MAURY USCG vessel records Sign in
← All vessels

M/V DEAN ANDREW

M/V DEAN ANDREW is a 1998 offshore supply vessel. The Coast Guard has recorded 19 inspections since 1998, most recently in April 2008, along with 12 deficiencies.

Records from 1998 to 2008. Most recent: inspection, 2 April 2008.

Built
1998
Last inspected
2 April 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9184108 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB7447
464765
Flag
UNITED STATES
338886000 (licence lapsed)
Maury page id
psix-464765

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (1998–2008)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it443 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
551 - Dead Weight, Ton
132 - Convention (Subpart B), Net Ton
50 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB7447MMSI 338886000 · cancelled · compulsorily equipped · granted 23 April 2004, cancelled 13 August 2008
WCY2231MMSI 338886000 · cancelled · compulsorily equipped · granted 12 March 1998, cancelled 3 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 19

2 April 2008 Permit to Proceed · Administrative Inspection · Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3175987
2 April 2007 Ballast Water Examination · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2898225
11 October 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2798292
11 August 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2798210
26 January 2006 Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2572528
23 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571373
4 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303575
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290095
28 January 2005 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2282237
28 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2230346
15 July 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2134354
10 February 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2003652
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971950
5 February 2003 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1740083
23 May 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1620382
9 March 2001 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370027
24 February 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468557
1 March 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473614
27 February 1998 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification · Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394934

Deficiency record · 12

Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 2 April 2007 Resolved
Emergency escape from berting room blocked, on both sides.
Condition: Improper/Lack of Maintenance
Due 2 April 2007
Resolved 2 April 2007
Resolution: Removed all items blocking emergency escape.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 January 2005 Resolved
Service oily water seperator and provide proof of operation.
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 1 February 2005
Engineering › Reduction Gearing/Clutches
Issued 10 February 2004 Resolved
Renew oil cooler on port main engine reduction gear. LEGACY COMPONENT DESC: Oil cooler
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2004
Resolved 10 February 2004
Electrical › Electric Supply System (service)
Issued 10 February 2004 Resolved
Provide cap for battery in engine room. LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2004
Resolved 10 February 2004
Operations/Management › Lifesaving
Issued 5 February 2003 Resolved
Provide a Life Saving Signals & Helicopter Recovery Placard. LEGACY COMPONENT DESC: Life Saving Signals & Helcopter Recovery Placard
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 25 March 2003
Lifesaving › Line-Throwing Appliances
Issued 5 February 2003 Resolved
Provide a line throwing appliance in accordance with 46 CFR 133.170.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2003
Resolved 25 March 2003
Electrical › Electrical Distribution System (service)
Issued 5 February 2003 Resolved
Repair lights on switchboard and provide cover for blank breaker. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 25 March 2003
Communications › Internal Communications System
Issued 5 February 2003 Resolved
Repair sound powered phone light in the engine room sa as to operate under emergency power. LEGACY COMPONENT DESC: Sound-powered Telephone
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2003
Resolved 25 March 2003
Engineering › Bilge Water Management System
Issued 5 February 2003 Resolved
Repair the OWS. LEGACY COMPONENT DESC: Oily Water Seperator
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 25 March 2003
Engineering › Fuel Oil Service System › Gauge
Issued 23 May 2002 Resolved
Fuel tank sight glass tubs not heat resistant.
Due 23 May 2002
Resolved 23 May 2002
Resolution: Installed heat resistant sight glass tubs.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 May 2002 Resolved
Unable to shutdown stbd engine from pilot house. LEGACY COMPONENT DESC: Engine Shutdowns
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2002
Resolved 23 May 2002
Stability › Watertight Integrity
Issued 23 May 2002 Resolved
Watertight doors not properly marked. LEGACY COMPONENT DESC: Door Markings
Due 23 May 2002
Resolved 23 May 2002
Resolution: Provided proper marking.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.