← All vessels
EVER BLOSSOM
EVER BLOSSOM is a 1997 freight ship. The Coast Guard has recorded 17 inspections since 1998, most recently in November 2010, along with 4 deficiencies and 1 operational control.
Records from 1998 to 2010. Most recent: inspection, 4 November 2010.
- Built
- 1997
- Last inspected
- 4 November 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9159529 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FPT7
465328
Flag
PANAMA
—
Maury page id
psix-465328
Inspections, by type
…with no type recorded10
Years with a record
10 calendar years (1998–2010)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it23801 - Convention (Subpart B), Net Ton
72517 - Dead Weight, Ton
82622 - Displacement, Ton
37815 - Convention (Subpart B), Gross Ton
72517 - Dead Weight, Ton
82622 - Displacement, Ton
37815 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 17
4 November 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3879918
3 July 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2982062
29 June 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2977928
2 February 2006
PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2577590
29 March 2005
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2322215
18 October 2004
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2222494
16 October 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2222374
1 October 2003
Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1918745
19 June 2003
Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1821525
27 June 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1638460
16 November 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 295389
19 February 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 286989
22 April 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 427600
9 December 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 423416
9 October 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 646324
8 October 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 421278
2 May 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 415511
Deficiency record · 4
Electrical › Electrical Distribution System (service)
Issued 27 June 2002
Resolved
Vessels 440V distribution system indicates a dead ground on switchboard. SOLAS 74A II-1/45.1 LEGACY COMPONENT DESC: Ground Detection
Engineering › Diesel Engine (auxiliary)
Issued 27 June 2002
Resolved
Vessel has soft patch on lube oil suction line from oil pan of No.2 Generator.
Received Class report issuing a condition of class due for re-inspection in September 2002. LEGACY COMPONENT DESC: Crankcase
Pollution Prevention/Response › Prevention Equipment
Issued 27 June 2002
Resolved
Vessels bunkering and vent containment has non-mechanical plugs. 33 C.F.R. 155.310(3) LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Navigation
Issued 8 October 1998
Resolved
THE VESSEL'S ARPA RADAR DID NOT HAVE THE REQUIRED IMO APPROVAL LABEL. THISIS REQUIRED TO BE CORRECTED PRIOR TO THE VESSEL'S NEXT U.S. PORT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.