MAURY USCG vessel records
← All vessels

PYRO

PYRO is a 1969 passenger vessel (uninspected). The Coast Guard has recorded 6 inspections since 2016, most recently in February 2021, along with 4 deficiencies.

Records from 2016 to 2021. Most recent: inspection, 11 February 2021.

Built
1969
Last inspected
11 February 2021
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 February 2021
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI3755
Flag
UNITED STATES
Maury page id
psix-46469

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.8 ft × 6.0 ft
Registered tonnagegross 20 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builder"BREAUX""S BAY CRAFT, INC." · LOREAUVILLE, LA, UNITED STATES · built 1969
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

11 February 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7139211
14 November 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6855755
26 September 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6814452
4 December 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6591817
7 November 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6301460
29 August 2016 Deficiency Check · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5980894

Deficiency record · 4

Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 29 August 2016 Resolved
Portable BII Fire Extinguisher was not services since 2014. Replaced with new BII to satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 29 August 2016
Resolution: Replaced with new BII to satisfaction of attending Marine Inspector.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 29 August 2016 Resolved
Return fuel line damaged. Replaced fuel line on the spot to satisfaction of attending Marine Inspector.
Due 29 August 2016
Resolved 29 August 2016
Resolution: Replaced fuel line on the spot to satisfaction of attending Marine Inspector.
Engineering › Steering Gear System › Rudder Bearing
Issued 29 August 2016 Resolved
Port and Stbd rudder packing was not bolted/secured in place. Corrected on the spot to satisfaction of attending Marine Inspector.
Due 29 August 2016
Resolved 29 August 2016
Resolution: Added the missing bolts to both P/S rudder packing to satisfaction of attending Marine Inspector.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 29 August 2016 Resolved
No fixed fire fighting system on board after undergoing major conversion i.a.w. 46CFR181.400.
Action required: 705 - Other - as specified
Due 27 December 2016
Resolved 4 November 2016
Resolution: Fixed fire fighting system installed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.