Records from 1997 to 2023. Most recent: inspection, 10 July 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
10 July 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7734543
11 May 2006
Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2646079
16 May 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2349008
3 May 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2053824
21 April 2004
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2053827
8 May 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1808444
9 May 2002
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1630466
2 May 2002
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1630328
1 November 2001
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1076257
29 August 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1054047
24 May 2000
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 817717
16 June 1999
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1103286
21 May 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 804426
8 May 1998
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1472514
2 October 1997
Initial Construction-Excluding Oversight
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1122134
Lifesaving › Hand Flares › Expired
Issued 11 May 2006
No resolution recorded
Provide flares with valid expiration dates.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2019 — due date passed with no resolution recorded
Fire Fighting › Fire Bucket › Stenciling
Issued 11 May 2006
No resolution recorded
Relabel all fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2019 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2006
No resolution recorded
Provide new eyewash for first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2019 — due date passed with no resolution recorded
Engineering › Gasoline Engine (propulsion) › Cylinder (4 cycle)
Issued 11 May 2006
No resolution recorded
Repair faulty cyliner (low compression).
Action required: 705 - Other - as specified
Due 25 May 2019 — due date passed with no resolution recorded
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2005
Resolved
Provide current copy of Coast Pilot and Marine Chart for route as per COI.
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 29 June 2005
Resolution: Attended vessel and verified as corrected.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 May 2005
Resolved
Repair stern light.
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 29 June 2005
Resolution: Attended vessel and verified that light is repaired.
Lifesaving › Lifebuoys › Serviceable
Issued 16 May 2005
Resolved
Make repairs to cracks in life ring.
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 29 June 2005
Resolution: Attended vessel and verified that a new ring has been installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2005
Resolved
Provide aspirin for first aid kit.
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 29 June 2005
Resolution: Attended vessel and verified as corrected.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 16 May 2005
Resolved
Provide 3 chairs and repair one broken chair. Note: Three chairs were removed because they were broken. Issued CG-835 indicating that vessel is limited to carrying 20 passengers until missing seating is back on board.
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 29 June 2005
Resolution: Attended vessel. All chairs have been renewed.
Construction/Loadline › Hull
Issued 21 April 2004
Resolved
Reapir crack weld on stbd pontoon spray rail.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2004
Resolved 3 May 2004
Resolution: Observed repair to starboard pontoon spray rail.
Fire Fighting
Issued 21 April 2004
Resolved
Replace worn letter "F" on fuel shut-off
Due 3 May 2004
Resolved 3 May 2004
Resolution: New letter "F" has been put in place.
Documentation
Issued 8 May 2003
Resolved
Master license espires on 5/13/03. Master may not operate the vessel after 5/13/03.
Due 13 May 2003
Resolved 13 May 2003
Resolution: Master renewed license. Faxed copy to this office.
Lifesaving › Hand Flares
Issued 8 May 2003
Resolved
Provide 3 new smoke flares. Vessel is restricted to daylight operations. No passengers permitted after sunset.
Due 31 May 2003
Resolved 8 May 2003
Resolution: Purchased new flares. Owner faxed copy of purchase.
Operations/Management
Issued 8 May 2003
Resolved
Provide eye wash in first aid kit.
Due 31 May 2003
Resolved 10 May 2003
Resolution: Purchased eye wash for first aid kit. Owner faxed copy of receipt.
Documentation
Issued 8 May 2003
Resolved
Provide proof of user fee paymnet.
Due 31 May 2003
Resolved 31 May 2003
Resolution: Owner faxed copy of check paid for user fee.
Operations/Management
Issued 9 May 2002
Resolved
Post COI and Stability letter.
Due 4 June 2002
Resolved 4 June 2002
Resolution: Posted COI and Stability letter.
Lifesaving
Issued 9 May 2002
Resolved
Stencil # of children life jackets on overhead.
Due 4 June 2002
Resolved 4 June 2002
Resolution: Stenciled # of children life jackets.
Lifesaving
Issued 9 May 2002
Resolved
Stencil # of adult life jackets on overhead.
Due 4 June 2002
Resolved 4 June 2002
Resolution: Stenciled # of adult life jackets.
Engineering
Issued 9 May 2002
Resolved
Replace fuel hose from fuel tank to engine.
Due 4 June 2002
Resolved 4 June 2002
Resolution: Installed new fuel hose.
Electrical
Issued 9 May 2002
Resolved
Proof operation of VHF radio.
Due 4 June 2002
Resolved 4 June 2002
Resolution: Conducted op test of radio. All sat.
Deck/Cargo
Issued 2 May 2002
Resolved
Repair foward starboard corner deck bracket and complete prior to carrying passengers.
Due 2 May 2002
Resolved 9 May 2002
Resolution: Repaired bracket.
Lifesaving
Issued 1 November 2001
Resolved
INSTALL MISSING FLASHLIGHT.
Condition: Unknown
Due 31 March 2002
Resolved 2 May 2002
Resolution: Installed 2 missing flashlights.
Lifesaving
Issued 1 November 2001
Resolved
REFASTEN 2 CHAIRS. PASSENGER COUNT BASED ON FIXED SEATING. VSL LIMITED TO 21 PASSENGERS.
Condition: Unknown
Due 31 March 2002
Resolved 9 May 2002
Resolution: Vessel limited to 23 passengers. Remove 2 chairs.
Lifesaving
Issued 1 November 2001
Resolved
REPLACE HEAVING LINE ON LIFERING.
Condition: Unknown
Due 9 May 2002
Resolved 9 May 2002
Resolution: Installed new heaving line on life ring.
Lifesaving
Issued 1 November 2001
Resolved
REPLACE EYE WASH BOTTLE IN FIRST AID KIT.
Condition: Unknown
Due 31 March 2002
Resolved 9 May 2002
Resolution: Installed new eye wash bottle in first-aid kit.
Lifesaving
Issued 1 November 2001
Resolved
REPLACE 3 RED FLARES.
Condition: Unknown
Due 31 March 2002
Resolved 9 May 2002
Resolution: Replaced 3 red flares.
Fire Fighting
Issued 1 November 2001
Resolved
REPLACE LANYARDS ON FIRE BUCKETS.
Condition: Unknown
Due 31 March 2002
Resolved 9 May 2002
Resolution: Installed new lanyards on fire buckets.
Lifesaving
Issued 1 November 2001
Resolved
REPLACE MISSING PORTABLE HAND BILGE PUMP.
Condition: Unknown
Due 31 March 2002
Resolved 9 May 2002
Resolution: Installed missing bilge pump.
Lifesaving
Issued 29 August 2000
Resolved
PROVIDE PROOF OF COMPANY ENROLEMENT IN THE DRUG TESTING PROGRAM.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Lifesaving
Issued 29 August 2000
Resolved
PROVIDE 60 FEET OF LINE FOR THE RING LIFE FLOAT.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000