← All vessels
KEREM
KEREM is a 1998 freight ship. The Coast Guard has recorded 20 inspections since 1998, most recently in April 2017, along with 16 deficiencies and 7 operational controls.
Records from 1998 to 2017. Most recent: inspection, 13 April 2017.
- Built
- 1998
- Last inspected
- 13 April 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9126429 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA2651
463801
Flag
MALTA
—
Maury page id
psix-463801
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it37136 - Displacement, Metric Ton
29971 - Dead Weight, Metric Ton
18675 - Convention (Subpart B), Gross Ton
10979 - Convention (Subpart B), Net Ton
29971 - Dead Weight, Metric Ton
18675 - Convention (Subpart B), Gross Ton
10979 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
13 April 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6120455
12 April 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6123289
11 April 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6122358
10 October 2014
PI Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5002430
8 October 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5001600
24 August 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4963653
24 August 2014
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4963774
24 August 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4968216
22 August 2014
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4948801
14 August 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4954761
23 April 2009
Deficiency Check · ISPS I Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3457361
23 April 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3458663
23 April 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3459175
26 September 2005
ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2501404
6 November 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1701952
7 August 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 280713
15 July 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 430625
9 July 1998
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 417669
14 May 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 415809
10 May 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 416001
Deficiency record · 16
Lifesaving › Inflatable Liferafts › Painter
Issued 13 April 2017
Resolved
0628 - Each liferaft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the Code. PSCO observed that the port and starboard side liferafts had the painter line attached directly to a shackle on the mounting assembly and not to a weak link per the manufacturer's instructions. 74SOLAS(01)III/13.4.2 - 17a
Construction/Loadline › Structures › Deck Plating
Issued 10 October 2014
Resolved
0938-Hull damage impairing sea-worthiness- Watertight decks shall be of the same strength as watertight bulkheads. PSCO observed damage to the vessel's port quarter after it collided with MV LAVENDER PASSAGE. The damage
consisted of bent handrails. vents and chock. The watertight envelope between the weather deck and Provision room is
compromised. - SOLAS 74am II-1/16-1
Engineering › Steering Gear System › Power Unit
Issued 24 August 2014
Resolved
The vessel experienced a steering loss while in the Mississippi River.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 August 2014
Resolved
0750 - Fire Prevention - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that in all respects will remain fit to proceed to sea without danger to the ship or persons on board. In the #3 Poop deck pipe and duct room, crew installed transformer with wiring running through class "A" bulkhead. Request class approval
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 April 2009
Resolved
0716- A/0 and B/0 fire doors throughout the vessel are wasted. Doors do no close properly. In machinery space A/C room door, galley doors and tank compartment. This could lead to to excessive spread of fire. All doors shall be repaired/replaced to ensure fireboundaries integrity. To be addressed to the satisfaction of class. A/C room room door and galley doors missing self closing device.
Construction/Loadline › Structures › Door
Issued 23 April 2009
Resolved
1270- Water tight door in Crew smoking leading to the weather deck is not seated nor sealing properly. Also weather tight doors on house leading o the weather deck do not open/close properly. These issues could lead to ingress of water. It can also pose safety issues during emergencies. Gaskets on house doors are cracked/worn. All doors to be addressed and rectified by class.
Construction/Loadline › Structures › Manhole
Issued 23 April 2009
Resolved
Numerous man hole covers on main deck are missing nuts and bolts. This could lead to ingress of water casuing possiblestability issues. To be addressed and recitifed to the satisfaction of class.
Engineering › Compressed Air System (start air) › Compressor
Issued 23 April 2009
Resolved
1499- Number 3 start air compressor is continuously running, due to possible control malfunctions or air leaks. There is also oil pooling below all three compressors. To be addressed and rectified to the satisfaction of class.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 23 April 2009
Resolved
0936- Steering gear hydraulic reservoir is empty. Must be able to refill system for one change over as per SOLAS regs. Class to verify level is adequate.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 23 April 2009
Resolved
1499- Hydraulic power unit cargo haches located in the Focsle has numerous leaks, which has lead to pooling and leaking on the deck. Oil has began to collect in the dewatering sumps. This is a potential pollution and fire hazard. To be rectified to the satisfaction of class, verify proper operation.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 23 April 2009
Resolved
1040- Machinery alarm printer has been inoperable since 20March2009. Needs to be rectified by class for proer operation. ISM 9 & 10
Operations/Management › Pollution › Retention of Oily Mixture
Issued 23 April 2009
Resolved
1721- Oil drums in the Focsle are leaking from the tops onto the deck. Oil is draining into dewatering sumps. This is a potential pollution and fire hazard, and is a house keeping issue. To be addressed and rectified to the satisfaction of class. SOLAS I/11.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 23 April 2009
Resolved
Shaft seals on both port and starboard mooring winch gear box is leaking oil Needs to be inspected and rectified to the satisfaction of class. This poses a potential pollution issue.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 23 April 2009
Resolved
2199- Sewage treatment plant procedures are not being conducted by the ships crew according to the manufacturers requirements. Weekly chlorine test are not being performed. Appropriate test kits are not on board to be addressed by class.
33CFR159.121(b)
Documentation
Issued 10 May 1998
Resolved
Insufficent oil transfer procedures._x001C_ 33 CFR 155.720 1&3
Navigation
Issued 10 May 1998
Resolved
Provide recorder for echo depth sounder._x001C_ 33 CFR 164.35i
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.