Records from 2016 to 2026. Most recent: inspection, 7 May 2026.
Inspection history · 21
7 May 2026
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8368563
12 February 2026
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8309903
9 April 2025
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8108895
19 February 2025
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8081318
4 February 2025
Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8074644
30 April 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7903969
22 February 2024
Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7868742
17 May 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7690604
8 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7648557
17 October 2022
Plan Review "T" Boat · Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7578817
2 March 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7404711
25 September 2021
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7320060
12 February 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7140025
2 June 2020
Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 6967510
27 February 2020
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6916673
27 February 2019
Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6633696
20 February 2019
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6630722
28 April 2018
Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 6404242
25 January 2018
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6344078
27 February 2017
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6095830
1 March 2016
DAPI Audit · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5824728
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 February 2026
Resolved
All vessels shall be provided with bilge pumps in accordance with table 182.25-10(a)
Inspector witnessed bilge pump would not take suction from the port forward void.
46 CFR 182.25-10(a)
Action 60C
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 24 February 2026
Resolved 27 February 2026
Resolution: Witnessed satisfactory operation of bilge pumps taking suction from both port and starboard forepeak voids.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 February 2026
Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system.
MI's arrived and found one detector in the pilothouse missing and a new one ready for replacement but not connected.
46 CFR 181.450(a)(2)
Action 701c
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2026
Resolved 27 February 2026
Resolution: Witnessed satisfactory operation of interconnected fire detection system.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 February 2026
Resolved
Each vessel certificated to operate on an oceans route in warm water must either:(1) Be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 67% of the total number of persons permitted on board; or(2) Be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. MI's observed one hydrostatic release on the 6 man liferaft and one hydrostatic release on the starboard inflatable bouyant apparatus expired. The 6 person liferaft was not properly secured to the cradle. The starboard 15 person buoyant apparatus was not serviceable due to wasted straps and a cracked floating light. Bring all lifesaving equipment into compliance with requirements of Subchapter T. Vessel is restricted to carriage of no more than 67 passengers until deficiency is rectified.
46 CFR 180.202(b)
Action 701c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2026
Resolved 7 May 2026
Resolution: Witnessed satisfactory installation of new 10 person liferaft.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 February 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2026
Resolved 27 February 2026
Resolution: Vessel owner showed evidence of a new FCC station authorization issued and being mailed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 February 2026
Resolved
Suitable covers, guards or rails shall be installed in way of all exposed and hazardous places such as gears, machinery etc.
MI observed missing guard on the generator pulleys. Install guards to the satisfaction of USCG MI.
46 CFR 177.35-15(a)
16c
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 27 February 2026
Resolution: MI observed satisfactory guard on generator.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 February 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
Vessel could not produce a complete, unexpired, serviceable medical kit meeting requirements in 46 CFR 199.175(b)(10). Present to MI a medical kit containing all contents required to USCG MI.
46 CFR 184.710
Action 701c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2026
Resolved 27 February 2026
Resolution: Vessel owner showed proof of purchase of new medical kits and splints
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 12 February 2026
Resolved
Applicants seeking a national endorsement must either hold an unexpired medical certificate or submit a medical certificate application.
Vessel master could not produce a medical certificate. Master provide proof of valid medical certificate prior to serving as Master.
46 CFR 10.227(d)(6)
50c
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2026
Resolved 27 February 2026
Resolution: Master applied for a new medical card and is awaiting receipt. Vessel owner will emply a master with a valid medical card in the interim.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2026
Resolved
Materials used in piping system must meet the requirements of this subpart and otherwise be acceptable to the cognizant [name withheld] observed raw water leaking from the raw water discharge to the exhaust pipe in the port machinery space. Submit proposal to affect permanent repairs to the pipe to the satisfaction of USCG MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2026
Resolved 27 February 2026
Resolution: MI observed repair to pipe and proper operation
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 February 2026
Resolved
Each battery must be secured to protect against shifting with the roll and pitch of the vessel and free from water splash or spray. MI observed a battery in the port engine room sitting on the deck plates. Properly secure in approved container or remove battery from vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2026
Resolved 27 February 2026
Resolution: MI observed secured battery within a box.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2026
Resolved
Each life jacket must be approved under approval series in subparts 160.002, 160.005, 160.055, 160.115, 160.176, or 160.255 in part 160 of this chapter, or other standard specified by the Commandant. MI's observed approximately 21 life jackets not meeting approval due to either being unserviceable or not having adequate lights. Vessel is restricted to the carriage of 90 persons for this purpose until adequate, approved life jackets are provided for all 111 authorized.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2026
Resolved 27 February 2026
Resolution: MI observed replacement of old lifejackets with new ones.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 April 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. MI observed the stbd engine room fire extinguisher missing the cone on the end of the hose. Replace extinguisher with approved type 40BC.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2024
Resolved 13 May 2024
Resolution: MI attended and inspected all correct fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. MI observed no separation of the adult and child life jackets on the main deck. Separate Adult from child life jackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2024
Resolved 1 May 2024
Resolution: Vessel owner sent photograph of a physical seperation between child and adult lifejackets utilizing plywood
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2024
Resolved
Equipment mounted on a hinged door of an enclosure must be constructed or shielded so that a person will not accidentally contact energized parts of the door mounted equipment when the door is open and the circuit energized. MI observed open front ends on the stbd engine room distribution panel. Ensure the front of the panel is shielded so no personnel can contact engergized equipment.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 30 May 2024
Resolved 1 May 2024
Resolution: Vessel owner submitted photo of rectification by installation of plexiglass over the open areas of the breaker panel
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 30 April 2024
Resolved
The strength of the float-free link under paragraph (b)(2) of this section and the strength of the painter under § 180.175(f)(3)(ii) must be determined by the combined capacity of the group of life floats and buoyant apparatus. MI observed the float free links on both lifefloats rated for a breaking strength exceeding the weight of the installed lifefloats. Vessel corrected on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 May 2024
Resolved 30 April 2024
Resolution: Vessel installed new weak links rated for 12+
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 17 May 2023
Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request.
Maintenance logs for lifesaving appliances were not available for review by the attending marine inspector. Provide proof of lifesaving maintenance documentation to the satisfaction of the attending marine inspector.
CITE: 46 CFR 185.702(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 1 June 2023
Resolution: VSL rep provided proof of lifesaving maintenance documentation. Logs uploaded in docs under def tab.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 May 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
EPIRB registration is expired. Provide proof of valid registration to the satisfaction of OCMI.
46 CFR 180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 19 May 2023
Resolution: EPIRB registration recieved. Registration uploaded under docs in def.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2023
Resolved
Each buoyant apparatus must have Type II retro reflective material meeting subpart 164.018 of this chapter on each side and end.
The starboard side life float requires new retro reflective tape.
46 CFR 160.010-4(p)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2023
Resolution: Crew addressed the retro reflective tape once it was recognized. MIs re-inspected life floats before departure.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 May 2023
Resolved
Each survival craft required on a vessel by this part must meet one of the following: For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Life float is missing the approval plate and could not be verified to be approved. Life float was replaced by an IBA.
CITE: 46 CFR 180.200(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2023
Resolution: Crew removed life float and replaced with a IBA.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 May 2023
Resolved
Each buoyant apparatus must be fitted with a lifeline, pendants, a painter, and a light.
Top Center life float straps securing center webbing are deteriorated and not serviceable.
CITE: 46 CFR 180.175(e)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2023
Resolution: Crew removed unserviceable life float and replaced with an IBA.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2023
Resolved
Each life jacket must be marked with Type I retro reflective material approved in 46 CFR 164.018.
06 life jackets require new retro reflective tape.
CITE: 46 CFR 185.604(h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2023
Resolution: 06 life jackets were removed from service on the vessel by crew. 06 new life jackets were installed on vessel. Inspected by attending MIs.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 March 2022
Resolved
Vessel had groups of life floats tethered to single weak link. Weak link installed was designed to break free with life raft capacity less than capacity of group.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2022
Resolved 7 March 2022
Resolution: Weak link with capacity of 21 or more persons installed on all three life float areas.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 February 2021
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. USCG Marine Inspectors found three (3) out of nine (9) of the life floats onboard had broken and missing straps, deteriorated lines, and missing data plates.
Remove and replace the life floats or effect appropriate repairs to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 15 March 2021
Resolved 28 May 2021
Resolution: Vessel replaced deteriorating line and straps, and replaced one life float that was missing the data plate.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 27 February 2020
Resolved
Each ship transporting more than 6 passengers for hire equipped with a radiotelephone station must carry a radio operator. At time of inspection, vessel master did not have a valid FCC Marine Radio Operator Permit. Provide FCC Marine Radio Operator Permit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2020
Resolved 4 March 2020
Resolution: Vessel submitted copy of Captains [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2020
Resolved
If a garden hose is used, it shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent metal. Vessel did not have nozzles on either of its firehoses. Provide satisfactory nozzles for fire hoses.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2020
Resolved 4 March 2020
Resolution: Vessel submitted pictures of new hoses.
Fire Fighting › Fire Hoses › Material
Issued 1 March 2016
Resolved
Fire hoses onboard were not of a good commercial grade and lacked nozzles.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 15 March 2016
Resolution: O/O installed commercial grade hoses with nozzles.
Fire Fighting › Fire Pumps › Arrangement
Issued 1 March 2016
Resolved
Portable hand fire pump does not have suction and discharge hoses of adequate length.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 15 March 2016
Resolution: O/O added discharge hoses of adequate length.