MAURY USCG vessel records Sign in
← All vessels

SANTIAGO

SANTIAGO is a 1996 freight ship. The Coast Guard has recorded 28 inspections since 1997, most recently in March 2010, along with 14 deficiencies and 3 operational controls.

Records from 1997 to 2010. Most recent: operational control imposed, 11 March 2010.

Built
1996
Last inspected
11 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9080998 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
465326
Flag
GERMANY
—
Maury page id
psix-465326

Inspections, by type

…with no type recorded15
Years with a record 12 calendar years (1997–2010)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11511 - Regulatory (Subpart C or D), Net Ton
32355 - Dead Weight, Ton
24046 - Convention (Subpart B), Gross Ton
24046 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

11 March 2010 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3694294
1 March 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3686015
18 February 2009 PII Safety Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3419217
16 January 2009 PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3394486
3 September 2008 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3312594
1 August 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3285793
31 July 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3288952
30 April 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3204521
21 December 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3119428
13 December 2007 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3115199
14 October 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3079867
9 October 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3076602
10 May 2006 ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2646116
11 May 2005 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2354937
20 February 2005 Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2296256
4 December 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2253246
22 September 2004 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2202008
22 September 2004 ISPS III Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2202057
19 May 2004 Ballast Water Examination · MTSA/ISPS Verification · Deficiency Check · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2073391
15 October 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 294654
30 September 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1075494
11 September 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 281980
29 February 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 275275
16 September 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 432847
13 September 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 432672
13 September 1999 Passenger/Freight Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1120254
16 September 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 420341
14 October 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 408837

Deficiency record · 14

Navigation › Piloting/Steering › Gyro Compass
Issued 11 March 2010 Resolved
Gyro is inoperable. Vsl req'd to fix prior to departure. Verify with a tech report to the satisfaction of the CG.
Action required: 705 - Other - as specified
Resolved 12 March 2010
Resolution: Received tech report from Sperry Marine stating the repairs to the gyrocompass were made and is operational.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 January 2009 Resolved
Recorded Entries in the Oil Record Book for the last month indicate the flow rate through the Oily Water Separator have exceeded the maximum allowable in the I.O.P.P. form A. This is a hazard to the environment. Due to recent high turn-over in the engineering department this does not appear to be an intentional discharge.
Due 15 February 2009
Resolved 18 February 2009
Resolution: DEF RECTIFIED TO THE SATISFACTION OF THE ATTENDING FLAG REP. AND U.S.C.G. PSCO''S
Fire Fighting › Combustible Materials › Insulation
Issued 9 October 2007 Resolved
Oil soaked lagging was found on the main diesel engine and ship's service generators in the engine room crating undue fire risk. 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2007
Resolution: Received Class report, stating, "Excessive oil removed from lagging and condition of lagging now found to be within acceptable levels for an HFO vessel." Were given condition of Class, requiring all lagging found ''''soaked'''' to be replaced.
Fire Fighting › Combustible Materials › Insulation
Issued 9 October 2007 Resolved
Provisions were not made to facilitate cleaning in the engine room and various oil leaks, oily rags and full drip pans were found throughout the engine room, creating an undue fire risk. 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2007
Resolution: Received Class report, stating, "All drip pans and rags removed."
Operations/Management › Drills/Instruction › Fire
Issued 9 October 2007 Resolved
There are clear grounds for believing the master and the crew are not familiar with the essential procedures relating to the safety of ships. 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2007
Resolution: Received Class report, stating, "Master, Chief Engineer and Engineering Staff questioned about Fuel Oil leaks and fire risks associated with this and drip pans and oil rags and all professed that this would not be acceptable."
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 9 October 2007 Resolved
Waste receptacles on the fantail, engine room, and galley were make of combustible materials, creating undue fire risk. 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 October 2007
Resolution: Received Class report, stating, "Noted that 10 new metal garbage cans brought on board today to replace above combustible receptacles."
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 May 2006 Resolved
Guard rail over bay #11 portside is broken.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 December 2007
Resolution: Cleared to the satisfaction of the Coast Guard
Construction/Loadline
Issued 15 October 2001 Resolved
PORT AND STARBOARD SIDE LOADLINE NOT PERMANENTLY MARKED.
Condition: Unknown
Due 15 April 2002
Resolved 19 May 2004
Resolution: Port and Starboard LoadLine clearly marked/painted. Cleared Deficiency.
Navigation
Issued 13 September 1999 Resolved
RUDDER ANGLE INDICATOR LINKAGES NOT DOUBLE NUTTED OR COTTER PINNED.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Lifesaving
Issued 13 September 1999 Resolved
CONDUCT FIRE AND BOAT DRILLS PRIOR TO DEPARTING NEXT US PORT
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Fire Fighting
Issued 13 September 1999 Resolved
"A-0" DOORS THROUGHOUT ACCOMIDATION & SERVICE SPACES DO NOT CLOSE AUTOMATICALLY. REPAIR DOORS TO CLOSE BY THEMSELVES TO SATISFACTION OF CLASS.
Condition: Unknown
Due 12 March 2000
Resolved 12 March 2000
Fire Fighting
Issued 13 September 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 October 1999
Resolved 15 September 1999
Engineering
Issued 13 September 1999 Resolved
CONTAINMENT NOT PLUGGED DURING BUNKERING OPERATIONS.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Lifesaving
Issued 13 September 1999 Resolved
LIFELIGHTS BATTERIES INOPERATIVE. RENEW BATTERIES ON LIGHTS PRIOR TO SAILING.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999

Ownership record