MAURY USCG vessel records
← All vessels

DOUBLE EAGLE II

DOUBLE EAGLE II is a 1969 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in February 2026, along with 76 deficiencies — 2 with no resolution recorded — and 3 casualty investigations between 2005 and 2023.

Records from 2005 to 2026. Most recent: inspection, 9 February 2026.

Built
1969
Last inspected
9 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WY7818
Flag
UNITED STATES
Maury page id
psix-46393

Documentation record

Registered dimensions (L × B × D)64.5 ft × 26.2 ft × 7.6 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCLEARWATER, FL, UNITED STATES · built 1969
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCLEARWATER, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

9 February 2026 Deficiency Check · Annual Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8279604
10 February 2025 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8045060
17 May 2024 Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7914142
5 February 2024 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7842826
14 September 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7792033
18 August 2023 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7771414
17 August 2023 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7771368
6 February 2023 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7601838
2 September 2022 In-Service Inspection · Plan Review "T" Boat · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7549577
10 August 2022 Hull Examination · In-Service Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7489505
7 February 2022 COI Inspection · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7364833
16 February 2021 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7114915
30 September 2020 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6961875
3 February 2020 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6870948
5 March 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6630791
18 September 2018 Administrative Inspection · Deadweight Survey · Internal Structural Exam · Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6543531
4 December 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6317653
7 February 2017 DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6028800
8 September 2016 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5995084
1 February 2016 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5807054

Deficiency record · 76

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 February 2026 Resolved
46 CFRE 182.100 All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed diesel fuel leaks on port and stbd engine room supply and return fuel piping. Enact permanent repairs to the satisfaction of USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2026
Resolution: Leaks were repaired and operationally tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2026 Resolved
46 CFRE 182.100 All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed hydraulic leaks on steering ram supply hoses. Enact permanent repairs to the satisfaction of USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2026
Resolution: Steering hoses were replaced and operationally tested.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 February 2026 No resolution recorded
46 CFR 181.300 (a) (ii) A self priming, power driven fire pump must be installed on each vessel Of not more than 19.8 meters (65 feet) in length that carries more than 49 passengers. Fire pump is not operational. Enact permanent repairs to the satisfaction of USCG Marine Inspector. CODE 705: Vessel is restricted to carrying no more than 49 passengers.
Action required: 705 - Other - as specified
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 February 2026 Resolved
46 CFR 183.420 All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. AMI observed that masthead light was working intermittently. Enact permanent repairs to the satisfaction of USCG Marine Inspector. CODE 705: Vessel restricted to daytime operations and visibility greater that 2.0 nautical miles.
Action required: 705 - Other - as specified
Resolved 24 February 2026
Resolution: Received picture of repaird masthead light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 February 2026 Resolved
46 CFR 182.530 (b) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. MI observed that visual indicator was working intermittently in in STBD tank space, STBD head space, and port forward space, Enact permanent repairs to satisfaction of USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 24 February 2026
Resolution: Received video of operational alarms.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 9 February 2026 Resolved
46 CFR 177.960 An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Machinery guard was not installed on STBD engine. Install guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 24 February 2026
Resolution: Received picture of guard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 9 February 2026 Resolved
46 CFR 185.510 (a) The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have emergency instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 9 March 2026
Resolution: Received pictures from Sightseer technicians after they configured fuse blocks to match approved drawing.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 February 2026 Resolved
46 CFR 183.200 (b) Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including electrical shock. MI observed battery fuse in STBD engine room missing cover. Install cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 24 February 2026
Resolution: Received piture of fuse cover.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 February 2026 Resolved
46 CFR 181.520 Portable fire extinguishers location must be to the satisfaction of the Officer in Charge, Marine Inspection. 10 B.C extinguisher bracket in pilothouse was broken. Replace bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 17 March 2026
Resolution: Received picture of new bracket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 February 2026 No resolution recorded
46 CFR 183.200 Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Owner told MI that generator is going to be replaced in kind due to a failed head gasket. CODE 705: Operational test of new generator will need to be witnessed by USCG Marine Inspector before it can be operated with passengers on board vessel.
Action required: 705 - Other - as specified
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 February 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Vessels stern light did not work. Restricted operations to daytime and visibility >01nm. 46 CFR 183.420 (705c)
Action required: 705 - Other - as specified
Due 10 February 2025
Resolved 12 February 2025
Resolution: Received picture of operational stern light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 February 2025 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Inspector observed the battery for the waterlight on the ring buoy was expired by nearly 5 years. Restricted operations to daytime and visibility >01nm. 46 CFR 180.70(c) (705c)
Action required: 705 - Other - as specified
Due 10 February 2025
Resolved 12 February 2025
Resolution: Battery was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 February 2025 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Inspector observed batteries for lights for all seven life floats were expired. Restricted operations to daytime and visibility >01nm. 46 CFR 180.175(d) (705c)
Action required: 705 - Other - as specified
Due 10 February 2025
Resolved 12 February 2025
Resolution: Batteries were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 February 2025 Resolved
The intent of this part is to insure that all machinery in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury. Inspector observed missing insulation/lagging from the port side main engine turbo. Repair to satisfaction of CG inspectors within 03 days. 46CFR182.01-5(c) (705c)
Action required: 705 - Other - as specified
Due 10 February 2025
Resolved 12 February 2025
Resolution: Lagging was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 February 2025 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Inspector observed the bilge high level alarm in the port side engine room did not give a visual alarm at operating station. 46CFR182.530(a) (16c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Received picture of operational visual indicator.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 February 2025 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers On each life float and buoyant apparatus. Inspector observed 02 life floats lettering was illegible. 46CFR185.604 (16c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Life floats were stenciled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2025 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Inspector observed 03 life jackets needing replacement of retroreflective tape. 46CFR185.604(h) (16c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Received picture of new retroreflective material on life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2025 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to crew and passengers. Inspector observed multiple types of lifejackets but only had placard for one type of lifejackets. 46CFR185.516 (16c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Donning placard was posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 10 February 2025 Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Inspector observed vessel had installed INMARSAT telephone, but did not have an updated station license and installation certificate for the new equipment. 46CFR184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 20 February 2025
Resolution: Received photo of new FCC Radiotelephony Certificate
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 February 2025 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Inspector observed vessel had no procedures in place for conducting and recording monthly inspections and test of portable fire extinguishers. 46CFR176.80(b)(1)(ii) (16c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 20 February 2025
Resolution: Received photo of new checklist with procedures to check fire ext. equipment.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 February 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. MI observed that generator didn't shut down when fire extinguishing system was tested. Vessel master identified that the two signal wires were hooked up backwards. Test sat. 46CFR181.420(a)(4) (10c)
Action required: 10 - Deficiency Rectified
Due 10 February 2025
Resolved 10 February 2025
Resolution: Vessel master fixed wiring, inspector witnessed test of generator/main engines shut down.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 August 2024 Resolved
Stbd engine room, main engine, raw water cooling, through hull ball valve is not closing all the way. Make repairs or replace valve and ensure it closes all the way.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 August 2024
Resolved 12 September 2024
Resolution: The valve was repostioned so it would fully open. Operational test was SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 February 2024 Resolved
Except as otherwise provided in this section, vessels in ocean service shall carry sufficient life floats for all persons on board. 46 CFR 180.10-5(a) MI observed deteriorated hand holds on (01) life float. Vessel passenger total is reduced by 12 until deficiency is rectified.
Action required: 705 - Other - as specified
Due 5 February 2024
Resolved 24 April 2024
Resolution: Vessel rep provided photos of new hand holds on 12-person life float. Vessel passenger count is no longer reduced by 12.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 February 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. 46 CFR 182.530(a) MI observed the vessel's port and starboard bilge high water level alarms at the operator's station incorrectly displayed corresponding alarms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 1 May 2024
Resolution: Vessel rep provided video of operable bilge high water level alarms at the operator's station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 February 2024 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. 46 CFR 181.610 MI observed vessel only had one, unlabeled fire bucket for emergency use. Vessel must add two more fire buckets with labeling and drilled 1" holes on each side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 24 April 2024
Resolution: Vessel rep provided photo of 03 fire buckets with labeling and drilled holes.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 February 2024 Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date- Light Lists. 46 CFR 185.20-35 MI observed vessel's Light List was dated 2021, not 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 24 April 2024
Resolution: Vessel rep stated he downloaded and printed the most up-to-date version of the Light List.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2024 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. 46 CFR 177.960 MI observed the starboard diesel engine did not have a machinery guard in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 24 April 2024
Resolution: Vessel rep provided photo of installed machinery guard on starboard engine.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 6 October 2023 Resolved
A vessel must comply with the applicable requirements for any radio installation IAW 47 CFR part 80. INMARSAT was found to be inoperable. Vessel operations has been limited to 20 nautical miles from land until repairs have been made. 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2023
Resolved 5 February 2024
Resolution: SSB radio and INMARSAT were tested during the annual inspection noted in activity 7842826.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 September 2023 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel shall install system to the satisfaction of attending USCG Marine Inspector. 46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 5 February 2024
Resolution: Vessel rep and installed interconnected system in spaces routinely used by crew and passengers onboard. Tested detector in passenger accommodation space.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 September 2023 Resolved
Flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Vessel shall develop plan to the satisfaction of attending USCG Marine Inspector. 46 CFR 185.364
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 5 February 2024
Resolution: Vessel rep and crew have posted flyers throughout vessel regarding rechargeable lithium-ion batteries and included information in passenger safety brief.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI was notified that following a lightning strike, the vessel lost propulsion due to both main engine and generator failure. 46 CFR 182.100
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2023
Resolved 6 October 2023
Resolution: Operational test of all equipment, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. Vessel's fuel shutoff valve reach rod, for the port fuel tank, broke during operation for inspection. Repair fuel shutoff valve reach rod. 46 CFR 182.455(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2023
Resolved 7 February 2023
Resolution: Received photo evidence of the repaired reach rod.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2023 Resolved
Each ring life buoy with floating water light must have a lanyard of at least 3 feet. Replace frayed lanyard for ring life buoy. 46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 30 March 2023
Resolution: Received photo of repaired ring buoy light lanyard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 February 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and navigational publications. Obtain current paper charts and required publications for vessel. 46 CFR 184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 30 March 2023
Resolution: Received photo evidence of new chart and copies of current navigation pubs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2022 Resolved
A dual voltage generator installed on a vessel shall be of the grounded type, where: The neutral of a dual voltage system must be solidly connected at the switchboard's neutral bus and t he neutral bus shall be connected to ground. The neutral of a dual voltage system must be accessible for checking the insulation resistance of the generator to ground before the generator is connected to the bus. Ground detection must be provided that: for an alternating current system, meets § 111.05-27 in subchapter J of this chapter. The dual voltage generator onboard with a manufacturer date of 2012 was installed without Coast Guard oversight and plan review. The neutral to ground is not installed at the switchboard and is missing ground fault detection. Submit electrical plans to the MSC for approval. Per 46 CFR 183.330(j), switchboards and distribution panels must be sized in accordance with Section 7.10 of IEEE 45-1998 or IEC 60092-302 (clause 7) as required by 46 CFR 111.30-19(a). 46 CFR 183.324 46 CFR 183.376
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2022
Resolved 17 November 2022
Resolution: The neutral to ground is installed at the switchboard with ground fault detection. All switchboards and distribution panels are UL listed and sized as per regulations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2022 Resolved
A grounded alternating current system must be grounded to the hull of a metallic vessel or, on a nonmetallic vessel the neutral must be connected to a common ground. The operator removed the common ground from the starboard hull. The neutral for the dual voltage generator is not connected to a common ground. The common ground is missing in the starboard hull. 46 CFR 183.376(d)
Action required: 705 - Other - as specified
Due 2 October 2022
Resolved 17 November 2022
Resolution: The common ground is in the port hull and an approved conductor sized IAW regulations is now connecting the neutral to the common ground from the stbd hull across the deck.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2022 Resolved
Per 46 CFR 183.376(a), there must only be a single neutral connection to ground in a grounded distribution system, regardless of the number of power sources. When the power source is onboard the vessel, this ground connection must be at the switchboard. When connected to shore power the vessel neutral to ground bond must be severed because the shore power neutral to ground to neutral connection is made at the service entrance panel on shore. If this neutral to ground bond is not broken, the neutral to ground bond onboard the vessel will create a parallel circuit and neutral current will flow on both the shore power neutral and the shore power safety ground. This presents an electric shock hazard, posing a threat to passengers and crew, and also may create stray currents that endanger any swimmers or divers in close proximity to the SPV. The current shore power connection to the vessel was found with a dead end grounding conductor presenting a hazard to the vessel and personnel. The electrical installation onboard does not provide the ability for the permitted shore power connection to be installed in a manner to comply with 46 CFR 183.376(a). Submit electrical plans to MSC that illustrate the proper shore power installation in order to prevent an improper neutral to ground bond onboard the vessel. Contact USCG MI for verification of installation once plans are approved. 46 CFR 183.376(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2022
Resolved 17 November 2022
Resolution: MSC plans were approved for a disconnect breaker to be installed at the switchboard to disconnect the shore neutral which breaks the shore side neutral to ground when on the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2022 Resolved
Metallic enclosures and frames of electrical equipment must be permanently bonded to the common ground on a non metallic vessel. The common ground was removed in the starboard hull and all electrical metallic enclosures were found without a bond to the common ground. Size grounding conductors IAW 46 CFR 183.372(c). 46 CFR 183.372(a)
Action required: 705 - Other - as specified
Due 2 October 2022
Resolved 17 November 2022
Resolution: All metallic enclosures were found bonded to the common ground.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 February 2022 Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Port forward railing found fractured at the port bow. 46 CFR 177.35-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 11 March 2022
Resolution: The owner ordered replacement metal to crop and renew in the next credit dry dock. The owner designated the area as a no passenger area until repairs to the railing are completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2022 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Overcurrent protection for the conductor between the DC panel and the inverters is missing. 46 CFR 183.380
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2022
Resolved 11 March 2022
Resolution: Inspected UL listed fuse installed to protect the current carrying conductor. The fuse was sized in accordance with the conductor's current carrying capacity.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2022 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Overcurrent protection for the conductor between the battery switch and DC panel in the port and stbd engine room is missing. 46 CFR 183.380
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2022
Resolved 11 March 2022
Resolution: Inspected UL listed fuse installed to protect the current carrying conductor. The fuse was sized in accordance with the conductor's current carrying capacity.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2022 Resolved
A dual voltage generator installed on a vessel shall be of the grounded type, where: The neutral of a dual voltage system must be solidly connected at the switchboard's neutral bus and the neutral bus shall be connected to ground. The neutral of a dual voltage system must be accessible for checking the insulation resistance of the generator to ground before the generator is connected to the bus. Ground detection must be provided that: for an alternating current system, meets § 111.05-27 in subchapter J of this chapter. The dual voltage generator onboard with a manufacturer date of 2006 was installed without ground fault detection and the neutral is not connected to ground at the first disconnect. 46 CFR 183.324
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 22 November 2022
Resolution: Cleared. See activity 7549577 for more details.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Identified three floor frames with wood decay in stbd compartment 2. 46 CFR 176.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 8 June 2022
Resolution: The operator cropped and renewed the decayed floor frames in the stbd number 2 compartment like and in kind.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Transverse frame over starboard shaft in compartment 3 found with wood decay. 46 CFR 176.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 8 June 2022
Resolution: The operator cropped the decayed wood on the transverse frame over the starboard shaft in compartment 3 and replaced like and in kind.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Identified wood decay on the inboard bulkhead upper frame at attachment to forward bulkhead in stbd steering space. 46 CFR 176.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 8 June 2022
Resolution: The operator removed the inboard bulkhead upper frame at attachment to forward bulkhead in stbd steering space and replaced like and in kind.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Transverse floor frame found with wood decay under starboard rudder post. 46 CFR 176.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 8 June 2022
Resolution: The wood decay was cropped from the transverse floor frame under starboard rudder post. The operator dried out the wood, plain scarfed into the existing wood, and sistered the frame on both sides using lag bolts and epoxy glue to sister.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Wood decay found on the FWD water tight bulkhead bottom frame in the port steering space. 46 CFR 176.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 8 June 2022
Resolution: The operator dried out the wood on the FWD water tight bulkhead and the MI re-inspected the space. The wood appeared satisfactory for continued service after re-inspection and no repairs were completed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Floor frame found with wood decay under port rudder post. 46 CFR 176.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 8 June 2022
Resolution: The floor frame under the port rudder post was replaced like and in kind by the operator.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 February 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Wood decay found on water tight bulkhead inboard vertical frame in stbd forward compartment number 1. 46 CFR 176.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 8 June 2022
Resolution: The inboard vertical frame in the stbd forward #1 compartment was cropped and renewed like and in kind.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Wood decay found in overhead transverse beam in port forward compartment 1. 46 CFR 176.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 8 June 2022
Resolution: The overhead transverse beam in port forward compartment # 1 was cropped and renewed like and in kind by the operator.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 February 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Four longitudinal inboard side shell frames found fractured in the port side compartment 2 and one transverse floor frame found holed with wood decay. 46 CFR 176.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 8 June 2022
Resolution: Four longitudinal inboard side shell frames and one transverse floor frame in the port side compartment # 2 were cropped and renewed like and in kind by the operator.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 February 2021 Resolved
All machinery shall be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Inspectors identified diesel leak on the fuel return line after racor fuel filter housing for the port main diesel engine. Vessel operator repaired the pipe prior to getting underway removing pipe and resealing. Operational test SAT. 46 CFR 182.01-5 "Old T"
Action required: 10 - Deficiency Rectified
Resolved 16 February 2021
Resolution: O/O repaired pipe by removing pipe and resealing.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 February 2021 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. The float-free link required by 180.130(a)(1) must be of proper strength for the size of the life float as indicated on its identification tag. Inspectors were unable to determine the breaking strength of 04 float-free links due to missing identification tags. The links were also stretched and twisted. The vessel operator replaced all links except the one on the 8 person life float. Passenger count is reduced to 67 until float-free link is replaced. 46 CFR 180.137 (b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2021
Resolved 22 February 2021
Resolution: O/O replaced 8 person life float weak link.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 February 2021 Resolved
A life float must be approved under series 160.027. The color of the buoyant apparatus must be primarily vivid reddish orange. The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float. The 8 person life float was severely faded and the person capacity was not visible. Passenger count is reduced to 67 until life float is repaired. 46 CFR 180.200(a)(2) 46 CFR 160.010-4(n) 46 CFR 185.604(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2021
Resolved 9 March 2021
Resolution: Life float was repainted with [name withheld] paint and restinciled with name and passenger count.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2021 Resolved
A number of child size life jackets equal to at least 10% of the number persons permitted on board must be provided. 01 child life jacket was unserviceable. Child passenger count reduced to 07 until life jacket is replaced. 46 CFR 180.71(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2021
Resolved 22 February 2021
Resolution: O/O replaced child life jacket. Child count restored to 8.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 February 2021 Resolved
Each flare must be stowed in a portable container marked as required by 185.614 of this chapter. Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: ‘‘DISTRESS SIGNALS’’. The portable container was severely corroded and the bottom was rusted out. 46 CFR 180.68 (e)(1) 46 CFR 185.614
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2021
Resolved 9 March 2021
Resolution: O/O obtained a new bright red watertight container with DISTRESS SIGNALS stenciled on the side.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 February 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Coast Guard Light List. The Light List onboard was from 2019. Replace with up-to-date version. 46 CFR 184.420 (a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2021
Resolved 9 March 2021
Resolution: O/O replaced old List Light with 2021 version.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 February 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The items contained in first-aid kit shall be as listed in Table 160.041-4(b). Aspirin supplied in the first-aid kit was expired. Operator provide new non-expired aspirin. 46 CFR 184.710 46 CFR 160.041-4(b)
Action required: 10 - Deficiency Rectified
Due 16 February 2021
Resolved 16 February 2021
Resolution: Operator provided new non-expired aspirin.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 February 2020 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's hydrostatic release expired on January, 2019. Vessel owner replaced on the spot. - 46CFR180.64
Action required: 10 - Deficiency Rectified
Resolved 3 February 2020
Resolution: Vessel owner replaced on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 February 2020 Resolved
Each life float must be secured to the vessel by a painter with a float-free link permanently attached to the vessel; certified to meet § 160.073 in subchapter Q of this chapter or of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Float-free link on starboard bottom life float was wasted and float-free link on port top life float was larger gauge and incorrectly sized for 12pax life float. Vessel owner replaced on the spot. - 46CFR180.137(b)
Action required: 10 - Deficiency Rectified
Resolved 3 February 2020
Resolution: Vessel owner replaced on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 February 2020 Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. Aft-most port side bridge safety glass is cracked. - 46CFR177.1030(a)
Action required: 705 - Other - as specified
Resolved 16 February 2021
Resolution: Aft-most port side bridge safety glass was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 March 2019 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. MI observed 02 life float water lights extinguished. Replace. 46 CFR 180.175 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2019
Resolved 14 March 2019
Resolution: Operator replaced water light batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 March 2019 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed tear/hole on inside grab line of life float. Repair. 46 CFR 176.808 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2019
Resolved 14 March 2019
Resolution: Operator repaired hole in grab line.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 March 2019 Resolved
The number of persons capacity and name of a vessel must be marked or painted in clearly legible letters and numbers on each life float. Ensure all (07) life floats are marked as required. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2019
Resolved 14 March 2019
Resolution: Operator properly marked life floats with capacity and vessel name.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 March 2019 Resolved
A vessel must comply with the applicable requirements for any radio installation as set forth in 47 CFR part 80. Vessel's VHF radio was missing GPS input. Repair. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2019
Resolved 14 March 2019
Resolution: Operator provided GPS input to VHF radio.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2019 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. MI observed electrical wiring passing through holes centerline bulkhead in engine room compartment. Seal penetrations. 46 CFR 176.800 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2019
Resolved 14 March 2019
Resolution: Operator sealed electrical penetration.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 February 2018 Resolved
Replace battery and prove operation of life float water light. 46CFR180.70
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 8 February 2018
Resolution: Operator purchased new light.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 February 2018 Resolved
Replace missing guard on exposed hazard port side MDE. 46CFR177.960
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 9 February 2018
Resolution: Operator reinstalled guard.
Engineering › Bilge Water Management System › Strainer
Issued 5 February 2018 Resolved
Replace missing bilge suction strainers in fuel compartments port and starboard sides. 46CFR182.510(b)
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 9 February 2018
Resolution: Operator installed strainers on bilge suction lines.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 February 2018 Resolved
Replace expired items in first aid kit, meeting CG approval series 160.041. 46CFR184.710
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 8 February 2018
Resolution: Operator purchased approved first aid kit.
Engineering › Fuel Oil Service System › Piping
Issued 7 February 2017 Resolved
Replace strbd engine fuel line from secondary filter to engine. 46CFR182.455
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 17 February 2017
Resolution: Replaced fuel lines on starboard side of filter to engine.
Engineering › Fuel Oil Service System › Valve
Issued 7 February 2017 Resolved
Properly label fuel shut off valve. 46CFR182.455
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 17 February 2017
Resolution: Provided label for portside emergency fuel shutoff valve.
Stability › Watertight Integrity › General
Issued 7 February 2017 Resolved
Port/strbd hatches require permanent connections. 46CFR179.360
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 21 February 2017
Resolution: Provided permanent connections for port/strbd hatches.
Construction/Loadline › Hull › Hull Plating
Issued 8 September 2016 Resolved
Provide repair proposal for port strut assembly where wasted. Remove backing plate and make available for inspection IAW 46 CFR 176.25-5
Due 28 September 2016
Resolved 29 September 2016
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 February 2016 Resolved
Vessel is restricted to 53 adults and 6 children until proper lifejackets are acquired IAW 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 26 February 2016
Stability › Weathertight Integrity › General
Issued 1 February 2016 Resolved
Make portside access to engine room weathertight IAW 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 26 February 2016

Casualty record · 3

22 February 2005Routine · role: Involved in a Marine Casualty · activity 2386089
11 August 2011Routine · role: Involved in a Marine Casualty · activity 4113351
17 August 2023Routine · role: Involved in a Marine Casualty · activity 7771368
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.