/serviced portable fire extinguishers to replace the unserviced ones.
01 - Certificates & Documentation › 011 - Ships Certificates › Decision-Support System for Masters on Pass. Ships
Issued 12 August 2025
Resolved
A power-drive vessel underway shall exhibit a masthead light forward. Masthead light not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 25 August 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 August 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Vessel only has one light.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 25 August 2025
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 12 August 2025
Resolved
Fire fighting, abandon ship and man overboard drills and training shall be logged. Drills and training not logged since Feb2025.
46 CFR 185.520(f)
46 CFR 185.524(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 12 August 2025
Resolution: USCG MIs got underway with Owner, Operator, and crew to perform fire fighting, abandon ship, and man overboard drills. All satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 August 2025
Resolved
Each flare must be stowed in a portable watertight container marked "DISTRESS SIGNALS." Flares not in a watertight container and not marked properly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 25 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2025
Resolved
The name of the vessel must be marked on each buoyant apparatus, and each ring life buoy must be marked with Type II retroreflective material. Ring buoy has wrong vessel name and retroreflective tape not valid.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 4 September 2025
Resolution: new solas retro installed. Name marked porperly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from fire, explosion, machinery failure, and personnel injury. Starboard outboard engine has a loose hanging hose.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 25 August 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2024
Resolved
46 CFR 183.340(d)(2)
Cable and wire for power and lighting circuits must: Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable;
Numerous wiring runs going to outlets or switches on board the vessel used extension cords or extension cord wires that had been cut and wired into devices or terminals. Remove unauthorized cables and ensure any new installations of wiring comply with 46 CFR 183.340.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Wiring was replaced with approved type.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2024
Resolved
46 CFR 183.200(b)
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;
Multiple relocatable power taps (power strips) were used onboard the vessel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2024
Resolution: All power strips were removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2024
Resolved
46 CFR 183.200(c)
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts;
The power input poles on the inverter were exposed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2024
Resolution: A cover plate was fashioned to protect the power input poles.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2024
Resolved
46 CFR 183.340(i)(2)
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit.
Wire nuts were used to connect wires in the overhead in the forward portion of the cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2024
Resolution: Wire nuts were replaced with heat shrunk butt connectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2024
Resolved
46 CFR 180.71(a)
An adult life jacket must be provided for each person carried on board a vessel.
Five life jackets were unserviceable.
Vessel is limited to 28 total persons on board.
Action required: 705 - Other - as specified
Resolved 26 August 2024
Resolution: Unservicable PFDs were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2024
Resolved
46 CFR 180.70(d)
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required.
Waterlight did not work.
Vessel is limited to daylight operations only until the waterlight is functional.
Action required: 705 - Other - as specified
Resolved 29 July 2024
Resolution: Battery was replaced and op tested. All sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 July 2024
Resolved
46 CFR 181.610:
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets
Only two fire buckets were on board. A third five gallon bucket was provided but needs to be modified to have a capacity of 2.5 gallons or replaced with a sufficient fire bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 29 July 2024
Resolution: New fire bucket was brought onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2024
Resolved
46 CFR 184.710
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
First aid kit did not contain analgesic medication.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 29 July 2024
Resolution: Asprin was added to the first aid kit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2024
Resolved
46 CFR 177.820(d)(4)
Seats used to determine the number of passengers permitted, in accordance with § 176.113(b)(3) of this chapter, must be secured to the deck, bulkhead, or bulwark.
Multiple seats were not secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 26 August 2024
Resolution: Seats were fastened to the deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2024
Resolved
46 CFR 182.720(e)(3)(v)(B)
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose
All flexible fuel hose connections had only one clamp at each end.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 26 August 2024
Resolution: Double hose clamps were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2024
Resolved
46 CFR 183.220(a)
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway.
A battery was unsecured in the port aft compartment. Secure the battery properly or remove.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 29 July 2024
Resolution: Battery was removed from the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2024
Resolved
46 CFR 183.220(a)
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway.
Water heater was not secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 29 July 2024
Resolution: Water heater secured with bungee cord.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2024
Resolved
46 CFR 176.700
Alterations to machinery or equipment that affect the safety of the vessel must not be made without the approval of the OCMI.
The water tank was freestanding and unsecured behind the bar in the aft end of the vessel. Relocate the water tank to the location originally specified by the vessel manufacturer
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2024
Resolved 29 July 2024
Resolution: Water tank was reinstalled under the bar.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 May 2023
Resolved
A power-driven vessel shall exhibit a masthead light. Vessel's masthead light was found inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 12 June 2023
Resolution: Recieved pictures from vessel owner of operable light.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 May 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 12 June 2023
Resolution: Recieved picture from vessel owner of up-to-date charts and pubs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2023
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Aft fire extinguisher approval void due to improper bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 12 June 2023
Resolution: Recieved picture of proper installation from vessel owner.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2023
Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Replace all twist-on type connectors with pressure type connectors.
Action required: 10 - Deficiency Rectified
Due 31 May 2023
Resolved 12 June 2023
Resolution: Recieved picture from vessel representative attesting to repairs.
Construction/Loadline › Hull › Weld
Issued 27 September 2016
Resolved
Fractured weld on stbd aft pontoon allowing water intrusion.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 21 July 2025
Resolution: Vessel has gone through a COI/ D/D and annual inspection in 2023 2024.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 27 September 2016
Resolved
Lower units on outboards need repaired/ replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 21 July 2025
Resolution: Vessel has gone through a COI/ D/D and annual inspection in 2023 2024.
Construction/Loadline › Structures › Deck Plating
Issued 27 September 2016
Resolved
Soft spot found near entrance door.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 21 July 2025
Resolution: Vessel has gone through a COI/ D/D and annual inspection in 2023 2024.