DOUBLE EAGLE II
Passenger (Inspected) · Passenger Ship class · Built 1960s · USCG Southeast District (CGD-SE) · Other hulls named DOUBLE EAGLE II
DOUBLE EAGLE II is a 1969 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in February 2026, along with 177 deficiencies — 2 with no resolution recorded — and 3 casualty investigations between 2005 and 2023.
Records from 1985 to 2026. Most recent: inspection, 9 February 2026.
- Built
- 1969
- Last inspected
- 9 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 177 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2005–2023
Identity
522907
WY7818
46393
Flag
UNITED STATES
367094410
Maury page id
psix-46393
Inspections, by type
…with no type recorded6
Years with a record
39 calendar years (1985–2026)
The 81 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)64.5 ft × 26.2 ft × 7.6 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · CLEARWATER, FL, UNITED STATES · built 1969
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCLEARWATER, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WY7818MMSI 367094410 · active · compulsorily equipped · granted 8 December 2016, expires 12 February 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 81
9 February 2026
Deficiency Check · Annual Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8279604
10 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8045060
17 May 2024
Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7914142
5 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7842826
14 September 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7792033
18 August 2023
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7771414
17 August 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7771368
6 February 2023
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7601838
2 September 2022
In-Service Inspection · Plan Review "T" Boat · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7549577
10 August 2022
Hull Examination · In-Service Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7489505
7 February 2022
COI Inspection · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7364833
16 February 2021
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7114915
30 September 2020
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6961875
3 February 2020
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6870948
5 March 2019
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6630791
18 September 2018
Administrative Inspection · Deadweight Survey · Internal Structural Exam · Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6543531
4 December 2017
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6317653
7 February 2017
DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6028800
8 September 2016
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5995084
1 February 2016
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5807054
19 January 2012
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4227491
11 August 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4113351
24 February 2011
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3949753
8 September 2010
Drydock Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3849129
26 February 2010
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3685440
10 February 2009
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3415168
4 September 2008
Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3316951
8 January 2008
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3125784
18 April 2007
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2909951
12 September 2006
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2775674
27 April 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2634115
28 April 2005
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2342430
24 February 2005
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2298696
22 February 2005
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2386089
16 December 2004
Hull Examination · Construction Oversight
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2273400
29 April 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2049127
24 June 2003
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1805561
5 May 2003
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1784291
21 June 2002
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1626777
29 April 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1608711
19 June 2001
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1391590
26 June 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1051982
4 May 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1421865
9 December 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1384353
23 August 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1115880
30 April 1999
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1402937
2 February 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1125400
4 June 1998
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1381336
2 June 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1438588
11 December 1996
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1406048
30 April 1996
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1085346
19 June 1995
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 877665
4 May 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1207769
6 May 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1170259
19 January 1994
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 851412
13 January 1994
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1161241
11 January 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1161471
15 November 1993
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 831086
2 August 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1152467
30 April 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1149242
26 February 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1150907
1 September 1992
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1248525
1 June 1992
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 947197
15 October 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1253531
24 June 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1217816
6 June 1991
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1308275
6 May 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1228792
11 July 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899550
1 May 1990
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 907298
5 December 1989
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1195723
17 May 1989
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1339791
5 May 1989
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1037539
17 May 1988
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 892341
3 May 1988
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 892336
23 February 1988
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1042847
4 May 1987
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1334490
8 October 1986
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1019969
8 May 1986
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 992258
3 December 1985
Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 991191
24 September 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1300032
7 May 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1287823
Deficiency record · 177
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 February 2026
Resolved
46 CFRE 182.100
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed diesel fuel leaks on port and stbd engine room supply and return fuel piping. Enact permanent repairs to the satisfaction of USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2026
Resolved
46 CFRE 182.100
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed hydraulic leaks on steering ram supply hoses. Enact permanent repairs to the satisfaction of USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 February 2026
No resolution recorded
46 CFR 181.300 (a) (ii)
A self priming, power driven fire pump must be installed
on each vessel Of not more than 19.8 meters (65 feet) in
length that carries more than 49 passengers. Fire pump is not operational. Enact permanent repairs to the
satisfaction of USCG Marine Inspector.
CODE 705: Vessel is restricted to carrying no more than
49 passengers.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 February 2026
Resolved
46 CFR 183.420
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. AMI observed that masthead light was working intermittently. Enact permanent repairs to the satisfaction of USCG Marine Inspector.
CODE 705: Vessel restricted to daytime operations and visibility greater that 2.0 nautical miles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 February 2026
Resolved
46 CFR 182.530 (b)
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. MI observed that visual indicator was working intermittently in in STBD tank space, STBD head space, and port forward space, Enact permanent repairs to satisfaction of USCG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 9 February 2026
Resolved
46 CFR 177.960
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Machinery guard was not installed on STBD engine.
Install guard.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 9 February 2026
Resolved
46 CFR 185.510 (a)
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have emergency instructions.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 February 2026
Resolved
46 CFR 183.200 (b)
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including electrical shock. MI observed battery fuse in STBD engine room missing cover. Install cover.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 February 2026
Resolved
46 CFR 181.520
Portable fire extinguishers location must be to the satisfaction of the Officer in Charge, Marine Inspection. 10 B.C extinguisher bracket in pilothouse was broken. Replace bracket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 February 2026
No resolution recorded
46 CFR 183.200
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Owner told MI that generator is going to be replaced in kind due to a failed head gasket.
CODE 705: Operational test of new generator will need to be witnessed by USCG Marine Inspector before it can be operated with passengers on board vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 February 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Vessels stern light did not work. Restricted operations to daytime and visibility >01nm.
46 CFR 183.420 (705c)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 February 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Inspector observed the battery for the waterlight on the ring buoy was expired by nearly 5 years. Restricted operations to daytime and visibility >01nm.
46 CFR 180.70(c) (705c)
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 February 2025
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Inspector observed batteries for lights for all seven life floats were expired. Restricted operations to daytime and
visibility >01nm.
46 CFR 180.175(d) (705c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 February 2025
Resolved
The intent of this part is to insure that all machinery
in such a manner as to afford adequate protection
against fire, explosion, machinery failure and personal
injury. Inspector observed missing insulation/lagging
from the port side main engine turbo. Repair to
satisfaction of CG inspectors within 03 days.
46CFR182.01-5(c) (705c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 February 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Inspector observed the bilge high level alarm in the port side engine room did not give a visual alarm at operating station.
46CFR182.530(a) (16c)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 February 2025
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers On each life float and buoyant apparatus. Inspector observed 02 life floats lettering was illegible.
46CFR185.604 (16c)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2025
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Inspector observed 03 life jackets needing replacement of retroreflective tape.
46CFR185.604(h) (16c)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in
conspicuous places that are regularly accessible and
visible to crew and passengers. Inspector observed
multiple types of lifejackets but only had placard
for one type of lifejackets.
46CFR185.516 (16c)
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 10 February 2025
Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Inspector observed vessel had installed INMARSAT telephone, but did not have an updated station license and installation certificate for the new equipment.
46CFR184.502
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 February 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Inspector observed vessel had no procedures in place for conducting and recording monthly inspections and test of portable fire extinguishers.
46CFR176.80(b)(1)(ii) (16c)
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 February 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. MI observed that generator didn't shut down when fire extinguishing system was tested. Vessel master identified that the two signal wires were hooked up backwards. Test sat.
46CFR181.420(a)(4) (10c)
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 August 2024
Resolved
Stbd engine room, main engine, raw water cooling, through hull ball valve is not closing all the way. Make repairs or replace valve and ensure it closes all the way.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 February 2024
Resolved
Except as otherwise provided in this section, vessels in ocean service shall carry sufficient life floats for all persons on board.
46 CFR 180.10-5(a)
MI observed deteriorated hand holds on (01) life float. Vessel passenger total is reduced by 12 until deficiency is rectified.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 February 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces.
46 CFR 182.530(a)
MI observed the vessel's port and starboard bilge high water level alarms at the operator's station incorrectly displayed corresponding alarms.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 February 2024
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket.
46 CFR 181.610
MI observed vessel only had one, unlabeled fire bucket for emergency use. Vessel must add two more fire buckets with labeling and drilled 1" holes on each side.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 February 2024
Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date- Light Lists.
46 CFR 185.20-35
MI observed vessel's Light List was dated 2021, not 2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
46 CFR 177.960
MI observed the starboard diesel engine did not have a machinery guard in place.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 6 October 2023
Resolved
A vessel must comply with the applicable requirements for any radio installation IAW 47 CFR part 80.
INMARSAT was found to be inoperable.
Vessel operations has been limited to 20 nautical miles from land until repairs have been made.
46 CFR 184.502
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 September 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces.
Vessel shall install system to the satisfaction of attending USCG Marine Inspector.
46 CFR 181.405(c)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 September 2023
Resolved
Flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions.
Vessel shall develop plan to the satisfaction of attending USCG Marine Inspector.
46 CFR 185.364
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
MI was notified that following a lightning strike, the vessel lost propulsion due to both main engine and generator failure.
46 CFR 182.100
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines.
Vessel's fuel shutoff valve reach rod, for the port fuel tank, broke during operation for inspection. Repair fuel shutoff valve reach rod.
46 CFR 182.455(a)(4)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2023
Resolved
Each ring life buoy with floating water light must have a lanyard of at least 3 feet.
Replace frayed lanyard for ring life buoy.
46 CFR 180.70(d)(2)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 February 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and navigational publications.
Obtain current paper charts and required publications for vessel.
46 CFR 184.420(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2022
Resolved
A dual voltage generator installed on a vessel shall be
of the grounded type, where: The neutral of a dual
voltage system must be solidly connected at the
switchboard's neutral bus and t he neutral bus shall be
connected to ground. The neutral of a dual voltage
system must be accessible for checking the insulation
resistance of the generator to ground before the
generator is connected to the bus. Ground detection must
be provided that: for an alternating current system,
meets § 111.05-27 in subchapter J of this chapter.
The dual voltage generator onboard with a manufacturer
date of 2012 was installed without Coast Guard oversight
and plan review. The neutral to ground is not installed
at the switchboard and is missing ground fault
detection.
Submit electrical plans to the MSC for approval. Per 46 CFR 183.330(j), switchboards and distribution panels must be sized in accordance with Section 7.10 of IEEE 45-1998 or IEC 60092-302 (clause 7) as required by 46 CFR 111.30-19(a).
46 CFR 183.324
46 CFR 183.376
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2022
Resolved
A grounded alternating current system must be grounded
to the hull of a metallic vessel or, on a nonmetallic
vessel the neutral must be connected to a common ground.
The operator removed the common ground from the starboard hull. The neutral for the dual voltage generator is not connected to a common ground. The common ground is missing in the starboard hull.
46 CFR 183.376(d)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2022
Resolved
Per 46 CFR 183.376(a), there must only be a single
neutral connection to ground in a grounded distribution
system, regardless of the number of power sources. When
the power source is onboard the vessel, this ground
connection must be at the switchboard. When connected to
shore power the vessel neutral to ground bond must be
severed because the shore power neutral to ground to
neutral connection is made at the service entrance panel
on shore. If this neutral to ground bond is not broken,
the neutral to ground bond onboard the vessel will
create a parallel circuit and neutral current will flow
on both the shore power neutral and the shore power
safety ground. This presents an electric shock hazard,
posing a threat to passengers and crew, and also may
create stray currents that endanger any swimmers or
divers in close proximity to the SPV.
The current shore power connection to the vessel was found with a dead end grounding conductor presenting a hazard to the vessel and personnel. The electrical installation onboard does not provide the ability for the permitted shore power
connection to be installed in a manner to comply with 46 CFR 183.376(a).
Submit electrical plans to MSC that illustrate the proper shore power installation in order to prevent an improper neutral to ground bond onboard the vessel. Contact USCG MI for verification of installation once plans are approved.
46 CFR 183.376(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2022
Resolved
Metallic enclosures and frames of electrical equipment
must be permanently bonded to the common ground on a non
metallic vessel.
The common ground was removed in the starboard hull and all electrical metallic enclosures were found without a bond to the common ground.
Size grounding conductors IAW 46 CFR 183.372(c).
46 CFR 183.372(a)
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 February 2022
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew.
Port forward railing found fractured at the port bow.
46 CFR 177.35-1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2022
Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant.
Overcurrent protection for the conductor between the DC panel and the inverters is missing.
46 CFR 183.380
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2022
Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant.
Overcurrent protection for the conductor between the battery switch and DC panel in the port and stbd engine room is missing.
46 CFR 183.380
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2022
Resolved
A dual voltage generator installed on a vessel shall be of the grounded type, where: The neutral of a dual voltage system must be solidly connected at the switchboard's neutral bus and the neutral bus shall be connected to ground. The neutral of a dual voltage system must be accessible for checking the insulation resistance of the generator to ground before the generator is connected to the bus. Ground detection must be provided that: for an alternating current system, meets § 111.05-27 in subchapter J of this chapter.
The dual voltage generator onboard with a manufacturer date of 2006 was installed without ground fault detection and the neutral is not connected to ground at the first disconnect.
46 CFR 183.324
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Identified three floor frames with wood decay in stbd compartment 2.
46 CFR 176.20-1
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Transverse frame over starboard shaft in compartment 3 found with wood decay.
46 CFR 176.20-1
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Identified wood decay on the inboard bulkhead upper frame at attachment to forward bulkhead in stbd steering space.
46 CFR 176.20-1
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Transverse floor frame found with wood decay under starboard rudder post.
46 CFR 176.20-1
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Wood decay found on the FWD water tight bulkhead bottom frame in the port steering space.
46 CFR 176.20-1
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Floor frame found with wood decay under port rudder post.
46 CFR 176.20-1
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 February 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Wood decay found on water tight bulkhead inboard vertical frame in stbd forward compartment number 1.
46 CFR 176.20-1
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Wood decay found in overhead transverse beam in port forward compartment 1.
46 CFR 176.20-1
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Four longitudinal inboard side shell frames found fractured in the port side compartment 2 and one transverse floor frame found holed with wood decay.
46 CFR 176.20-1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 February 2021
Resolved
All machinery shall be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury.
Inspectors identified diesel leak on the fuel return line after racor fuel filter housing for the port main diesel engine. Vessel operator repaired the pipe prior to getting underway removing pipe and resealing. Operational test SAT.
46 CFR 182.01-5 "Old T"
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 February 2021
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. The float-free link required by 180.130(a)(1) must be of proper strength for the size of the life float as indicated on its identification tag. Inspectors were unable to determine the breaking strength of 04 float-free links due to missing identification tags. The links were also stretched and twisted. The vessel operator replaced all links except the one on the 8 person life float. Passenger count is reduced to 67 until float-free link is replaced. 46 CFR 180.137 (b)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 February 2021
Resolved
A life float must be approved under series 160.027.
The color of the buoyant apparatus must be primarily vivid reddish orange. The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float. The 8 person life float was severely faded and the person capacity was not visible. Passenger count is reduced to 67 until life float is repaired.
46 CFR 180.200(a)(2)
46 CFR 160.010-4(n)
46 CFR 185.604(e)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2021
Resolved
A number of child size life jackets equal to at least 10% of the number persons permitted on board must be provided.
01 child life jacket was unserviceable. Child passenger count reduced to 07 until life jacket is replaced.
46 CFR 180.71(b)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 February 2021
Resolved
Each flare must be stowed in a portable container marked as required by 185.614 of this chapter. Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: ‘‘DISTRESS SIGNALS’’.
The portable container was severely corroded and the bottom was rusted out.
46 CFR 180.68 (e)(1)
46 CFR 185.614
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 February 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Coast Guard Light List. The Light List onboard was from 2019. Replace with up-to-date version.
46 CFR 184.420 (a)(3)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 February 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The items contained in first-aid kit shall be as listed in Table 160.041-4(b). Aspirin supplied in the first-aid kit was expired. Operator provide new non-expired aspirin.
46 CFR 184.710
46 CFR 160.041-4(b)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 February 2020
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's hydrostatic release expired on January, 2019. Vessel owner replaced on the spot. - 46CFR180.64
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 February 2020
Resolved
Each life float must be secured to the vessel by a painter with a float-free link permanently attached to the vessel; certified to meet § 160.073 in subchapter Q of this chapter or of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Float-free link on starboard bottom life float was wasted and float-free link on port top life float was larger gauge and incorrectly sized for 12pax life float. Vessel owner replaced on the spot. - 46CFR180.137(b)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 February 2020
Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. Aft-most port side bridge safety glass is cracked. - 46CFR177.1030(a)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 March 2019
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light.
MI observed 02 life float water lights extinguished. Replace.
46 CFR 180.175 (d)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 March 2019
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced.
MI observed tear/hole on inside grab line of life float. Repair. 46 CFR 176.808 (b)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 March 2019
Resolved
The number of persons capacity and name of a vessel must be marked or painted in clearly legible letters and numbers on each life float.
Ensure all (07) life floats are marked as required. 46 CFR 185.604
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 March 2019
Resolved
A vessel must comply with the applicable requirements for any radio installation as set forth in 47 CFR part 80.
Vessel's VHF radio was missing GPS input. Repair. 46 CFR 184.502
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2019
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice.
MI observed electrical wiring passing through holes centerline bulkhead in engine room compartment. Seal penetrations. 46 CFR 176.800 (a)
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 February 2018
Resolved
Replace battery and prove operation of life float water light. 46CFR180.70
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 February 2018
Resolved
Replace missing guard on exposed hazard port side MDE. 46CFR177.960
Engineering › Bilge Water Management System › Strainer
Issued 5 February 2018
Resolved
Replace missing bilge suction strainers in fuel compartments port and starboard sides. 46CFR182.510(b)
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 February 2018
Resolved
Replace expired items in first aid kit, meeting CG approval series 160.041. 46CFR184.710
Engineering › Fuel Oil Service System › Piping
Issued 7 February 2017
Resolved
Replace strbd engine fuel line from secondary filter to engine. 46CFR182.455
Engineering › Fuel Oil Service System › Valve
Issued 7 February 2017
Resolved
Properly label fuel shut off valve. 46CFR182.455
Stability › Watertight Integrity › General
Issued 7 February 2017
Resolved
Port/strbd hatches require permanent connections. 46CFR179.360
Construction/Loadline › Hull › Hull Plating
Issued 8 September 2016
Resolved
Provide repair proposal for port strut assembly where wasted. Remove backing plate and make available for inspection IAW 46 CFR 176.25-5
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 February 2016
Resolved
Vessel is restricted to 53 adults and 6 children until proper lifejackets are acquired IAW 46 CFR 180.71.
Stability › Weathertight Integrity › General
Issued 1 February 2016
Resolved
Make portside access to engine room weathertight IAW 46 CFR 179.360.
Lifesaving › Lifefloat › Netting
Issued 9 February 2012
Resolved
Vessel is restricted to carrying no more than 73 total persons onboard. 6-man lifefloat is unserviceable due to missing net. 46 CFR 185.700
Fire Fighting › Fire Pumps › Pressure
Issued 9 February 2012
Resolved
Install pressure gauge on discharge side of fire pump. Prove proper operating pressure of 60 psi. 46 CFR 181.10-1(c)
Electrical › Electric Supply System (service) › Cable
Issued 9 February 2012
Resolved
Install laock washers or lock nuts on battery terminals and connections. 46 CFR 183.350
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 February 2010
Resolved
Replace all expired items in first aid kit
Communications › Radio Communications › VHF Radiotelephone
Issued 24 February 2010
Resolved
Provide proof of current FCC radio safety certificate
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 24 February 2010
Resolved
Replace remote pull cable on port engine room fixed firefighting bottle
Lifesaving › Lifefloat › Serviceable
Issued 24 February 2010
Resolved
Repair or replace 12 pax lifefloat
Engineering › Reduction Gearing/Clutches › Casing
Issued 24 February 2010
Resolved
Replace sea suction hose on port reduction gear
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 24 February 2010
Resolved
Replace missing hardware on bulkhead penetration plate for stbd propulsion shaft
Lifesaving › Lifebuoys › Serviceable
Issued 10 February 2009
Resolved
REPLACE WASTER LIFELINES AND FLOATING LIGHT LINES ON ALL LIFEFLOATS.
Engineering › Bilge Water Management System › Pump
Issued 10 February 2009
Resolved
REPAIR/REPLACE PORT BILGE PUUMP.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 February 2009
Resolved
REPAIR PORT RUNNING LIGHT PRIOR TO OPERATING AT NIGHT.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 February 2009
Resolved
REPLACE WASTED HARDWARE ON STBD AFT EXHAUST PIPE PENETRATIONS IN THE TK ROOM.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 10 February 2009
Resolved
REPAIR WASTED BULKHEAD PENETRATIONS FOR BILGE PIPING IN STBD STEERING COMPARTMENT, PORT ENG ROOM FWD AND STBD ENG ROOM AFT.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 February 2009
Resolved
REPLACE ROTTED SIDE LONGS AS DISCUSSED IN PORT ENG ROOM.
Engineering › Steering Gear System › Bracket/Clamp
Issued 10 February 2009
Resolved
REPLACE WASTED HARDWARE ON STEERING SUPPORT IN THE STBD STEERING COMPARTMENT.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 January 2008
Resolved
Vessel is restricted to voyages less than 20 nautical miles until the single side band (MF) radio is operable and conducts a satisfactory radio check with local Coast Guard.
Lifesaving › Lifefloat › Serviceable
Issued 12 September 2006
Resolved
Replace the 12 person life float that has a hole in it's side as discussed. Total person capacity will be reduced to 68 until 12 person life float is replaced.
Stability › Watertight Integrity › General
Issued 12 September 2006
Resolved
Repair pit in STBD FWD deck hatch combing, or replace hatch as discussed.
Documentation › Certificates/Documents › FCC SSL
Issued 28 April 2005
Resolved
Provide a FCC Marine Radio Operator Permit for master [name withheld]
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 28 April 2005
Resolved
Replace both PORT and STBD fuel oil cross over lines, in muffler room as discussed. Fittings are rusting a way.
Lifesaving › Lifefloat › Lifeline
Issued 28 April 2005
Resolved
Replace all wasted tag lines on all life floats as discussed. Lines are all dry rotted from the sun.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 28 April 2005
Resolved
Repair emergency fuel oil shut-off valve reach rods. Rods do not turn the valve.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 29 April 2004
Resolved
REPLACE OUTLET COVERS AS NEEDED.
Electrical › Electrical Distribution System (emergency)
Issued 29 April 2004
Resolved
REPLACE TWO 32V EMERGENCY LIGHTS. LEGACY COMPONENT DESC: bulbs
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 29 April 2004
Resolved
REPLACE RETROFECTIVE MATERIAL AS NEEDED PRIOR TO CARRIAGE OF PASSENGERS.
Fire Fighting › Fire Hoses › Condition
Issued 29 April 2004
Resolved
REPAIR FIRE HOSE PRIOR TO CARRIAGE OF PASSENGERS.
Construction/Loadline › Hull
Issued 3 June 2003
Resolved
MAKE THE FOLLOWING WOOD HULL & FRAMING REPAIRS: RENEW 11' X 8" X 3/4"SECTION OF PLYWOOD HULL PORT SIDE, CHINE, AFT FORWARD OF TRANSOM. 2"X2"X6' FRAME IN PORT E/R SISTERED. LEGACY COMPONENT DESC: Hull Plating
Lifesaving › Buoyant Apparatus
Issued 5 May 2003
Resolved
Replace floating waterlight on AFT 12 man raft. LEGACY COMPONENT DESC: Water light
Lifesaving › Buoyant Apparatus
Issued 5 May 2003
Resolved
Replace 01 paddle in FWD 25 man raft. LEGACY COMPONENT DESC: Paddle
Lifesaving › Buoyant Apparatus
Issued 5 May 2003
Resolved
Install weak link on FWD 6 man raft. LEGACY COMPONENT DESC: Weak link
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 5 May 2003
Resolved
Conduct annual inspection for all portable fire extinguishers and FFFE systems. LEGACY COMPONENT DESC: Due for inspection
Communications › Radio Communications
Issued 5 May 2003
Resolved
Replace hydrostatic release on 406 MHZ EPIRB. LEGACY COMPONENT DESC: EPIRB
Communications › Radio Communications
Issued 5 May 2003
Resolved
Update EPIRB registration. LEGACY COMPONENT DESC: EPIRB
Lifesaving › Buoyant Apparatus
Issued 5 May 2003
Resolved
Repair netting in 6 man float used for man OVBD drills. LEGACY COMPONENT DESC: Rescue platform
Engineering › Fuel Oil Service System
Issued 5 May 2003
Resolved
Repair PORT & STBD emergency fuel oil shut off valve, reach rods. LEGACY COMPONENT DESC: Valve, Control
Engineering › Bilge Water Management System
Issued 5 May 2003
Resolved
Repair high bilge level alarms system for the STBD, FWD and AFT tank rooms. LEGACY COMPONENT DESC: Alarms
Engineering › Bilge Water Management System
Issued 5 May 2003
Resolved
Repair STBD bilge pump and demonstrate proper operation. LEGACY COMPONENT DESC: Pump
Construction/Loadline › Hull
Issued 5 May 2003
Resolved
Prior to your Credit for a Dry Dock, repair leaks in way of the PORT and STBD, chime, inboard, in the AFT voids. Area is just above the screws. LEGACY COMPONENT DESC: Chime
Engineering › Bilge Water Management System
Issued 5 May 2003
Resolved
Label both PORT and STBD bilge manifolds. LEGACY COMPONENT DESC: Manifold
Engineering › Fuel Oil Service System
Issued 5 May 2003
Resolved
Repair leaks in PORT racor and secondary fuel filters. LEGACY COMPONENT DESC: Filter
Documentation › Manuals/Policy Documentation
Issued 5 May 2003
Resolved
Provide 2003 contract from ASAP for your DAPI program. LEGACY COMPONENT DESC: DAPI
Navigation › Piloting/Steering
Issued 29 April 2002
Resolved
UPDATE COAST PILOT, LIGHT LIST, TIDES AND CURRENTS.
Construction/Loadline › Structures
Issued 29 April 2002
Resolved
REPAIR FORWARD BRIDGE WINDOW. LEGACY COMPONENT DESC: Superstructure
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 April 2002
Resolved
REPAIR AFT STBD HIGH LEVEL BILGE ALARM.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 April 2002
Resolved
INSTALL COROSION RESISTANT LINK WITH 3' TO 6' LANYARD ON FLOATING WATERLIGHT.
Lifesaving
Issued 4 May 2000
Resolved
REPLACE WATERLIGHT BATTERIES.
Electrical
Issued 4 May 2000
Resolved
INSTALL EITHER: PRESSURE TYPE CONNECTORS; SOLDERED LUG; OR, A SPLICE MADE WITH A PRESSURE TYPE CONNECTOR IN WIRING CIRCUITS AS NEEDED.
Fire Fighting
Issued 4 May 2000
Resolved
ATTACH 50FT HOSE TO HYDRANT.
Lifesaving
Issued 4 May 2000
Resolved
REPLACE NETTING ON 12 PERSON LIFEFLOAT.
Lifesaving
Issued 30 April 1999
Resolved
REPLACE RETRO REFLECTIVE MATERIAL ON LIFEFLOATS AS NECESSARY.
Lifesaving
Issued 30 April 1999
Resolved
CONDUCT UNDERWAY MOB AND FIRE DRILLS.
Electrical
Issued 4 June 1998
Resolved
REMOVE DEAD-END WIRING THROUGH-OUT VSL. SUPPORT WIRING RUNS EVERY 24" WITHADEQUATE METALLIC SUPPORTS. ENSURE ALL WIRING IS MECHANICALLY PROTECTED. INSTALL PROTECTIVE COVER OVER BATTERY TERMINALS STBD ENG RM. REPLACE GROUNDING STRAPS ON P+S F/O FILLS, REMOVE RUST FROM FILLS.
Construction/Loadline
Issued 4 June 1998
Resolved
REPLACE DRAIN LINES FOR E/R HATCH SCUPPERS. REPLACE BILGE LINE FLEX HOSE IN FWD BULKHEAD STARBOARD (FWD F/O TANK SPACE).
Construction/Loadline
Issued 4 June 1998
Resolved
REPAIR DAMAGED WOOD FWD BLKHD STARBOARD (FWD F/O TANK SPACE).
Lifesaving
Issued 30 April 1996
Resolved
PROVIDE TWO ADDITIONAL ADULT PFD'S.
Documentation
Issued 30 April 1996
Resolved
POST STABILITY LETTER.
Lifesaving
Issued 30 April 1996
Resolved
PAINT FLARE BOX ORANGE AND STENCIL, DISTRESS SIGNALS.
Construction/Loadline
Issued 30 April 1996
Resolved
REPLACE TWO BROKEN WINDOWS IN PILOT HOUSE AT DRYDOCK.
Engineering
Issued 19 June 1995
Resolved
Replace pvc pipe on engine cool with approved material.
Engineering
Issued 19 June 1995
Resolved
Weld up 1/4" hole in port forward engine exhaust.
Construction/Loadline
Issued 19 June 1995
Resolved
Renew 4 plywood doubler plate for shaft strusts.
Construction/Loadline
Issued 19 June 1995
Resolved
Install thru hull fitting on all hoses passing thru hull bottom or plug.
Engineering
Issued 19 June 1995
Resolved
Double hose clamp fuel thank ventes.
Construction/Loadline
Issued 19 June 1995
Resolved
Replace hose port engine room bilge suction.
Construction/Loadline
Issued 19 June 1995
Resolved
Crop out delaminated plywood bottom, between hulls approximately 15' aft ofbow. Renew approximately 18" x 24" or greater to good wood.
Construction/Loadline
Issued 19 June 1995
Resolved
Renew carriage bolts in transverse angles.
Construction/Loadline
Issued 4 May 1995
Resolved
Replace aft window pane and starbord window pane in pilot house.
Lifesaving
Issued 30 April 1993
Resolved
Renew paint on two, 12 person life floats.
Construction/Loadline
Issued 30 April 1993
Resolved
Label all bilge suction valves.
Electrical
Issued 30 April 1993
Resolved
Install cover on light fixture in the forward part of the starboard engine room.
Engineering
Issued 30 April 1993
Resolved
Adjust packing on both shafts.
Engineering
Issued 30 April 1993
Resolved
Provide double hose clamps on all raw water hose connections supplying bothpropulsion engines.
Engineering
Issued 1 September 1992
Resolved
Descale rust from both fuel tanks.
Construction/Loadline
Issued 1 September 1992
Resolved
Renew rotted section of starboard engine room hatch.
Construction/Loadline
Issued 1 September 1992
Resolved
Remove angel hair at after bulkhead 2nd compartment forward of lazzerette.
Lifesaving
Issued 1 June 1992
Resolved
Renew reflective tape on all lifefloats.
Lifesaving
Issued 1 June 1992
Resolved
restencil person capacity, vessel name on all lifefloats.
Lifesaving
Issued 1 June 1992
Resolved
Label locations for adult and child PFD's.
Lifesaving
Issued 1 June 1992
Resolved
Renew grab lines on 2 lifefloats.
Accommodation/Occupational Safety
Issued 6 May 1991
Resolved
REPLACE SHUT OFF VALVE ON KEROSENE TANK PRIOR TO CARRYING PASSENGERS.
Accommodation/Occupational Safety
Issued 6 May 1991
Resolved
REPLACE KEROSENE HOSE.
Construction/Loadline
Issued 6 May 1991
Resolved
REPLACE VERT. STIFFENER - PORT TRANSOM ON CENTERLINE. TO BE COMPLETED AT NEXT DRYDOCK.
Deck/Cargo
Issued 6 May 1991
Resolved
REPAIR BILGE LINES - PORT AFT (LAZZ.) AND STBD FWD E/R PRIOR TO CARRYING PASSENGERS.
Engineering
Issued 6 May 1991
Resolved
REPLACE VENT HOSES P&S FUEL TANKS.
Engineering
Issued 6 May 1991
Resolved
REPLACE UPPER CROSS CONNECTING HOSES AND DOUBLE CLAMP - P & S FUEL TANKS.
Lifesaving
Issued 6 May 1991
Resolved
RENEW NETTING, LIFELINE AND CLIPS ON 6 MAN RAFT PRIOR TO CARRYING PASSENGERS.
Lifesaving
Issued 6 May 1991
Resolved
RENEW LIFELINES AND PENDANTS ON 2 - 25 MAN RAFTS PRIOR TO CARRING PASSENGERS.
Lifesaving
Issued 6 May 1991
Resolved
RENEW NETTING ON 12 MAN RAFT PRIOR TO CARRYING PASSENGERS.
Electrical
Issued 6 May 1991
Resolved
REMOVE SOLID CONDUCTOR WIRING (NOTED IN SHORE TIE FROM RECEPTACLE THRU VESSEL).
Electrical
Issued 6 May 1991
Resolved
REMOVE BATTERIES AND BOTTOM OF BATTERY BOX FOR INSPECTRION. TO BE COMPLETED AT NEXT DRYDOCK.
Accommodation/Occupational Safety
Issued 6 May 1991
Resolved
PROVIDE MEN'S SINK. TO BE COMPLETED AT NEXT DRYDOCK.
Fire Fighting
Issued 6 May 1991
Resolved
MOUNT B-I EXTINGUISHER IN PILOTHOUSE.
Fire Fighting
Issued 6 May 1991
Resolved
PROVIDE MARINE BRACKETS FOR ALL B-II EXTINGUISHERS.
Fire Fighting
Issued 6 May 1991
Resolved
RELOCATE B-II'S: 1 - GALLEY, 2 EACH P & S E/R'S PRIOR TO CARRYING PASSENGERS.
Engineering
Issued 1 May 1990
Resolved
PROVIDE 30 X 30 MESH SCREENS FOR ALL FUEL TANK VENTS.
Lifesaving
Issued 1 May 1990
Resolved
PROVIDE 18 FEET LINE TO WATERLIGHTS ON THE TWO 12 MAN LIFEFLOATS.
Documentation
Issued 1 May 1990
Resolved
PROVIDE POLLUTION PLACARDS FOR THE PORT AND STARBORD MACHINERY SPACES.
Lifesaving
Issued 1 May 1990
Resolved
PROVIDW 2 PADDLES (4 FOOT) TO ALL LIFEFLOATES ( 10 PADDLES TOTAL).
Documentation
Issued 5 December 1989
Resolved
CREDIT DRYDOCK DUE 30JUN91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Navigation
Issued 5 May 1989
Resolved
PROVIDE A CLASS "A" EPIRB. UNTIL THE EPIRB IS ON BOARD, THIS VESSEL'S ROUTE IS LIMITED TO NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE.
Casualty record · 3
22 February 2005Routine · role: Involved in a Marine Casualty · activity 2386089
11 August 2011Routine · role: Involved in a Marine Casualty · activity 4113351
17 August 2023Routine · role: Involved in a Marine Casualty · activity 7771368
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.