Inspection history · 20
10 September 2025
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8230986
10 September 2025
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8230994
15 January 2025
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8064398
3 January 2025
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8067016
1 October 2024
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8012606
20 November 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7802138
22 November 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7598946
19 November 2022
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7609248
11 January 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7378527
8 June 2021
Deadweight Survey · Construction Oversight · Administrative Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7219609
14 December 2020
Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7111985
13 October 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7076123
23 July 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7014226
26 November 2019
Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6863203
25 July 2019
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6762159
26 June 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6449055
27 February 2017
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6095743
27 February 2017
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6095901
22 September 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6007507
1 August 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5959392
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 1 October 2025
Resolved
Each unpressurized fuel tank must be fitted with a vent pipe connected to the highest point of the tank. MI observed threads of vent connection were not the proper size and vent was not properly attached.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2025
Resolved 2 October 2025
Resolution: Vessel poc sent pictures clearing the deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 October 2025
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). MI observed vessel did not have a portable hand pump on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2025
Resolved 2 October 2025
Resolution: Vessel rep sent pictures to clear deficiency.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 October 2025
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. MI observed there were alarms for oil pressure and jacket water temp, but no readable gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2025
Resolved 3 November 2025
Resolution: Received evidence of new gauges showing oil pressure and jacket water temp.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 1 October 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. MI observed vessel did not have emergency instructions on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2025
Resolved 3 November 2025
Resolution: Received evidence of emergency instructions posted at operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 December 2024
Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter; and each ring life buoy on a vessel must: Be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. MI observed life buoy to be in state of disrepair and solas tape worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2024
Resolved 5 February 2025
Resolution: Ring buoy replaced.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 11 January 2022
Resolved
Stability letter must be posted under glass or other transparent material, at the operating station. No stability letter on board or posted. Post stability at operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 25 January 2022
Resolution: Observed mounted stability letter
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 January 2022
Resolved
Ships Station licenses will be issued for ten years. License was expired. Provide valid license. 47 CFR 80.25
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 25 January 2022
Resolution: Owner renewed license
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 January 2022
Resolved
Vessel must comply with VHF radio installation in accordance with 47 CFR 80. VHF must be registered with MMSI and GPS data.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 25 January 2022
Resolution: Owner registered VHF with MMSI
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 January 2022
Resolved
essel must carry adequate and up to date charts. Vessel charts were not updated. Provide updated charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 25 January 2022
Resolution: Owner updated charts
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 January 2022
Resolved
Each life ring must be clearly marked with the vessel's name in blocked lettering. Vessel's name is fading. Renew vessel's name on life ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 25 January 2022
Resolution: Owner clearly marked vessels name on life ring
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 January 2022
Resolved
Life jackets must be serviceable and in good repair. 17 adult and 39 child life jackets were dry rotted. Replace life jackets. Vessel currently has 42 adult and 14 child life jackets that are serviceable. Passenger count is reduced to 40 adult passenger, 2 crew and a maximum of 14 children. Total passenger count not to exceed 52.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 25 January 2022
Resolution: Owner purchased new lifejackets (both adult and child)
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 January 2022
Resolved
Inspection of each portable fire extinguisher system to check for corrosion and general condition. Both aft deck port and STBD portable fire extinguisher brackets are wasted. Replace both portable fire extinguishers brackets with approved brackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 25 January 2022
Resolution: Owner replace all brackets.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 January 2022
Resolved
Conduct monthly inspections of portable fire extinguishers. No log of monthly fire extinguisher inspections. Create monthly inspection log.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 25 January 2022
Resolution: Owner created log.
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 11 January 2022
Resolved
Vessel must comply with equipment and procedures for pollution prevention in accordance with 33 CFR 151.59. Vessel does not have a garbage placard. Post garbage placard in accordance with CFR. 46 CFR 184.702
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 25 January 2022
Resolution: Owner posted placard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 January 2022
Resolved
Fuel shutoff stations must be marked in clearly legible to indicate purpose of the valve and direction of operation. Valve labeling unreadable due to cover. Relabel shutoff valves.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 25 January 2022
Resolution: Owner installed new placards.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 November 2019
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may require the vessel to be dry docked or taken out of service to assess the extent of the damage, and to effect permanent repairs. The OCMI may also decrease the dry dock examination intervals to monitor the vessel's structural condition. Noted extensive pitting on both pontoons during examination of hull. The owner/operator shall submit a satisfactory repair proposal to the OCMI for review and approval prior to conducting permanent repair. Permanent repair of pontoons shall be conducted no later than 31OCT20.
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 14 October 2020
Resolution: Vessel must now be drydocked NLT 07FEB21.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019
Resolved
Battery at operating station not mounted. Battery must be mounted in tray constructed of material that is resistant to damage by the electrolyte.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2019
Resolution: Provided battery box at operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019
Resolved
Starboard side outboard engine showing dead end wire. Dead end wires shall be removed or end in a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2019
Resolution: Removed dead end wires.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 August 2019
Resolved
Navigation publications including CG Light List, US Coast Pilot, and Tides/Currents out of date. Vessel must carry up-to-date charts and publications.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 21 August 2019
Resolution: Vessel operator provided duplicate electronic copies.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 25 August 2016
Resolved
Water light battery worked but expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 22 September 2016
Resolution: Battery replaced with 2019 exp date and working.
Navigation › Piloting/Steering › Marine Charts
Issued 25 August 2016
Resolved
Navigation pubs not on board. Need to purchase.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 22 September 2016
Resolution: Pubs printed and or purchased all updated.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 August 2016
Resolved
Fuel shut off valves at fuel tanks were missing, install same.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 22 September 2016
Resolution: New fuel valves installed.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 25 August 2016
Resolved
Supervisory training was missing for both captains.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 22 September 2016
Resolution: Training conducted and documented.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 25 August 2016
Resolved
Emergency instructions and emergency broadcast need posted, has each just post.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 22 September 2016
Resolution: Instructions and broadcast posted.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 25 August 2016
Resolved
FCC safety cert was expired on June 2016.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 22 September 2016
Resolution: Safety cert completed and documented.