MAURY USCG vessel records Sign in
← All vessels

CROWN RUBY

CROWN RUBY is a 1997 freight ship. The Coast Guard has recorded 36 inspections since 1997, most recently in January 2025, along with 18 deficiencies and 1 operational control.

Records from 1997 to 2025. Most recent: inspection, 23 January 2025.

Built
1997
Last inspected
23 January 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9159103 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
465343
Flag
BAHAMAS, THE
—
Maury page id
psix-465343

Inspections, by type

…with no type recorded13
Years with a record 21 calendar years (1997–2025)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it10519 - Convention (Subpart B), Gross Ton
10519 - Regulatory (Subpart C or D), Gross Ton
5406 - Convention (Subpart B), Net Ton
5406 - Regulatory (Subpart C or D), Net Ton
10338 - Dead Weight, Metric Ton
16522 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 36

23 January 2025 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8067687
25 June 2024 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7941864
21 June 2024 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7939521
28 February 2022 Administrative Inspection · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7403003
28 January 2021 PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7129376
8 January 2020 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6884834
31 January 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6346939
28 December 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6329639
17 August 2011 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4118605
16 October 2010 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3870992
13 September 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3849037
25 October 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3351243
23 September 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3064097
4 September 2007 MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3054565
17 April 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2909431
22 September 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2784477
30 August 2006 ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2763911
12 June 2006 Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2677157
12 June 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2683096
9 March 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2601222
11 October 2005 ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2512032
19 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2244329
25 October 2004 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2227549
12 July 2004 PII Safety Exam · ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2130018
25 December 2003 MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1969480
16 September 2002 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1677291
28 May 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1621648
30 July 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 292402
23 May 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1066793
28 March 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 288688
23 May 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 278217
21 January 2000 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1048078
10 August 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 777004
3 January 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 424210
24 August 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 419644
12 December 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 410217

Deficiency record · 18

03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 2 March 2022 Resolved
All pipes to which this regulation refers shall be of steel or other equivalent materual to the satisfaction of the administration. PSCO observed a soft patch on the water maker intake piping system.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 March 2022
Resolved 24 March 2022
Resolution: Received class report attesting to satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 2 March 2022 Resolved
the condition of the ship and its equipment shall be maintianed to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO noticed damage on deck in CO2 room.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 March 2022
Resolved 24 March 2022
Resolution: Received class report attesting to satisfactory repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 January 2020 Resolved
THE VESSEL OPERATOR SHALL KEEP A WRITTEN RECORD AVAILABLE FOR INSPECTION BY CAPTAIN OF THE PORT OF THE DATE AND RESULT OF THE MOST RECENT TEST AND INSPECTION OF EACH ITEM TESTED AS REQUIRED BY 33CFR156.170. CREW COULD NOT PROVIDE DOCUMENTATION ATTESTING TO REQUIRE TEST OF BUNKER LINE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 January 2020
Resolved 28 January 2021
Resolution: Vessel provided documentation of bunker line test completed on 16FEB20.
Engineering › Steam System (auxiliary) › Piping
Issued 13 September 2010 Resolved
THE NUMBER 1 FUEL LINES AUXILIARY STEAM LINE AT THE "Y" CONNECTION HAS A STEAM LEAK DRIPPING WITH SAME SPRAY WHICH COULD CAUSE INJURY TO THE CREW. CREWS TO SECURE LEAK. SOLAS 74 CH1 70(a) 04 CONS. REG II ACTION TAKEN 1499
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2010
Resolution: Permanent repair work is carried out by replacement of the T Union. Deficiency rectified by class.
Engineering › Compressed Air System (start air) › Compressor
Issued 13 September 2010 Resolved
A FLEXABLE HOSING MODIFICATION HAS BEEN MADE TO THE STARTING AIR COMPRESSOR'S INTAKE OF AIR. NO MODIFICATION SHALL BE MADE TO THE VESSEL'S EQUIPMENT WITHOUT THE APPROVAL OF ADMINISTRATION. SOLAS 74 CH1 70(a) 04 CONS. REGII
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2010
Resolution: Portable flexible hose removed from air compressor intake. Deficiency rectified by class.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 September 2010 Resolved
ENGINE ROOM CLEALINESS FOUND TO BE UNSATISFACTORY AND PRESENT A SIGNIFICANT SAFETY AND FIRE HAZARD. PROVISIONS SHALL BE MADE TO FACILITATE CLEANING OF MAIN AND AUXILIARY SYSTEMS. THE TEAM FOUND OILY RAGS, PUDDLES OF OIL AROUND THE HIGH PRESSURE FUEL PUMPS ON THE MAIN ENGINE, AND RESIDUE LEAKS ON GENERATOR (MAIN AND AUXILIRY). SOLAS 74 CHII-I 04 CONS REG. 26.7
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2010
Resolution: Mentioned area and all E/R cleaned and painted. Deficiency rectified by class.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 September 2010 Resolved
NO CHANGE SHALL BE MADE IN THE STRUTUARAL ARRANGMENT OF MACHINERY WITHOUT APPROVAL OF THE ADMINISTRATION. METAL BARS HAVE BEEN WELDED TO THE BULKHEAD BETWEEN FRAMES 30 AND 40. SOLAS 74 CHi 70(a) 04 CONS. REG II
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2010
Resolution: All pipe and Angles attached the hull structure was removed and area painted. Deficiency rectified by class.
Construction/Loadline › Structures › End Bulkhead
Issued 13 September 2010 Resolved
THE ENGINE ROOM ON THE STARBOARD SIDE FORWARD BULKHEAD (WALL) HAS A WORK AREA FOR CLEANING OIL FILTERS. THE AREA IS MADE OF PLYWOOD AND HAS BAMBOO POLES IN THE OVERHEAD. THIS WAS NOT APPROVED BY CLASS AS A WORK SPACE. VESSEL IS TO HAVE THIS AREA APPROVED AS A WORK SPACE OR MUST REMOVE THE ITEMS FROM THE AREA SOLAS 74/AMED 2004 CONSILIDATED 70(a) CHAPTER1 REG 11.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2010
Resolution: Removed wooden structure around filter cleaning area and area cleaned & painted. Deficiency rectified by class.
Electrical › Electric Generation Source (emergency) › Generator
Issued 4 September 2007 Resolved
Tracing steam pipe valve for the aux generator was allowing a small stream of steam to come out through the valve gland.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 16 October 2007
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 September 2007 Resolved
"A" Class fire door (self closing type) did not have the mechanism that enables a tight closing of door. Door shall be kept closed permanently until appropiate repairs are done. This door shall be made "A" - 60 self closing as per vessel fire control plan.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 16 October 2007
Navigation › Piloting/Steering › Gyro Compass
Issued 22 September 2006 Resolved
LOD ARRIVAL. Gyro inoperative
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2006
Resolution: Received Tech. Report, Gyro compass repaird on 9/23/2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 October 2005 Resolved
Ladder leading from deck "A" into "Poop" deck does not have a hand rail, this could be a potential hazard to anyone due to opening straight down unto ladder going downward.
Condition: Design Flaw
Due 11 November 2005
Resolved 14 October 2005
Resolution: Sector San [name withheld] Division received a statement from the master attesting to effective installment of hand rail to ladder.
Engineering › Steam System (main) › Piping
Issued 12 July 2004 Resolved
Replace steam line forward of main diesel engine between 4S and 3Center piping.
Condition: Unknown
Due 15 August 2004
Resolved 16 July 2004
Resolution: Received statement from master that deficiency has been rectified.
Engineering › Pressure Vessel › Piping
Issued 12 July 2004 Resolved
Repair eductor outlet piping forward of evaporator piping
Due 15 August 2004
Resolved 25 July 2004
Resolution: Received statement from master that deficiency has been rectified.
Electrical › Lighting (service) › Switch
Issued 12 July 2004 Resolved
Replace Switch indicator covers for both steering gear pumps controllers.
Due 16 August 2004
Resolved 25 October 2004
Resolution: Witnessed newly replaced switch indicator covers for both steering gear pump controllers.
Stability › Watertight Integrity › General
Issued 12 July 2004 Resolved
Repair hole in bulkhead IWO access door leading to engine room from main deck
Due 16 August 2004
Resolved 16 July 2004
Resolution: Received statement from master that deficiency has been rectified.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 July 2004 Resolved
Repair damper near main generator
Due 16 August 2004
Resolved 16 July 2004
Resolution: Received statement from master that deficiency has been rectified.
Engineering › Bilge Water Management System
Issued 16 September 2002 Resolved
REPLACE FLAME SCREEN TO THE BILGE SEPARATION IWO STBD SIDE, BY 16OCT02. LEGACY COMPONENT DESC: Vent
Condition: Unknown
Due 16 October 2002
Resolved 25 December 2003
Resolution: Witnessed new flame screen during annual exam on 25 Dec 2003.

Ownership record