Inspections, by type

…with no type recorded9
Years with a record 16 calendar years (1998–2016)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)149.1 ft × 30.0 ft × 12.1 ft
Registered tonnagegross 99 / net 72
ITC dimensions (L × B × D)149.1 ft × 30.0 ft × 12.1 ft
ITC tonnagegross 340 / net 102
BuilderSWIFTSHIPS, INC · MORGAN CITY, LA, UNITED STATES · built 1997
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Regulatory (Subpart C or D), Net Ton
102 - Convention (Subpart B), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
340 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE2969MMSI 367332180 · active · compulsorily equipped · granted 10 November 2017, expires 18 January 2028
WCX8937MMSI not assigned · expired · voluntarily equipped · granted 29 December 1997, cancelled 1 March 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

O MISAN-1 Offshore Supply Vessel · MISLE 52808 · 23 April 2003 · activity 1779904

Inspection history · 31

16 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5834747
11 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4375317
11 June 2012 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4341082
8 February 2011 Hull Examination · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3941758
4 February 2010 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3675404
19 February 2009 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3420361
10 February 2009 Re-Inspection · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3432523
13 February 2008 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3146979
28 February 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2879582
24 February 2007 Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2876905
8 February 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2868944
20 January 2006 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2569834
13 August 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2512666
27 January 2005 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2281886
13 July 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2131545
29 March 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2033045
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1973759
23 April 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1779904
8 April 2003 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1770552
5 March 2003 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1752849
22 January 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1480192
17 January 2002 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1478907
24 January 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458834
28 January 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426321
28 January 1999 Type not recorded
No type recorded · CGC POINT BAKER · USCG Heartland District (CGD-H) · Activity 1509233
25 January 1999 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1378561
12 November 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 770920
10 November 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 665848
28 October 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 22104
28 October 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 197019
23 January 1998 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463355

Deficiency record · 17

Documentation › Certificates/Documents › Stability Letter
Issued 11 July 2012 Resolved
The vessel shall reduce the max deck cargo weight by 1380 P pounds.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 July 2012
Resolution: Stability letter has been updated to reflect new passenger weights.
Fire Fighting › Fire Pumps › Pressure
Issued 10 February 2009 Resolved
Fire pump was putting out insufficient pressure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2009
Resolution: Repairs were made to pump to bring pressure to sufficient pressure.
Documentation › Certificates/Documents › FCC SSL
Issued 10 February 2009 Resolved
Vessel did not have current Bridge to bridge cert.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2009
Resolution: Vessel obtained Bridge to bridge radio cert.
Construction/Loadline › Hull › Stringer
Issued 13 February 2008 Resolved
T bar in overhead above stbd generator had cracked welds in previously repaired welds. Due to proximity to electrical cables, vessel is allowed to gouge and reweld cracked welds as a temporary repair. Permanent repairs shall be done at next drydock in Feb 09.
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 26 March 2009
Resolution: Permanent repairs completed on t-bar.
Construction/Loadline › Structures › Deck Plating
Issued 13 February 2008 Resolved
Stancian holders in aft deck have holes from water sitting in holders. Vessel is allowed to gouge and reweld holes as a temporary repair. Permanent repairs shall be done at next drydock in Feb 2009.
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 26 February 2009
Resolution: Permanent repairs completed.
Navigation › Piloting/Steering
Issued 31 March 2004 Resolved
Provide 2004 Light List. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 5 April 2004
Navigation › Piloting/Steering
Issued 31 March 2004 Resolved
Provide current Local Notice to Mariners. LEGACY COMPONENT DESC: Local Notices to Mariners
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2004
Resolved 5 April 2004
Communications › Radio Communications
Issued 31 March 2004 Resolved
Provide EPIRB registration. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 5 April 2004
Electrical › Lighting (service)
Issued 31 March 2004 Resolved
Provide glass globes for pilothouse console or renew with plastic covers. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 5 April 2004
Operations/Management › Passenger Operations
Issued 31 March 2004 Resolved
Provide Passenger Safety Orientation. LEGACY COMPONENT DESC: Safety Orientation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2004
Resolved 5 April 2004
Operations/Management › Passenger Operations
Issued 31 March 2004 Resolved
Provide documentation for crew and passenger list. LEGACY COMPONENT DESC: Crew and Passenger List
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 5 April 2004
Lifesaving › Lifebuoys
Issued 31 March 2004 Resolved
Renew retro-reflective tape on one life ring and on four life floats. LEGACY COMPONENT DESC: Retro-reflective Tape
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2004
Resolved 5 April 2004
Pollution Prevention/Response › Prevention Equipment
Issued 31 March 2004 Resolved
Provide lock and chain for sewage valve. LEGACY COMPONENT DESC: Sewage System Valve
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 5 April 2004
Electrical › Lighting (service)
Issued 31 March 2004 Resolved
Provide light cover for galley range hood. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 5 April 2004
Documentation › Certificates/Documents
Issued 30 March 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 5 April 2004
Documentation › Certificates/Documents
Issued 29 March 2004 Resolved
Provide FCC Bridge-to-Bridge documentation. LEGACY COMPONENT DESC: FCC Bridge-to-Bridge License
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2004
Resolved 5 April 2004
Engineering › Generator (propulsion/auxiliary-electric)
Issued 11 March 2003 Resolved
Generators are rated for 40 degree C, not the required 50 degree C as stated in 46 CFR 183.320.
Condition: Improper Installation
Due 11 April 2003
Resolved 7 April 2003
Resolution: Vsl rep provided new tags from manufacturer indicating 50 degree C operating rating.

Casualty record · 1

23 April 2003Routine · role: Transiting Vicinity of Primary Subject · activity 1779904
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.