← All vessels
LADY MIDNIGHT
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named LADY MIDNIGHT
LADY MIDNIGHT is a 1970 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1985, most recently in July 2016, along with 309 deficiencies and 4 casualty investigations between 2006 and 2010.
Records from 1985 to 2016. Most recent: inspection, 29 July 2016.
- Built
- 1970
- Last inspected
- 29 July 2016
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 309 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2006–2010
Identity
524895
WCZ2115
46534
Flag
UNITED STATES
367451640 (licence lapsed)
Maury page id
psix-46534
Inspections, by type
…with no type recorded7
Years with a record
27 calendar years (1985–2016)
The 62 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.5 ft × 20.5 ft × 4.3 ft
Registered tonnagegross 51 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLIAM HAMMARSTROM · WARETOWN, NJ, UNITED STATES · built 1970
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
37 - Regulatory (Subpart C or D), Net Ton
37 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDF4415MMSI 367451640 · expired · compulsorily equipped · granted 11 May 2010, cancelled 11 July 2020
WCZ2115MMSI not assigned · expired · voluntarily equipped · granted 20 April 1999, cancelled 20 June 2009
WY8997MMSI not assigned · expired · compulsorily equipped · granted 18 April 1997, cancelled 8 April 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 62
29 July 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5956737
5 December 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4201873
11 May 2009
Annual Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3498911
21 May 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3212964
21 April 2008
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3192288
9 September 2007
Deficiency Check · COI Inspection · Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3054018
9 September 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3054529
25 May 2007
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2945044
10 May 2007
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2926712
25 April 2007
Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2974729
16 September 2006
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2779770
16 September 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2781032
3 July 2006
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2699670
24 June 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2782907
23 June 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2688963
17 May 2006
Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2653885
4 August 2005
Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2451225
11 May 2005
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2354815
20 August 2004
MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2171442
10 April 2003
Hull Examination · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1771323
20 May 2002
MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1618432
20 February 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1487868
17 August 2001
Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1384855
4 May 2001
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1399612
11 September 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 822283
15 August 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1052583
15 June 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1379104
13 July 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1102290
13 July 1999
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1102292
27 May 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1471386
4 May 1999
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1127098
6 April 1999
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1458621
30 April 1998
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 791740
27 March 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 787513
9 March 1998
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 783032
17 November 1997
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1443935
14 November 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 169380
24 April 1997
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1114831
28 March 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1104501
19 March 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1099550
22 March 1996
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1079650
6 March 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 884988
27 March 1995
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1145678
3 March 1995
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1166066
7 April 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1389805
14 March 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1442115
30 March 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1373827
16 March 1993
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1403600
6 July 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 165893
10 April 1992
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1264703
26 February 1992
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1263750
22 April 1991
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 932673
27 March 1991
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 906411
14 March 1991
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 906410
19 March 1990
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 928767
22 February 1990
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 925647
28 March 1989
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1040388
1 March 1989
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1045133
29 March 1988
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 990668
10 April 1987
Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1334298
4 March 1986
Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1299031
19 March 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1287954
Deficiency record · 309
Documentation › Certificates/Documents › Stability Letter
Issued 5 December 2011
Resolved
Owner/Operator failed to submit stability certification compliance by 01DEC11. Issued CG-835 reducing maximum passengers allowed to 96 based on the assumed average weight per person of 185 pounds and in accordance with 46 CFR 178.320 amended by FR vol. 75, No. 239, USCG-2007-0030. Reduction will remain in effect until Owner/Operator submits stability certification compliance to Coast Guard
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 August 2009
Resolved
The Certificate of Documentation expired on June 30, 2009. Provide a new Certificate of Documentation and place the original on board prior to carrying passengers.
Communications › Radio Communications › EPIRB
Issued 27 August 2009
Resolved
Provide proof of registration for the Category I, 406 Mhz EPIRB. Vessel representative was unable to produce any papers verifying that the EPIRB was currently registered with NOAA and the registration sticker was not affixed to the EPIRB. Vessel is restricted to operations less than three miles from shore.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 31 July 2009
Resolved
Complete u/w exam with attending Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 May 2009
Resolved
Replace jacket water cooling line pipe starboard side MDE.
Construction/Loadline › Hull › Transverse Frame
Issued 11 May 2009
Resolved
Make repairs to hull and first three frames port side in forepeak. Vessel was taking on water during underway inspection.
Construction/Loadline › Hull › Transverse Frame
Issued 11 May 2009
Resolved
Make repairs to first four frames in way of keel port and starboard side aft of watertight bulkhead in compartment three.
Construction/Loadline › Hull › Transverse Frame
Issued 21 April 2008
Resolved
C/R btm 2nd stanchion, IWO tranverse long. Prior to carrying passengers.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 April 2008
Resolved
Install blank IWO breaker box, located in void #3.
Construction/Loadline › Hull › Hull Plating
Issued 21 April 2008
Resolved
Seal all blkd openings as discussed (void#3) IWO aft blkd (02 total).
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 21 April 2008
Resolved
Replace wasted sea water inlet hoses for stbd engine (02 total).
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 21 April 2008
Resolved
Replace worn lifejackets (02 total).
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 April 2008
Resolved
Replace worn retro tape (with approved type) to 17 adult lifejackets and 01 child lifejacket.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 21 April 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 April 2008
Resolved
Relocate stern light to provide maximum visibility.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 21 April 2008
Resolved
Provide for Oil Pollution placard onboard vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 21 April 2008
Resolved
- Replace RPM gauge IWO port engine.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 October 2007
Resolved
Line battery boxes in engine compartment with material that is resistant to damage by the electrolyte IAW 46CFR 183.350 (c)
Stability › Watertight Integrity › General
Issued 9 September 2007
Resolved
Repair water leak in generator room IWO keel bolt.
Engineering › Bilge Water Management System › Not Operational
Issued 9 September 2007
Resolved
Repair disconnected bilge alarm/pump switch in steering gear compartment.
Engineering › Bilge Water Management System › Pump
Issued 9 September 2007
Resolved
Prove proper operation of all bilge alarms and pumps.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 9 September 2007
Resolved
Provide name and hailing port on stern of vessel.
Lifesaving › Lifefloat › Markings
Issued 9 September 2007
Resolved
Properly mark lifefloats with vessel name and person capacity.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 September 2007
Resolved
Prove proper operation of all waterlights on board.
Navigation › Piloting/Steering › Marine Charts
Issued 9 September 2007
Resolved
Provide updated charts and publications.
Stability › Watertight Integrity › General
Issued 9 September 2007
Resolved
Repair water leak in steering gear compartment IWO rudder post.
Engineering › Steering Gear System › Rudder Stock
Issued 9 September 2007
Resolved
Test steering gear underway noting rudder post leakage.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 September 2007
Resolved
Provide proof of all crew participation in drug/alcohol testing program.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 September 2007
Resolved
Remove expired COI decal from port cabin window.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 9 September 2007
Resolved
Remove all standing oil from engine and generator room bilges.
Stability › Watertight Integrity › General
Issued 9 September 2007
Resolved
Repair/replace steering gear compartment hatch cover and trip hazard on generator room hatch cover.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 9 September 2007
Resolved
Prove proper operation of toilet facilities.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 September 2007
Resolved
Properly support wire runs in generator and engine space (every 24”) IAW 46CFR183.340 (a) (4).
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 9 September 2007
Resolved
Provide blank for open space in distribution panel in generator space.
Engineering › Bilge Water Management System › Piping
Issued 9 September 2007
Resolved
Properly support bilge piping throughout vessel.
Engineering › Bilge Water Management System › Piping
Issued 9 September 2007
Resolved
Situate bilge suction in lazarette closer to bilge.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 9 September 2007
Resolved
Provide proof of full compliance with drug and alcohol program.
Engineering › Bilge Water Management System › Piping
Issued 9 September 2007
Resolved
Properly label bilge manifold system.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 September 2007
Resolved
Remove dead-end wore behind shelf fwd passenger space (behind bar).
Engineering › Freshwater Generation System › Piping
Issued 9 September 2007
Resolved
Remove obsolete PVC piping behind bar.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 September 2007
Resolved
Properly install pre-engineered fixed fire extinguishing system bottle. Ensure nozzle is facing aft bulkhead.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 September 2007
Resolved
CR10 Replace bottle in way of fixed fire extinguishing system.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 September 2007
Resolved
Ensure fire fighting hose is attached at fire hydrant at all times. IAW 46CFR 181.15-10 (2) (g).
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 September 2007
Resolved
Provide logbook onboard vessel and properly log man-overboard drills/fire drills/and monthly EPIRB tests.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 September 2007
Resolved
Provide first aid kit that meets 46CFR160.041.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 September 2007
Resolved
Remove household screw type wire splice connectors from ships whistle and beneath operating station and replace with crimp type connectors.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 September 2007
Resolved
Mark all high-water alarms at operating station.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 September 2007
Resolved
Remove all dead end wires beneath operators station.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 9 September 2007
Resolved
Repair damaged fixed seating port side second deck.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 9 September 2007
Resolved
Remove electrical tape from buoyant apparatus painter and provide means to ensure all line will pay out properly.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 September 2007
Resolved
Repair side screen IWO stbd navigation lights.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 September 2007
Resolved
Properly label distribution panel at operating station.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 September 2007
Resolved
Prove proper operation of indicator lights at operators IWO automatic electric submersible bilge pumps.
Communications › Radio Communications › EPIRB
Issued 9 September 2007
Resolved
Provide proof of satisfactory battery date for 406MZ EPIRB or replace the same.
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 9 September 2007
Resolved
Provide caps for engine room vents.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 9 September 2007
Resolved
Replace fuel tank vents screens.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 September 2007
Resolved
Provide emergency instructions for fire, man over board and rough weather at sea.
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 September 2007
Resolved
Conduct satisfactory fire and man overboard drills in presence of USCG Marine Inspector.
Engineering › Bilge Water Management System › Piping
Issued 9 September 2007
Resolved
Properly support flexible hose above bilge IWO fixed pump on port engine.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 9 September 2007
Resolved
Make permanent repairs to wet exhaust in way of starboard engine.
Construction/Loadline › Hull › Hull Plating
Issued 25 May 2007
Resolved
Repair inset, starboard side IVO of keel as indicated by Marine Inspector.
Construction/Loadline › Penetrations › Valve Flange
Issued 25 May 2007
Resolved
Remove all sea valves and make available for inspection.
Construction/Loadline › Hull › Hull Plating
Issued 25 May 2007
Resolved
Grind and make repairs to all areas of delamination as indicated by Marine Inspector.
Construction/Loadline › Structures › End Bulkhead
Issued 25 May 2007
Resolved
Refasten forward bulkhead, void #2.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 May 2007
Resolved
Replace wasted steel flange/bulkhead penetration in way of starboard main engine wet exhaust.
Engineering › Freshwater System (jacketwater cooling) › Suction Strainer
Issued 25 May 2007
Resolved
Remove raw water intake strainers for port and starboard main engine and make ready for inspection.
Construction/Loadline › Hull › Keel
Issued 25 May 2007
Resolved
Re-caulk hull/keel interface, port and starboard sides as indicated by Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 May 2007
Resolved
Replace fire extinguisher bracket with correct type/size in main cabin s/s IAW 46 CFR 181.520.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 25 May 2007
Resolved
Fire extinguishers have excessive corrosion, are overcharged, and in incorrect brackets replace IAW 46 CFR 176.810
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2007
Resolved
Prior to operating with passengers onboard submit as built plans for the electrical system.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2007
Resolved
Prior to operating with passengers onboard have the electrical system inspected for compliance with the approved plans.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 April 2007
Resolved
Provide copy of current Certificate of Documentation.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 April 2007
Resolved
Install covers on junction boxes for lights installed in #2 void and generator space.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 April 2007
Resolved
Post Emergency Instructions List.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 April 2007
Resolved
Install guard for light in generator space.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 April 2007
Resolved
Replace cracked and leaking wet exhaust water supply hose for port main diesel engine.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 April 2007
Resolved
Secure water leak from port wet exhaust muffler located in lazarette.
Construction/Loadline › Structures › Deck Plating
Issued 25 April 2007
Resolved
Repair crack in deck, starboard bow, IWO #2 void.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2007
Resolved
Provide replacement for expired items in first aid kit.
Electrical › Electric Generation Source (service) › Generator
Issued 25 April 2007
Resolved
Vessel generator has been removed from the vessel. Vessel owner to prove how present configuration of electrical system meets requirement of special consideration for vital systems as required by 46 CFR 183.01-10.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 September 2006
Resolved
Port main diesel engine exhaust (wet) pipe ruptured and flooded the engine room with salt water from the cooling pumps. Make repairs to the satisfaction of the Marine Inspector prior to carrying passengers.
Engineering › Bilge Water Management System › Pump
Issued 16 September 2006
Resolved
The engine room automatic bilge pump was discharging oily bilge waste overboard. Secure the automatic pump, clean the pump, discharge line, and the engine room bilge to the satisfaction of the Marine Inspector prior to carrying passengers.
Electrical › Electrical Distribution System (service) › Cable
Issued 16 September 2006
Resolved
Remove the jury rigged extension cord that is hard wired to the distribution panel in the generator compartment. This is the second time this requirement has been issued in the last 4 months.
Engineering › Bilge Water Management System › Hose
Issued 16 September 2006
Resolved
Replace the crushed bilge/fire pump hose withy approved materials IAW 46CFR182.25-1 / 46CFR182.40-5, and properly mount the pump.
Engineering › Bilge Water Management System › Strainer
Issued 16 September 2006
Resolved
The bilge suction line in the lazerett is missing the strainer. Replace the bilge strainer in the lazerett IAW 46CFR182.25-5(b). Strainer must have an open area of not less than three times the area of the bilge pipe.
Engineering › Bilge Water Management System › Pump
Issued 16 September 2006
Resolved
The automatic bilge pump in the fore peak is not mounted. Permanently mount the automatic bilge pump IAW 46CFR182.520.
Stability › Watertight Integrity › General
Issued 16 September 2006
Resolved
Dewater all compartments and make the vessel ready for & underway inspection.
Engineering › Bilge Water Management System › Pump
Issued 16 September 2006
Resolved
Once all of the bilges are free of oily waste prove proper operation of all of the bilge pumps to the satisfaction of the attending Marine Inspector.
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 September 2006
Resolved
The high bilge level alarm in the fore peak is not working. Prove proper operation of the bilge level alarm to the attending Marine Inspector.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 16 September 2006
Resolved
Vessel COI was not posted as required by 46 CFR 100(b).
Engineering › Generator (propulsion-electric) › Battery
Issued 3 July 2006
Resolved
Prove proper operation of vessel's generator to attending USCG inspector. Vsl is restricted to day time ops.
Engineering › Generator (propulsion-electric) › Junction Box
Issued 3 July 2006
Resolved
Remove jury rigged shore tie cable from generator junction box prior to taking passenger.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 July 2006
Resolved
Various f/o hoses on the main engines are damaged and chafed beyond a reasonable service life. Replace as needed.
Engineering › Generator (propulsion-electric) › Junction Box
Issued 30 June 2006
Resolved
Generator space bilges have heavy oil and fuel accumulation at hazardous levels. Prior to sailing remove accumulated oil IAW 46 CFR 189.25-45.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 May 2006
Resolved
Repair exhaust leak on on stbd engine lagging connection to manifold.
Engineering › Bilge Water Management System › Pump
Issued 17 May 2006
Resolved
Prove proper operation of bilge pump.
Fire Fighting › Fire Pumps › Gears
Issued 17 May 2006
Resolved
Prove proper operation of fire pump.
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 May 2006
Resolved
Conduct sea trials to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 May 2006
Resolved
Install junction box cover in #2 void overhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2006
Resolved
Remove electrical wire between #2 void and #3 void and make hole watertight.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2006
Resolved
Remove electrical wire in #3 void on port side aft bulkhead.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 May 2006
Resolved
Make aft bulkhead in #3 void watertight.
Construction/Loadline › Hull › Transverse Frame
Issued 17 May 2006
Resolved
Remove angel hairing on overhead in void #3
Construction/Loadline › Hull › Transverse Frame
Issued 17 May 2006
Resolved
Remove angel hairing on overhead in engine room.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 17 May 2006
Resolved
Provide waterlight for middle BA.
Engineering › Generator (propulsion/auxiliary-electric) › Receptacle
Issued 17 May 2006
Resolved
Remove and properly dispose of oil in gen. tray.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 17 May 2006
Resolved
Reclamp wet exhaust line to prevent dripping located in port side laz.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 May 2006
Resolved
Splice lifeline around body of ring buoy.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 May 2006
Resolved
Replace clip on waterlight lanyard for ring buoy.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2006
Resolved
Terminate dead end wires under bridge console.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2006
Resolved
Terminate dead end wires in laz aft bilge.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 May 2006
Resolved
Post emergency broadcast placard near radio.
Communications › Audible Communications › Horn/Whistle
Issued 17 May 2006
Resolved
Prove operation of signalling horn.
Documentation › Certificates/Documents › FCC SSL
Issued 17 May 2006
Resolved
Provide radio operator permit.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 May 2006
Resolved
Provide training log.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 May 2006
Resolved
Prove operation of bilge alarms.
Communications › Radio Communications › EPIRB
Issued 17 May 2006
Resolved
Properly attach EPIRB in its float free arangement.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 May 2006
Resolved
Write letter to OCMI stating how you lost original COI and request a new one.
Engineering › Fuel Oil Service System › Piping
Issued 4 August 2005
Resolved
Locate source of fuel leak on S/S MDE & repair same.
Engineering › Fuel Oil Service System › Piping
Issued 4 August 2005
Resolved
Remove fuel oil servicing line from wire bundle on S/S MDE & reattach same a safe distance away from wire bundle.
Lifesaving › Lifefloat › Not on Board
Issued 4 August 2005
Resolved
Replace 03 BA's with 03 (20 person) lifefloats.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 4 August 2005
Resolved
Replace 01 child lifejacket.
Stability › Weathertight Integrity › General
Issued 4 August 2005
Resolved
Replace broken pilot house S/S sliding window.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 August 2005
Resolved
Repair wet exhaust leak on inboard side elbow fittings of both MDE's.
Engineering › Diesel Engine (propulsion-direct drive) › Crosshead Assembly
Issued 4 August 2005
Resolved
Repair bonding strap on S/S MDE fuel tank.
Stability › Watertight Integrity › General
Issued 4 August 2005
Resolved
Cap off through hull fitting in generator compartment.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 August 2004
Resolved
Provide oringinal certificate of documentation.
Documentation › Certificates/Documents › FCC SSL
Issued 20 August 2004
Resolved
Provide current\valid FSS station license.
Documentation › Certificates/Documents › Stability Letter
Issued 20 August 2004
Resolved
Provide original stability letter.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 August 2004
Resolved
Prove operation of radion on bridge.
Navigation › Piloting/Steering › Magnetic Compass
Issued 20 August 2004
Resolved
Install red night light for bridge compass.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 20 August 2004
Resolved
Remove oil/water from all bilges.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 August 2004
Resolved
Provide complete first aid kit.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 20 August 2004
Resolved
Double clamp electric bilge hose, void #1.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 20 August 2004
Resolved
Double clamp electric bilge hose, void #2.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 20 August 2004
Resolved
Void #3 - G/R, double clamp electric bilge hose.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 20 August 2004
Resolved
Void #3 - G/R, remove deadend wires from electric bilge.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 August 2004
Resolved
Void #3 - G/R, install door for circuit panel.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 August 2004
Resolved
Void #3 - G/R, install circuit diagram.
Electrical › Electric Generation Source (service) › Generator
Issued 20 August 2004
Resolved
Void #3 - G/R, remove yellow rope from generator sea strainer and install proper support.
Electrical › Electric Generation Source (service) › Generator
Issued 20 August 2004
Resolved
Prove proper operation of generator, no night ops.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 August 2004
Resolved
Tighten hand rail main deck portside fwd.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 20 August 2004
Resolved
Properly service B-I and B-II fire extinguishers.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 20 August 2004
Resolved
Service discharged B-II fire extinguisher stbdside accom space.
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 20 August 2004
Resolved
Remove bucket of diesel under fuel vent from overfill of fuel tank.
Construction/Loadline › Structures › End Bulkhead
Issued 20 August 2004
Resolved
Make lazarette fwd WTB watertight by sealing penetrations properly.
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 August 2004
Resolved
Replace all hose clamps on P/S engine raw water cooling flex hoses.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 20 August 2004
Resolved
Replace & double clamp sewage overboard discharge flex hose.
Engineering › Bilge Water Management System › Hose
Issued 20 August 2004
Resolved
Replace flex hoses installed as primary bilge suction monifold for voids #3 & #4, dry rotted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 20 August 2004
Resolved
Prove proper operation of fixed fire extinguishing system engine shutdown for stbd engine.
Fire Fighting › Fire Pumps › Pressure
Issued 20 August 2004
Resolved
Prove proper operation of belt driven fire/bilge pump.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 20 August 2004
Resolved
Prove proper operation of bilge high level alarm in lazarrette.
Engineering › Bilge Water Management System › Pump
Issued 20 August 2004
Resolved
Prove proper operation of electic bilge pump in lazarette.
Communications › Audible Communications › Horn/Whistle
Issued 20 August 2004
Resolved
Prove proper operation of bridge horn.
Communications › Audible Communications › SPD (Other)
Issued 20 August 2004
Resolved
Porve proper operation of public address system.
Communications › Radio Communications › EPIRB
Issued 20 August 2004
Resolved
Prove valid EPIRB register with NOAA - vsl not permitted past 3 NM.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 August 2004
Resolved
Prove operation of deck lights and lights in pax accom space.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 20 August 2004
Resolved
Post PFD donning placards for all PFD types.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 20 August 2004
Resolved
Provide documentation of preperly sized and approved weak link.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 20 August 2004
Resolved
Provide 12 additional adult PFDs to meet COI requirements - vsl limited to 100 adult pax.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 20 August 2004
Resolved
Conduct underway sea trials.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 20 August 2004
Resolved
Repack both P/S shafts that were observed to be excessively leaking.
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 April 2003
Resolved
Replace reflective tape as needed on adult life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Construction/Loadline › Structures
Issued 10 April 2003
Resolved
Repair broken seat affixed to pilot house second deck port side. LEGACY COMPONENT DESC: Superstructure
Operations/Management › Drug and Alcohol Testing
Issued 10 April 2003
Resolved
Provide proof of enrollment for the entire crew in a drug and alcohol monitoring program. LEGACY COMPONENT DESC: Employee Coverage
Lifesaving › Hand Flares
Issued 10 April 2003
Resolved
Provide proper number of day flares for the required route. Vessel restricted to Lakes, Bays and Sound Route until cleared by attending marine inspector. LEGACY COMPONENT DESC: Quantity
Communications › Radio Communications
Issued 10 April 2003
Resolved
Replace expired battery in EPIRB. restricted to operating no more than three miles from shore until cleared by attending marine inspector. LEGACY COMPONENT DESC: EPIRB
Engineering
Issued 10 April 2003
Resolved
Repair /Replace RPM and Reduction gear gages.
Lifesaving › Lifebuoys
Issued 10 April 2003
Resolved
Replace Life Ring
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 April 2003
Resolved
Update ointments in first aid kit.
Engineering › Diesel Engine (auxiliary)
Issued 10 April 2003
Resolved
install machinery guard and breather on generator.
Engineering › Freshwater System (jacketwater cooling)
Issued 10 April 2003
Resolved
Replace hoses as marked on port and starboard MDE LEGACY COMPONENT DESC: Hose
Engineering › Steering Gear System › Rudder Bearing
Issued 10 April 2003
Resolved
Address leak to starboard rudder post
Engineering › Bilge Water Management System
Issued 10 April 2003
Resolved
Clean bilge area in lazarette
Construction/Loadline › Hull
Issued 10 April 2003
Resolved
Complete treatment of areas sanded back in engine room that addressed angel hair. LEGACY COMPONENT DESC: Transverse Frame
Operations/Management › Drills/Instruction
Issued 10 April 2003
Resolved
Complete drills to the satisfaction of the attending marine inspector LEGACY COMPONENT DESC: Man Overboard Recovery
Documentation › Certificates/Documents
Issued 10 April 2003
Resolved
Provide Copy of Certificate of Documentation.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 April 2003
Resolved
Replace vital system hoses as marked on port and stbd MDE
Fire Fighting › Combustible Materials
Issued 10 April 2003
Resolved
Remove sanded angel hair from engine space as well as on top of MDE's
Documentation › Certificates/Documents
Issued 31 July 2002
Resolved
Mount copy of COI in visable location. LEGACY COMPONENT DESC: Certificate of Inspection
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 31 July 2002
Resolved
Affix/paint name of vsl on hull.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 31 July 2002
Resolved
Repair exhaust lagging on stbd engine.
Engineering › Bilge Water Management System › Interface Detector
Issued 31 July 2002
Resolved
Make E/R bilges oil and water free.
Documentation › Certificates/Documents
Issued 20 May 2002
Resolved
Provide Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Documentation › Certificates/Documents
Issued 20 May 2002
Resolved
Provide proof that vessel's crew is enrolled in a valid DAPI program. LEGACY COMPONENT DESC: Proof of Consortium Enrollment (DAPI)
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 20 May 2002
Resolved
Provide servicing records for portable fire extinguishers anf fixed halon fire extinguishing system. LEGACY COMPONENT DESC: Serviced
Documentation › Logs/Records
Issued 20 May 2002
Resolved
Provide a training and bridge logbook. LEGACY COMPONENT DESC: Logbook (official)
Documentation › Logs/Records
Issued 20 May 2002
Resolved
Ensure EPIRB is tested monthly and logged. LEGACY COMPONENT DESC: Logbook (official)
Navigation › Piloting/Steering
Issued 20 May 2002
Resolved
Provide navigation publications (Light List, Coast Pilot). LEGACY COMPONENT DESC: Coast Guard Light List
Navigation › Piloting/Steering
Issued 20 May 2002
Resolved
Ensure light to magnetic compass is operational. LEGACY COMPONENT DESC: Magnetic Compass
Lifesaving › Hand Flares
Issued 20 May 2002
Resolved
Ensure vessel is equipped with 6 orange and 6 red flares. LEGACY COMPONENT DESC: Quantity
Construction/Loadline › Structures
Issued 20 May 2002
Resolved
Ensure all bulkhead penetrations are watertight. LEGACY COMPONENT DESC: Transverse Bulkhead
Stability › Watertight Integrity
Issued 20 May 2002
Resolved
Remove all standing water from forepeak, second compartment, and lazarette.
Lifesaving › Buoyant Apparatus
Issued 20 May 2002
Resolved
Provide spacers between Buoyant Appartus LEGACY COMPONENT DESC: spacers
Accommodation/Occupational Safety › Occupational Safety
Issued 20 May 2002
Resolved
Replace glass louvers (window) to heads
Electrical › Lighting (service)
Issued 20 May 2002
Resolved
Replace glass lighting fixtures and guards to exterior lighting. LEGACY COMPONENT DESC: Lighting Fixture
Engineering › Bilge Water Management System
Issued 20 May 2002
Resolved
Ensure rule submersible pumps are properly mounted and wired correctly. LEGACY COMPONENT DESC: Pump
Construction/Loadline › Structures
Issued 20 May 2002
Resolved
Ensure deck hatches are watertight (replace gaskets). LEGACY COMPONENT DESC: Manhole
Accommodation/Occupational Safety › Medical/First Aid
Issued 20 May 2002
Resolved
Provide first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Engineering › Fuel Oil Service System
Issued 20 May 2002
Resolved
Make fuel shut off valves accessible and mark properly. LEGACY COMPONENT DESC: Valve, Control
Engineering
Issued 20 May 2002
Resolved
Ensure vital piping systems are doubled clamped properly where the metallic piping is not flared (port engine exhaust, sea suction) LEGACY COMPONENT DESC: Vital Piping Systems
Electrical › Electric Supply System (service)
Issued 20 May 2002
Resolved
Make repairs to engine room battery box. LEGACY COMPONENT DESC: Battery Installation
Electrical › Electric Generation Source (service)
Issued 20 May 2002
Resolved
Repair grounding strip next to battery box. LEGACY COMPONENT DESC: Grounding Conductor
Accommodation/Occupational Safety › Ventilation
Issued 20 May 2002
Resolved
Provide means to secure ventilation to engine room.
Communications › Alarms/Indicators
Issued 20 May 2002
Resolved
Ensure the lazarette high level alarm is operating correctly. LEGACY COMPONENT DESC: Bilge Alarm
Electrical › Electric Generation Source (service)
Issued 20 May 2002
Resolved
Make permanent repairs to the generator. LEGACY COMPONENT DESC: Generator
Electrical › Electrical Distribution System (service)
Issued 20 May 2002
Resolved
Replace air conditioning fuse box panel door. LEGACY COMPONENT DESC: Switchboard
Engineering › Bilge Water Management System
Issued 20 May 2002
Resolved
Provide portable hand bilge pump. LEGACY COMPONENT DESC: Pump
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 20 May 2002
Resolved
Ensure portable fire extinguishers are properly mounted. LEGACY COMPONENT DESC: Mounting Bracket
Accommodation/Occupational Safety › Occupational Safety
Issued 20 May 2002
Resolved
Provide portable lights at pilot house and at entrance of engine room.
Operations/Management › Pollution
Issued 20 May 2002
Resolved
Make repairs to Marine Sanitation Tank. Ensure valve configuration is set up to discharge directly into MSD Tank. LEGACY COMPONENT DESC: Control of Discharge of Sewage
Stability › Watertight Integrity
Issued 20 May 2002
Resolved
Make repairs to stbd rudder post.
Electrical › Electrical Distribution System (service)
Issued 20 May 2002
Resolved
Ensure wiring is properly suppoted throughout engine room. LEGACY COMPONENT DESC: Wiring
Electrical › Electrical Distribution System (service)
Issued 20 May 2002
Resolved
Remove all dead end wiring in engine room. LEGACY COMPONENT DESC: Wiring
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 May 2002
Resolved
Replace/clean air filters and drainage lines. LEGACY COMPONENT DESC: Air Cleaner
Construction/Loadline › Hull
Issued 20 May 2002
Resolved
Ensure hole in deck in way of deck windlass hyraulic lines is plugged making the deck watertight. LEGACY COMPONENT DESC: deck
Communications › Radio Communications
Issued 20 May 2002
Resolved
Prove EPIRB has been registered with NOAA. Vsl limited to no more than 3 miles from shore. LEGACY COMPONENT DESC: EPIRB
Lifesaving › Lifejacket/PFD (Type I)
Issued 20 May 2002
Resolved
Vsl limited to 101 adult passengers and 11 children on a warm water L, B, & Sounds route. LEGACY COMPONENT DESC: Quantity
Operations/Management › Drills/Instruction
Issued 20 May 2002
Resolved
Vsl required to conduct a man over board drill and ensure all machinery is in good working order. LEGACY COMPONENT DESC: Man Overboard Recovery
Lifesaving
Issued 17 August 2001
Resolved
Label upper deck with "No Passengers."
Electrical
Issued 17 August 2001
Resolved
Properly splice wires under console.
Construction/Loadline
Issued 17 August 2001
Resolved
Make bilges ready for inspection - remove all water.
Construction/Loadline
Issued 17 August 2001
Resolved
Prove proper operation of bilge systems, both fixed and electric.
Construction/Loadline
Issued 17 August 2001
Resolved
Provide suitable type of bilge hose for generator and engine compartments (installed hose not suitable for petro liquids).
Documentation
Issued 17 August 2001
Resolved
Provide bridge log to include training, maintenance and drills.
Lifesaving
Issued 17 August 2001
Resolved
Properly store, mark and keep child lifejackets separate.
Engineering
Issued 17 August 2001
Resolved
Re-plumb fuel tank vent with proper material and install flame screens (steering compartment).
Documentation
Issued 17 August 2001
Resolved
Provide current Safety Radio Certificate.
Documentation
Issued 17 August 2001
Resolved
Provide current Certificate of Documentation.
Fire Fighting
Issued 17 August 2001
Resolved
Provide means of securing engine room vents.
Electrical
Issued 17 August 2001
Resolved
Install proper battery (remove automotive and replace with marine grade - beneath console).
Construction/Loadline
Issued 17 August 2001
Resolved
Make all bulkhead penetrations watertight (compartment #2).
Construction/Loadline
Issued 17 August 2001
Resolved
Install positive shutoff valve for electric pump at hull penetration (compartment #2).
Construction/Loadline
Issued 17 August 2001
Resolved
Install positive shutoff valve for electric pump at hull penetration (compartment #3).
Electrical
Issued 17 August 2001
Resolved
Remove improperly installed drop lights (engine room).
Construction/Loadline
Issued 17 August 2001
Resolved
Make bulkheads watertight (engine room).
Accommodation/Occupational Safety
Issued 17 August 2001
Resolved
Repair top deck port side aft safety rail life lines.
Construction/Loadline
Issued 17 August 2001
Resolved
Make all bulkhead penetrations watertight (compartment #1).
Construction/Loadline
Issued 17 August 2001
Resolved
Repair lazaret bilge alarm.
Construction/Loadline
Issued 17 August 2001
Resolved
PROVIDE SUITABLE HAND BILGE PUMP.
Lifesaving
Issued 17 August 2001
Resolved
STENCIL TOP DECK WITH MAX NUMBER OF PASSENGERS PER STABILITY LETTER.
Construction/Loadline
Issued 17 August 2001
Resolved
Properly mount bilge pump and float switches (engine room).
Engineering
Issued 17 August 2001
Resolved
Replace port engine seawater suction hose (cracked/wire showing through).
Lifesaving
Issued 17 August 2001
Resolved
Properly install new line to all buoyant apparatus (life lines, pendants and painter).
Electrical
Issued 17 August 2001
Resolved
Remove all unused "dead end" wiring.
Construction/Loadline
Issued 17 August 2001
Resolved
Show proper operation and familiarity with newly installed bilge alarm system.
Electrical
Issued 17 August 2001
Resolved
Remove dead battery (beneath console).
Lifesaving
Issued 17 August 2001
Resolved
Renew hydrostatic release for EPIRB.
Accommodation/Occupational Safety
Issued 17 August 2001
Resolved
Prove proper operation of mail/female toilets.
Construction/Loadline
Issued 17 August 2001
Resolved
Prove proper operation of all deck hatches (missing dogs, seized and broken).
Accommodation/Occupational Safety
Issued 17 August 2001
Resolved
Replace cracked window, stbd side forward.
Fire Fighting
Issued 17 August 2001
Resolved
Renew fire/garden hose (holed).
Lifesaving
Issued 17 August 2001
Resolved
Provide water light for buoyant apparatus.
Construction/Loadline
Issued 17 August 2001
Resolved
Properly mount electric bilge pump and float switches (compartment #1).
Construction/Loadline
Issued 17 August 2001
Resolved
Properly attach reach rod for bilge suction valve (compartment #1).
Electrical
Issued 17 August 2001
Resolved
Remove improperly installed hard wired drop lights (compartment #3).
Construction/Loadline
Issued 17 August 2001
Resolved
Install positive shutoff valve at hull penetration for electric pump (compartment #1).
Engineering
Issued 4 May 2001
Resolved
provide gauging report for fuel tanks
Construction/Loadline
Issued 4 May 2001
Resolved
Mount High level bilge alarm float.
Construction/Loadline
Issued 4 May 2001
Resolved
Replace Bilge valve reach rod for fwd compartment.
Construction/Loadline
Issued 4 May 2001
Resolved
Replace flex hose for bilge suction in forepeak.
Construction/Loadline
Issued 4 May 2001
Resolved
Repair/replace #6 frm from fwd, port side, cmpt #3
Construction/Loadline
Issued 4 May 2001
Resolved
Repair #2 frm fwd transverse web frame, check fastener.
Construction/Loadline
Issued 4 May 2001
Resolved
Repair/replace #9 rib frm from fwd, port side
Navigation
Issued 4 May 2001
Resolved
Replace rudder packing for both port and stbd rudder posts.
Navigation
Issued 4 May 2001
Resolved
Refasten port side uppoer rudder post support to prevent movement.
Navigation
Issued 4 May 2001
Resolved
repair stbd rudder where cracked.
Construction/Loadline
Issued 4 May 2001
Resolved
Replace gen. sea suction hose in Gen. room
Construction/Loadline
Issued 4 May 2001
Resolved
Make bottom of hull and all through-hull fitting available for insp.
Engineering
Issued 4 May 2001
Resolved
Repair water leak on salt water supply iwo port main engine strainer.
Engineering
Issued 4 May 2001
Resolved
Replace hose clamp on main engine exhaust port side near "Y"
Construction/Loadline
Issued 4 May 2001
Resolved
Ensure double hose clamps on all bilge hoses at bilge manifold.
Navigation
Issued 4 May 2001
Resolved
Replace upper locking bolt on stbd side rudder post
Documentation
Issued 15 June 2000
Resolved
PROVIDE PROOF OF VESSEL'S CERTIFICATE OF DOCUMENTATION ANNUAL RENEWAL.
Lifesaving
Issued 15 June 2000
Resolved
PROVIDE PROOF OF VALID EPIRB REGISTRATION WITH NOAA.
Electrical
Issued 15 June 2000
Resolved
PROPERLY MOUNT/SECURE THE COOLANT OVERFLOW TANK FOR GENERATOR.
Engineering
Issued 15 June 2000
Resolved
PROPERLY INSTALL A MACHINERY GUARD ON FRONT OF GENERATOR.
Construction/Loadline
Issued 15 June 2000
Resolved
PROVE PROPER OPERATION OF BILGE HIGH LEVEL ALARM IN LAZARETTE.
Fire Fighting
Issued 15 June 2000
Resolved
PROVIDE PROOF OF ANNUAL FIXED FIRE EXTINGUISHING SERVICING IN ENGINE ROOM.
Lifesaving
Issued 27 May 1999
Resolved
Provide onboad first aid kit.
Navigation
Issued 27 May 1999
Resolved
Provide day shape IAW Nav Rules.
Construction/Loadline
Issued 27 May 1999
Resolved
Repair bilge/fire pump leak. Leak is IWO seal and pump will not take suction.
Electrical
Issued 27 May 1999
Resolved
Install ventilated battery covers engine room.
Construction/Loadline
Issued 27 May 1999
Resolved
Double hose clamp fire pump suction IWO skin valve
Fire Fighting
Issued 27 May 1999
Resolved
Test fixed fire fighting system.
Engineering
Issued 27 May 1999
Resolved
Provide double hose clamps on generator exhaust.
Documentation
Issued 27 May 1999
Resolved
provide evidence of enrollment in drug and alcohol testing program.
Documentation
Issued 27 May 1999
Resolved
Provide onboard a copy of 46 CFR 166-199.
Documentation
Issued 27 May 1999
Resolved
Vessel is not to sail with passengers until CG-835 items NY10, 12, 13, 14, 15, are cleared to the satisfaction of an attending marine inspector and a new Certificate of Inspection is issued.
Documentation
Issued 27 May 1999
Resolved
Designate senior deckhand in writing IAW NVIC 1-91.
Lifesaving
Issued 27 May 1999
Resolved
Provide onboard 3 additional orange flares.
Documentation
Issued 27 May 1999
Resolved
Provide masters license and radio operators permit.
Lifesaving
Issued 27 May 1999
Resolved
Remove stored combustibles from engine room.
Lifesaving
Issued 27 May 1999
Resolved
Register EPIRB with NOAA and affix label to unit.
Construction/Loadline
Issued 9 March 1998
Resolved
Conduct an undereway exam of the vessel to the satisfaction of the attending marine inspector, no later than 15 Apr 98.
Lifesaving
Issued 9 March 1998
Resolved
Conduct underway man overboard and fire drills prior to 15 Apr 98.
Construction/Loadline
Issued 17 November 1997
Resolved
DRYDOCK VESSEL PRIOR TO CARRYING PASSENGERS FOR HIRE BUT NOT LATER THAN _x001C_ 1 APRIL 1998.
Lifesaving
Issued 28 March 1997
Resolved
Provide a 406 EPIRB. The vessel is restricted to operating within the territorial sea baseline until this requirement is met.
Lifesaving
Issued 28 March 1997
Resolved
Conduct underway man overboard and fire drills to the satisfaction of the attending marine inspector.
Navigation
Issued 28 March 1997
Resolved
Properly install the double nuts on the port rudder arm.
Construction/Loadline
Issued 22 March 1996
Resolved
make proper repairs to the forward hatch dog. To be completed to the satisfaction of the attending marine inspector.
Navigation
Issued 27 March 1995
Resolved
INSTALL PROPER SAFETY PIN IN STEERING LINKAGE.
Lifesaving
Issued 27 March 1995
Resolved
PROVIDE PROPER FLOAT LIGHT FOR BUOYANT APPARATUS.
Lifesaving
Issued 27 March 1995
Resolved
INSTALL ADEQUATE RAILING AROUND LADDER OPENING TO SECOND DECK.
Engineering
Issued 27 March 1995
Resolved
PROVIDE ADEQUATE GUARD FRO PULLEYS ON PORT ENG.
Navigation
Issued 27 March 1995
Resolved
PROVIDE UPDATED RULES OF THE ROAD PUB
Construction/Loadline
Issued 14 March 1994
Resolved
FOUND THE #5 AND #6 FLOOR KEEL BOLTS, THE CHINE BOLT IN THE #9 PORT FRAME BAY AND THE THE LOWER FASTNER FOR THE #9 STARBOARD VERTICLE FRAME WASTED. ALL OTHER FASTNERS WERE FOUND TO BE SATISFACTORY.
Navigation
Issued 30 March 1993
Resolved
BRING VESSEL INTO COPMPLIANCE WITH THE NAVIGATION RULES REGARDING THE VERTICLE SEPARATION OF THE FORWARD MASTHEAD AND SIDE RUNNING LIGHTS.
Navigation
Issued 27 March 1991
Resolved
INSTALL PROPER NAVIGATION LIGHTS TO MEET INTERNATIONAL RULES.
Casualty record · 4
24 June 2006Routine · role: Involved in a Marine Casualty · activity 2782907
16 September 2006Routine · role: Acknowledged Pollution Source · activity 2781032
9 September 2007Routine · role: Suspected to be in Violation of Law or Reg · activity 3054529
24 July 2010Routine · role: Involved in a Marine Casualty · activity 3872395
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
BULLET II (2006–2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.