← All vessels
USNS HENSON
USNS HENSON is a 1998 research vessel. The Coast Guard has recorded 97 inspections since 1997, most recently in July 2026, along with 90 deficiencies and 3 operational controls.
Records from 1997 to 2026. Most recent: inspection, 14 July 2026.
- Built
- 1998
- Last inspected
- 14 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 90 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9132129 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
NENB
465351
Flag
UNITED STATES
—
Maury page id
psix-465351
Inspections, by type
…with no type recorded25
Years with a record
26 calendar years (1997–2026)
The 97 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it4201 - Convention (Subpart B), Gross Ton
1260 - Convention (Subpart B), Net Ton
2328 - Dead Weight, Ton
1260 - Convention (Subpart B), Net Ton
2328 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 97
14 July 2026
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8437599
26 April 2026
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8362034
30 March 2026
Periodic Inspection · ACP Periodic Oversight · Administrative Inspection · Vessel Attendance
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8333853
4 January 2026
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8290596
29 December 2025
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8287892
6 May 2025
Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8135663
12 February 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8097585
13 January 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8062598
6 November 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8039450
14 August 2024
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7984912
30 May 2024
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7922880
21 May 2024
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7916671
21 March 2024
Damage Survey
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7883265
15 December 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7839647
12 October 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7807770
12 October 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7809701
28 July 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7757453
27 June 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7724478
30 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7849173
27 April 2023
ACP COI Oversight · Re-Inspection · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7639216
11 February 2023
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8235429
12 December 2022
Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7607496
29 November 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7604564
4 November 2022
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7596567
2 August 2022
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7554832
23 May 2022
Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7457777
4 October 2021
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7326749
12 August 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7284932
3 August 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7276129
2 August 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7275521
27 July 2021
Annual Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7264861
23 December 2020
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7119603
24 August 2020
Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7041841
20 August 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7041925
17 May 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6956246
16 April 2020
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7821383
4 March 2020
Administrative Inspection · Damage Survey · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6920905
31 May 2019
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6698989
3 April 2019
COI Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6640670
17 December 2018
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6598700
15 February 2018
ACP Drydock Oversight · Hull Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6355382
13 January 2018
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6382659
11 October 2017
ACP COI Oversight · Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6285236
9 September 2017
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6265560
9 April 2017
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6169114
17 February 2017
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6103517
30 November 2016
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6049674
20 November 2016
Administrative Inspection
Administrative · Activities Europe · Activity 6045659
30 October 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6058655
14 July 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5940158
22 June 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5917406
1 April 2016
Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5844892
2 March 2016
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 5814043
3 February 2016
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6024475
3 January 2016
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5790131
5 May 2014
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 4852190
18 March 2010
ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3724650
6 January 2009
ACP Annual Oversight
Administrative · Activities Europe · Activity 3401988
23 October 2008
Deficiency Check
Physical examination · Activities Europe · Activity 3351183
24 September 2008
Type not recorded
No type recorded · Activities Europe · Activity 3384465
7 February 2008
ACP COI Oversight · MARPOL Annex V Examination · COI Inspection · MARPOL Annex I Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3143183
15 May 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2997252
26 April 2007
ACP Annual Oversight
Administrative · Activities Europe · Activity 2911544
16 May 2006
Type not recorded
No type recorded · Activities Europe · Activity 2692761
7 March 2006
ACP Periodic Oversight · Periodic Inspection
Physical examination · Activities Europe · Activity 2589779
16 May 2005
Administrative Inspection
Administrative · Activities Europe · Activity 2358850
23 February 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2312718
23 February 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2312730
15 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293072
14 February 2005
MTSA/ISPS Verification · Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2307438
18 January 2005
Administrative Inspection
Administrative · Activities Europe · Activity 2311287
15 December 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2259757
20 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104615
28 February 2004
Internal Structural Exam · Hull Examination · ACP COI Oversight · Administrative Inspection
Physical examination · Activities Europe · Activity 1960973
29 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996860
4 August 2003
Type not recorded
No type recorded · Activities Europe · Activity 1902249
27 January 2003
Type not recorded
No type recorded · Activities Europe · Activity 1735673
23 January 2003
Type not recorded
No type recorded · Activities Europe · Activity 1761877
3 December 2002
COI Inspection
Physical examination · Activities Europe · Activity 1699866
8 March 2002
Hull Examination
Physical examination · Activities Europe · Activity 1488690
27 December 2001
COI Inspection
Physical examination · Activities Europe · Activity 1473961
7 November 2001
Administrative
Administrative · Activities Europe · Activity 1076096
12 March 2001
Re-Inspection
Physical examination · Activities Europe · Activity 1418928
2 February 2001
Deficiency Check
Physical examination · Activities Europe · Activity 1057183
13 March 2000
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 816019
6 March 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1046486
26 January 2000
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1045663
25 January 2000
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1456784
18 October 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 215497
1 October 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 218260
24 May 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1408332
22 March 1999
Examination of Repairs · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1471553
13 January 1999
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 810271
23 July 1998
Excursion Permit
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1130411
25 June 1998
Excursion Permit
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 793065
19 February 1998
Initial Certification · Construction Oversight · Hull Examination · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1364790
6 October 1997
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 789146
Deficiency record · 90
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 May 2026
Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of of the relevant rules and regulations. In meeting these requirements the company should ensure the inspections are held at appropriate intervals, any non-conformity is reported, with its possible cause, if known, appropriate corrective action is taken; and records of these activities are maintained. Vessel is enrolled in ABS Planned Maintenance Program (PMP). A review of randomly select items from the annual vibration and oil analysis reports, identified that several critical components required immediate attention (Bow Thruster Lube Oil Pump, Air Operated Oily Waste Transfer Pump, #1 Main Propulsion Generator). Review of the vessels SAMMS maintenance program revealed no corrective actions had been taken for these items. Conduct external audit on ABS planned maintenance program. 74 SOLAS (24)IX/3.1, ISM Reg. 10.1 and 10.2
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 August 2024
Resolved
Vessel reported a scheduled AFFF agent lab test cameback as unstable. Vessel used back-up agent to replace the primary that was unstable. Vessel is required to have backup AFFF agent in accordance with their approved fire plan. 46CFR193.05-10(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2024
Resolved
A sufficient number of lifejackets shall be carried for persons on watch. Lifejackets shall be so placed as to be readily accessible and their position shall be plainly indicated. Where, due to the particular arrangements of the ship, the lifejackets provided may become inaccessible and alternative provisions shall be made to the satisfaction of the Administration which may include an increase in the number of lifejackets to be carried. Engine Control Room does not have adequate number of life jackets and immersion suits for watch standers when personal survival appliances may be inaccessible. Fire control plan and SOLAS placards to be updated to include personal survival appliances to be stowed in the ECR for both watchstanders.
74 SOLAS (1997) III/7.1.1.2 and 74 SOLAS (1997)
III/7.2.2
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 May 2022
Resolved
The port and stbd engine room supply dampeners and natural supply dampeners do not fully close when activated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 May 2022
Resolved
The port and stbd life boat's aft quarter is damaged by the davit's inboard aft resting blocks. Make repairs in accordance with manufacture's approved procedures and provide approval letter.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 May 2022
Resolved
The port and starboard life boat's davit has excessive metal wastage on the davit's harbor locking pins receptacle padeyes and accepting flat bar, cable pulley mounts, & davit arm heads.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 24 May 2022
Resolved
The port life boat embarkation station flood lamp mount has broken off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2020
Resolved
Every ship shall be provided with a main and auxiliary steering system to the satisfaction of the administration. Vessel's thruster system is inoperable and satisfactory operation was unable to be witnessed.
74 SOLAS(14) II-1/29.1
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 August 2020
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. Machinery space fire dampers failed to fully close upon activation of remote ventilation shutdown.
74 SOLAS(14) II-2/14.2.1.1.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 August 2020
Resolved
Where penetrations of watertight bulkheads and internal decks are necessary for access, piping, ventilation, electrical cables etc. arrangements are to be made to maintain watertight integrity. Power cable for STBD underwater hull shall be routed through the fore and aft watertight bulkheads of the space with type approved penetrations.
74 SOLAS(04) II-1/25-9.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 August 2020
Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. 480 volt junction shall be replaced with appropriate type/size and dead end cable shall be removed or properly terminated.
74 SOLAS(04) II-1/40.1.3
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 25 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea. The main deck port side vent at location 01-25-2 found wasted and non weathertight.
74 SOLAS(14) I/11
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 August 2020
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. Vent cover associated with generator room (01-7-1) on 01 starboard deck has 04 holes cut into the bottom which circumvent closure as well as a wasted portion on the bottom outboard and a separate hole around the exterior siding of the vent housing.
74 SOLAS(04) II-2/14.2.1.1.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 August 2020
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire resistant divisions, and protection of openings and penetrations in these divisions. Vessel found with the following fire screen doors out of compliance: 1-5-4-3 (fan room inside conference room does not fully close), 1-112-0 (staging bay door main deck does not fully close). 1-87-2 & 01-66-1 (lower hose ports damaged), and the galley and compactor spaces have holdback hooks which prevent required self-closing.
74 SOLAS(04) II-2/14.2.1.1.1
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 25 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Forward and aft wire ropes on port lifeboat that attach to bow and stern horns have frayed and broken wires.
74 SOLAS(14) I/11
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 August 2020
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Electrical box in overhead of chart room missing cover and wire wrapped in electrical tape. Exposed wire associated with wiper on port bridge wing.
74 SOLAS (04) II-1/40
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 25 August 2020
Resolved
Every person designated to take charge of medical care onboard vessels subject to the STCW Convention must hold an MMD or MMC endorsed as person in charge of medical care. Vessel has onboard ships 'Medic/Nurse' who does not currently hold endorsement for person in charge of medical care.
46CFR15.404(i).
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 August 2020
Resolved
The following fire protection systems shall be kept kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. The following multiple cable transits shall be installed IAW type approval: All transits from chart room to bridge; bridge console to belowdecks; main switchboard transits fore and aft; MCT # 76 & # 12
74 SOLAS(04) II-2/14.2.1.1.1
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 August 2020
Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks of cargo ships, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 9.5 and 9.6. Opening in two class A galley pass through bulkheads are protected with steel roller shutters and dedicated fusible links. Fubislbe links are concealed within metal overhead and shielding them from heat/proper operation. Install links so they are exposed to properly operate in the event of a fire.
74 SOLAS(14) II-2/9.2.3.3.1
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 25 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Upper boat deck near port bridge wing had wasted handle and piping on pneumatic line coming through house bulkhead.
74 SOLAS(14) I/11
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 August 2020
Resolved
The Administration shall satisfy itself that the general structural strength of the ship is adequate for the draught corresponding to the freeboard assigned. Noted holed bulkhead on port side main deck below vent 01-90-2.
IICL 66, Reg 1
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 25 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Port side main deck ‘sea beam cable’ vent wasted and broken off where pipe penetrates main deck. Forward railing around port lilfeboat wasted and port and starboard stanchion eyes for securing railing on main deck are wasted in several locations.
74 SOLAS(14) I/11
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 25 August 2020
Resolved
All such openings in the bulwarks shall be protected by rails or bars spaced approximately 9 inches apart. Removable chains on starboard main deck exceeded 9 inches in two locations. Install proper rail heights on removable portions of starboard main deck rails.
IICL 66, Reg 24
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Port side forward davit hook tied into gripe is showing signs of necking/wastage. Replace or repair hook.
74 SOLAS(14) I/11
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Several faded ring buoy placards throughout weather decks. Replace all faded ring buoy placards.
74 SOLAS (14) I/11
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 August 2020
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. Noted lifting arrangement on galley deck that passes through hatch on several subsequent A boundary decks below for the purpose of moving ship’s stores were left open. Crew stated hatches were left open during working hours which would allow a fire to immediately propagate to multiple decks in the event of a fire. Directed crew to secure hatches immediately after each use.
74 SOLAS(14) II-2/14.2.1.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 March 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The number one start air compressor's electric motor failed which rendered the number one start air compressor inoperable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2019
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Ballast/SW Cooling pipe located in overhead in aft pump room found with temporary repair (JB Weld/rubber patch/C-clamped) Make permanent repairs to the damaged section of piping as designed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 April 2019
Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. Ventilation closure on port side 01 deck at FR76 found to be inoperable as handle moves but internal mechanics do not operate. Make permanent repairs as required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 18 December 2018
Resolved
ICLL 66 Reg. 1; 46 CFR 42.09-45(a): Crop out wasted edges on watertight ventilation enclosure on stbed main deck and repair to as original prior to departure to the satisfaction of attending Classification Society.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 December 2018
Resolved
ICLL 66 Reg. 1; 46 CFR 42.09-45(a): Watertight door to ET shop on stbd side main deck with hole. Crop out to good metal and repair to as original prior to departure to the satisfaction of the attending Classification Society.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 December 2018
Resolved
ICLL 66 Reg. 1; 46 CFR 42.09-45(a): Watertight door to lab on stbd side main deck with wastage. Crop out to good metal and repair to as original prior to departure to the satisfaction of attending Classification Society.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 December 2018
Resolved
46CFR199.70(a)(3)/199.45(b)(3): Stbd ring buoy lanyard with dry rot. Replace with new to as original. Ring buoy, smoke float, and buoyant light must be properly installed in a quick release buoy bracket to allow all three to easily deploy.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 December 2018
Resolved
46CFR199.70(b)(2)(i): USCG observed crewmember on bridge having difficulty removing PFDs that are jammed inside stowage box attached to bulkhead. Install larger stowage box for bridge watch stander PFDs or provide alternative location on bridge to stow PFDs to be readily available.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 March 2016
Resolved
Oily Water Seperator is inoperable as designed. When operating underway vessel must retain waste oil/slops onboard. In-port vessel will discharge to approved shore side facility or another vessel until repairs are completed. Make permanent repairs IAW manufacturers specifications.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 March 2016
Resolved
Approximately 20% of onboard life-jackets have holes/tearing and are past service life. Replace holed/deteriorating jackets. The remaining 80% are nearing service life expiration. Recommend implementing replacement plan over next few years to replace remaining deteriorating life-jackets.
Lifesaving › Lifeboat › Propulsion Engine
Issued 18 March 2010
Resolved
Provide tech report from [name withheld] showing satisfactory repair of port lifeboat lube oil leak. Turbo charger seal allowed lube oil to leak through exhaust outlet.
Engineering › Non-conventional Propulsion/Steering › Control Systems (Azipod)
Issued 26 April 2007
Resolved
PROVE PROPER OPERATION OF # 1 MOTOR PROPULSION UNIT.
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 26 April 2007
Resolved
PROVE PROPER OPERATION OF # 2 SSGD.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 April 2007
Resolved
PROVE PROPER OPERATION OF THE OWS.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piston
Issued 26 April 2007
Resolved
PROVE PROPER OPERATION OF THE # 3 SSDG.
Lifesaving › Lifeboat › Fender
Issued 7 March 2006
Resolved
Replace rubber guards on port lifeboat.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 7 March 2006
Resolved
Provide letter as to shelf life of EEBD's.
Engineering › Fuel Oil Service System › Valve
Issued 7 March 2006
Resolved
F/O shut off valves not operating, prove proper operation.
Fire Fighting › Emergency Fire Pumps › Location
Issued 7 March 2006
Resolved
Label emergency fire pump on diagram.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 7 March 2006
Resolved
Repair emergency fire pump, to the satisfaction of the attending ABS surveyor.
Engineering › Steering Gear System › Power Unit
Issued 7 March 2006
Resolved
Prove steering gear alarms as required by SOLAS.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 March 2006
Resolved
Place on the SAMMS PMS the testing of fuel shutoff valves.
Stability › Watertight Integrity › General
Issued 7 March 2006
Resolved
Adjust WTD in steering gear room.
Engineering › Steering Gear System › Hydraulic Hose
Issued 7 March 2006
Resolved
Repair leaks in steering gear.
Fire Fighting › Ventilation Systems › Ducts
Issued 7 March 2006
Resolved
Repair supply/exhaust vents on deck for MDE.
Lifesaving › Lifeboat › Propulsion Engine
Issued 7 March 2006
Resolved
Repair the starboard lifeboat steering system.
Engineering › Fuel Oil Service System › Valve, Control
Issued 28 February 2004
Resolved
make permanant repairs to pneuemtaic fuel oil shut off vales in 1-12-2, 4-81-2 and 4-80-3.
Lifesaving › Lifeboat › Propulsion Engine
Issued 28 February 2004
Resolved
port life boat engine produces an oil sheen when put in the water. Make necessary repairs and prove proper operations of port life boat.
Lifesaving › Lifeboat
Issued 27 January 2003
Resolved
Bushings failed on #2 lifeboat propulsion shaft. Vessel has conducted temp repairs and will complete permenant repairs prior to departure from next port call. LEGACY COMPONENT DESC: Propeller Shaft
Documentation
Issued 12 March 2001
Resolved
Provide all SOVC statutory compliance documents per MSC message.
Fire Fighting
Issued 2 February 2001
Resolved
FIXED HIGH PRESSURE HALON CYLINDER USED AT PAINT LOCKER; RETEST, REFILL ANDRETURN TO SERVICE ACCORDING TO 49CFR173. INSTALLATION TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Fire Fighting
Issued 25 January 2000
Resolved
Conduct hydro test of all composite self contained breathing appratus air bottles._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 25 January 2000
Resolved
PROPERLY REPAIR FIRE SCREEN DOOR 2-104-0._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 25 January 2000
Resolved
Adjust auto closure to fire screen door 1-87-2.
Fire Fighting
Issued 25 January 2000
Resolved
Repair fire hose port to fire screen door 1-120-2.
Fire Fighting
Issued 25 January 2000
Resolved
PROVIDE FOAM ANALYSIS REPORT TO MSO SAN JUAN._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 25 January 2000
Resolved
Remove dead-end wiring to port and starboard propulsion meter temperature guage.
Fire Fighting
Issued 25 January 2000
Resolved
CONDUCT FUNCTION TEST OF FUEL OIL EMERGENCY CONTROL VALVES LOCATED IN CONTROL_x001C_ ROOM.
Unknown
Issued 25 January 2000
Resolved
PROPERLY LABEL ACTIVATION INSTRUCTIONS TO ESD SWITCHS TO MAIN PROPULSION SYSTEMS INDICATION DIRECTION OF ACTIVATION.
Documentation
Issued 25 January 2000
Resolved
PROVIDE TRAINING MANUAL TO CREW AND OFFICERS MESS IN ACCORDANCE WITH 46 CFR199.180_x001C_
Engineering
Issued 25 January 2000
Resolved
CONDUCT FUNCTION TEST OF FUEL OIL TRANSFER PUMP REMOTE SHUT DOWN._x001C_
Engineering
Issued 25 January 2000
Resolved
INSTALL FLAME SCREENS TO VENTS: 4-10-0 & 4-35-1.
Lifesaving
Issued 25 January 2000
Resolved
CONDUCT WEIGHT TEST OF PORT LIFEBOAT TO THE SATISFACTION OF CG MARINE INSPECTOR.
Lifesaving
Issued 25 January 2000
Resolved
PROPERLY INSTALL LIFERAFTS INTO CRADELS PRIOR TO VESSEL DEPARTURE._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 25 January 2000
Resolved
PROVIDE SERVICING REPORTS FOR AL LIFERAFTS TO MSO SAN JUAN.
Lifesaving
Issued 25 January 2000
Resolved
RENEW RETRO-REFLECTIVE TAPE ON TOP AND OUTBOARD SIDES OF BOTH THE PORT AND STARBOARD LIFEBOATS.
Lifesaving
Issued 25 January 2000
Resolved
REPAIR THE PORT LIFEBOAT AFT WINDOW.
Lifesaving
Issued 25 January 2000
Resolved
CONDUCT FUNCTION TEST OF PORT LIFEBOAT ENGINE PRIOR TO VESSEL DEPARTURE._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 25 January 2000
Resolved
PROPERLY BLANK ELECTRICAL BOX OPENING ABOVE FSD 1-99-1. BULKHEAD IN THE DRY& BIOCHEM LAB.
Lifesaving
Issued 25 January 2000
Resolved
STENCIL BOAT NUMBER AND NAME ON TOP OF BOTH LIFEBOATS.
Engineering
Issued 25 January 2000
Resolved
Conduct hydro test of fuel oil bunker piping in accordance with 46 CFR 156.170(c)(4)._x001C_ _x001C_ _x001C_
Unknown
Issued 25 January 2000
Resolved
Provide calibration gas for the breath testing device._x001C_ 46CFR16.240
Fire Fighting
Issued 25 January 2000
Resolved
Remove all foot and other door hold backs to firescreen doors in machinery spaces prior to departure._x001C_ _x001C_ _x001C_
Documentation
Issued 25 January 2000
Resolved
Provide fire fighting report to MSO San Juan._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 24 May 1999
Resolved
CHECK AND REPLACE AS NEEDED BATTLE LANTERN BATTERIES THROUGHOUT VESSEL AND IN PARTICULAR - BRIDGE BATTLE LANTERNS.
Fire Fighting
Issued 24 May 1999
Resolved
REPAIR OR REPLACE THE OXYGEN ANALYZER IN FORWARD REPAIR LOCKER.
Lifesaving
Issued 24 May 1999
Resolved
REPLACE BATTERIES IN WATERLIGHTS WITH APPROVED TYPE.
Fire Fighting
Issued 24 May 1999
Resolved
PROVIDE EVIDENCE OF ANNUAL FIXED & PORTABLE FIRE EXTINGUISHING SYSTEMS FROMAN APPROVED SERVICING FACILITY.
Construction/Loadline
Issued 24 May 1999
Resolved
REPAIR INOPERATIVE CLASS 3 DOOR INDICATING LIGHTS ON BRIDGE PANEL.
Fire Fighting
Issued 24 May 1999
Resolved
REMOVE UNAPPROVED CO2 SHUTDOWN SWITCH IN BOW THRUSTER ENCLOSURE OR SUBMIT TO G-MSC FOR APPROVAL.
Fire Fighting
Issued 24 May 1999
Resolved
FREE UP AND TEST ALL WEATHER DECK FIRE DAMPERS.
Lifesaving
Issued 24 May 1999
Resolved
PROVIDE EVIDENCE OF ANNUAL LIFERAFT SERVICING FROM AN APPROVED SERVICING FACILITY.
Lifesaving
Issued 19 February 1998
Resolved
Perform satisfactory abandon ship drill.
Fire Fighting
Issued 19 February 1998
Resolved
Perform satisfactory fire drill.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.