Records from 2013 to 2026. Most recent: inspection, 10 March 2026.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 March 2026
No resolution recorded
Vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection as specified in paragraph (b)(1) of this section.(1) Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has missed the window to conduct an annual inspection. Vessel is restricted from operating until completion of an annual inspection.
46 CFR 165.500(b)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed diesel fuel in the engine room bilge, vessel reported that the fuel system had a leak. Leak needs to be identified and repaired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Leaks were repaired. No visisble fuel leaks found.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 October 2024
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. MI observed starboard side fuel vent pipe missing flame screen. Put flame screen in vent line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Installed flame screen on fuel vent.
10 - Safety of Navigation › N/A - No Subsystem › GNSS receiver/terrestrial radio navigation system
Issued 24 October 2024
Resolved
A vessel on an oceans route must be equipped with an electronic position fixing device, capable of providing accurate fixes for the area in which the vessel operates, to the satisfaction of the cognizant [name withheld] observed vessel GPS inoperative. Vessel must obtain new GPS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Vessel installed new GPS unit.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 24 October 2024
Resolved
Vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. MI observed VHF and GPS interface not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Vessels radios had GPS interfaced into them.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 October 2024
Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarm in all areas required by regulation to be protected by the interconnected detection and alarm system. MI witnessed interconnected detection system incapable of being tested or verified operational. Obtain equipment required per manufacturer’s instructions to test smoke detectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Test of interconnected smoke detect. system was SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 October 2024
Resolved
On a vessel of at least 26’ in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in required spaces. MI witnessed bilge level alarm float switches incapable of being tested. Pump bilges and test bilge level alarm float switches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Float switches were tested and found SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 October 2024
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment... under all practicable conditions. MI witnessed bilge pump in crew space inoperable. Repair bilge suction for the crew space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Conducted test of bilge suction in crew space, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 October 2024
Resolved
Except as otherwise provided, all engines must be water cooled and meet the requirements: The engine head,block, and exhaust manifold must be water-jacketed and cooled by water from a pump that operates whenever the engine is operating. MI observed coolant leak and missing hose on generator and port engine. Repair these systems as designed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Vessel replaced hoses and no visible leaks were found.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 24 October 2024
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. MI observed no pre-employment testing conducted for vessel Master and Deckhand.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Vessel provided valid drug consortium certificate indicting crew members enrollment.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 24 October 2024
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant [name withheld] did not observe anchor line on vessel; owner/operator to obtain and install an anchor line of sufficient length for vessel’s route and service.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Vessel had new anchor with chain and line installed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2024
Resolved
A vessel must carry one floating waterlight attached to ring buoy. MI observed floating light on starboard side attached to ring buoy that was compromised with water ingress, missing an “o” ring. Replace the light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Vessel replaced waterlight on lifebouy.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 October 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. MI observed vessel did not have up-to-date charts. Vessel must update charts used onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Vessel purchased new charts.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 October 2024
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. MI observed the port main diesel engine battery bank had loose and corroded wire connections at the battery. Starboard main diesel engine starter had a loose battery cable connection. Clean battery connections and tighten all connections.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Inspected loose battery cables and cable connections to the engine room batteries, SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2024
Resolved
The owner or managing operator shall make sure that maintenance is carried out in accordance with the instructions. MI observed vessel not conducting maintenance on required gear and systems. Vessel must ensure all maintenance is completed and logs are up-to-date prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Vessel has log book filled out for the current month and plans to continue to utilize maintenance log book.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 24 October 2024
Resolved
The name of the vessel must be marked on’ some clearly visible exterior part of the port and starboard bow and the stern of the vessel. MI observed vessel name not marked on port and starboard. Vessel must clearly mark.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2024
Resolution: Vessel placed name on both P&S sides of the vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 October 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. MI observed vessel did not have portable light located near access to the propulsion machinery space, and the portable light at the operating station not operable. Place an operable light at each location.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2024
Resolution: Vessel installed portable lights near the engine room and operating station.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 October 2024
Resolved
All electrical equipment and circuits must be clearly marked and identified. MI observed that the circuit breakers were not labeled in the engine room forward circuit breaker panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2024
Resolution: Vessel labeled all breakers.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 October 2024
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. MI observed unsupported wires behind the generator in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2024
Resolution: Vessel installed proper wire harnesses on cables behind generator.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 October 2024
Resolved
Vessel control systems and other miscellaneous systems and equipment required by this part must be suitable for the purposes intended. MI observed secondary steering station facing aft was inoperable. Develop and propose a
plan to repair or remove this steering system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2024
Resolution: Witnesses a satisfactory test of the steering system from aft operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 November 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine Inspector observed two open slots in Engine Room breaker panel. Fill/cover. Marine Inspector observed two dead end wires on front of generator. Remove/repair. Marine Inspector observed wires pulled from stuffing tube on engine room battery charger. Repair. Marine Inspector observed dead end wire in cable to battery charger. Repair/replace.
46CFR176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 12 December 2023
Resolution: Vessel representative fixed stuffing tube, dead ended wires, and installed blanks on the engine room breaker panel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 November 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine Inspector observed damaged framing in engine room port aft above battery charger. Repair during/by next dry dock.
46CFR176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2025
Resolved 10 March 2026
Resolution: Framing renewed, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 November 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel failed to receive annual inspection within inspection window. Vessel is prohibited from operating until annual inspection is complete.
46 CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 November 2023
Resolution: Vessel scheduled and had completed annual inspection with the USCG on 28NOV2023.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 September 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. 02 smoke detectors were expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2022
Resolved 17 October 2022
Resolution: photo evidence of 2 new smoke detectors installed
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 14 September 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The deck longitudinal in the lazarette from the centerline aft was found to have 04 broken welds connecting to the deck above.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2022
Resolved 17 October 2022
Resolution: provided photo evidence of repaired welds
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 14 September 2022
Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. Master was missing MMC license. Provide documentary evidence of MMC of Master or documentary evidence of MMC of another Master before getting underway.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2022
Resolved 12 July 2023
Resolution: provided proof of active masters MMC
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 September 2022
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry – Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; Six hand orange smoke distress signals approved in accordance with § 160.037
specified by the Commandant. 06 orange smoke signals onboard were expired and 06 red flares expire at the end of the month. Vessel restricted to Lakes, Bays, and sounds route until documentary evidence is provided to Marine Inspector for the replacement of all 12 distress signals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 17 October 2022
Resolution: provided photo evidence of new flares
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 September 2022
Resolved
Each life jacket carried on a vessel on oceans route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. 04 life jacket lights were expired. Vessel is restricted to 36 passengers on oceans routes until lights are fixed/replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 17 October 2022
Resolution: provided photo evidence of new lights on lifejackets
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 September 2022
Resolved
Portable extinguishers must be inspected monthly as required by NFPA 10 conducted by the owner, operator, person-in-charge, or a designated member of the crew.
Monthly inspections of portable fire extinguishers were not conducted. Provide documentary evidence of updated log inspections to Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 17 October 2022
Resolution: provided photo evidence of updated log
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 September 2022
Resolved
The master of the vessel shall ensure that: Each EPIRB, other than an EPIRB in an inflatable life raft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Monthly tests of EPIRB were not conducted or logged. Provide documentary evidence of updated log inspections to Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 17 October 2022
Resolution: provided photo evidence of updated log
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First kit onboard had expired contents. Replace aspirin and eye wash in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 17 October 2022
Resolution: updated photo evidence of new aspirin and eye wash
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel was
missing second operable portable battery light at access to the machinery space. Place second portable battery light onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 17 October 2022
Resolution: provided photo evidence of new portable light
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 September 2022
Resolved
Abandon ship and man overboard drills and training, firefighting drills and training, and inspection and maintenance of survival craft shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel log was missing abandon ship and man overboard drills and training, firefighting drills and training, and inspection and maintenance of survival craft since summer of 2021. Provide documentary evidence of updated logs to the Marine Inspector.
46 CFR 185.520(f)
46 CFR 185.524(d)
46 CFR 185.702(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 17 October 2022
Resolution: provided photo eveidence of updated logs
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 September 2022
Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Marking for remote fuel shutoff station was deteriorated and no longer legible. Replace fuel shutoff label on superstructure.
46 CFR 185.30-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 17 October 2022
Resolution: provided photo evidence of new fuel shutoff label
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 September 2022
Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters' Laboratories, Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 595, or shall bear the proper Underwriters' Laboratories, Inc. "Marine Type" label, or shall be constructed in accordance with the requirements of other recognized testing laboratories. 02 lights in lazarette and 01 light on starboard beam were not in compliance with UL standards. Fix/replace lights and/or fixtures.
46CFR 183.10-25(l)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 17 October 2022
Resolution: provided photo evidence of fixed light fixtures
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 July 2021
Resolved
Vessels shall have a high water alarm, visual and audible, at the operating station. Forepeak high water alarm was inoperable. Fix alarm to satisfaction of MI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 July 2021
Resolved 8 July 2021
Resolution: Crew re-wired and replaced float switch, SAT op test.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 July 2021
Resolved
Vessels on oceans routes must have an EPIRB stowed in a manner to float free if the vessel sinks. Vessel's hyrdostatic release unit (HRU) was expired, replace HRU.
Action required: 10 - Deficiency Rectified
Due 14 July 2021
Resolved 8 July 2021
Resolution: Crew replaced on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2021
Resolved
All navigation lights shall be operative when vessel is operating at night or in reduced visibility. Starboard nav light was inop, replace to satisfaction of MI.
Action required: 10 - Deficiency Rectified
Due 14 July 2021
Resolved 8 July 2021
Resolution: Crew replaced bulb and MIs witnessed SAT op test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 June 2021
Resolved
REMOVE EXCESS WATER IN A/C COMPARTMENT.
Due 7 July 2021
Resolved 8 July 2021
Resolution: Water removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2019
Resolved
Fuel leak on stbd engine in vicinity of fuel pump. Repair and ensure no leakage.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2019
Resolution: Fuel leaks fixed. New fittings installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2019
Resolved
Raw water leak on port engine exhaust cooling piping. Repair and ensure no leakage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2019
Resolved 22 November 2019
Resolution: Pump gasket replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2019
Resolved
No ventilation for batteries under operating console. Provide ventilation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2019
Resolved 12 December 2019
Resolution: Installed ventilation cover on operating console door face.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2019
Resolved
Electrical panels not properly labeled. Properly label panels.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2019
Resolved 12 December 2019
Resolution: Electrical panels were properly labled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2019
Resolved
Light in Lazarette missing protective guard and cover. Replace guard and cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2019
Resolved 12 December 2019
Resolution: Installed protective light guard and cover.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 21 November 2019
Resolved
All emergency escapes must be properly labeled on both sides. Properly label.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2019
Resolved 12 December 2019
Resolution: Emergency escapes properly labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 November 2019
Resolved
Emergency escape from galley inoperable. Repair and make operable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2019
Resolved 12 December 2019
Resolution: Emergency escape was repaired and demonstrated to be operable.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 November 2019
Resolved
Navigation charts not up to date. Update navigation charts.
Action required: 10 - Deficiency Rectified
Resolved 21 November 2019
Resolution: Purchased new navigation charts for area of operation.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 21 November 2019
Resolved
Protective cover on life floats obstructs embarkation. Remove or stow in a manner that will not interfere with embarkation.
Action required: 10 - Deficiency Rectified
Resolved 21 November 2019
Resolution: Removed protective cover.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 21 November 2019
Resolved
Removable deck rails not mounted on aft main deck. Mount rails.
Action required: 10 - Deficiency Rectified
Resolved 21 November 2019
Resolution: Reinstalled deck rails
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 August 2018
Resolved
Starboard steering rudder partially seized, incapable of full range. Repair to the satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2018
Resolution: Rudder Stock was heated up and freed up, bolts for packing gland were replaced. Verified full range of motion of complete steering system. All Sat vessel cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 August 2018
Resolved
Found section of clear plastic tubing approximately 4 inches in length on discharge side of bilge manifold. Remove and replace with suitable material.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2018
Resolved 20 August 2018
Resolution: plastic tubing was removed and replased with metal piping. Tested system to verify full operation. Suction from FWD tank void overboard. Test Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2018
Resolved
Engine Room bilge pump inoperable. Reapir and prove proper operation of bilge pumping system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2018
Operations/Management › Equipment Service/Testing › EPIRB
Issued 27 June 2017
Resolved
EPIRB battery is expired, replace or purchase new IAW 46 CFR 185.728
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 June 2017
Resolution: Owner purchased new Cat 1 EPIRB and registered.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 June 2017
Resolved
Replace life float water light battery with approved IAW 46 CFR 180.202
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: New batteries were installed
Lifesaving › Lifefloat › Markings
Issued 27 June 2017
Resolved
Replace/renew life float (port), and life ring’s SOLAS tape IAW 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: New SOLAS A tape was installed
Lifesaving › Lifefloat › Float Free
Issued 27 June 2017
Resolved
Make life float teather long enough to launch one at a time IAW 46 CFR 180.202
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Tether of adequate length was installed
Lifesaving › Lifefloat › Paddle
Issued 27 June 2017
Resolved
Label life float paddles with vsl name IAW 46 CFR 158.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Paddles were marked with vessel name
Fire Fighting › Means of Escape › Blocked
Issued 27 June 2017
Resolved
Adjust the forward emergency escape hatch to operate from both inside and outside IAW 46 CFR 179.330
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Hatch was adjusted and can be properly secured
Accommodation/Occupational Safety › Potable Water System › General
Issued 27 June 2017
Resolved
Potable water head tank is leaking; make operable IAW 46 CFR 177.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Tank is no longer leaking and was properly repaired
Communications › Alarms/Indicators › High Water Alarm
Issued 27 June 2017
Resolved
Mount high level alarm in the engine room IAW 46 CFR 182.520
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: High level alarm was properly mounted and secured
Engineering › Fuel Oil Service System › Hose
Issued 27 June 2017
Resolved
Replace fuel hose and double clamp in lazzerette IAW 46 CFR 182.710
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Double clamps were properly installed to secure new hose
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 27 June 2017
Resolved
Fix main diesel engine exhaust leaks in the lazzerette IAW 46 CFR 182.430
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Leaks were corrected and proper repairs were effected
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 27 June 2017
Resolved
Apply lagging to generator exhaust in the lazzerette IAW 46 CFR 182.430
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Lagging was replaced
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 27 June 2017
Resolved
Make smoke detectors in accommodation space operable IAW 46 CFR 181.400
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 June 2017
Resolved 25 July 2017
Resolution: Smoke detectors were tested and found operable
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 June 2017
Resolved
Post emergency instructions at operating station IAW 46 CFR 185.520
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Emergency instructions were posted
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 June 2017
Resolved
Provide alcohol strips IAW 46 CFR 16.202
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Alcohol strips were provided on board
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 June 2017
Resolved
Provide current coast pilot, tide and current table, and log radio checks IAW 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Current publications were found on board
Construction/Loadline › Hull › Bottom Plating
Issued 9 May 2017
Resolved
During vessels hull exam, some pitting was found located in bilge area just fwd of center fuel tank. Area is approximately 3'x 3' and has 04 pits that are over 20%. Vessel will operate till October 31, 2017 and will then be drydocked for repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 2 February 2018
Resolution: Witnessed a sastifactory Soap and Blow test