← All vessels

FISHER

FISHER is a 1999 freight ship. The Coast Guard has recorded 45 inspections since 2016, most recently in March 2026, along with 28 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 4 March 2026.

Built
1999
Last inspected
4 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 March 2026
…with no type recorded4
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9116826
464635
Flag
UNITED STATES
Maury page id
psix-464635

Documentation record

Registered dimensions (L × B × D)890.3 ft × 105.8 ft × 90.3 ft
Registered tonnagegross 69,365 / net 20,809
ITC dimensions (L × B × D)890.3 ft × 105.8 ft × 90.3 ft
ITC tonnagegross 69,365 / net 20,809
BuilderNORTHROP GRUMMAN SHIP SYSTEMS AVONDALE · AVONDALE, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20809 - Convention (Subpart B), Net Ton
29151 - Dead Weight, Ton
58255 - Displacement, Ton
69365 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 45

4 March 2026 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8320427
13 August 2025 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8209444
5 June 2025 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8152820
5 February 2025 Re-Inspection · MTSA/ISPS Verification · COI Inspection · ACP COI Oversight
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8015676
4 December 2024 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8043210
17 July 2024 ISM Oversight · Administrative Inspection · In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7961627
13 November 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7824018
25 April 2023 Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7678967
20 November 2022 Periodic Inspection · Administrative Inspection · ACP Periodic Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7601355
19 September 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7562128
1 September 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7585583
16 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7585523
11 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7585512
9 August 2022 ISM SMC Audit · ISM Oversight
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7528168
2 November 2021 ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7356350
21 October 2021 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7337513
27 August 2021 Administrative Inspection · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7298452
23 August 2021 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7293896
18 June 2021 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7228812
30 May 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7210495
19 May 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7202828
30 April 2021 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7194745
5 November 2020 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7090100
20 October 2020 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7082993
3 February 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6901764
26 November 2019 Administrative Inspection · ACP Drydock Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6863163
1 November 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6846970
20 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6817013
20 September 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6817103
19 August 2019 Annual Inspection · ACP COI Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6787993
23 July 2019 Administrative Inspection · Drydock Extension
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6759151
15 July 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6751047
19 October 2018 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6564759
14 August 2018 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6512306
27 November 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6313091
14 July 2017 Annual Inspection · Deficiency Check · Administrative Inspection · ACP Additional Oversight – Risk Assessment
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6274598
12 July 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6207574
20 June 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6181719
28 May 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6161634
28 May 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6183579
26 January 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6078140
14 January 2017 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6071778
23 August 2016 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5983323
26 February 2016 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5822877
24 February 2016 Re-Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5821220

Deficiency record · 28

04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 5 June 2025 No resolution recorded
The inspection for certification shall include an inspection of the structure, boilers, and other pressure vessels, machinery, and equipment. The inspection shall be such as to insure that the vessel, as regards the structure, boilers and other pressure vessels, and their appurtenances, piping, main and auxiliary machinery, electrical installations, lifesaving appliances, firedetecting and extinguishing equipment, pilot boarding equipment, pollution prevention equipment, and other equipment, is in satisfactory condition and fit for the service for which it is intended. Inspector not limited. (a) Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel. You are required to provide a plan for conducting a "fully functional test" of the vessels dewatering system (including suction and discharge using the vessels installed dewatering pumps). After this plan is approved by the Coast Guard, you are required to perform an operational test of the dewatering system witnessed by ABS and the Coast Guard. This test is to be conducted during the vessel's next drydock or the vessel's next Inspection for Certification (whichever occurs first). *Plan required in 90 days
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2025 — due date passed with no resolution recorded
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 26 July 2024 Resolved
For the past four years, Coast Guard Inspectors and ABS Surveyors have informed the operators of the FISHER (under MSC and MARAD), of the need to witness operational testing of the lower vehicle/cargo decks dewatering pump and rose box system. Since the vessel's commissioning, the Coast Guard and ABS have no record of ever witnessing an operational test of the dewatering system to ensure the dewatering pumps will pump the lower car/cargo decks in a real downflooding situation. ABS and the Coast Guard brought this to the attention of the operators, so this could be scheduled at the next drydock. Currently the FISHER is in drydock at Vigor Shipayard. However, a test of the dewatering system is not in the vessel's yard package. During the ISM Audit completed on 24 July 2024, a non-conformity (ABS finding no. 1386.0) was issued. The vessel failed to meet the requirements as a result of lack of maintenance of critical equipment, testing of the pumps, no critical spare parts for the pumps, and a lack of operational testing of these pumps. ABS Audit report attached. You are required to provide a plan for conducting a "fully functional test" of the vessels dewatering system (including suction and discharge using the vessels installed dewatering pumps). After this plan is approved by the Coast Guard, you are required to perform an operational test of the dewatering system witnessed by ABS and the Coast Guard. *Note - This appears to be a systemic problem, as there are no Coast Guard records of any BOB HOPE class vessel performing a fully functional dewatering test for ABS or the Coast Guard. If you disagree with this decision you may ask for reconsideration, or appeal this decision in accordance with 46 CFR 1.03-20.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2024
Resolved 5 June 2025
Resolution: Issued new CG-835 after discussions with MARAD.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 9 August 2022 Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements, which may be established by the Company. In meeting these requirements the Company should ensure that: appropriate corrective action is taken; and records of these activities are maintained. Evidence: The vessels Computerized Maintenance Management System has 100+ repair items identified by the crew or through required Preventative Maintenance and/or Condition Monitoring Inspections that remain open dating back as far as November 2018. It was noted that a portion of these repair items have been repaired but not closed out in the computerized maintenance system. The remaining aging items have not been repair by the company or the crew. Nature: Computerized Maintenance Management System was not updated upon completion of repair items or repair items were never addressed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 November 2022
Resolved 14 September 2022
Resolution: The operator will change before the due date of the corrective action plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 November 2021 Resolved
The inspection shall be such as to insure that the vessel, as regards…to lifesaving appliances & fire-detecting and extinguishing equipment… is in satisfactory condition and fit for the service for which it is intended. Due to a reduced crew compliment Firefighting Drills and Abandon Ship drill were not assessed. Prior to getting underway the vessel is required to conduct Drills to the satisfaction of an attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2023
Resolution: Vessel completed drills at periodic inspection NOV2022. Inspector forgot to clear def.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 22 November 2021 Resolved
Each vessel must have an illuminated repeater for the gyrocompass required under paragraph (b) that is at the main steering stand. The centerline gyrocompass repeater failed to operate as designed. Until the Vessel proves proper operation to the satisfaction of an attending Marine Inspector, vessel is limited to daylight hours only and a minimum of two mile visibility during transit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2021
Resolved 13 January 2022
Resolution: Vessel is ACP. ABS attended and witnessed proper operation of Gyro Repeater and submitted statement to USCG attesting as such. Def Cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 August 2021 Resolved
Provide Class Report/approved repair plan for the following items: EOS Clutch control for main engines, EOS control for Ballast water system, proper operation of analog gauges at MCC and proper operation of Bridge Throttles control positions indicators at all operating stations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2021
Resolved 19 September 2022
Resolution: Received ABS report attesting to ABS attendance, testing and proper operation. ABS report 5298651 uploaded to vessel documents.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 5 November 2020 Resolved
Fire-fighter's outfits shall consist of an axe with a handle provided with high-voltage insulation. Fire-fighter's outfits on the vessel did not have personal fire axes
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2020
Resolved 4 December 2020
Resolution: ABS verified axe onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2020 Resolved
Each generator arranged for parallel operation must have reverse-power or reverse-current trips. While testing the #3 generator (parraleled to #4 generator), the #3 generator did not trip in accordance with testing procedures. Approved testing procedures also did not provide step by step instruction sfor carrying out testing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 4 December 2020
Resolution: ABS verified parallel shutdown.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2020 Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maxiumum rated speed by more than 15 percent. While testing the overspeed protection on the #3 generator, the indication panel would indicate an overspeed condition but would not trip off the generator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 19 May 2021
Resolution: The No. 3 SSDG's overspeed device was tested satisfactorily by the attending ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 August 2019 Resolved
Prove the proper operation of the vent fire damper located in the E-Gen space and the bow thruster space. Both are CO2 protected spaces.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 17 September 2019
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 21 August 2019 Resolved
Prove proper operation of the fire door 5-17-2. Door does not auto close
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 17 September 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 21 August 2019 Resolved
Prove the integrity of the heavily scaled deck in the F3 cargo hold under the vent damper 7-63-6.
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 19 May 2021
Resolution: Guaging report was submitted by National Marine Services at the completion of the dry-dock avialability period at Alabama Shipyard in April of 2020. Guaging report was submitted to ABS for their survey report.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 August 2019 Resolved
Provide current international certificates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 17 September 2019
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 15 July 2019 Resolved
The company should identify potential emergency shipboard situations and establish procedures to respond to them. During the fire drill the master did not follow emergency shipboard procedures nor produce them upon request. The Vessel’s SMS stated to use the fixed CO2 system as soon as possible, however the crew intended to fight the fire manually. No checklists or plans for emergency response could be located. Provide emergency shipboard procedures for emergency response.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 3 February 2020
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 14 August 2018 Resolved
Repair the starboard bridge wing EOT. Vessel must provide an additional crew member to relay information from the main station to the starbaord bridge wing.
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 15 July 2019
Resolution: Repaired EOT
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 14 August 2018 Resolved
Provide an operable speed and distance measuring device. The installed GPS devices must remain operational.
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 19 May 2021
Resolution: GPS was verified to have been operationally tested by the attending ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 August 2018 Resolved
Replace the non-metallic flexible hose being subject to torsional deflection on the No.2A MDE's fuel system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2018
Resolved 15 July 2019
Resolution: Replaced hose
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 14 August 2018 Resolved
Repair the No.2 life boat in way of inoperative kill switch and search light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2018
Resolved 15 July 2019
Resolution: Repaired
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 November 2017 Resolved
Replace the broken light float on the ring buoy that is farthest aft on the stern starboard side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 November 2017
Resolved 28 November 2017
Resolution: Replaced ring buoy light holder with new one that was not broken.
Lifesaving › Inflatable Liferafts › Float Free
Issued 21 November 2017 Resolved
Attach the painter to the weak link for the most aft Life Raft on the starboard side. Painter was not attached to the weak link and would not float free if needed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 November 2017
Resolved 28 November 2017
Resolution: LR painter was attached to the weaklink and set up for float free arrangement.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 November 2017 Resolved
Replace fuse or filament on the navigation stern light, ensure it does not alarm when on the Primary source
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2017
Resolved 28 November 2017
Resolution: Fuse was replaced for the stern light nav light on the primary source.
Fire Fighting › Fixed Deck Foam System › Valves
Issued 14 July 2017 Resolved
Provide Technicians and ABS report regarding the proper operation of the installed Fixed Foam Fire Protection Equipment. Report shall include repair of 02 isolation valves and 02 proportioner valves, operational test, and required level of AFFF in both fwd and aft AFFF supply tanks and required spare AFFF to be carried on board. 46 CFR 76
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 21 September 2017
Resolution: Attended vsl for operational test of system. Vsl provided technician report. All sat.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 12 July 2017 Resolved
Received email; USNS FISHER SVDR is inoperable. Vessel is to attain Condition of Class from ABS for inoperable SVDR.
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 5 September 2017
Resolution: Received email from [name withheld] with ABS Condition of Class and SVDR technical report.
Navigation › Piloting/Steering › Gyro Compass
Issued 14 January 2017 Resolved
Prove proper operation of gyro compass.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2017
Resolved 17 January 2017
Resolution: Repaired gyro compass.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 January 2017 Resolved
Prove proper operation of #2 compressor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2017
Resolved 17 January 2017
Resolution: Repaired compressor.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 14 January 2017 Resolved
Prove proper operation on water tight door 4-50-1.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2017
Resolved 17 January 2017
Resolution: Repaired water tight door.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 August 2016 Resolved
Vsl has limited crew due to readiness status. Conduct crew drill prior to activation.
Action required: 705 - Other - as specified
Resolved 18 April 2018
Resolution: Completed drills see activity 6274598 for details
Deck/Cargo › Mooring/Anchoring › Brake
Issued 26 February 2016 Resolved
During anchor drill stbd anchor brake failed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 24 March 2016
Resolution: ABS surveyor witnessed repair and proper operation of stbd anchor windlass.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.