Records from 2001 to 2021. Most recent: operational control imposed, 4 November 2021.
Inspection history · 24
4 November 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7345571
27 September 2021
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7327657
16 September 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7082913
8 September 2020
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7053437
23 October 2019
COI Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6839595
27 August 2019
Deficiency Check · Administrative Inspection · Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6755074
21 May 2019
Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6681000
12 February 2019
Administrative Inspection · Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6621186
23 October 2018
COI Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6566063
25 July 2018
Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6491127
14 July 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6491371
25 May 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6429305
10 April 2018
Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6413913
23 January 2018
Re-Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6345390
27 October 2017
COI Inspection · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6295426
15 August 2017
Re-Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6240627
16 May 2017
Deficiency Check · Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6147766
25 January 2017
Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6077211
27 October 2016
Deficiency Check · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6028810
26 July 2016
MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5954392
10 May 2016
Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5875176
24 March 2016
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5839992
3 March 2016
DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5826438
25 January 2016
Administrative Inspection · Re-Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5802689
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2019
Resolved
The ring life buoy (RLB) on Deck 2 centerline aft, is missing the plug. Repair or replace RLB.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2019
Resolution: Life ring was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 August 2019
Resolved
At each inspection for certification and periodic inspection the marine inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as he feels necessary to check safe operation. # 6 Main Diesel generator is incapable of starting due to faulty air-starter. Repair engine so required tests can be conducted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2019
Resolved 9 September 2019
Resolution: Received email stating starter has been installed and tested satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2019
Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Crew had Shore Power switchboard propped open w/ fan blowing on breakers.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 27 August 2019
Resolution: Crew removed fan and closed switchboard front. CHENG indicated he didn't believe the fan was actually needed. MI will monitor during next quarterly inspection.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 August 2019
Resolved
FSD 4-01B did not close when test button was activated, tested buttons on both sides of door. Repair door closure and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2019
Resolved 28 August 2019
Resolution: Captain emailed video showing door closing properly when test button depressed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 August 2019
Resolved
Portable fire extinguisher in aft galley on 4th deck port side next to exit door, gage is showing overcharge and tamper seal is missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2019
Resolved 3 September 2019
Resolution: Received invoice showing purchase of new extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2019
Resolved
Fire station # 62 properly stow fire hose in station cabinet.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2019
Resolution: Corrected during course of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 August 2019
Resolved
Lifebuoy on 4th deck forward port side is missing plug, repair or replace missing plug.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2019
Resolution: Lifebuoy replaced.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 May 2018
Resolved
One detector on the 2nd deck, aft, had been replaced and was not communicating with the detection panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2018
Resolved 31 May 2018
Resolution: Ships crew & third party discovered one leg of ups over loaded and sensor was addressed wrong, all corrected and tested satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 August 2017
Resolved
Provide copy of last annual servicing report.
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 15 August 2017
Resolution: Received email with annual servicing report.
Communications › Public Address System › Loudspeaker
Issued 16 May 2017
Resolved
All speakers on 2nd deck aft were inoperable.
Action required: 705 - Other - as specified
Resolved 16 May 2017
Resolution: Replaced corroded wires and speaker in the circuit which corrected the deficiency.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 May 2017
Resolved
2 emergency lights were inoperable during testing.
Action required: 705 - Other - as specified
Resolved 16 May 2017
Resolution: Bulbs were replaced prior to end of inspection.
Engineering › Electric Propulsion System › Indicator Circuitry
Issued 16 May 2017
Resolved
2 indicator bulbs (#1 "SCR Ready" and "Power Limit") in the aft pilot house are inoperable.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 August 2017
Resolution: Indicators repaired and tested satisfactory.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 May 2017
Resolved
The mounts for the emergency battery bank, for pilot house equipment, were severely corroded.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 August 2017
Resolution: Corrosion cleaned and terminals treated.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 January 2017
Resolved
Replace expired eye wash bottles in employee galley.
Due 2 February 2017
Resolved 22 February 2017
Resolution: Eye wash bottles replaced.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 27 October 2016
Resolved
Clean food, grease, etc. in 4th deck aft galley under all counters.
Due 28 October 2016
Resolved 28 October 2016
Resolution: Captain ensured area cleaned.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 October 2016
Resolved
Repair F.S.D. 4-01A and prove proper operation.
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: Vessel engineering crew adjusted and tested door satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 27 October 2016
Resolved
Remove broken glass and bottle caps from deck behind 3rd deck forward bar .
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: Bar tender and bar back cleaned area.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 27 October 2016
Resolved
Remove clutter in 1st deck stair tower and properly stow.
Due 28 October 2016
Resolved 28 October 2016
Resolution: Chief engineer cleared area.
Construction/Loadline › Structures › Machinery Space Opening
Issued 27 October 2016
Resolved
Provide repair proposal to repair or replace the forward port z-drive hatch to original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 15 August 2017
Resolution: New hatches installed.
Engineering › Non-conventional Propulsion/Steering › Well-flange (z-drive)
Issued 27 October 2016
Resolved
Replace corroded fasteners on forward port z-drive well flange.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 25 January 2017
Resolution: New stainless steel fasteners installed.
Engineering › Compressed Air System (start air) › Valve
Issued 26 July 2016
Resolved
Repair or replace and prove proper operation of relief valve on air receiver next to engine room stairs.
Due 26 August 2016
Resolved 27 October 2016
Resolution: Chief engineer replaced and tested relief valve satisfactory.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 26 July 2016
Resolved
Repair and prove proper operation of FSD3 2-02B and FSD3 2-02C
Due 26 August 2016
Resolved 27 October 2016
Resolution: Door adjusted and tested satisfactory.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 3 March 2016
Resolved
A number of employees were tested with Non-Dot tests. All new employees who were not given a DOT pre-employment test shall be re-tested using a DOT pre-employment test IAW with 46 CFR 16.210, when completing the Federal Custody Control Form the other block should be checked with a note stating the orginial test was not a DOT test.
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 30 March 2016
Resolution: All pre-employment tests that were non-dot have been redone with a DOT test.
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (air motor)
Issued 25 January 2016
Resolved
Repair/ replace air starter on # 6 propulsion generator diesel engine and prove proper operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 December 2016
Resolved 24 March 2016
Resolution: Starter repaired
Accommodation/Occupational Safety › Ventilation › General
Issued 25 January 2016
Resolved
Repair and prove proper operation of ventilation dampner on hold deck in light locker.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2016
Resolved 26 January 2016
Resolution: Corrected during course of inspection.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 25 January 2016
Resolved
The following fire screen doors did not operate as intended. Preventative maint required. 3-02A (fwd door not closing), 3-02B (fwd door not closing) and 3-02C not fully closing due to stiff brush edging.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 24 March 2016
Resolution: All doors repaired & tested sat.