Documentation record
Registered dimensions (L × B × D)36.0 ft × 14.0 ft × 6.5 ft
Registered tonnagegross 21 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderP & S INDUSTRIES, INC · SEBRING, FL, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE TAHOE, CA
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 7 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Net Ton
21 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 8 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 8
14 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8127447
15 May 2024
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7910114
14 May 2024
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7907718
16 May 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684923
3 May 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7436256
28 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7173978
11 May 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949155
23 April 2018
Initial Certification · Administrative Inspection · Deficiency Check · COI Inspection · Plan Review "T" Boat · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6397887
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 May 2025
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight:
(3) A hatch on a vessel that operates only on protected waters. Hatches need to be made weathertight.
46 CFR 179.360(a)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 20 May 2025
Resolution: vessel acquired plugs and filled the holes found in the hatches.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2025
Resolved
In a vessel of less than 12 meters in length:
(v) A white, red, green or yellow all-round light, 2 miles. Vessel's all around light is blocked by life float.
33 CFR 83.22(c)(v)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 20 May 2025
Resolution: Vessel installed a taller pole for the all round light, all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 May 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (ii) Monthly inspections required by NFPA 10. Vessel has not been conducting monthly inspections.
46 CFR 176.810(B)(1)(ii)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 8 July 2025
Resolution: Operator emailed log of inspections (uploaded to documents).
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2024
Resolved
A power-driven vessel underway shall exhibit a masthead light forward. Vessel's masthead light is not functional.
46 CFR 83.23(a)(i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 29 July 2024
Resolution: Masthead light operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2024
Resolved
An adult lifejacket must be provided for each person carried onboard vessel. Vessel authorized to carry 17 passengers onboard.
46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 29 July 2024
Resolution: Acquired 01 adult lifejacket to meet COI passenger count
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024
Resolved
Each ring life buoy must be marked with type II retroreflective material. Vessel's lifebuoy missing retroreflective material.
46 CFR 185.604(h)(i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 29 July 2024
Resolution: Reflective tape added to ring buoy
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 May 2024
Resolved
Each item of lifesaving equipment determined by the Marine Inspector to not be in serviceable condition must be repaired. Lifefloat showed signs of cracking on the inner rim. Lifefloat to be repaired with manufacturer repair kit.
46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 29 July 2024
Resolution: Verified lifefloat repairs
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 April 2021
Resolved
"A vessel on a lakes, bays and sounds route must carry 3 red and 3 orange flare distress signals." 46 CFR 180.68(b)
Vessel is missing 2 orange distress signals.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2021
Resolved 28 July 2021
Resolution: Operator submitted photographs of his replaced distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2021
Resolved
"A vessel must carry a first aid kit approved under 160.041."
46 CFR 184.710
Vessel was missing first aid items.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2021
Resolved 28 July 2021
Resolution: Operator submitted photo displaying that he puurchased a new first aid kit with all of the required contents.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 11 May 2020
Resolved
The inspection of lifesaving equipment shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel did not have a lifesaving inspection log onboard.
46CFR185.702(d)
Action required: 10 - Deficiency Rectified
Due 11 May 2020
Resolved 11 May 2020
Resolution: Lifesaving equipment inspection log was created and updated in the presence of the MI.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 May 2020
Resolved
Vapor barriers must be provided where insulated of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. 01 wire run for the engine room was not sealed thus compromising the vapor barrier.
46CFR177.410(b)(e)
Action required: 10 - Deficiency Rectified
Due 11 May 2020
Resolved 11 May 2020
Resolution: The wire run was sealed to the satisfaction of the MI.