MAURY USCG vessel records Sign in
← All vessels

ROYAL PRINCESS

ROYAL PRINCESS is a 1969 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1985, most recently in July 2006, along with 184 deficiencies and 1 casualty investigation in 2003.

Records from 1985 to 2006. Most recent: inspection, 10 July 2006.

Built
1969
Last inspected
10 July 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCX8216
Flag
UNITED STATES
—
Maury page id
psix-46451

Inspections, by type

…with no type recorded17
Years with a record 22 calendar years (1985–2006)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCX8216MMSI not assigned · expired · compulsorily equipped · granted 31 October 1997, cancelled 5 January 2008
WCH6459MMSI not assigned · expired · compulsorily equipped · granted 31 May 1994, cancelled 1 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

10 July 2006 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2708241
2 March 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2594914
2 February 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2578059
10 May 2005 Administrative Inspection
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2355069
8 December 2004 Drydock Extension
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2255666
10 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2063876
10 May 2004 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2063929
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977774
3 December 2003 Annual Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1933938
14 August 2003 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2231023
13 June 2003 Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1846530
12 December 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1710503
8 October 2002 Deficiency Check · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1677390
26 October 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1073954
15 October 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1423662
19 October 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 823184
11 October 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391389
18 October 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1446831
9 December 1998 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368961
21 October 1998 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372391
4 August 1998 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1127958
1 April 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 787495
23 October 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372024
15 July 1997 Excursion Permit
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1115302
3 April 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1106699
23 December 1996 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 863368
25 October 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1431675
25 September 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357741
29 March 1996 Deficiency Check · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374544
17 July 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1431551
20 September 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 371004
5 July 1994 Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354914
19 May 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 16388
2 March 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377129
2 August 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1158982
3 March 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1150475
14 January 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1140911
12 November 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1136943
30 September 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 954477
9 September 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 938422
1 September 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 959964
31 August 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 102135
4 August 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1261912
14 June 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1429689
4 June 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 113121
6 December 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1005731
11 October 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1433923
17 September 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1249609
9 August 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 933824
1 July 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1249793
10 June 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 931547
9 August 1990 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902499
29 December 1989 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1229444
1 September 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 887316
15 December 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 899216
1 November 1988 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1205007
29 September 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1201637
1 September 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 890126
21 July 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1036085
30 June 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1034157
21 June 1988 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1343558
25 April 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1195742
30 March 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1345265
16 March 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1345447
5 October 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1013523
3 September 1987 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1004648
26 August 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1312167
22 June 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1315626
18 April 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1010273
25 November 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1018861
9 September 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1000479
22 August 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989716
14 May 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 999717
25 April 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1306331
26 February 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1293177
19 February 1986 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1297117
12 December 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 997986
28 September 1985 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1304008
27 September 1985 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1300893
19 September 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 990614
12 September 1985 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989145
13 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 981552

Deficiency record · 184

Navigation › Piloting/Steering › Magnetic Compass
Issued 10 July 2006 Resolved
Require compass deviation table to be updated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2007
Resolved 19 November 2007
Resolution: Vessel sold to Brazil, no longer operating in US waters, COI invalid.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 July 2006 Resolved
Crew/operator required to be on random drug/alcohol program.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2007
Resolved 19 November 2007
Resolution: Vessel sold to Brazil, no longer operating in US waters, COI invalid.
Personnel › Training › Familiarization Training
Issued 10 July 2006 Resolved
Conduct underway drills fire/man overboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2007
Resolved 19 November 2007
Resolution: Vessel sold to Brazil, no longer operating in US waters, COI invalid.
Construction/Loadline › Hull › Weld
Issued 8 December 2004 Resolved
Lower void in the forepeak contained diesel oil, which inhibits the ability of the inspector to inspect welds in the area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 21 December 2004
Resolution: Area cleaned and inspected.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 8 December 2004 Resolved
Oil removed from the engine room space and made ready for inspection.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2004
Resolved 21 December 2004
Resolution: Most of oil removed from the bilge. The rest must be removed prior to the dry dock inspection.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 8 December 2004 Resolved
Remove or cap pipe penetrating the watertight bulkhead just forward of the fuel tank.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2005
Resolved 24 January 2006
Resolution: Pipe has been capped.
Construction/Loadline › Structures › End Bulkhead
Issued 8 December 2004 Resolved
Remove insulation in engine room from forward of the engine cover aft and make ready for inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2005
Resolved 24 January 2006
Resolution: Inpsection was completed.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 December 2004 Resolved
Missing bolts in covers for hatches on fuel tanks. Bolts must be replaced in covers on port and starboard sides.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2004
Resolved 24 January 2006
Resolution: Bolts have been replaced.
Navigation › Piloting/Steering
Issued 10 May 2004 Resolved
Obtain updated charts and Coast pilot. LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2004
Resolved 21 May 2004
Resolution: Updated charts and Coast Pilot.
Documentation › Certificates/Documents
Issued 10 May 2004 Resolved
Original COI not posted. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2004
Resolved 21 May 2004
Resolution: Original COI posted
Fire Fighting › Structural Fire Protection - General
Issued 10 May 2004 Resolved
Repair fire doors to ensure proper closure during operations. LEGACY COMPONENT DESC: Deckhouse Construction
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 21 May 2004
Resolution: Adjusted fire doors for proper fit
Documentation › Safety/Response Plans/Programs
Issued 10 May 2004 Resolved
Update station bill with current information. LEGACY COMPONENT DESC: General Arrangement Plans
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 21 May 2004
Resolution: Updated and posted
Documentation › Certificates/Documents
Issued 10 May 2004 Resolved
Obtain new FCC SSL, provide new call sign to JUNMS, and update new call sign on Emergency Broadcast Placard. LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 21 May 2004
Resolution: Applied for and waiting delivery of FCC SSL
Documentation › Markings/Placards
Issued 10 May 2004 Resolved
Stencil current hailing port on the stern of the vessel. LEGACY COMPONENT DESC: Official Number (US)
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 21 May 2004
Resolution: Painted out old hailing port and installed new hailing port.
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 May 2004 Resolved
Provide signage for the location of the First Aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 21 May 2004
Resolution: Placard posted on machinist locker with first aid kit sign
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 May 2004 Resolved
Modify rail openings to meet excursion vsl standards per 46CFR116.900(f)(1). LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 5 July 2006
Resolution: Deck Railings meet standards.
Lifesaving › Lifebuoys
Issued 10 May 2004 Resolved
Add type 2 retro-reflective tape to ring lifebuoys. LEGACY COMPONENT DESC: Retro-reflective tape
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 21 May 2004
Resolution: Reflective tape installed on all ring buoys
Accommodation/Occupational Safety › Occupational Safety
Issued 10 May 2004 Resolved
Install guards/covers in machinery space for exposed belts and steering pump shaft. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 21 May 2004
Resolution: Built and installed proper guards/covers for listed machinery
Construction/Loadline › Structures
Issued 10 May 2004 Resolved
Make permanent repairs to leak in sewage pipe. LEGACY COMPONENT DESC: Sewage piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 21 May 2004
Resolution: Installed stainless repair clamp to affected area of pipe
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 10 May 2004 Resolved
Replace Portable fire extinguisher in pilothouse. Use proper bracket for installation. LEGACY COMPONENT DESC: Location
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2004
Resolved 21 May 2004
Resolution: New fire extinguisher and mounting bracket installed in pilot house
Fire Fighting › Fixed Fire Detection System
Issued 15 March 2004 Resolved
Renew inoperable heat detectors in the engine room in accordance with 46 CFR 181.05-5. LEGACY COMPONENT DESC: Heat Detectors
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2004
Resolution: Heat detectors are not required and were removed from the engine room.
Fire Fighting › Ventilation Systems
Issued 15 March 2004 Resolved
Provide a means to close vents to the engine room upon activation of the fixed CO2 extinguishing system in accordance with 46 CFR 181.20-35. LEGACY COMPONENT DESC: Ducts
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 December 2003 Resolved
Conduct fire and man overboard drills to the satisfaction of attending USCG marine inspector IAW 46 CFR 122.520 and 122.524. LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2004
Fire Fighting › Means of Escape
Issued 3 December 2003 Resolved
Ensure proper operation of emergency fire doors IAW 46 CFR 116.435(c)(6). LEGACY COMPONENT DESC: Doorways
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2004
Construction/Loadline › Structures
Issued 3 December 2003 Resolved
Prove proper operation of starboard watertight hatch IAW 46 CFR 116.1160. LEGACY COMPONENT DESC: Door
Due 4 January 2004
Resolved 15 March 2004
Construction/Loadline › Structures
Issued 3 December 2003 Resolved
Replace gasket on port watertight hatch IAW 46 CFR 116.1160. LEGACY COMPONENT DESC: Door
Due 4 January 2004
Resolved 15 March 2004
Accommodation/Occupational Safety › Potable Water System
Issued 3 December 2003 Resolved
Provide screen for potable tank vent starboard side IAW 46 CFR 176.800. LEGACY COMPONENT DESC: screen
Due 4 January 2004
Resolved 15 March 2004
Fire Fighting › Means of Escape
Issued 3 December 2003 Resolved
Provide emergency lighting/placards for all emergency exits IAW 46 CFR 122.606. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2004
Electrical › Lighting (emergency)
Issued 3 December 2003 Resolved
Repair/prove proper operation of emergency lighting located center main deck under stairwell IAW 46 CFR 122.432. LEGACY COMPONENT DESC: Lighting Fixture
Due 4 January 2004
Resolved 15 March 2004
Electrical › Lighting (service)
Issued 3 December 2003 Resolved
Repair all watertight electrical receptacles IAW 46 CFR 120.210(b). LEGACY COMPONENT DESC: Outlet Box
Due 4 January 2004
Resolved 16 March 2004
Electrical › Lighting (service)
Issued 3 December 2003 Resolved
Provide watertight marine grade lighting for port and starboard lights bridge deck IAW 46 CFR 120.210(b). LEGACY COMPONENT DESC: Lighting Fixture
Due 4 January 2004
Resolved 15 March 2004
Engineering › Fuel Oil Service System
Issued 3 December 2003 Resolved
Provide J1942 approved hose for all high pressure fuel lines or meet equivalency on existing hose with the use of fire sleeves IAW 46 CFR 56.60-25(b). LEGACY COMPONENT DESC: Hose
Due 4 January 2004
Resolved 15 March 2004
Engineering › Diesel Engine (propulsion-electric)
Issued 3 December 2003 Resolved
Attach all main engine air filters IAW 46 CFR 176.800. LEGACY COMPONENT DESC: Air Cleaner
Due 4 January 2004
Resolved 15 March 2004
Engineering › Diesel Engine (propulsion-electric)
Issued 3 December 2003 Resolved
Remove excess oil from main engine air filters IAW 46 CFR 176.800. LEGACY COMPONENT DESC: Air Cleaner
Due 4 January 2004
Resolved 15 March 2004
Engineering › Diesel Engine (propulsion-electric)
Issued 3 December 2003 Resolved
Replace all armor cable where armor is not continuous IAW 46 CFR 120.340(b)(6). LEGACY COMPONENT DESC: armor cable
Due 4 January 2004
Resolved 17 March 2004
Engineering › Steering Gear System
Issued 3 December 2003 Resolved
Repair hose connector on rudder angle indicator sending unit IAW 46 CFR 58.25-25(a). LEGACY COMPONENT DESC: Rudder Angle Indicator
Due 4 January 2004
Resolved 15 March 2004
Electrical › Electric Supply System (service)
Issued 3 December 2003 Resolved
Renew connections on main engine battery start switch IAW 46 CFR 120.350(d). LEGACY COMPONENT DESC: Battery Installation
Due 4 January 2004
Resolved 17 March 2004
Electrical › Electrical Distribution System (service)
Issued 3 December 2003 Resolved
Remove all loose end wiring fwd side of main engine and reattach broken/loose wiring IAW 46 CFR 120.340. LEGACY COMPONENT DESC: Wiring
Due 4 January 2004
Resolved 15 March 2004
Construction/Loadline › Structures
Issued 3 December 2003 Resolved
Repair crack on starboard side of dive platform IAW 46 CFR 116.300. LEGACY COMPONENT DESC: dive platform
Due 4 January 2004
Resolved 15 March 2004
Pollution Prevention/Response › Prevention Equipment
Issued 3 December 2003 Resolved
Remove excess oil from bilges IAW 46 CFR 176.800.
Due 4 January 2004
Resolved 17 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 December 2003 Resolved
Provide testing for fixed CO2 system to include: (1) time delays, (2) pressure switches, (3) egress alarms, (4) engine and ventilation shut downs, and (5) remote pull stations IAW 46 CFR 115.810 and 115.810(a). Testing shall be done in the presence of USCG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 December 2003 Resolved
Hydrotest fixed CO2 storage bottles IAW 46 CFR 147.65(a). LEGACY COMPONENT DESC: Tanks
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 December 2003 Resolved
Pressure test CO2 mainfold IAW 46 CFR 176.810(a). LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2004
Engineering › Reduction Gearing/Clutches
Issued 13 June 2003 Resolved
Vessel can not sail with astern propulsion on port engine. In lieu of this, tug assist is required for all moorings. LEGACY COMPONENT DESC: Gear
Condition: Improper Installation
Due 18 June 2003
Resolved 27 June 2003
Resolution: Got underway with vessel. All sat.
Construction/Loadline › Hull › Hull Plating
Issued 12 December 2002 Resolved
Provide certified gauging report of pitted area in void 7, portside aft corner. Eight very deep pits noted, all in a transverse line, approximately 1-2 inches away from the transverse weld.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 13 December 2002
Resolution: Report provided for area indicated a 50% - 83% wastage of the 3/8" plate. Problem area was solved by a large insert, approximately 2'' x 4''.
Construction/Loadline › Structures › Door
Issued 12 December 2002 Resolved
Replace rusted hingebolt on starboard watertight door.
Action required: 705 - Other - as specified
Resolved 13 December 2002
Resolution: Old bolt extracted and replaced with a new bolt and nut.
Construction/Loadline › Structures › Door
Issued 12 December 2002 Resolved
Tighten down dog bolts on port and starboard watertight doors.
Action required: 705 - Other - as specified
Resolved 13 December 2002
Communications › Radio Communications › EPIRB
Issued 8 October 2002 Resolved
Replace EPIRB's antenna IAW 46 CFR 117.64.
Condition: Unknown
Due 15 October 2002
Resolved 8 October 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 8 October 2002 Resolved
Replace pull cable conduit at CO2 control head IAW 46 CFR 115.810. LEGACY COMPONENT DESC: Piping
Due 22 October 2002
Resolved 17 October 2002
Resolution: Replaced by Grinnell-Simplex.
Fire Fighting › Fire Hoses
Issued 8 October 2002 Resolved
Replace fire hose IAW 46 CFR 118.320. LEGACY COMPONENT DESC: Condition
Due 22 October 2002
Resolved 17 October 2002
Engineering › Generator (propulsion-electric)
Issued 8 October 2002 Resolved
Replace stbd generator's engine head IAW 46 CFR 120.310. LEGACY COMPONENT DESC: Engine head
Condition: Unknown
Due 22 October 2002
Resolved 17 October 2002
Resolution: Parts were recieved and stbd generator is back on-line.
Construction/Loadline
Issued 15 October 2001 Resolved
Provide bilge high level alarm for engine space IAW 46CFR119.530(a)(2).
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Fire Fighting
Issued 11 October 2000 Resolved
Provide Fire Control Plan IAW 46CFR116.530
Condition: Unknown
Due 20 October 2000
Resolved 20 October 2000
Unknown
Issued 29 March 1996 Resolved
VESSEL IS RESTRICTED FROM CARRIAGE OF PASSENGERS UNTIL SATISFACTORY COMPLETION OF A CREDIT DRYDOCKING.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Documentation
Issued 17 July 1995 Resolved
PROVIDE VESSEL DOCUMENTATION RENEWAL DECAL.
Condition: Unknown
Due 17 August 1995
Resolved 18 July 1995
Fire Fighting
Issued 17 July 1995 Resolved
REPAIR LEAKS IN FIRE/BILGE PUMP PRIME MOVER PIPING.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Electrical
Issued 17 July 1995 Resolved
PROPERLY REPAIR OR REMOVE ALL DEAD END WIRING.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Lifesaving
Issued 17 July 1995 Resolved
REPLACE ALL ROTTED BUOYANT APPARATUS WATER LIGHT LINES.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Electrical
Issued 17 July 1995 Resolved
PROPERLY RESPLICE ALL UNACCEPTABLE ELECTRIC WIRE SPLICES.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Lifesaving
Issued 17 July 1995 Resolved
REPLACE STARBOARD BRIDGE DECK LIFE RING LIFE LINE.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Construction/Loadline
Issued 17 July 1995 Resolved
REMOVE EXCESSIVE BILGE WATER/OIL FROM ENGINE ROOM.
Condition: Unknown
Due 17 August 1995
Resolved 18 July 1995
Documentation
Issued 17 July 1995 Resolved
PROVIDE CURRENT FCC SAFETY RADIO CERTIFICATE. VESSEL IS RESTRICTED TO OPERATE NO MORE THAN 1000 FEET FROM SHORE UNTIL THE CERTIFICATE IS ON BOARD.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Documentation
Issued 17 July 1995 Resolved
PROVIDE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Electrical
Issued 17 July 1995 Resolved
PROPERLY REPLACE ALL MISSING LIGHT GLOBES/CAGES.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Electrical
Issued 17 July 1995 Resolved
MAKE PROPER REPAIR TO EMERGENCY LIGHTING FIXTURES OR REPLACE.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Engineering
Issued 17 July 1995 Resolved
REPLACE ALL FUEL TANK VENT SCREENS.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Accommodation/Occupational Safety
Issued 17 July 1995 Resolved
PROPERLY ROUTE SEWAGE TANK VENTS.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Accommodation/Occupational Safety
Issued 17 July 1995 Resolved
REPLACE OVERHEAD IN SHOWER STALL.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Electrical
Issued 17 July 1995 Resolved
REMOVE ALL AMBIGUOUS LABELING ON ALL ELECTRIC POWER PANELS.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Navigation
Issued 17 July 1995 Resolved
SWING VESSEL AND UPDATE VESSELS DEVIATION CARD.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Navigation
Issued 17 July 1995 Resolved
INSTALL ALL AROUND WHITE MASTHEAD LIGHT FOR ANCHORING.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Fire Fighting
Issued 5 July 1994 Resolved
REPAIR THE LEAKY PACKING ON THE FIRE MAIN DISCHARGE VALVE IN THE PUMP ROOM.
Condition: Unknown
Due 12 August 1994
Resolved 7 September 1994
Fire Fighting
Issued 5 July 1994 Resolved
SUBMIT PROOF OF FIXED FIRE FIGHTING SYSTEMS BEING SERVICED.
Condition: Unknown
Due 12 August 1994
Resolved 7 September 1994
Documentation
Issued 5 July 1994 Resolved
SUBMIT WRITTEN DETAILS OF MODIFICATIONS MADE IN THE ENGINE ROOM; INCLUDE ANY CHANGES MADE TO PIPING OR EQUIPMENT.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Electrical
Issued 5 July 1994 Resolved
INSTALL METAL CLAMPS FOR VERTICAL WIRES RUN OVER THE THE PORT MAIN ENGINE.
Condition: Unknown
Due 5 August 1994
Resolved 7 August 1994
Documentation
Issued 5 July 1994 Resolved
PROVIDE SIMPLE LINE DIAGRAMS AND OPERATING INSTRUCTIONS FOR OPERATING AND BRINGING ON-LINE THE FOLLOWING SYSTEMS: (A) FIRE PUMPS (B) BILGE PUMPS (C) ELECTRIC GENERATORS.
Condition: Unknown
Due 5 August 1994
Resolved 7 August 1994
Construction/Loadline
Issued 5 July 1994 Resolved
REMOVE SEWAGE WATER FROM THE PUMP ROOM BILGES, VENTILATE SPACE, AND CLEAN BILGES FOR INSPECTION UNDER THE MSD HOLDING TANK.
Condition: Unknown
Due 5 August 1994
Resolved 7 August 1994
Electrical
Issued 5 July 1994 Resolved
MAKE THE FLOOD LIGHT ON THE STBD WEATHER DECK NEAR THE FORWARD BROW WEATHERTIGHT.
Condition: Unknown
Due 5 August 1994
Resolved 7 August 1994
Accommodation/Occupational Safety
Issued 5 July 1994 Resolved
MAKE PERMANENT AND PROPER REPAIRS TO THE SEWAGE INPUT LINE LOCATED AT THE TOP OF THE MSD HOLDING TANK. REMOVE SOFT PATCH IN SEWAGE LINE, REPLACE DEFECTIVE GASKETS AND HARDWARE, AND MAKE LEAK TIGHT.
Condition: Unknown
Due 12 August 1994
Resolved 7 September 1994
Electrical
Issued 5 July 1994 Resolved
REPAIR AND PROVE OPERATION OF THE DEFECTIVE AMP METERS FOR THE PORT AND STBD GENERATORS, LOCATED BEHIND THE PILOT HOUSE.
Condition: Unknown
Due 12 August 1994
Resolved 7 September 1994
Documentation
Issued 5 July 1994 Resolved
SUBMIT A DETAILED LIST OF EQUIPMENT ONBOARD THE VESSEL WHICH IS NOT OPERATIONAL; INCLUDE VENTILATION SYSTEMS, ELECTRICAL SYSTEMS, VALVES, PUMPS, ETC. ETC.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Documentation
Issued 5 July 1994 Resolved
RENEW THE FCC RADIO SAFETY CERTIFICATE. VESSEL WILL BE RESTRICTED TO NMT 1000 FT FROM SHORE UNTIL COMPLIANCE IS MET.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Electrical
Issued 5 July 1994 Resolved
IDENTIFY PROBLEMS WITH THE ELECTRICAL GENERATOR SETS, PROPERLY REPAIR, AND PROVE OPERATIONAL.
Condition: Unknown
Due 5 August 1994
Resolved 7 August 1994
Electrical
Issued 5 July 1994 Resolved
DEMONSTRATE PORT GENERATOR OPERABLE UNDER A LOADED CONDITION.
Condition: Unknown
Due 5 August 1994
Resolved 7 August 1994
Engineering
Issued 5 July 1994 Resolved
REPAIR OIL LEAK LOCATED ON THE STBD MAIN ENGINE NEAR THE OUTBOARD TURBO- CHARGER FAN UNIT.
Condition: Unknown
Due 5 August 1994
Resolved 7 August 1994
Electrical
Issued 5 July 1994 Resolved
PROPERLY REPAIR THE FRACTURE IN THE EXHAUST COOLING LINE FOR THE PORT GENERATOR.
Condition: Unknown
Due 5 August 1994
Resolved 7 August 1994
Engineering
Issued 14 January 1993 Resolved
MAKE PERMANENT REPAIRS TO THE STARBOARD OUTDRIVE. THE VESSEL IS RESTRICTEDTO 100 PASSENGERS AND ITS ROUTE IS RESTRICTED TO MAMALA BAY UNTIL REPAIRS ARE SATISFACTORILY COMPLETED.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Engineering
Issued 1 September 1992 Resolved
TROUBLE SHOOT AND DETERMINE CAUSE OF FIRE IN STBD M.E. EXHAUST AND MAKE PERMANENT REPAIR TO STARBOARD MAIN ENGINE AND EXHAUST PRIOR TO RETURNING STARBOARD M.E. TO NORMAL OPERATION. STBD M.E. IS TO BE MAINTAINED IN IN IMMEDIATE STAND BY STATUS WHEN CARRYING PASSENGERS.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Fire Fighting
Issued 1 September 1992 Resolved
PRIOR TO CARRYING PASSENGERS RECHARGE TWO DISCHARGED BII PORTABLE FIRE EXTINGUISHERS AND RETURN TO STATIONS, BRINGING TOTAL OF BII EXTINGUISHERS ON BOARD TO FIVE.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Documentation
Issued 4 August 1992 Resolved
OBTAIN A VALID FCC RADIO OPERATOR'S PERMIT (FCC FORM 848) FOR AT LEAST ONE MEMBER ABOARD THE VESSEL.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Unknown
Issued 14 June 1992 Resolved
VESSEL IS NOT ALLOWED TO CARRY PASSENGERS FOR HIRE UNTIL THE ATTACHED WORKLIST IS COMPLIED WITH (SEE MINS). VESSEL IS LIMITED TO CARRYING NO MORE THAN 100 PASSENGERS & RESTRICTED TO MAMALA BAY UNTIL THE TEMPORARY REPAIRS ARE COMPLETE.
Condition: Unknown
Due 26 June 1992
Resolved 16 July 1992
Construction/Loadline
Issued 9 August 1991 Resolved
Make deck between galley and void #1 watertight.
Condition: Unknown
Due 11 October 1991
Resolved 11 October 1991
Navigation
Issued 9 August 1991 Resolved
Renew navigational light control panel. Submit wiring diagram to this office for approval._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 October 1991
Resolved 11 October 1991
Navigation
Issued 9 August 1991 Resolved
Replace all navigational lights with UL approved lights.
Condition: Unknown
Due 11 October 1991
Resolved 11 October 1991
Engineering
Issued 9 August 1991 Resolved
Provide appropriate flame screens (30X30 mesh) for fuel tank vents.
Condition: Unknown
Due 11 October 1991
Resolved 11 October 1991
Construction/Loadline
Issued 9 August 1991 Resolved
REPLACE THE MISSING DOGS IN THE PORT AND STARBOARD PORT DOORS AND MAKE _x001C_ THEM WATERTIGHT.
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Engineering
Issued 29 December 1989 Resolved
INSTALL GUARDS OVER ENGINE DRIVE SHAFT, COUPLING AND ULSTIEN INPUT SHAFT.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Accommodation/Occupational Safety
Issued 29 December 1989 Resolved
PRIOR TO INSTALLATION, PROVIDE FOR CG REVIEW, SPECIFICATIONS/DATA ON CARPET, WALL COVERINGS, STANCHION COVERINGS, ETC.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Engineering
Issued 29 December 1989 Resolved
PROVIDE LINE DIAGRAM INDICATING PROPOSED ALTERATIONS TO FUEL LINES IN ENGINEROOM AND LIST OF MATERIALS AND FITTINGS TO BE USED.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Accommodation/Occupational Safety
Issued 29 December 1989 Resolved
PROVIDE SUITABLE MOUNTINGS FOR FRESH WATER LINES, FORE AND AFT, ALL COMPARTMENTS.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Construction/Loadline
Issued 29 December 1989 Resolved
PROVIDE GAUGING REPORT FROM DECEMBER 1989 DRYDOCKING.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Engineering
Issued 29 December 1989 Resolved
PROVIDE MANUFACTURER SPECIFICATIONS AND DATA ALLOWING " CHAULK FAST (PHILADELPHIA GREY) BEDDING COMPOUNDS USE ON HULL EXTERIOR AND ULSTIEN DRIVE RECCOMMENDING ITS USE.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Engineering
Issued 29 December 1989 Resolved
REMOVE PROPELLERS FROM TAILSHAFTS FOR CG INSPECTION OF TAILSHAFTS AT NEXT CREDIT DRY DOCK EXAM.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Construction/Loadline
Issued 29 December 1989 Resolved
RENEW EXISTING FIN STABILIZER THRU HULL INSERTS, PORT AND STBD, FORE AND AFT, WITH 18" MINIMUM CIRCULAR INSERT NEXT CEDIT DRY DOCK EXAM.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Electrical
Issued 29 December 1989 Resolved
PROVIDE COAST GUARD ACCEPTABLE WIRE MOUNTINGS FOR BILGE WATER SENSOR SYSTEM
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Engineering
Issued 29 December 1989 Resolved
INSTALL BILGE WATER SENSOR INBETWEEN FRAMES 47 AND 49.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Accommodation/Occupational Safety
Issued 29 December 1989 Resolved
RENEW AS NECESSARY BROKEN STUDS IN ACCESS COVER FOR MSD TANK.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Engineering
Issued 1 September 1989 Resolved
PROVIDE GUARDS FOR BELTS AND PULLEYS, FLYWHEEL ON BOTH MAIN ENGINES.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Construction/Loadline
Issued 1 September 1989 Resolved
PLACE STATE INITIALS AFTER 'HONOLULU' ON VESSEL STERN.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Fire Fighting
Issued 1 September 1989 Resolved
PROVE OPERATION OF FIRE DETECTION UNITS IN ENGINE ROOM.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 1 September 1989 Resolved
PROPERLY MOUNT AND INSTALL ELECTRICAL CONTROL BOX AND AFFIX ELECTRICAL WIREFOR NEW INSTALATION SANITARY FLUSHING PUMP.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Lifesaving
Issued 1 September 1989 Resolved
POST PFD DONNING INSTRUCTIONS AS ADVISED.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 1 September 1989 Resolved
PLACE COVERS ON OPEN ELECTRICAL BOXES IN ENGINE ROOM
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 1 September 1989 Resolved
PROPERLY CONNECT BATTERY CABLES IN JUNCTION BOX.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 1 September 1989 Resolved
PERMANENTLY INSTALL, WITH C.G. APPROVED WIRE/FITTINGS AS INDICATED ON C.G. APPROVED ELECTRICAL DIAGRAM OF ENGINE ROOM, EXHAUST FAN.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 1 September 1989 Resolved
PROPERLY SUPPORT ELECTRICAL WIRING, IN GENERAL, PROPERLY TERMINATE IN ELECTRICAL BOX OR REMOVE WIRE PRESENTLY HAVING EXPOSED ENDS.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 1 September 1989 Resolved
PROVIDE GLOBES FOR LIGHT FIXTURES THROUGHOUT VESSEL.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Accommodation/Occupational Safety
Issued 1 September 1989 Resolved
PROVIDE RIGID SUPPORT FOR MSD TANK DISCHARGE (SUCTION) LINE.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Fire Fighting
Issued 1 September 1989 Resolved
MARK/LAAAAAAAAAAABEL FIRE PUMP/ BILGE PUMP/ SANITARY PUMP VALVES AND PERMANENTLY AFFIX DIAGRAM AND OPERATING INSTRUCTIONS.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 1 September 1989 Resolved
PROPERLY TERMINATE ELECTRICAL WIRING, IN LADIES RESTROOM, OVERHEAD LIGHTING
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 1 September 1989 Resolved
BLOCK ENGINEROOM BATTERIES.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 1 September 1989 Resolved
RENEW BATTERY CABLE TERMINALS WITH USCG MARINE APPROVED TERMINALS.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Accommodation/Occupational Safety
Issued 1 September 1989 Resolved
RENEW THRU HULL (DECK) MSD DISCHARGE (SUCTION) LINE WITH RIGID, SEALED, C.G. ACCEPTABLE LINE AND FITTINGS.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Fire Fighting
Issued 1 September 1989 Resolved
AFFIX VESSEL NAME TO FIRE AXE HANDLE.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Navigation
Issued 1 September 1989 Resolved
PROVE, AS MANUFACTURED, OPERATION OF VESSEL RADAR.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Lifesaving
Issued 1 September 1989 Resolved
NO MORE THAN 138 ADULT AND 35 CHILD PASSENGERS MAY BE CARRIED ABOARD VESSELUNTIL THE REMAINING 124 ADULT PFD'S HAVE THE REQUIRED REFLECTIVE MATERIAL ADDED.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Construction/Loadline
Issued 1 September 1989 Resolved
SUBMIT FORMAL SCHEDULE AND DETAILED PLAN, INCLUDING ALL MATERIALS, FOR THE INSTALATION OF THE STRUCTURAL FIRE PROTECTION IN PUMP ROOM.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Documentation
Issued 1 September 1989 Resolved
ROUTE RESTRICTED TO LAKES, BAYS, AND SOUNDS - MAMALA BAY - UNTIL ALL PREVIOUS OUTSTANDING 835'S CLEARED.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Navigation
Issued 1 September 1989 Resolved
SUPPLY CURRENT CHARTS AND NAUTICAL PUBLICATIONS AS APPROPRIATE FOR ROUTE AND SERVICE.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Lifesaving
Issued 1 September 1989 Resolved
ATTACH PENDENTS TO BOUYANT APPARATUS AS REQUIRED.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Construction/Loadline
Issued 1 September 1989 Resolved
SUPPLY MSO HONOLULU WITH COAST GUARD APPROVED PRINTS FOR VESSEL AS IS AT PRESENT.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Engineering
Issued 1 September 1989 Resolved
INSTALL MARINE APPROVED RACOR FUEL OIL FILTER BOWL SHIELDS.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Engineering
Issued 1 September 1989 Resolved
REPLACE FLEXIBLE FUEL OIL SUPPLY AND RETURN LINES. MAXIMUM FLEX LINE LENGTHNOT TO EXCEDE 36 IN.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Electrical
Issued 1 September 1988 Resolved
RENEW DETERIORATED GENERATOR START BATTERY BOX AND PROVIDE SUITABLE LINING FOR SAME.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Accommodation/Occupational Safety
Issued 1 September 1988 Resolved
MAKE OPERABLE FORWARD TOILET IN WOMEN'S HEAD.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Accommodation/Occupational Safety
Issued 1 September 1988 Resolved
REPAIR FRACTURED PVC WATER DRAIN LINE LOCATED FORWARD AREA OF VOID #3.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Electrical
Issued 1 September 1988 Resolved
SECURE DANGLING ELECTRICAL CABLES IN GALLEY OVERHEAD.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Construction/Loadline
Issued 1 September 1988 Resolved
PROVIDE MEANS OF CLOSURE FOR ENGINE ROOM FRESH AIR VENTS.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Navigation
Issued 1 September 1988 Resolved
RENEW FCC RADIO STATION LICENSE.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Construction/Loadline
Issued 1 September 1988 Resolved
PROMINENTLY LABEL BILGE MANIFOLD VALVES.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Accommodation/Occupational Safety
Issued 1 September 1988 Resolved
PROVIDE COVER PLATE FOR FLUSHING PUMP ELECTRICAL MOTOR CONTROLLER.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Lifesaving
Issued 1 September 1988 Resolved
REPAIR FIBERGLASS FRACTURE ON CORNER OF BUOYANT APPARATUS SERIAL #282 (BOTTOM RACK, PORT SIDE).
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Construction/Loadline
Issued 21 June 1988 Resolved
CONDUCT SATISFACTORY TEST OF FIN STABILIZER.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Fire Fighting
Issued 21 June 1988 Resolved
RENEW STRUCTURAL INSULATION IN PUMP ROOM OVERHEAD WITH USCG APPROVED A60 INSULATING MATERIAL.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Fire Fighting
Issued 21 June 1988 Resolved
PROVIDE MEANS OF CLOSURE FOR VENTILATION INTO PUMP ROOM.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Electrical
Issued 25 April 1988 Resolved
DEMONSTRATE PROPER OPERATION OF ALL BILGE LEVEL ALARMS.
Condition: Unknown
Due 25 April 1988
Resolved 25 April 1988
Electrical
Issued 16 March 1988 Resolved
PROVIDE PROPER SIZED WIRE GLANDS FOR BILGE ALARM SYSTEM FOR JUNCTION BOXES AND WATERTIGHT BULKHEAD PENETRATIONS AND INSTALL ALARM FOR ENGINE COMPARTMENT.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Electrical
Issued 16 March 1988 Resolved
INSTALL COVER MISSING FROM JUNCTION BOX PORT SIDE.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Engineering
Issued 16 March 1988 Resolved
INSTALL PROTECTIVE GUARD FOR TWO MOTOR/PUMP SHAFT COUPLING IN MSD COMPARTMENT AND ON PORT MAIN ENGINE.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Fire Fighting
Issued 3 September 1987 Resolved
PROVIDE 3 ADDITIONAL SPANNER WRENCHES FOR ONE AT EACH OF 6 FIRE STATIONS.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Electrical
Issued 3 September 1987 Resolved
PROVIDE NONCONDUCTING MAT OR GRATING IN FRONT OF SWITCH BOARDS IN ENGINE ROOM AND AFT OF BRIDGE.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Engineering
Issued 3 September 1987 Resolved
INSTALL ADEQUATE VENTILATION IN SPACE #5 TO ENSURE ADEQUATE MOISTURE REMOVAL OF AIR BEING COMPRESSED FOR THROTTLE CONTROL SYSTEM.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Construction/Loadline
Issued 3 September 1987 Resolved
INSTALL MAIN DECK WATERTIGHT CLOSURES TO 3 ACCESSES TO VOID NO. 7, V-DRIVE SPACE, LOCATED IN MAIN LOUNGE.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Fire Fighting
Issued 3 September 1987 Resolved
MAKE OPERABLE FIRE CLOSURES PORT AND STARBOARD BETWEEN UPPER DECK FOYER AND OUTSIDE.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Fire Fighting
Issued 3 September 1987 Resolved
MAKE OPERABLE CLOSURE LOUVERS PORT AND STARBOARD SIDE OF UPPER DECK AIR HANDLING ROOM.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Fire Fighting
Issued 3 September 1987 Resolved
REMOVE OR MAKE OPERABLE PYROTRONICS FIRE DETECTION SYSTEM. TEST FLAME 5 SCANNERS AND 2 SMOKE DETECTORS AS WELL AS 1 RATE OF RISE SENSOR IN MARINETICS PANEL.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Engineering
Issued 3 September 1987 Resolved
MAKE OPERABLE SHUTOFF VALVES TO CUTLASS BEARING COOLING WATER LINES.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Engineering
Issued 3 September 1987 Resolved
PROPERLY SUPPORT ALL FLEXIBLE FUEL LINES TO PROPULSION ENGINES AND GENERATORS IN ENGINE ROOM.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Navigation
Issued 3 September 1987 Resolved
PROPERLY SUPPORT FLEXIBLE HYDRAULIC HOSES TO STARBOARD STEERING CYLINDER IN ENGINE ROOM.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Electrical
Issued 3 September 1987 Resolved
REMOVE DEAD END CABLES IN V-DRIVE ROOM AND NO. 6 VOID.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Electrical
Issued 3 September 1987 Resolved
REMOVE OR INSTALL PROPER MARINE TYPE OUTLET BOXES AND JUNCTION BOXES IN V-DRIVE ROOM, FORWARD ROPE LOCKER AND NO. 6 VOID POTABLE WATER TANK SPACE.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Electrical
Issued 3 September 1987 Resolved
HARD WIRE V-DRIVE SALT WATER COOLING PUMP IN NO. 7 VOID, V-DRIVE SPACE.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Electrical
Issued 3 September 1987 Resolved
PROPERLY WIRE COMPRESSOR MOTOR JUNCTION BOX IN COMPARTMENT NO. 5 PUMPROOM.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Electrical
Issued 3 September 1987 Resolved
REMOVE OR PROPERLY WIRE BILGE ALARM SYSTEM AND JUNCTION BOXES IN HULL COMPARTMENTS NOS. 1-8.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Construction/Loadline
Issued 3 September 1987 Resolved
MAKE REACH RODS AND VALVES IN PVC LINE THROUGH WATERTIGHT BULKHEAD NO. 40 OPERABLE AND ACCESSIBLE OR OTHERWISE INSTALL IN ACCORDANCE WITH 46 CFR 182.40-1.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Lifesaving
Issued 3 September 1987 Resolved
PROVIDE 31 ADDITIONAL ADULT PFDS. UNTIL SUCH TIME TOTAL PERSONS ALLOWED ON BOARD IS REDUCED TO 422.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Lifesaving
Issued 3 September 1987 Resolved
INSTALL 2 ADDITIONAL WATERLIGHTS FOR A TOTAL OF 81, 1 ON EACH OF 8 BUOYANT APPARATUS.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Lifesaving
Issued 3 September 1987 Resolved
PROVIDE 3 ADDITIONAL HAND HELD ORANGE SMOKE FLARES.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Unknown
Issued 9 September 1986 Resolved
DEMONSTRATE PROPER OPERATION OF THE EMERGENCY SHUTOFF SYSTEM TO THE MAIN ENGINES.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Unknown
Issued 9 September 1986 Resolved
PREPARE GALLEY AREA FOR SANITATION INSPECTION.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Unknown
Issued 9 September 1986 Resolved
POST ON BOARD VESSEL A VALID FCC FORM 824.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Unknown
Issued 22 August 1986 Resolved
INSTALL SPRAY SHIELDS ON ALL PLASTIC RACOR FUEL FILTERS IN THE ENGINE ROOM.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Unknown
Issued 25 April 1986 Resolved
SUBMIT A PROPOSAL FOR PLAN REVIEW AND ACCOMPLISH INSTALLATION OF A VENTILATION SYSTEM IN THE MACHINERY SPACE, IN ACCORDANCE WITH 46 CFR 182.20-45.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Construction/Loadline
Issued 19 February 1986 Resolved
REPLACE OR MAKE PERMANENT REPAIRS TO STARBOARD BRIDGE DOOR.
Condition: Unknown
Due 19 February 1986
Resolved 19 February 1986
Electrical
Issued 19 September 1985 Resolved
MAKE OPERABLE AND DEMONSTRATE PORT AND STARBOARD ELECTRICAL GENERATORS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 September 1985
Resolved 19 September 1985
Fire Fighting
Issued 12 September 1985 Resolved
PROVIDE FOR ANNUAL SERVICING AND HYDRO TESTING OF ALL B-II FIRE EXTINGUISHERS AND ANNUAL SERVICING OF B-III EXTINGUISHER.
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Documentation
Issued 12 September 1985 Resolved
PLACE ON BOARD UNDER TRANSPARENT COVER VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Lifesaving
Issued 12 September 1985 Resolved
REPLACE 20 ADULT LIFE PRESERVERS. TOTAL PERSONS ALLOWED UNTIL SUCH TIME SHALL BE REDUCED TO 436.
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Lifesaving
Issued 12 September 1985 Resolved
PROVIDE WEAK LINK ASSEMBLY FOR ALL BUOYANT APPARATUS.
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Lifesaving
Issued 12 September 1985 Resolved
REPLACE STARBOARD SIDE LIFE RING.
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Lifesaving
Issued 12 September 1985 Resolved
REPAIR OR REPLACE WATERLIGHT FOR PORT SIDE LIFE RING.
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Deck/Cargo
Issued 12 September 1985 Resolved
REPAIR OR REPLACE AFT CAPSTAN.
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Electrical
Issued 12 September 1985 Resolved
REPAIR OR REPLACE PORT GENERATOR.
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Fire Fighting
Issued 13 June 1985 Resolved
REPLACE FLEXIBLE HOSE CONNECTED TO FIRE MAIN SUCTION LINE WITH STEEL PIPING.
Condition: Unknown
Due 13 June 1985
Resolved 13 June 1985

Casualty record · 1

14 August 2003Routine · role: Involved in a Marine Casualty · activity 2231023
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.